Loading...
HomeMy WebLinkAbout2655-1STREET IMPROVEMENTS NOTES: 1. ALL WORK SHOWN HEREON SHALL BE DONE IN ACCORDANCE WITH THE LASTEST EDITION OF THE "STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION", ("GREEN BOOK"), INCLUDING ALL SUPPLEMENTS AS WRITTEN AND PROMULGATED BY THE JOINT COOPERATIVE, COMMITTEE OF THE SOUTHERN CALIFORNIA CHAPTER OF THE AMERICAN PUBLIC WORKS ASSOCIATION AND THE SOUTHERN CALIFORNIA DISTRICT OF THE ASSOCIATED GENERAL CONTRACTORS OF CALIFORNIA, WITH THE CITY OF FONTANA STANDARDS AND SPECIFICATIONS, AND CHAPTER 33 OF THE BUILDING CODE, LATEST EDITION. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. CURB DATA REFERS TO THE FACE OF THE CURB. 5. ALL EXPOSED CONCRETE SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 6. ACTUAL THICKNESS OF A. C. PAVEMENT AND/OR BASE COUSE MATERIAL FOR STRUCTURAL STREET SECTION SHALL BE RECOMMENDED BY A GEOTECHNICAL ENGINEERING REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 7. PAVEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH GRADING. SUBGRADE PREPARATION SHALL BE DONE PURSUANT TO SECTION 301-1.2 OF STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (LATEST EDITION) SPECIFIED AS FOLLOWS: AFTER ROUGH GRADING HAS BEEN COMPLETED, WHEN SCARIFYING AND CULTIVATING ARE REQUIRED, THE ROADBED SHALL BE LOOSENED TO A DEPTH OF AT LEAST 6 INCHES. THE LOOSENED MATERIAL SHALL THEN BE WORKED TO A FINELY DIVIDED CONDITION AND ALL ROCKS LARGER THAN 3 INCHES IN DIAMETER SHALL BE REMOVED. 8. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRED TEMPORARY GUNITE SWALES, ENTERING OR LEAVING IMPROVEMENTS 9. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF THE STREETS. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. 11. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL OF THE AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS. 12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 13. ALL VALVE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY WATER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 14. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 15. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 16. RECORD DRAWINGS SHALL BE PROVIDED BY THE ENGINEER TO THE CITY OF FONTANA. 17. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM WITH THE CITY OF FONTANA STANDARD DETAILS. 18. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATELY REPORT SAID CONFLICT OR POSSIBLE CONFLICT TO THE OWNER'S REPRESENTATIVE. 19. STERILANT SOIL REQUIRED UNDER ALL NEW A. C. PAVEMENT. 20. NO CONCRETE SHALL BE PLACED UNTIL FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO WORKING AROUND THEIR FACILITIES. 22. ALL BACKFILL COMPACTION TO BE CERTIFIED BY SOILS ENGINEER AT NO COST TO THE CITY. 23. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 24. BACKFILL MATERIALS SHALL BE VERIFIED BY SOILS ENGINEER AND APPROVED BY PUBLIC WORKS INSPECTOR PRIOR TO THE PLACING OF ANY PERMANENT PAVEMENT. 25. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING PER PLANS OR AS REQUIRED BY THE CITY ENGINEER. 26. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE. LEFT 11UNTER ) S RID GE, TURN POCKET PARK , ff, 0 NN LL_.,/11ERRY AVENUE STA* 44+24.87 TO STA. 46 + 14*87 � PROJECT LOCATION STRIPING GENERAL NOTES-: 1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS AND THE STANDARDS AND SPECIFICATIONS FOR THE CITY OF FONTANA AND THE STANDARDS AND SPECIFICATIONS OF THE STATE OF CALIFORNIA. 2. PAVEMENT MARKERS AND TRAFFIC STRIPING DIMENSIONS SHALL CONFORM TO CALTRANS STANDARD PLANS. 