HomeMy WebLinkAbout2378-1CITY OF FONTANA
GENERAL NOTES
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO
THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD
SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA.
REFER TO DEFINITIONS AND TERMS IN CITY STANDARD
SPECIFICATIONS, DATED 1975, AND ANY REVISION THEREAFTER.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM CITY OF FONTANA
PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN
THE CITY LIMITS.
3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE
OTHERWISE NOTED.
4. CURB DATA REFERS TO THE FACE OF THE CURB.
5. ALL EXPOSED CONCRETE SHALL CONFORM IN GRADE, COLOR AND FINISH
TO ALL ADJOINING CURBS AND SIDEWALKS.
6. ACTUAL THICKNESS OF A. C. PAVEMENT AND/OR BASE COUSE MATERIAL
FOR STRUCTURAL STREET SECTION SHALL BE RECOMMENDED BY A
GEOTECHNICAL ENGINEERING REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
7. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT
TO REVISION AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TEST
TAKEN AFTER COMPLETION OF ROUGH GRADING.
8. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES
FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE
SITE, THE CITY ENGINEER MAY REQUIRED TEMPORARY GUNITE SWALES,
ENTERING OR LEAVING IMPROVEMENTS
9. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF
THE STREETS.
10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES.
11. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION
STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED
WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION,
SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO NOTIFY ALL OF THE AGENCIES CONCERNED BEFORE
CONSTRUCTION BEGINS.
12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE
CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND
SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION
OF PAVING.
13. ALL VALVE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW
FINISHED GRADE BY WATER CONTRACTOR AND SHALL BE RAISED TO .
GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING.
14. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION
STANDARD DETAIL 129.
15. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL
UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO
GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE,
LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED
WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC.
16. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE
CITY OF FONTANA.
17. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS WILL BE
DETERMINED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM WITH
THE CITY OF FONTANA STANDARD DETAILS.
18. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE
SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL
IMMEDIATELY REPORT SAID CONFLICT OR POSSIBLE CONFLICT TO THE
OWNER'S REPRESENTATIVE.
19. STERILANT REQUIRED UNDER ALL A. C. PAVEMENT.
20. NO CONCRETE SHALL BE PLACED UNTIL FORMS AND REINFORCING STEEL
HAVE BEEN PLACED, INSPECTED AND APPROVED.
21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
WORKING AROUND THEIR FACILITIES.
22. ALL BACKFILL COMPACTION TO BE CERTIFIED BY SOILS ENGINEER.
23. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF
THE CITY ENGINEER.
24. BACKFILL MATERIALS SHALL BE VERIFIED BY SOILS ENGINEER AND
APPROVED BY PUBLIC WORKS INSPECTOR PRIOR TO THE PLACING
OF ANY PERMANENT PAVEMENT.
25. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS
REQUIRED BY THE CITY ENGINEER.
26. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE.
EAST
AVENUE
N �
3
Underground Service Alert
1:
A*Ii
t-
7
4
/. i t:: . :J } .rte:.: �.r. •1�l .. -..:. r .� :��, _.� .-.;... _ ,4 t- ."-:,Y:a_� 'T`3i. k �`"4
r
15
a
.-r,:..
-. .•.� -ir ,�'. .. ,..ice. :�.y IC
i
-..rte •. �. .� ::. ..: c ",'Plan
. :: , .. ... .. �;:: .. .:-# .: ... .•,. .. f
r.. i
CALTRANS GENERAL NOTES.
a) AN ENCROACHMENT PERMIT IS REQUIRED BEFORE ANY WORK MAY
BEGIN IN OR NEAR THE STATE RIGHT OF WAY.
b) ALL WORK WITHIN THE STATE RIGHT OF WAY SHALL CONFORM TO
THE LATEST STATE STANDARD PLANS & SPECIFICATIONS OR AS
DIRECTED BY THE STATE'S REPRESENTATIVE (STANDARDS OTHER
THAN STATE MUST BE PRE -APPROVED AND JUSTIFIED).
