HomeMy WebLinkAbout2600-1M.H.
m"
JURUPA AVENUE
28 27 26 25 24 23 22 21 20 19
--'07
.01
SEE SHEET 3 BRANDON LANE J
29\:
M.H. #7
nrr M.H. #8
30 �
a M
WI
31 2 z
NI
W IW
32
M.H. #3
1 2I 3
36 37 38 39 �
34
46 45 44 43
33 M.H. #
SEE SHEET 2 COLEEN ST
4 5 6 7 8 9
INDEX MAP_
SCALE: 1"=100'
18
_J,� SEE SHEET 3
M.H. #9
17
40
W
En Z 166
41
u
15
M. H. #5
42
INSTALL 4" SEWER LATERAL PER CITY OF FONTANA STANDARD
13 14
10 11 12
CONSTRUCTION NOTES 8 QUANTITIES
kin ITFM QUAN11TY UNIT
ABANDON SEWER
PER DETAILS, SHT 2
1
INSTALL STANDARD MANHOLE PER CITY OF FONTANA STANDARD DETAIL 112.
8
EA.
INSTALL 8" VITRIFIED CLAY PIPE PER CITY OF FONTANA STANDARDS
1,817
LF
AND SPECIFICATIONS
INSTALL 4" SEWER LATERAL PER CITY OF FONTANA STANDARD
46
EA
DETAIL 125.
JOIN EXISTING SEWER MANHOLE
1
EA
G)
ABANDON EXISTING 8" SEWER BY EITHER REMOVAL OR FILLING
9Q0
LF
WITH AIR BLOWN SAND.
OREMOVE
UPPER 4' OF EXISTING SEWER MANHOLE. FILL REMAINDER
900
LF
WITH SAND.
_. ., .. .�.•,:. :�- r ,. : i , ;: E, .. ,, ,,;;, :,;:r. !,: it .•;,�..,. [PLANS ;..';'; :I I I' I ;..��.,"JIT. 4' IL I,.1.. 1 ..II II. is I I :.il 1:, ' ',I �I, (, I I .I II .I -1, :'II i l:l i,l is , I. IIi: � I. II,II'�'.. I i �' isIj I'' ;,','il��;,�:I,I)�I LIII � i ,I I,,III:_.. I ll;I II�II��: �:�'�JiIIIi..II I ,: I, ; � ,, , ,I: � I;ir•II.!�II,, III I ';;IIS;,u I � �:,, : 1'' L:�. I I : I I .1 I ', I�LI I: !�IP 'll I I:cl ,,, I I, � !'i I I', ;I iI; 1, I I � 1,u' ;'� IIr' in �: i'�'i 'II i :! ; ! " I `' � i.l l ,.: �:. � � II �;; I '+ i• ) �I:�Ili�r; I l r • I: � IIL I, , I ,, ,; � I ' I � ::r„ , i , �', �I ,, r:I, 11.;I', I,:':I IIII•( I I III r!II ,,. rl!: ;J', _,,,,, 1 �.: ,,�, !I,,i,.l.l i,.: � II,:,, I,LII,: ::� .,. �.: � LI ,II III':. _�,: ,.I, I
00
FRAU
I
I
� I i II .I
11
I .
R/W CL RIW
29/
owl�
! i 10' I
M.H.
BENCH MARK
BM 248A ELEVA1I0N=952.17
SPIKE INSIDE OF POWER POLE, NORTH SIDE OF JURUPA AVENUE
75' WEST OF LIVE OAK AVE AT POWER POLE #363E.
EX 78" RCP;—
a�
PRnP 8" SEWER
CONTRACTOR SHALL PROTECT
ADJACENT WATER AND STORM
DRAIN LINES BY SHORING OR
OTHER MEANS ACCEPABLE TO
THE CITY OF FONTANA.
TYPICAL SECTION BEECH AVE
NO SCALE
3" MAX SIZE NATIVE
SOIL, COMPACTED TO
95% R.C.
EX 16" WATER
6" MIN 6" MIN
10" MAX 10" MAX
r
N
r
6" MAX SIZE NATIVE
SOIL COMPACTED TO
90% R.C.
1" MAX SIZE SELECTED
NATIVE BEDDING COMPACTED
TO 90% R.C.
