Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2533-4
--------__— ---------------------- G W C&G T T • PHASE DIAGRAM 1 ARMS I PED PUSH i 9r2 1 94 COMMENTS C Tip` CIRCUI 1 LUM. 2r5 Z6 o-7 a 01iCLE P.- MESSAGE A B 0.-I 1 17-2-8050 20 15' 250 W B 2 N MAS SV --1–T SP -1 --CS Baseline Ave. 10 3.5 EXISTiNG 2 1--A 10 – – – B 4 E TV -1--T SP-4—CS – 1 8 4' EXISTING 3 26A-3-80 35 40' 15' 250 W B 4 E MAS, MAS, SV --1 SP -1 --CS Hemlock A -re. 0 15 EXISTING 4 1–A 10 -- – – B 6 S TV -1 SP--1--CS– 6 7 EXISTING 5A 19-3-80 30 25 13 250 W B 6 S MAS, S1i -1–T Sp -1 �CS Baseline Ave. –15' S EXISTING 5B PPB POST 3'10 – – – B 6 S – – – – – RELOCATE PPB TO r O� 5A SALVA.GE POST 6A 15 30 – 15 250 W B 8 W TV -4-T SP -4 -CS – 17 5 RELOCATE TO NEW POSITION 66 6B 15 50 – 15 250 W B 8 W TV -1–T SP–L� – 12 5 RELOCATE FROM POSI TION 6A 7 26-4-80 30 40 15 250 W B 2,8 N,W MAS,MAS,SV-2–T SP-1–CS Vi11age Pkwy, 0 1V EXISTING WPMEx"flM, --------__— ---------------------- G W C&G T T • PHASE DIAGRAM LSTANDARD 0 ARMS I PED PUSH i 9r2 93 94 COMMENTS C Tip` hT. 1 LUM. 2r5 Z6 o-7 a CONffRUCTM NOMS Selve" existing PPB Post to city yard. Existing pedestrian push button to be relocated to existing pole 5A. © Install Type 8 pedestrian push button on existing pole. 1. THE CONTRACTOR SHALL "JACK" ALL CONDUIT UNDER ALL ROADWAYS UNLESS ANOTHER METHOD IS APPROVED BY THE CITY ENGINEER. 2. STRIPING AND CHANNELIZATION SHALL RE PERFORMED BY THE CONTRACTOR. 1'1 20' NOTE: SEE APPROVED STREET AND STORM DRAIN PLANS FOR OTHER OFFSITE CONSTRUCTION. #6E EXIST. 2' C, 2 #10 PER CITY DRAWING NO. 2392 ♦ I t , ♦ I t l+ EXIST. 2' C, 2 #6 1 #8 PER CITY DRAWING NO. 2392 1 II r) i• J 1 EXIST, 3' PVC CONDUIT WITH PULLR0PE 1 INT❑ SERVICE PEDESTAL ADDRESS, 7326 VILLAGE PKWY 1 PER CITY DRAWING NO, 2392 1 EXIST. 1.5' PVC CONDUIT WITH PULLROPE TO TELEPHONE PEDESTAL AT SNAPDRAGON ' ST. APPROX. 500' SOUTH OF CONTROLLER PER CITY DRAWING NO. 2392 1-800-422-4133 IT'S THE LAW I CALL AT LEAST Two DIAL BEFORE WORKING DAYS PRIOR YOU DIG! TO EXCAVATING )A L�. UNDERGROUND SEERr C ALERT 110 WON EUCANATRIQ, TME CONTRACTOR IIAU WW V M LOCATIBN OF UNOMOROUND URNS BY CONTACTMc UTILITY UMOEROMUND SERNCE ALERT AT 1-900-421-1133 NOTE, EXIST, INTERCONNECT PULLBOX APPROX. 250' SOUTH OF CABINET PER CITY DRAWING NO. 2392 r ' 1 I t\\ P O I_ E S C H E D U L E LSTANDARD 0 ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT COMMENTS C Tip` hT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD 01iCLE P.- MESSAGE A B 0.-I 1 17-2-8050 20 15' 250 W B 2 N MAS SV --1–T SP -1 --CS Baseline Ave. 10 3.5 EXISTiNG 2 1--A 10 – – – B 4 E TV -1--T SP-4—CS – 1 8 4' EXISTING 3 26A-3-80 35 40' 15' 250 W B 4 E MAS, MAS, SV --1 SP -1 --CS Hemlock A -re. 0 15 EXISTING 4 1–A 10 -- – – B 6 S TV -1 SP--1--CS– 6 7 EXISTING 5A 19-3-80 30 25 13 250 W B 6 S MAS, S1i -1–T Sp -1 �CS Baseline Ave. –15' S EXISTING 5B PPB POST 3'10 – – – B 6 S – – – – – RELOCATE PPB TO r O� 5A SALVA.GE POST 6A 15 30 – 15 250 W B 8 W TV -4-T SP -4 -CS – 17 5 RELOCATE TO NEW POSITION 66 6B 15 50 – 15 250 W B 8 W TV -1–T SP–L� – 12 5 RELOCATE FROM POSI TION 6A 7 26-4-80 30 40 15 250 W B 2,8 N,W MAS,MAS,SV-2–T SP-1–CS Vi11age Pkwy, 0 1V EXISTING r EXISTING POLElO HAS A FOUNDATION FOR TYPE 19-1-80 POLE. O = 1' IRON PIPE W/BRASS DISK REMM EXISTING CONDUCTORS " - RR SPIKE W /PUNCHMARK � 0 "f M, 4 1 Z N14 - III W, 1. All work shall be done in accordance with these plans and the City of Fontana Engineering Division Trot'11'c Signal Design Guidelines, dated December 1996, and any revisions thereatter, and the Standard Specifications of the State of Colitornia Department of Transportation, latest non -ane t r i c edition. 2. Reter to the Standard Pians' of the State of California Department of Transportation, latest non-letric edition, for complete trottic signal and higMmy lighting installation detaiis. 3. The Contractor shall verify the exact location of all existing underground utilities within the improvement area prior to construction and shall be responsible for their protection and for any damage occurring to them. 4. The Contractor shall notify all concerned utility companies of least two working days in advance of excavation. 5. The exact location of new signal standards and appurtenances shall be approved in the tield by the City Engineer. 6. All pull boxes shall be I5 unless otherwise noted or approved by the City Engineer. Install all pull boxes in unprotected areas per ES -8, State Standard Plans. 7. No splicing of conductors shall be allowed. 8. All conduit shall be rigid metal and shall have a minimum 30 inches of cover in all traffic loaded areas. There shall be 36–inch sweeps on all conduit. 9. Conduit between pull box and signal standard shall be 2 inches for Type 1–A pole and 3 inches tar all most or poles. 10. The Contractor shall familiarize himself and comply with all county, state, and all local codes and regulations and OSHA requirements governing work in close proximity to high voltage power lines. Contractor shall notify the City Engineer immediately it the location of the signal standards as indicated on the plan sheets or as positioned in the field brings any part of the signal standard, signal or luminaire most arms closer than 10 teet to any power line. 11. Prior to pertorming any excavation, the Contractor shall call Underground Alert 1-800-422-4133 for underground utilities interterence checks (2 working day mini=m notice is required). 12. Autoscope detection shall be moditied as necessary by City Trattic Engineering Division. 13. Trees are to be trimmed and/or removed as directed by the City Engineer to accommodate Autoscope detection visibility. FEss E -00 Na 54931 N " Exp. •-30-00 CIVIL CIF CAL�F�� FAR0 NIL Lu]0 ----------- R/W---