3. PAVEMENT MARKINGS SHALL CONFORM TO CITY STANDARD STENCILS. 4. TRAFFIC STRIPING AND PAVEMENT MARKINGS ON NEW SURFACES SHALL BE THERMOPLASTIC (ALKYD TYPE) 5. TRAFFIC SIGN DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATION SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CALTRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD, UNLESS OTHER- WISE INDICATED ON PLANS. 6. SIGN SHALL BE MOUNTED ON STEEL POST PER CITY STANDARD N0. 139. LENGTH MAY VARY WITH SIGN INSTALLATION TO MAINTAIN MINIMUM HEIGHTS. 7, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL AT ALL TIMES. g, CONTROL POINTS OR "CAT -TRACKING" IS TO BE APPROVED BY THE TRAFFIC SECTION TWO WORKING DAYS PRIOR TO STRIPING APPLICATION. 9. EXACT LOCATION OF ALL EQUIPMENT AND CONTROL DEVICES SHALL BE APPROVED BY THE ENGINEER. ADDITIONAL WARNING AND/ OR CONSTRUCTION STRIPING &SIGNS MAY BE REQUIRED BY THE ENGINEER. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. Underground Service Alert Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG CONSTRUCTION SITE BENCHMARK: ELEV. 1559.964 SET BRASS CAP IN TOP OF THE FLOOD CONTROL CHANNEL HEADWALL OVER THE HAWKER CRAWFORD CHANNEL BRIDGE, NORTH SIDE OF CHANNEL BENCHMARK: ELEV. 1313.04 FWE 43 - RAILROAD SPIKE IN E.P. BY PP#1536663E SLY. SIDE OF BASELINE 220' E'LY. OF CHERRY AVE. BASIS OF _BEARINGS: THE NORTH LINE OF THE NORTHWEST ONE HALF OF SECTION 23, TOWNSHIP 1 NORTH, RANGE 6 WEST, S.B.M. BEING N89°50'00"E PER TRACT NO. 13750 RECORDED IN BOOK 250, PAGES 48 THROUGH 66 OF MAPS, RECORDS OF SAN BERNARDINO COUNTY. LEGAL DESCRIPTION: TRACT NO. 13750 IN THE CITY OF FONTANA, COUNTY OF SAN BERNARDINO, CALIFORNIA, PER AMENDING MAP RECORDED BOOK 250, PAGES 48 TO 66, INCLUSIVE, RECORDS OF SAN BERNARDINO COUNTY. UTILITY PURVEYORS: ELECTRICITY SOUTHERN CALIFORNIA EDISON CO. DISTRIBUTION PLANNING 7951 REDWOOD AVENUE FONTANA, CA 92336 (909) 357-6562 CONTACT: ARMANDO GONZALES GAS SOUTHERN CALIFORNIA GAS CO. DISTRIBUTION PLANNING 16231 VALLEY BOULEVARD FONTANA, CA 92335 (909) 428-8402 CONTACT: DAVID PADILLA W- FONTANA WATER COMPANY 8440 NUEVO AVENUE FONTANA, CA 92335 (909) 882-2201 SEWER CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-7610 OWNER /DEVELOPER ALPER DEVELOPMENT 1101 CALIFORNIA AVENUE, #205 CORONA, CA 91719 (909) 739-6100 CONTACT: CRAIG SWARTS COMCAST CABLEVISION 1205 DUPONT STREET ONTARIO, CA 91761 (909) 988-8322 X3055 CONTACT: JACK HAYES VICINITY MAP N.T.S. MARKS CABLEVISION FIBER -OPTICS/ TRUNK LINK THROUGH PROJECT 4240 HALLMARK PARKWAY SAN BERNARDINO, CA 92407 (909) 880-0220 CONTACT: JOE DEARMAN GTE CALIFORNIA. INC. CAB20VF 870 NORTH MOUNTAIN AVENUE UPLAND, CA 91786 (909) 931-2472 CONTACT: DANIEL TUCKER WI LTEL. INC. FIBER-OPTIC TELECOMMUNICATIONS LAS VEGAS, NEVADA TO LOS ANGELES, CA UPLAND, CA 91786 P.O. BOX 21348, MD 26-3 TULSA, OK 74121 918) 588-3397 909) 947-9441 (LOCAL CONTACT) LOCAL CONTACT: JERRY KENNEDY CONSTRUCTION NOTES & QUANTITIES: ITEM DESCRIPTION QUANTITY UNIT 1 CONST. 5;) AC OVER 6.5 AB OVER 12" OF 95% COMPACTED NATVE SEE STREET IMPROVEMENTS GENERAL NOTES NO. 6 & 7 HEREON 76 TONS 1208 CY �2 CONST. 6" PCC CURB & GUTTER PER CITY OF FONTANA STD. NO. 101 241 LF 3 SAWCUT AND REMOVE EXISTING CURB, MEDIAN AND A.C. PAVEMENT. PAVING SHALL BE REMOVED TO WITHIN 1' OF THE CURB 2,415 SF 4 APPLY 8" SOLID WHITE CHANNELIZING LINE PER CALTRANS TRAFFIC DETAIL NO. 38 88 SF �5 APPLY IV(R) SOLID WHITE ARROW AS SHOWN 1 EA �6 PLACE R7 SIGN WITH TYPE K MARKER 1 EA OCONSTRUCT COBBLESTONE MEDIAN TREATMENT PER CITY OF FONTANA STD. NO. 145. 570 SF CI 0 00 0 �ro mo NO �Cd rro 0T__ VICINITY r -