Loading...
HomeMy WebLinkAbout2548-1GENERAL MOTES: 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA AND STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK), LATEST EDITION. 2. CONSTRUCTION PERMITS SHALL ME 08TAINED FROM FONTANA ENGINEEERING DIVISION PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. ALL INSPECTIONS SHALL BE REQUESTED THROUGH THE CITY OF FONTANA ENGINEERING DIVISION AT LEAST 24 HOURS PRIOR TO THE START OF ANY WORK AT (909) 350-6632. 3. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE OTHERWISE NOTED. 4. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 5. NO CONCRETE SHALL BE PLACED UNTILL THE FORMS AND REINFORCING STEEL HAS BEEN PLACED, INSPECTED AND APPROVED. 5. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 7. EXISTING UNDERGROUND UTILITIES ARE PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION IN THE FIELD. S. THE WALLS AND FACES OF EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 9. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION! OR TRENCH -WORK AS DESCRIBED IN NOTE 8 ABOVE FROM CAL/OSHA. 10. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT TO FINISHED GRADE BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE. It. IMMEDIATELY FOLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB AND/OR GUTTER, THE CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION OF THE WORK TO COMPLETION. 12. ALL C.M.P. INSTALLATION AND CONNECTIONS SHALL BE MADE PER MANUFAC- TURER'S SUGGESTED METHOD UNLESS OTHERWISE SPECIFIED ON THE PLANS. 13. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER. 14. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 13. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH THE CITY STANDARD SPECIFICATIONS. 16. "AS -BUILT" PLANS SHALL BE PROVIDED TO THE ENGINEER OF RECORD 0Y THE CONTRACTOR. THE ENGINEER OF RECORD SHALL PROVIDE "RECORD DRAWING" TO THE CITY PRIOR TO CITY ACCEPTANCE OF THE STORM DRAIN SYSTEM. 18. CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6€32 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTN: DENNIS FREEMAN ATTN: JACK HAYES 1981 W. LUGONIA AVENUE 1205 DUPONT AVENUE REDLANDS, CA 92374 ONTARIO, CA 91761 (909) 335-7547 (909) 390-4738 EMERGENCIES: (800) 427-2200 GENERAL TELEPHONE COMPANY SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK 300 N. PEPPER AVENUE 1400 E. PHILLIPS BLVD. RIALTO, CA 92376 ONTARIO, CA 91765 (909) 820-5598 - UNDERGROUND (800) 422-4133 (909) 875-5100 - TRANSMISSIONS (213) 637-1233 - PIPELINES FONTANA WATER COMPANY (909) 357-6233 - DISTRIBUTION ATTN: MICHAEL J. MCGRAW (800) 422-4133 8440 NUEVO AVENUE FONTANA. CA 92335 CRAWFORD CANYON! MUTUAL WATER CO. (909) 822-2201 ATTN: BILL VANDERKIEFT, JR. FAX: (909) 823-5046 (619) 868-6040 UNDERGROUND SERVICE ALERT (800) 422-4133 • Calk TOLL FREE I msoo 422=41 33 TWO WORKING DAYS BEFORE YOU DIG PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON- SIBILITY FOR THE UTILITY ,PIPES. CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS." THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONfS- IBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. r MAX sac waNc 60 MIN. - I ) 0 s- MAX SAN HAW& !aw com dos •i' « r MIN* 1' I&M SIZE SELECTED NAIM f�11PA� TO 9 -ax TYPICAL BEDDING FOR R, C. P. STOM PRINT` INDEX MAP CONSTRUCTION NOTES: QUANTITIES: 10 INSTALL 34' DIA. R.C.P., D -LOAD PER PLAN. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .3G4 L. O2 INSTALL 21" DIA. R.C.P., D -LOAD PER PLAN. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ /04 4.f. O3 INSTALL If DIA. R.C.P., D -LOAD PER PLAN. _ _ _ _ _ _ _ _-- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -- _ _ _ G3 L.o` 4� CONSTRUCT CATCH BASIN PER APWA STD. PUN 300-1, W & V PER PLAN. SEE DETAIL ON SHT. N0. 4. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ FcA. OS CONSTRUCT MANtME PER AFWA STD. PLAN 322-0. / A. SEE DETAIL ON SHT. NO. 3.------- ------------------------------ A` O6 CONSTRUCT TRANSITION STRUCTURE PER APWA STD. PUN 340-0. SEE DETAIL ON SHT. N0. 3. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ / EII. �7 CONSTRUCT BRICK AND MORTAR PLUG PER SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT STD. S.P. 176A. SEE DETAIL ON SHT. N0. 3. _ _ _ _ _ _ _ _ _ _ _ _ _ _ / EA. O8 REMOVE BRICK AND MORTAR PLUG. JOIN EXISTING PIPE. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ / i.1 IW*STDHM DHAih i i iLE SMEEi - 21 l0. 2'551 ": 10W Nth 2V-UCt-91 11:27 AM / 126-1050-1 0.4 Tom: r'- 30 - 17 ,