HomeMy WebLinkAbout2605-xxa r 4 L s FLUORESCENT FIXTURE FLEX CONDUIT 7,. FLUORESCENT STRIP FIXTURE .--_-- _ CONDUIT UNDER SLAB 1. THE ENTIRE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE 1993 g _ OR BELOW GRADE NEC, ISTATE FIRE MARSHALL REGULATIONS, AND ALL OTHER ORDINANCES HAVING JURISDICTION. 9 (TYP 2} 9 3 Y h.fx ® RECESSED DOWNLIGHT S SINGLE PALE SWITCH I 2. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTION - - - - `` 0 SURFACE MOUNTED FIXTURE S2 DOUBLE POLE SWITCH REQUIREMENTS. WALL MOUNTED FIXTURE S3 THREE WAY SWITCH 3. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR MATERIALS INSURANCE 1 EQUIPMENT INSTALLATION CONSTRUCTION TOOLS TRANSPORTATION, T 3 EXIT FIXTURE S. FOUR WAY SWITCH � R , ETC. FOR A TYP 11 4 COMPLETE INSTALLATION. ( ) EXIT FIXTURE -WALL MTD. SD DIMMER SWITCH 4. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN _ INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER 11 11 11 JUNCTION BOX Sm MANUAL MOTOR SWITCH THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT. MATERIALS SHALL BE 3 4 j LISTED AND APPROVED BY UNDERWRITERS LABORATORY AND SHALL BEAR THE ILI { >0 FLOODLIGHT FIXTURE SP SWITCH WITH PILOT LIGHT INSPECTION LABEL U.L. WHERE SUBJECT TO SUCH APPROVAL. 1 1 9 9 DUPLEX OUTLET ST TIMER SWITCH 5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING CONDITIONS I 11 11 AND DIMENSIONS. HE SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE I }- DUPLEX OUTLET -1/2 SWITCHED T TRANSFORMER -AS NOTED OWNER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. DUPLEX OUTLET -20 AMP. DISCONNECT SWITCH 6. ALL WIRING SHALL BE IN METALLIC CONDUIT (NON-RESIDENTIAL). RIGID m GALVANIZED CONDUIT SHALL BE USED IN OR UNDER CONCRETE SLABS ON GRADE, 11 11 < DOUBLE DUPLEX OUTLET VN MAGNETIC MOTOR STARTER WHERE EXPOSED TO WEATHER, AND WHERE SUBJECT TO MECHANICAL DAMAGE. E.M.T. CONDUIT SHALL BE USED FOR INTERIOR WIRING WHERE NOT SUBJECT TO E Q FLOOR OUTLET AS NOTED COMBINATION STARTER MECHANICAL DAMAGE. FLEXIBLE CONDUIT SHALL BE USED WHERE THE 11 11 {: ol' STRUCTURAL CONDITIONS MAKE THE USE OF E.M.T. IMPRACTICABLE AND FOR SHORT OF 5 Y CONNECTIONS TO LIGHTING FIXTURES AND OTHER VIBRATING EQUIPMENT. USE (TYP) 9 g OUTLET -AS NOTED ---- ,■� FLUSH MTD. PANEL - NEOPRENE JACKETED FLEXIBLE CONDUIT AND FITTINGS WHERE EXPOSED TO Q CLOCK OUTLET ■■■� SURFACE MTD. PANEL WEATHER. a Q THERMOSTAT MAIN SWITCHBOARD 7. ALL CONDUCTORS SHALL BE COPPER AND RATED 600 VOLTS. SIZES NO. 10 AWG AND LARGER SHALL BE STRANDED AND NO. 12 AWG AND SMALLER SHALL BE SOLID. USE I 4 1 F VENT FAN OUTLET � TELEPHONE OUTLET -WALL MTD. TYPE TH H N /TH WN f TH W. I I (TYP) MOTOR OUTLET C� TELEPHONE FLOOR OUTLET 8. ALL CONDUIT PENETRATIONS THRU FIRE -RATED FLOOR SLABS, SHAFTS, AND WALLS i 1 TL Os SPEAKER OUTLET SHALL BE SEALED AGAINST THE SPREAD OF FIRE OR SMOKE WITH APPROVED CABLE F1 DENOTES FIXTURE F-1 AND CONDUIT FIRE STOPS OR