HomeMy WebLinkAbout2657-344, CONSTRUCTION LEGEND • • • 0 0 AC PARKING LOT LAYOUT, GRADING, CONSTRUCTION, STRIPPING AND ETC.. PER S.P. CONSULTING GROUP. WOODCRETE RAIL FENCE PER DETAIL H SHEET LCD.1 EXISTING STONE ENTRY MONUMENTS AVAILABLE ON SITE. INSTALL AT' THIS- LOCATION, PROVIDE STRUCTURAL DETAIL OF FOOTING AND WALL ATTACHMENT AND OBTAIN APPROVAL FROM CITY OF FONTANA. 0 EXISTING FOUNTAIN AVAILABLE ON SITE. INSTALL AT THIS LOCATION, PROVIDE STRUCTURAL DETAIL OF FOOTING AND ATTACHMENT AND OBTAIN APPROVAL FROM CITY OF FONTANA. • • • • OPE.N METAL FENCE TO BE CONSTRUCTED BY OTHERS, N.I.C. DG. PATH, ALIGNMENT PER CIVIL PLANS, STAKE ALIGNMENT AND OBTAIN APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO REMOVAL OF ANY EXISTING PLANT MATERIAL. SEE DETAIL E SHEET LCD.1 0 CONCRETE WALK PER DETAIL D SHEET LCD.1 0 DETECTABLE WARNING GROOVES PER DETAIL A SHEET LCD.1 • \\::\',\N: '4\ IN EXPANSION JOINT PER DETAIL C SHEET LCD.1 TOOLED JOINT PER DETAIL B SHEET LCD.1 HANDICAP RAMPS PER S.P. CONSULTING GROUP. OPEN METAL FENCE PER DETAIL F SHEET LCD.1 LI.I. GA1-5 6' MASONRY WALL AND PILASTER PER DETAIL G SHEET LCD.1 GRANITE BOULDERS - SCALE SIZE PER PLAN (18"X2'X2', 2'X2'X2' & 2'X2'X3'). BOULDERS ARE AVAILABLE ON SITE. c) PIPS GA -1-F - HORIZONTAL- OPE.NIING , REFER Tcz, SAN 13ERINAkDINO icr- 0" CLEARANCE MACH SIPE /77,___________2‹ FIRE AccESS ROAD/ 20=0" cLEARANcE INDICATES AREA TO RECEIVE DRIP IRR:GATION AT E4CH LOCAT ION CONTR t\CTOR TO PROVIDE AND INSTALL APPROXIMATELY 80' OF 3/4" RAINBIRD XERITUBE POLYETHELENE TUBING, 4- 3/4" AG. PRODUCTS ' SPIN LOCK" FLUSH CAPS AND RAINBIRD PUNCH IN DRIP EMITTERS AS FOLLOWS: 2 %1.0 GPH PER 5 GAL. SHRUB 4 - 2.0 PER 5 OR 15 GAL TREE CONTRACTOR SHALL SUPPLY ACTUAL REQUIRED QUANTITY OF EMITTERS, DIST9IBUTION TUBING, TUBING STAKES AND BUG CAPS ACCORDING TO THE ACTUAL PLANT COUNT AND SIZE. ALL TUBING TO BE SECURELY ST4KED TO THE Gi-tOUND AND INSTALLATION APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLING MULCH. DRIP CONTROL VALVE ASSEMBLY TO INCLUDE 1" RAINBIRD tIpEB REMOTE CONTROL VALVE, 1" AG. PRODUCTS #4E WYE FILTER AND 1" SENNINGER #PR30-MF PRESSURE REGULATOR. INSTALL IN RECTANGULAR VP LVE BOX USING STANDARD INSTALLATION DETAIL. SYMBOL • • IRRIGATION MATERIAL LEGEND TORO XP !.3cto 14.12. POP-UP SHRUB ROTOR HEAD TORO 570MPR-15-H-PC SPRAY NOZZLE TORO 570MPR-15-F-PC SPRAY NOZZLE ' TORO 570MPR-4-EST-PC TORO 570MPR-4-CST-PC RAINBIRD SUPERIOR NIBCO RAIN BIRD TORO GPM PSI 2.4 25 1.5 30 3.0 30 .43 30 .86 30 RADIUS DETAIL 38' A 15' A 15' 4'X15' A 4'X30' A A DRIP CONTROL VALVE ASSEMBLY TO INCLUDE 1" RAINBIRD #PEI3 REMOTE CONTROL VALVE, 1"AG. PRODUCTS #4E WYE FILTER AND 1" SENNINGER #PR30-MF PRESSURE REGULATOR. INSTALL IN RECTANGULAR VALVE BOX USING STANDARD INSTALLATION DETAIL. 