HomeMy WebLinkAbout2656-1VICINITY MAP
N.T.S.
I
1-1
QUANTITIES
r NO.
ESTIMATED
UNIT
ITEM
1
1451
SF
6" CONCRETE DRIVEWAY APPROACH PER STD DRAWING 102-C
2
1210
SF
3" A.C. PAVING OVER 4" AGGREGATE BASE
3
66
LF
6" CONCRETE CURB PER STD DRAWING 101
4
3
EA
REMOVE EXISTING DRIVEWAY APPROACH
5
986
SF
REMOVE EXISTING A.C. PAVING
6
147
LF
REMOVE EXISTING 6" CONCRETE CURB
7
166
LF
SAW CUT EXISTING PAVING
8
298
SF
4" A.C. PAVING OVER 6" AGGREGATE BASE
9
65
LF
REMOVE EXISTING CURB AND GUTTER
10
1
EA
"RIGHT TURN ONLY" SIGN R41 PER W.A.T.C.H. MANUAL
11
1
EA
"NO LEFT TURN" SIGN R17 PER W.A.T.C.H. MANUAL
CONSTRUCTION NOTES:
CONSTRUCT 6" CONCRETE DRIVEWAY APPROACH PER STD DRAWING 102-C.
CONSTRUCT 3" A.C. PAVING OVER 4" AGGREGATE BASE
3 CONSTRUCT 6" CONCRETE CURB PER STD DRAWING 101
a- REMOVE EXISTING DRIVEWAY APPROACH
5 REMOVE EXISTING A.C. PAVING
6a--- REMOVE EXISTING 6" CONCRETE CURB 7 -'SAW CUT EXISTING PAVING
BD_CONSTRUCT 4" A.C. PAVING OVER 6" AGGREGATE BASE
a REMOVE EXISTING CURB & GUTTER
910 --INSTALL "RIGHT TURN ONLY" SIGN R41 PER W.A.T.C.H. MANUAL
11 INSTALL "NO LEFT TURN" SIGN R17 PER W.A.T.C.H. MANUAL
LEGEND
TC .................................. TOP OF CURB
FL .................................. FLOW LINE
FS .................................. FINISHED SURFACE
R/W................................. RIGHT-OF-WAY
CF.................................. CURB FACE
W .................................. WATER LINE
O • • • • • • • • • ....................... CONSTRUCTION NOTES
NEW CURB
EXISTING CURB
REMOVE A.C. PAVING
& EXISTING DRIVEWAY
NEW DRIVEWAY
NEW A.C. PAVING
SAW CUT & REPLACE
DATE I BY
REVISION
GENERAL NOTES:
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS
AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS
DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY
STANDARD SPECIFICATIONS.
2. EXCAVATION AND CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC
WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS.
3. THE CONTRACTOR SHALL OBTAIN A PERMIT FROM THE CITY OF FONTANA FOR WORK
WITHIN THE CITY RIGHT-OF-WAY.
4. PAVEMENT SECTIONS SHOWN ARE MINIMUMAND SUBJECTTO REVISION AND APPROVAL
OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH
GRADING.
5. LOCATIONS OF PUBLIC UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
DETERMINE THE TRUE LOCATION AND ELEVATION IN THE FIELD OF ANY EXISTING
UTILITIES AND TO EXERCISE PROPER PRECAUTIONS TO AVOID INJURY OR DAMAGE
THERETO. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT FOR UTILITY
LOCATION BEFORE EXCAVATION AT 1-800-422-4133.
6. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129.
7. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND
OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE,
ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, AND STORM DRAINAGE, FLOOD
CONTROL SYSTEMS, ETC.
8. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF
FONTANA.
9. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS WILL BE DETERMINED
AT THE TIME OF CONSTRUCTION AND SHALL CONFORM WITH THE CITY OF FONTANA
STANDARD DETAILS.
10. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS,
AND WHERE THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATELY REPORT SAID
CONFLICT OR POSSIBLE CONFLICT TO THE OWNER'S REPRESENTATIVE.
11. STERILANT REQUIRED UNDER ALL A.C. PAVEMENT.
12. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S
INSPECTOR.
13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR SO AS NOT TO CAUSE
AND MUD, SILT, OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR ADJACENT PROPERTY
AT ALL TIMES DURING CONSTRUCTION. ANY MUD OR DEBRIS ON PUBLIC PROPERTY
SHALL BE REMOVED IMMEDIATELY. DUST SHALL BE CONTROLLED BY WATERING OR
OTHER APPROVED METHOD THROUGHOUT THE GRADING AND CONSTRUCTION
OPERATIONS.
14. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND
OTHER IMPROVEMENTS INCLUDING, BUT MOT LIMITEID TO, GAS, TELEPHONE,
ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL
SYSTEMS, ETC. 48 HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY:
CITY OF FONTANA
8353 SIERRA AVE
FONTANA, CALIFORNIA 92335
TELEPHONE (909)350-7610
SO. CALIF. GAS COMPANY
1981 W. LUGONIA AVENUE
REDLANDS, CALIFORNIA 92374
TELEPHONE (909)884-9411
SOUTHERN CALIFORNIA EDISON CO.
300 N. PEPPER AVE.
RIALTO, CALIFORNIA 92376
TELEPHONE
(909)820-5598 - UNDERGROUND
(909)875-5100 - TRANSMISSION
(213)637-1233 - PIPELINES, OR
(800) 422-4133
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN VIEW AVE.
POMONA, CALIFORNIA 91766
TELEPHONE (213)357-2257 OR
(800) 422-4133
4 Southland Engineering_
� EXP. 3.31 1
2200 BUSINESS WAY, STE. 100
clv% RIVERSIDE, CA. 92501
C ,COQ` UF
(909) 78 -8488
PREPA D R TSU RVIS N OF
gzl ALLENNW.AVARTIN DAIE
DATE I APPR. R.C.E. 38463 EXP. 3-31 1
SAN BERNARDINO FLOOD CONTROL
825 EAST THIRD STREET
SAN BERNARDINO, CALIFORNIA 92408
' TELEPHONE (909)383-1665
PACIFIC TELEPHONE & TELEGRAPH COMPANY
3939 CORONADO STREET
ANAHEIM, CALIFORNIA 92807
TELEPHONE (714) 999-5514
UNDERGROUND SERVICE ALERT
TELEPHONE (800) 422-4133
GROUP W CABLE
8561 NUEVO AVE
FONTANA, CALIFORNIA 92335
TELEPHONE (909) 350-2344
FONTANA WATER COMPANY
16803 SPRING ST.
FONTANA, CALIFORNIA 92335
(909) 822-2201
CITY OF FONTANA
PUBLIC WORK DEPARTMENT
DESIGN BY:
AWM
DRAWN BY:
AR
98130
E:
110162 MULBERRY AVENUE SCALE:
SCALE
TITLE SHEET
SANTA ANA AVE. & MULBERRY AVE.
CHECKED BY:
AWM APPW BY:
DATE:
JULY 1998
DWG. NO �