C) NO EQUIPMENT OR MATERIALS MAY BE STORED ON THE STATE RIGHT
OF WAY.
d) ALL DISTURBED AREAS IN THE STATE RIGHT OF WAY MUST BE
TREATED FOR EROSION CONTROL (HYDROSEEDING OR EQUIVALENT,
OR AS DIRECTED BY THE STATE'S REPRESENTATIVE). THE
RESPONSIBILITY FOR MAINTAINING EROSION CONTROL WILL NOT BE
RELEASED UNTIL THE SEEDING IS WELL ESTABLISHED. THE
CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF CALTRANS
CLEANING ANY DRAINAGE STRUCTURE/CHANNELS WHICH HAVE
BECOME CLUTTERED WITH DEBRIS AND/OR SILT AS A RESULT OF,
OR CAUSED BY, THE CONSTRUCTION PROJECT.
e) THE STRUCTURAL SECTION SHOWN WITHIN THE STATE RIGHT OF WAY
IS FOR ESTIMATING PURPOSES ONLY. THE ACTUAL SECTION WILL
BE DESIGNED BY A SOIL ENGINEER AFTER NATIVE SOIL TESTING
HAS BEEN COMPLETED. A TRAFFIC INDEX (TI) OF 11 SHALL BE
USED IN THE DESIGN OF THE TRAVELLED WAY, AND A TI OF 7
SHALL BE USED FOR THE SHOULDER DESIGN. THE LABORATORY
REPORTS AND THE DESIGN CALCULATIONS SHALL BE SUBMITTED TO
THE STATE'S REPRESENTATIVE FOR APPROVAL PRIOR TO
CONSTRUCTION OF THE STRUCTURAL SECTION.
f) ALL STATE DRAINAGE STRUCTURES MUST FIRST BE COMPLETELY
CLEANED OF DEBRIS AND/OR SILT BY THE CONTRACTOR PRIOR TO
MAKING THE CONNECTION.
9) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ANY
STATE DRAINAGE FACILITY WHICH IS CONNECTED TO OR DIRECTLY
AFFECTED BY THE CONTRACTORS OPERATION SHALL BE CLEAN AND
OPERATIONAL PRIOR TO FINAL ACCEPTANCE OF THE PERMIT WORK
BY THE STATE. ADEQUATE CLEAN -OUTS AND ACCESS OPENINGS
SHALL BE PROVIDED IN ANY CONTRUCTION WITHIN THE STATE'S
RIGHT OF WAY FOR FUTURE MAINTENANCE AND REPAIR WORK AS
NEEDED. THIS WORK SHALL BE FURNISHED AT NO COST TO THE STATE.
16 17
FOOTHILL
ULBERRY
AVENUE
i F -I- T .... .........
COTTONWOOD
AVENUE �
4) (5) (6
h) WHERE SURVEY MONUMENTS EXIST, SUCH MONUMENTS SHALL BE
PROTECTED OR SHALL BE REFERENCED AND RESET PURSUANT TO
BUSINESS AND PROFESSIONS CODE, SECTIONS 8700 TO 8500 (LAND
SURVEYOR'S ACT).
i) THE PAVEMENT MUST BE SAW -CUT 2' MINIMUM FROM THE EDGE OF
PAVEMENT. THE SAW -CUTS MUST BE PERPENDICULAR OR PARALLEL
TO THE STATE HIGHWAY CENTERLINE.
j) ALL SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL BE IN
CONFORMANCE WITH THE CURRENT EDITION OF THE TRAFFIC
MANUAL, PUBLISHED BY THE STATE OF CALIFORNIA, DEPARTMENT
OF TRANSPORTATION, AND THE SPECIAL PROVISIONS. ALL
PAVEMENT MARKINGS SHALL BE THERMOPLASTIC UNLESS OTHERWISE
NOTED.
k) THE EXACT LOCATION OF ALL SIGNS SHALL BE DETERMINED IN THE
FIELD BY THE STATE'S REPRESENTATIVE.