UNDISTURBED EARTH
FOR TRENCHES DEEPER THAN 10' USE
CRUSHED ROCK GRADED AS FOLLOWS:
SIEVE SIZE PERCENT PASSING
3/4" 100
1/2" 90-100
3/8" 20-60
NO 4 0-15
NO 8 0-15
ASTM C131 TEST GRADING
Emmori'liis
I bili 7 - zcmm� � 1��
8" V.C.P.
TYPI0% CAL TRENCH BEDDING
NO SCALE
EDGE OF TRENCH
GENERAL CONSTRUCTION NOTES
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD
SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA AND STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN
BOOK), LATEST REVISIONS.
2. CONSTRUCTION PERMITS SHALL BE OBTAIANED FROM FONTANA ENGINEERING DIVISION PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS.
3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED.
4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS.
5. EXISTING UNDERGROUND UTILITIES ARE AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL
LOCATION AND ELEVATION IN THE FIELD.
6. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GAURDED BY A SHORING SYSTEM,
SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GAURDED WHEN
EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED.
7. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1 I. 6.
8. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129.
9. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES.
CONTRACTOR SHALL NOTIFY THE ENGINEER 48 -HOURS PRIOR TO THE ANTICIPATED START OF CONSTRUCTION.
10. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD. RECORD DRAWINGS SHALL BE PROVIDED TO
THE CITY OF FONTANA.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, STREET CENTERLINE MONUMENTS, OR
BENCHMARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT.
12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL
BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING.
13. ALL 4" HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
INSTALL SEWER CLEANOUT BOX FOR ALL HOUSE LATERALS PER STD 125-A OR 125B.
14. TERMINATE ALL 4' HOUSE SEWER LATERALS INSIDE THE LOT WITH A PLUG. SHOULD A PUBLIC UTILITIES EASEMENT BE CONTIGUOUS TO THE
STREET R.O.W., THE LATERAL SHALL EXTEND ACROSS THE EASEMENT AND TERMINATE 3' INSIDE THE LOT AS MEASURED FROM THE UTILITY
EASEMENT LINE.
15. CHIS. X SHALL BE PLACED ON THE CURB OVER LOCATIONS OF SEWER LATERALS BY THE SEWER CONTRACTOR.
16. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE HORIZONTAL LOCATIONS AND VERTICAL ELEVATIONS OF ALL UTILITY
CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWER ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO
CONSTRUCTION.
17. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO,
GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM
DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES.
PD DRAWINGS
PREP D E :
ens elm m RCE 25742
ENGINEERS
221 S. Glassell Street
®range, CA 92866
(714) 744-9700
No. REVISIONS Approval's Approval Date PREPARED BY: Thielmann
Engineers
1078 TOWN AND COUNTRY ROAD
ORANGE, CA 92668
(714) 647-0595 FAX (714) 647-0599
2
JENS THIELMANN DATE
I Ar au I t r R. C.E. No. 25742 EXP. DATE 12/31/2001
UTILITY NOTIFICATIONS
CITY OF FONTANA
8353 SIERRA AVE
FONTANA CA 92335
TELEPHONE (909) 350-7610
SO.CALIF GAS COMPANY -- DISTRIBUTION FACILITIES
16231 VALLEY BLVD.
FONTANA, CA 92335
TELEPHONE (889-9711) OR (800) 422-4133
SO.CALIF GAS COMPANY -- TRASMISSION DEPARTMENT
2191 BIRCH STREET
BREA, CA 92621
TELEPHONE (909) 529-2889 OR (800) 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
909 357-6231SO. OF MERRILL)
909 357-6223 ((NO. OF MERRILL)
800 422-4133
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN AVENUE
POMONA, CA 91766
(213) 357-2257 OR (800)422-4133
SAN BERNARDINO COUNTY FLOOD CONTOL DISTRICT
825 E. THIRD STREET
SAN BERNARDINO, CA 92408
(909) 383-1665
PACIFIC TELEPHONE AND TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE, CA 92504
(714) 359-2585 OR (800)422-4133
FONTANA WATER COMPANY
8440 NUEVO AVENUE
P.O. BOX 987
FONTANA, CA 92334
(909) 822-2201
CITY OF FONTANA
Drawn By: SOUTHRIDGE VILLAGEScale:
GTT TRACT 15794
AS SHOWN
Designed By: Date:
JTT SEWER IMPROVEMENT PLANS APRIL 1998
Checked By: Dwg. No.
GTT 040CITY ENGINEER, RCE 25126 DATE 2Cp00