HomeMy WebLinkAbout2511-1K-
A
a
A
N
W
T
(31V0) of (31VO)
3AV AMMS0 OW' 3AV Sr111110
N33FALn 01 JJM iMi Ol
a31,ox2 31Mi7A0 3N1T3M
wSee seta #23
r
C5CRT) C3A
TTPE t SARRfGADES
�� W/TTPE 'N' MARKERS
� G7 � ANDTELLOlY FLASttE�i
1
i i 1
168 ■ 168 ■ 168 M C5(LT) �11
[550'J 1550'1 [550'] _
u
F
r
U
'* DETOUR
SG3
T
& &WW in
[550']
AD A V9ff
113NO aW •3AV 9flrl10
E
n 01 dlwl nou Ol0 3f1l13AV 3N1 M"
' *See note #23
TYPE 115ARMADE'S
.
W"'T I I- L 11 MARKERS
AND YELLOW F1.A5HERS
G2
' TYPE I BARRICADES
W/TYPE 'N' MARKERS
Ror�D G2 0
oV)LJ
O
J
U
G19
X -M WrM Me with C5(LT)
YEiLOW RASIM
R17 268 M IL
168 s
MA A
168 s 16844 s
[550'] [550'] R1G
Cls Clq GS(RT) bra
D �
3
X 0 = O o
� LA
v�oo
0 > <
. aI►
i
M9EL iNE Al INK CleM
TO THRU TRAFFIC BETWEEN
CITRUS AVE. AND CHERRY AVE.
(DATE) TO (DATE) I
*Ses riots #23 F5
C5(RT)
O
E
CD
OAD
R
CLOSED
ED
E: Noo'C19
� ROAD
I MAI
*#AD
C18
SG3
BASELINE AVENUE CLOSED
TO TW TRAFFIC BETWEEN
CITNUS AVE. AND CHEMW AM .
(DATE) TO (DATE)
*see note #23
A.
MUL I NE AVOW CLOSED
TO THRU TRAFFIC BETWEEN
CITRUS AVE. AND CHERRY AVE
(DATE) TO (DATE)
Ses Hots #23
o
i
i
T
(3100) 01 (3100)
AW AilM M 011r • 3AV MK 1 a
N33A1131 O 1 AIJIM rou Ot
(IMOM 3rw3AV 30 1 iN"
*see note #23
TYPE I BARRICADES
W/TYPE If MARKERS
AND YELLOW FLA5ttERS
i
C3A CXLT)
oil
O g N
of 0 d1gi
0L go o
w
4rA —
A.WW "0
[550']
& &WW in
[550']
aWW in
[5508]
SG3
MASK ADVANCE AMD MAST ARM MOt7M= SMS
RESTRICTING LEFT TURNS ONTO CITRUS AVER
FROM BA5UM AVM OLMG DURATl01`! OF
DETOUR.
11 QUIOUR C7Z
�v
G5(RT)
GENERAL NOTES:
1. All work sholI be done In accordance with these plans and the City of Fontana
Engineering Division Standard Specifications, doted 1975, and any revisions
thereafter.
2. All materials and equipment sholl conform to the requirements of the 1994
Standard Specifications for Public Works Construction, "Greenbook" and the 1995
Supplement; the State of California, Department of Transportation (Caltrans)
Standard Plans and Standard Specifications, dated 1994; and the Caitrons Trattic
Manual, latest edition, or latest non -metric edition.
3. The contractor shall conform to all traffic control policies, methods and
'procedures described in the Caltrans Traffic Manual, Chapter 5 - Monual of
Traffic Controls for Construction and Maintenance Work Zones, latest edition, or
latest non -metric edition, and the W.A.T.C.t#. (Work Area Traffic Control
Handbook), latest edition.
4. The contractor shall refer to the City Engineer in the event of a conflict or
potential conflict with the plans and/or speciticotions for this project.
5. All required construction permits shall be obtained from the City of Fontana
Engineering Division prior to construction beginning.
6. The Contractor shall maintain access for local residents and businesses at oil
times. A minimum 3.6 meter [12 -toot] lane shall be maintoined at all times in
SG3 BASELIi1E AVENMN CLOSED the closure area for residents ond' emergency vehicles.
TO THAU TRAFFIC BETWEEN
C1TNW AVE. AND CHENW AVE.
wolm (DATE) TO (DATE) 7. Qualified t iaggers sholl be used where construction reduces the roadway to a
*See note #23 single through lane or where traffic must stop for the movement of equipment.
T -s- 8. Upon completion of construction, contractor sholl restore all signing,
striping, barricades, and other traffic control devices to their original
condition, or to the satisfaction of the City Engineer.
i
9. Exact location of all equipment and control devices to be determined by the
J+ City Engineer. Additional warning, construction signs, and/or traffic safety
equipment may be required by the City Engineer. Location of all equipment is
5G3 subject to final approval and may be modified by the City Engineer.
10. It shall be the responsibility of the contractor to maintain barricades,
delineators, or other traffic control devices at all times.
11. All work areas shall be clearly identified and delineated with cones,
portable delineators, and/or barricades. All cones or portable delineators shall
be a minimum of 71 = [28 inches] in height.
12. All signs shall be retlectorized or illuminated.
13. Traffic signdimensions, color, and lettering shall conform to the latest
Caltrons sign specification sheets.
C5(RT) BASELINE Avg eta"
TO THRU TRAFFIC
CITS AVE. AM CWMY BETWEEAV
RUE. 14. Signs shalI not be placed i n shadows or in obstructed locations.
(DATE) TO (DATE)
*Ses note $23 15. The bottom of all signs shol.l be placed a minimum of 1.8 meters [48 inches]
T i above the traveled surface and, wherever possible, 2.1 meters [7 feet] is a
preferable height.
16. Signs shall not be placed in excess of 9 meters [15 feet] from the edge of
traveled way. Portable sign standards shall be tied down or weighted to prevent
toppling.
CLT) 17. All existing signs that ore in conflict and/or are no longer applicable with
this plop, shall be covered or removed.
18. All existing striping and pavement markings that are in conflict and/or are
no longer applicable with this plan, shall be covered or removed.
19. The work zone shall be routinely inspected and maintained to ensure proper
visibility and operation of all traffic control and advance warning devices. All
flashing yellow beacons shall be inspected doily to ensure proper operation.
20. LAIl tlashing yellow warning lights shall be type "A", portable, lens
directed, enclosed and mounted at a minimum height of one meter [three feet],
measured from the bottom of the lens to the underlying surface.
�a Q G ESSI 21. All flashing yellow warning lights shall be in accordance with W.A.T.C.N.,
y� tiF latest edition.
W N 22. Contractor to notify City Traffic Section 48 hours prior to implementing this
it No. 34931 control pion to allow City staff to adjust traffic signal detection.
Elp. s-36-00
C VIS �a. 23. Advance construction signing indicating duration of project to be in place
ATF P, one week prior to imp i ement i ng detour.