HomeMy WebLinkAbout2657-344,
CONSTRUCTION LEGEND
•
•
•
0
0
AC PARKING LOT LAYOUT, GRADING, CONSTRUCTION,
STRIPPING AND ETC.. PER S.P. CONSULTING GROUP.
WOODCRETE RAIL FENCE PER DETAIL H SHEET LCD.1
EXISTING STONE ENTRY MONUMENTS AVAILABLE ON SITE.
INSTALL AT' THIS- LOCATION, PROVIDE STRUCTURAL DETAIL OF
FOOTING AND WALL ATTACHMENT AND OBTAIN APPROVAL
FROM CITY OF FONTANA.
0 EXISTING FOUNTAIN AVAILABLE ON SITE. INSTALL AT THIS
LOCATION, PROVIDE STRUCTURAL DETAIL OF FOOTING AND
ATTACHMENT AND OBTAIN APPROVAL FROM CITY OF
FONTANA.
•
•
•
•
OPE.N METAL FENCE TO BE CONSTRUCTED BY OTHERS, N.I.C.
DG. PATH, ALIGNMENT PER CIVIL PLANS, STAKE ALIGNMENT
AND OBTAIN APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO
REMOVAL OF ANY EXISTING PLANT MATERIAL. SEE DETAIL E
SHEET LCD.1
0 CONCRETE WALK PER DETAIL D SHEET LCD.1
0 DETECTABLE WARNING GROOVES PER DETAIL A SHEET LCD.1
•
\\::\',\N: '4\
IN
EXPANSION JOINT PER DETAIL C SHEET LCD.1
TOOLED JOINT PER DETAIL B SHEET LCD.1
HANDICAP RAMPS PER S.P. CONSULTING GROUP.
OPEN METAL FENCE PER DETAIL F SHEET LCD.1 LI.I. GA1-5
6' MASONRY WALL AND PILASTER PER DETAIL G SHEET LCD.1
GRANITE BOULDERS - SCALE SIZE PER PLAN (18"X2'X2',
2'X2'X2' & 2'X2'X3'). BOULDERS ARE AVAILABLE ON SITE.
c) PIPS GA -1-F - HORIZONTAL- OPE.NIING , REFER Tcz, SAN 13ERINAkDINO
icr- 0" CLEARANCE
MACH SIPE
/77,___________2‹
FIRE AccESS ROAD/
20=0" cLEARANcE
INDICATES AREA TO RECEIVE DRIP IRR:GATION
AT E4CH LOCAT ION CONTR t\CTOR TO PROVIDE AND INSTALL
APPROXIMATELY 80' OF 3/4" RAINBIRD XERITUBE POLYETHELENE
TUBING, 4- 3/4" AG. PRODUCTS ' SPIN LOCK" FLUSH CAPS AND
RAINBIRD PUNCH IN DRIP EMITTERS AS FOLLOWS:
2 %1.0 GPH PER 5 GAL. SHRUB
4 - 2.0 PER 5 OR 15 GAL TREE
CONTRACTOR SHALL SUPPLY ACTUAL REQUIRED QUANTITY OF
EMITTERS, DIST9IBUTION TUBING, TUBING STAKES AND BUG CAPS
ACCORDING TO THE ACTUAL PLANT COUNT AND SIZE. ALL TUBING
TO BE SECURELY ST4KED TO THE Gi-tOUND AND INSTALLATION
APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLING MULCH.
DRIP CONTROL VALVE ASSEMBLY TO INCLUDE 1" RAINBIRD tIpEB
REMOTE CONTROL VALVE, 1" AG. PRODUCTS #4E WYE FILTER AND 1"
SENNINGER #PR30-MF PRESSURE REGULATOR. INSTALL IN
RECTANGULAR VP LVE BOX USING STANDARD INSTALLATION DETAIL.
SYMBOL
•
•
IRRIGATION MATERIAL LEGEND
TORO XP !.3cto 14.12. POP-UP SHRUB ROTOR HEAD
TORO 570MPR-15-H-PC SPRAY NOZZLE
TORO 570MPR-15-F-PC SPRAY NOZZLE '
TORO 570MPR-4-EST-PC
TORO 570MPR-4-CST-PC
RAINBIRD
SUPERIOR
NIBCO
RAIN BIRD
TORO
GPM PSI
2.4 25
1.5 30
3.0 30
.43 30
.86 30
RADIUS DETAIL
38' A
15' A
15'
4'X15' A
4'X30' A
A
DRIP CONTROL VALVE ASSEMBLY TO INCLUDE 1" RAINBIRD #PEI3 REMOTE CONTROL VALVE, 1"AG.