FIRE-RESISTANT SEALANT TO GIVE THE EQUIVALENT I g g n TV OUTLET - FIRE RATING BEFORE THE PENETRATION. I> DATA OUTLET N.L. NIGHT LIGHT 9. VERIFY EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL OUTLETS WITH 1 F - ►� I I 1 11 = Q SMOKE DETECTOR W.P. WEATHERPROOF ARCHITECT AND OWNER PRIOR TO ROUGH -IN (MINIMUM HEIGHT TO BE +15 AFF). I I _ it -}i�- 1/2"C-3#1 2 C.O. CONDUIT ONLY W/ 1/4 10, PROVIDE NYLON PULL WIRES IN ALL TELEPHONE AND EMPTY CONDUITS. POLYPR. ROPE I i --H-I�- 1/2"C-4#12 11. PROVIDE SEPARATE GROUND WIRE IN ALL FLEX CONDUITS AND NON-METALLIC ► 1 E.P. EXPLOSION PROOF CONDUITS. 3/4"C-5#1 (TYP) I I 9 �--2 F.A. FIRE ALARM 9 L i 12. THE CONTRACTOR SHALL MAINTAIN THE UNIFORMITY AND CONTINUITY OF THE ---Eii-Hi- 3/4"C-6#1 2 E.D.F. ELECTRICAL DRINKING FOUNTAIN GROUNDING SYSTEM. 9 --}�}H- 3/4"C-7#1 2 E.O.L. END OF LINE DEVICE 13. E.C. SHALL VERIFY UTILITY CO. INFORMATION AND INCLUDE SAME IN HIS BID. - --------------------- ------------ - - - ----- - - - - -- --------------------------- ------ ---------------- A.F.F. ABOVE FINISHED FLOOR , 3/4"C-8#12 14. ALL RECEPTACLES WITHIN 6 OF A WATER SOURCE SHALL BE GFI PROTECTED. A.F.G. ABOVE FINISHED GRADE <1 Hi" -nor- 1$'C-9#1 2 U.O.N. UNLESS OTHERWISE NOTED. G.F.I. GROUND FAULT INT. SCALE 1/4"=1'-0" SYMBOL LIST GENERAL NOTES LIGHTING PLAN TC I05 MOUNTING: VOLTAGE: SURFACE 120/208V,--3PH-4W PANEL "A" N BUS MAIN SIZE: 100A TYPE: 100A C/B LOCATION WATTS/PHASE A B C C/B SIZE CKT. NO. C/B SIZE WATTS/PHASE A B 'C LOCATION CONCESSION REC 1500 20 1 1 2 20 1 1500 -x HAND DRYER 1500 3 4 ui z 5 EN 1500 HAND DRYER 1500 5 6 N Z)0 to a SPACE CONV OUTLETS 360 7 — 8 EXTERIOR LIGHTING 630 9 10 INTERIOR LIGHTING 896 11 12 SPACE 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 TOTAL 1860 21302396 EE 1500 1500 TOTAL LCL AC LCL MISC. LOAD TOTAL LOAD 1526 W X 1.25 = -- W X 1.25 = = - 1908 -- 7860 9768 W W W W = 27 3360 AMPS 3630 2396 PH ASE TOTAL 9386 TOTAL WATTS 0 120/208V-3PH-4W 4 2 J � J I 2 `\ 2 i „A„_1.3.5-7 Fff2 FLAIR AROHITECTS EXPRE8SLEY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE A88IONED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMIS81ON AND CONSENT OF FLAIR ARCHITEOTS. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY $HALL HOLD FLAIR ARCHITECTS HARMLESS. ■ ■ W c N N 00 to 0 N OQ¢ _ -x i1 Q U 2.� c_ ui z 5 EN p N Z)0 to a 4-1D U Z I Q; ._ a 00 0 L0 FLAIR AROHITECTS EXPRE8SLEY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE PLANS, THESE PLANS ARE NOT TO BE REPRODUCED, CHANGED, OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE A88IONED TO A THIRD PARTY WITHOUT FIRST OBTAINING THE WRITTEN PERMIS81ON AND CONSENT OF FLAIR ARCHITEOTS. IN THE EVENT OF UNAUTHORIZED REUSE OF THESE PLANS BY A THIRD PARTY, THE THIRD PARTY $HALL HOLD FLAIR ARCHITECTS HARMLESS. ■ ■ W U Lu 0 m z 0 EE U 0 W w m ■ ■ JOB NO. 97006 CITY DWG. NO. xxxx 1st SUBMITTAL 6-2-97 FLOOR PLAN 1A E1.1