3/4" CL -200 PVC LATERAL LINE TO CONNECT DRIP SYSTEMS AREAS. UVR PVC PIPE MAY BE USED AT THE DISCRETION OF THE L.A. AND CITY AS DETERMINED ON SITE. 2000E-2" "EPDXY FUSED" MASTER CONTROL VALVE T-136 BRONZE GATE VALVE, LINE SIZE 44RC QUICK COUPLER VALVE, INSTALL IN 10" ROUND VALVE BOX EFB-CP-PRS SERIES PRESSURE REDUCING BRASS REMOTE CONTROL VALVE, SIZE AS SHOWN FEESCO 825 Y 2" REDUCED PRESSURE BACKPLOW DEVICE W/ BRONZE WYE STRAINER, CLA-VAL 2" - #69-01 GLOBE TYPE PRESSURE REGULATRING VALVE, AND LE MEIAR. .5-rEr.L 13,44KFLow 132-86-08 NETWORK SATELLITE CONTROLLER, 32 STATIONS IN A LA G STA I N E. 5..5 COMMUNICATION LINE UNIT, AI -50 Pf_.0_,Y1DE. A "1716 l'AiL" 32 SIATION RAINNIASTER NOTES: 1. • • • • lo UVR PVC PIPE 3/4" - 3" SCH. 40 LATERAL LINES ON GRADESTAkE PIPE AT 8' 0.C. USING #4 REBAR J -HOOKS CL. 200 PVC LATERAL LINES 12" COVER, SIZE AS SHOWN. SCH. 40 PVC MAINLINE 24" COVER, SIZE AS SHOWN. SCH. 40 PVC SLEEVES, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED, INSTALL BELOW ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY CITY'S AUTHORIZED REPRESENTATIVE PAIGE TORO NETWORK 8000 COMMUNICATION CABLE, ARMORED DIRECT BURIAL TYPE, REFER TO STREETSCAPE PLANS FOR PHASE II FOR LOCATION OF COMMUNICATION CABLE MAKE CONNECTION TO CONTROLLER. CONSTANTFLO PUMP MODEL # 40BP204P2-5.0-CDEFGHIKM CAP LINE FOR FUTURE EXTENTION - FOR ALL HEADS INSTALLED WITH ON GRADE PIPING USE APPROPRIATE SHRUB ADAPTER VERSIONS OF POP-UP BODIES / NOZZLE AS SHOWN. INSTALL ANTI -DRAIN VALVES 5000 SERIES ON ALL SPRINKLERS WHERE LOW HEAD DRAINAGE MAY OCCUR. • 422 DATE DESCRIPTION APPROVED BY CITY' OF FONTANA 25126 CITY ENGINEER RCE TIPP WILDERNESS PARK TRACT 13750 - LOT El ACTUAL ADDRESS TO BE ASSIGNED BY THE CITY OF FONTANA BLDG. & SAFETY DEPT. NOTE: PERFORM ALL WORK TO COMPLY WITH 1994 UBC WITH CA. ADMENDMENTS & 1993 NEC WITH CA. ADMENDMENTS 30 15 GRAPHIC SCALE 30 eo 120 30315 CANWOCO STREET - sumo- 10 AGOURA HILLS. CALIFORNIA 91301 (818) 889-3904 FAX: (818) 889-9907 1932 E. DEER. E AVE - SUITE 100 SANTA ANA CALIFORNIA 92705 (714) 251-9655 FAX. (714) 251-9657 Signature cgt Tuzi rz4 I) 0 Revisions Wilderness CC I,OS ANGELES, CA. 90025 GLI cn 10-29-97 CITY P.C. REVISIONS 12-7-97 CITY P.C. REVISIONS 12-30-97 CITY P.C. REVISIONS 1-21-98 CITY P.C. REVISIONS Drawn By Sheet TItie Job No. Sheet No. JUNE 26, 1997 CONSTRUCTION / iRRIGATION PLAN 1923.6 LCI.2 3 ot 10 sheets Pw4, 2141