1) ALL CONFLICTING STRIPING AND PAVEMENT MARKINGS NOT SHOWN
ON THE PLANS SHALL BE REMOVED FROM THE PAVEMENT BY
SANDBLASTING BY THE CONTRACTOR.
m) ALL CONFLICTING SIGNS SHALL BE EITHER REMOVED OR RELOCATED
BY THE CONTRACTOR. RELOCATABLE SIGNS SHALL BE INSTALLED
AS SPECIFIED ON THE PLANS OR AS DETERMINED IN THE FIELD BY
THE STATE'S REPRESENTATIVE.
n) ALL SIGNS, ROADSIDE MARKERS, ELECTROLIERS, ETC., SHALL BE
PROTECTED AND/OR REPLACED IN KIND ACCORDING TO THE CURRENT
STATE STANDARD PLANS AND THE CURRENT TRAFFIC MANUAL, AT NO
COST TO THE STATE.
o) WORK SHALL NOT COMMENCE UNTIL THE STORM DRAIN, SEWER AND
WATER PROJECTS HAVE BEEN COMPLETED.
LEGEND
O STREET PLAN &PROFILE
181 1
STRIPING PLANS 19
/BANNUE
�� � - mgr
CAVEf�fUEH
BENCHMARK:
CHISELED "X" N.E. CORNER OF
ABUTMENT AT FOOTHILL BLVD.
AND EAST AVE.
#67-5 ELEV. 1195.52
REVISIONS
71- 7TT-1
\ AL ND
AVENUE
UINDEX MAP
1 ° =500
E
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE
ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE
AGENCY OR THE ENGINEER.
UNDERGROUND UTILITIES & STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO
PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION
OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
"CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE
RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF
THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND
MUST BE APPROVED BY THE PREPARER OF THESE PLANS.,,
ENGR'S.CITY
000nX/AI DATE I AnnonX
10
20
CHERRY
AVENUE
EDWOOD BOULEVARD
WEN U E /
�-I I IL 11.,E_1J--IJ u_1hA
11
12
M M M r�_ I & man, Inc.
NMF�" d Civil Engineering • Planning - Surveying - Public Works
13821 Newport Ave,, Suite 200 - Tustin, CA 92680-7803 - 714/544-3404
PREPARED UNDER THE SUPERVISION OF:
DATE I JOHN C. HOGAN
R.C.E. 26229
DATE:
13
SHEET INDEX
SHEET No. DESCRIPTION
1 TITLE SHEET
2 TYPICAL SECTIONS &DETAILS
3-15 STREET PLAN &PROFILE
16-21 STRIPING PLANS
22- STREET CROSS SECTIONS
m GPS.
HIGHLAND AVF.
a a CITY a
v 15 OF
a w a FONTAN w
o S. PACIFIC w w
ARIL OAD °0
ASE LI E A BASE LINE AVE.
MI LER AVE. <
ZI Y
FUTURE OF OF w
REGIONAL ANCHO = PROJECT
PARK CU AMO FOOTHILL BLVD. Z _T I I 'I I I"o I Iv
COUNTY OF SAN BERNARDINO
ARROW HIGHWAY
VICINITY MAP
21
LAV N�UEK /
14
N.T.S.
HEMLOCK
AVENUE
IL.777�������� - -
15
CITY OF FONTANA, CALIFORNIA
Ln
DRAWN BY
SCALE:
40
R.A.
STREET IMPROVEMENTS
HORIZ.: 1"=40
VERT.: 1"=4'
�a
��
DESIGNED BY
FOOTHILL BOULEVARD - ROUTE 66
�i
DATE:
CHECKED BY
JOB N0.
3828
APPROVED DR. N0. SHT. N0.
Z 37
M
�
CITY ENGINEER #25126 DATE 1 OF 35
�,:;
a
g►