HomeMy WebLinkAbout2605-9CMU WALL
ROLL -UP COUNTER
HOOD COIL AND
N \
r
Lo �GI. FLASHING MTL. CAP \ CMU WALL
SLOPE TO DRAIN
EXTERIOR �1 INTERIOR EXTERIOR
8 X 12 BEAMS 2X6 WD TRIM 0/ 2X10
WD. TRIM
C3
w
MASONRY ANCHOR
d /
W ELA3TOMERIC SHEET WATER -
3 X8 TRELLIS PROOFING
MORTAR SETTING BED 04 SEALANT
` STUCCO STONE VENEER N STEEL DOOR FRAME
d CMU PILASTER
W
DOOR GUIDE -SEE DOOR PER SCHEDULE
2. C3i` SEE PIANS JAMB DETAIL
8 X 8 OUTLOOKERS
20 21 TRELLIS DETAILS 16 COLUMN CAP AT TRELLIS 11 ROLL— UP DOOR HEAD 6 EXTERIOR DOOR HEAD 1
ROOF FRAMING
SEE STRUCTURAL EXTERIOR
ROOF TILE DOOR PER SCHEDULE
//__72 LB MINERAL GRIT STEEL DOOR FRAME
FIBERGLASS CAP
SHT 0/ 30 LB EDGE OF COUNTER SEALANT
ASTM ROOFING FELT
MASONRY ANCHOR
PER CMU WALL CMU WALL
TILE EXTERIOR
MFR.
1X2
STARTER
STRIP
METAL Ir
DRIP
EDGE
CMU WALL
FASCIA
SEE ELEVATIONS
NOTE: REFER TO ROOF 2x BLOCINQ W!DOOR GUIDE
TILE MANUFACTURERS (4) 2' DIA, BY MANUF,
SPECIFICATIONS FOR SCREENED VENT
INSTALLATION OF TILE PER PLAN BOOK PER ROLL -UP DOOR INTERIOR
PER I080 # NER--519
2 24 17 EAVE 1 ROLL— UP --
DOOR JAMB 7 EXTERIOR DOOR JAMB 2
RIDGE OR HIP TILE DOOR PER SCHEDULE
PASTERNS SHALL BE
• LONG ENOUGH TO - EDGE OF COUNTER STEEL DOOR FRAME
PENETRATE THRU
RIDGE, FIELD TILES, AND
INTO DECKING 1/2' MIN.
AMERICAN CEMWOOD
TILE: ROYAL SHAKE
UNDERLAYMENT SEALANT
CMU WALL BEYOND
ROOF SHEATHING
EXTERIOR ROLL -UP COUNTER Ir
DOOR W/ WEATHER -
ROOF FRAMING,
STRIP BOTTOM BAR
SEE STRUCTURAL
MASONRY ANCHOR
DOOR GUIDE
SEE JAMB DETAIL
CMU WALL
NOTE: REFER TO ROOF STAINLESS STEEL
TILE MANUFACTURERS COUNTER - SEE
SPECIFICATIONS FOR COUNTER DETAIL
INSTALLATION OF TILE
PER IC80 i NER-519
21 2 18 RIDGE/HIP 13 ROLL—UP DOOR @ COUNTER 8___
EXTERIOR DOOR JAMB 3
•
CMU WALL
INTERIOR EXTERIOR
DOOR PER SCHEDULE
STEEL DOOR FRAME
PEMKO 4217 DOOR
ALUMINUM FIXED BOTTOM (OR EQUAL)
2X6 WD TRIM 0/ 2X10 INSECT SCREEN
WD. TRIM CONCRETE SLAB
INTERIOR I EXTERIOR CONCRETE WALKAS OCCURS
SLOPE 1/4'/FT. MAX.
FOR 5'-0' MIN.
BUILDING PAPER ALUMINUM FIXED LOUVER
PANELS, FABRICATED TO
MORTAR SETTING BED � FIT THE OPENINGS. SELF LEVELING SEALANT
STUCCO STONE VENEER EXPANSION JOINT FILLER
CMU PILASTER FULL DEPTH OF SLAB
PROVIDE LOUVERS ON
EACH SIDE OPENING
FOR VISUAL PRIVACY
29 2 19 COLUMN CAP 14 WALL VENT 9 EXT. DOOR THRESHOLD 4
3'-0'
STAINLESS STEEL COUNTE
0/ 1 1/8' PLYWOOD
STUCCO STONE VENEER
2X TOP PLATE ANCHORED
MORTAR SETTING BED I TO TOP OF CMU WALL
O 2x4
CMU WALL /PILASTER `--2X4 TRIM AT
COUNTER EDGE
SEALANT
FOUNDATION -SEE 1 1/2• DIA. STAINLESS
STRUCTURAL � - FIXED ALUMINUM BLADE LOUVER -
SEE WALL VENT DETAIL FOR X STEEL LEGS W/ ADJUST -
co ADDITIONAL INFORMATION.
N ALIGN OPENING WITH GLASS � MAX. (ENEVLY SP,ACED)C
BLOCK WINDOWS. o ;o
� a N N $� 1/8' ACX PLYWOOD
I (PAINTED lX3 EDGE TRIM
a
� O SURFACE MOUNTED STAINLESS 2X4 CONT. D,F.P,T. CLEAT
a I STEEL SCREWS SET INTO LEAD SET TO WALL WITH 3/8'
FINISH GRADE EXPANSION SHIELD IN CMU COUNTERSUNK BOLTS
� a ��:`� ' � 8 PER PANEL EVENLY SPACED. AT 24. O.C.
4.
—III—III—III—III—III FLAT STAINLESS STEEL
� .PLATE WELDED TO LEGS
2'-8' 1/2'
FOR SHELF SUPPORT
3 25 21 STUCCO STONE AT GRADE 15 FIXED LOUVER ELEVATION 1 CONCESSION COUNTER 5 �
■
■ ■
FLAIR ARCHITECTS EXPRESSLEY RESERVES
ITS COMMON LAW COPYRIGHT AND OTHER
PROPERTY RIGHTS IN THESE PLANS.
THESE PLANS ARE NOT TO BE
REPRODUCED, CHANGED, OR COPIED IN ANY
FORM OR MANNER WHATSOEVER, NOR ARE
THEY TO BE ASSIGNED TO A THIRD PARTY
WITHOUT FIRST OBTAINING THE WRITTEN
PERMISSION AND CONSENT OF FLAIR
ARCHITECTS. IN THE EVENT OF
UNAUTHORIZED REUSE OF THESE PLANS BY
A, THIRD- PARTY, THE THIRD PARTY SHALL
-'HOLD FLAIR ARCHITECTS HARMLESS.
w
co
W
oC
ui
0)
Z
W •
> tlo
it
=jo
CL ca
2oco-
Cf) 0 tr. .._I (.)<
LLJ _
w o u. z
OU6 >(a)
0 a.
LLJ c
V W
Fm �m W. �QJ
F- Lu
< a: Z (D
Z C/)Z
Q WC'f)<
CL Z J tri
o r0
LL <v=.J
■
■
JOB NO.
97006
CITY DWG. NO.
2nd SUBMITTAL
11-24-97
ARCHITECTURAL
DETAILS
■ ■
""111
1111111'
■
■
JOB NO.
97006
CITY DWG. NO.
2nd SUBMITTAL
11-24-97
ARCHITECTURAL
DETAILS
■ ■