PRODUCTS #4E WYE FILTER AND 1" SENNINGER #PR30-MF PRESSURE REGULATOR. INSTALL IN
RECTANGULAR VALVE BOX USING STANDARD INSTALLATION DETAIL. 3/4" CL -200 PVC LATERAL
LINE TO CONNECT DRIP SYSTEMS AREAS. UVR PVC PIPE MAY BE USED AT THE DISCRETION OF THE
L.A. AND CITY AS DETERMINED ON SITE.
2000E-2" "EPDXY FUSED" MASTER CONTROL VALVE
T-136 BRONZE GATE VALVE, LINE SIZE
44RC QUICK COUPLER VALVE, INSTALL IN 10" ROUND VALVE BOX
EFB-CP-PRS SERIES PRESSURE REDUCING BRASS REMOTE CONTROL VALVE, SIZE AS SHOWN
FEESCO 825 Y 2" REDUCED PRESSURE BACKPLOW DEVICE W/ BRONZE WYE STRAINER,
CLA-VAL 2" - #69-01 GLOBE TYPE PRESSURE REGULATRING VALVE, AND LE MEIAR. .5-rEr.L 13,44KFLow
132-86-08 NETWORK SATELLITE CONTROLLER, 32 STATIONS IN A LA G STA I N E. 5..5
COMMUNICATION LINE UNIT, AI -50 Pf_.0_,Y1DE. A "1716 l'AiL" 32 SIATION RAINNIASTER
NOTES:
1.
•
•
•
•
lo
UVR PVC PIPE 3/4" - 3" SCH. 40 LATERAL LINES ON GRADESTAkE PIPE AT 8' 0.C. USING #4
REBAR J -HOOKS
CL. 200 PVC LATERAL LINES 12" COVER, SIZE AS SHOWN.
SCH. 40 PVC MAINLINE 24" COVER, SIZE AS SHOWN.
SCH. 40 PVC SLEEVES, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED, INSTALL BELOW
ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY CITY'S AUTHORIZED REPRESENTATIVE
PAIGE TORO NETWORK 8000 COMMUNICATION CABLE, ARMORED DIRECT BURIAL TYPE, REFER TO
STREETSCAPE PLANS FOR PHASE II FOR LOCATION OF COMMUNICATION CABLE MAKE CONNECTION
TO CONTROLLER.
CONSTANTFLO PUMP MODEL # 40BP204P2-5.0-CDEFGHIKM
CAP LINE FOR FUTURE EXTENTION -
FOR ALL HEADS INSTALLED WITH ON GRADE PIPING USE APPROPRIATE SHRUB ADAPTER VERSIONS OF POP-UP
BODIES / NOZZLE AS SHOWN.
INSTALL ANTI -DRAIN VALVES 5000 SERIES ON ALL SPRINKLERS WHERE LOW HEAD DRAINAGE MAY OCCUR. •
422
DATE
DESCRIPTION
APPROVED BY CITY' OF FONTANA
25126
CITY ENGINEER RCE
TIPP
WILDERNESS PARK
TRACT 13750 - LOT El
ACTUAL ADDRESS TO BE
ASSIGNED BY THE CITY OF
FONTANA BLDG. & SAFETY
DEPT.
NOTE: PERFORM ALL WORK TO COMPLY
WITH 1994 UBC WITH CA. ADMENDMENTS
& 1993 NEC WITH CA. ADMENDMENTS
30
15
GRAPHIC SCALE
30
eo
120
30315 CANWOCO STREET - sumo- 10
AGOURA HILLS. CALIFORNIA 91301
(818) 889-3904 FAX: (818) 889-9907
1932 E. DEER. E AVE - SUITE 100
SANTA ANA CALIFORNIA 92705
(714) 251-9655 FAX. (714) 251-9657
Signature
cgt
Tuzi
rz4
I) 0
Revisions
Wilderness
CC
I,OS ANGELES, CA. 90025
GLI
cn
10-29-97 CITY P.C. REVISIONS
12-7-97 CITY P.C. REVISIONS
12-30-97 CITY P.C. REVISIONS
1-21-98 CITY P.C. REVISIONS
Drawn By
Sheet TItie
Job No.
Sheet No.
JUNE 26, 1997
CONSTRUCTION /
iRRIGATION PLAN
1923.6
LCI.2
3 ot 10 sheets
Pw4, 2141