Loading...
HomeMy WebLinkAbout2378-1CITY OF FONTANA GENERAL NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS, DATED 1975, AND ANY REVISION THEREAFTER. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM CITY OF FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. CURB DATA REFERS TO THE FACE OF THE CURB. 5. ALL EXPOSED CONCRETE SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 6. ACTUAL THICKNESS OF A. C. PAVEMENT AND/OR BASE COUSE MATERIAL FOR STRUCTURAL STREET SECTION SHALL BE RECOMMENDED BY A GEOTECHNICAL ENGINEERING REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 7. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH GRADING. 8. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRED TEMPORARY GUNITE SWALES, ENTERING OR LEAVING IMPROVEMENTS 9. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF THE STREETS. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. 11. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL OF THE AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS. 12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 13. ALL VALVE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY WATER CONTRACTOR AND SHALL BE RAISED TO . GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 14. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 15. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 16. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 17. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM WITH THE CITY OF FONTANA STANDARD DETAILS. 18. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATELY REPORT SAID CONFLICT OR POSSIBLE CONFLICT TO THE OWNER'S REPRESENTATIVE. 19. STERILANT REQUIRED UNDER ALL A. C. PAVEMENT. 20. NO CONCRETE SHALL BE PLACED UNTIL FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO WORKING AROUND THEIR FACILITIES. 22. ALL BACKFILL COMPACTION TO BE CERTIFIED BY SOILS ENGINEER. 23. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 24. BACKFILL MATERIALS SHALL BE VERIFIED BY SOILS ENGINEER AND APPROVED BY PUBLIC WORKS INSPECTOR PRIOR TO THE PLACING OF ANY PERMANENT PAVEMENT. 25. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED BY THE CITY ENGINEER. 26. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE. EAST AVENUE N � 3 Underground Service Alert 1: A*Ii t- 7 4 /. i t:: . :J } .rte:.: �.r. •1�l .. -..:. r .� :��, _.� .-.;... _ ,4 t- ."-:,Y:a_� 'T`3i. k �`"4 r 15 a .-r,:.. -. .•.� -ir ,�'. .. ,..ice. :�.y IC i -..rte •. �. .� ::. ..: c ",'Plan . :: , .. ... .. �;:: .. .:-# .: ... .•,. .. f r.. i CALTRANS GENERAL NOTES. a) AN ENCROACHMENT PERMIT IS REQUIRED BEFORE ANY WORK MAY BEGIN IN OR NEAR THE STATE RIGHT OF WAY. b) ALL WORK WITHIN THE STATE RIGHT OF WAY SHALL CONFORM TO THE LATEST STATE STANDARD PLANS & SPECIFICATIONS OR AS DIRECTED BY THE STATE'S REPRESENTATIVE (STANDARDS OTHER THAN STATE MUST BE PRE -APPROVED AND JUSTIFIED). C) NO EQUIPMENT OR MATERIALS MAY BE STORED ON THE STATE RIGHT OF WAY. d) ALL DISTURBED AREAS IN THE STATE RIGHT OF WAY MUST BE TREATED FOR EROSION CONTROL (HYDROSEEDING OR EQUIVALENT, OR AS DIRECTED BY THE STATE'S REPRESENTATIVE). THE RESPONSIBILITY FOR MAINTAINING EROSION CONTROL WILL NOT BE RELEASED UNTIL THE SEEDING IS WELL ESTABLISHED. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF CALTRANS CLEANING ANY DRAINAGE STRUCTURE/CHANNELS WHICH HAVE BECOME CLUTTERED WITH DEBRIS AND/OR SILT AS A RESULT OF, OR CAUSED BY, THE CONSTRUCTION PROJECT. e) THE STRUCTURAL SECTION SHOWN WITHIN THE STATE RIGHT OF WAY IS FOR ESTIMATING PURPOSES ONLY. THE ACTUAL SECTION WILL BE DESIGNED BY A SOIL ENGINEER AFTER NATIVE SOIL TESTING HAS BEEN COMPLETED. A TRAFFIC INDEX (TI) OF 11 SHALL BE USED IN THE DESIGN OF THE TRAVELLED WAY, AND A TI OF 7 SHALL BE USED FOR THE SHOULDER DESIGN. THE LABORATORY REPORTS AND THE DESIGN CALCULATIONS SHALL BE SUBMITTED TO THE STATE'S REPRESENTATIVE FOR APPROVAL PRIOR TO CONSTRUCTION OF THE STRUCTURAL SECTION. f) ALL STATE DRAINAGE STRUCTURES MUST FIRST BE COMPLETELY CLEANED OF DEBRIS AND/OR SILT BY THE CONTRACTOR PRIOR TO MAKING THE CONNECTION. 9) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ANY STATE DRAINAGE FACILITY WHICH IS CONNECTED TO OR DIRECTLY AFFECTED BY THE CONTRACTORS OPERATION SHALL BE CLEAN AND OPERATIONAL PRIOR TO FINAL ACCEPTANCE OF THE PERMIT WORK BY THE STATE. ADEQUATE CLEAN -OUTS AND ACCESS OPENINGS SHALL BE PROVIDED IN ANY CONTRUCTION WITHIN THE STATE'S RIGHT OF WAY FOR FUTURE MAINTENANCE AND REPAIR WORK AS NEEDED. THIS WORK SHALL BE FURNISHED AT NO COST TO THE STATE. 16 17 FOOTHILL ULBERRY AVENUE i F -I- T .... ......... COTTONWOOD AVENUE � 4) (5) (6 h) WHERE SURVEY MONUMENTS EXIST, SUCH MONUMENTS SHALL BE PROTECTED OR SHALL BE REFERENCED AND RESET PURSUANT TO BUSINESS AND PROFESSIONS CODE, SECTIONS 8700 TO 8500 (LAND SURVEYOR'S ACT). i) THE PAVEMENT MUST BE SAW -CUT 2' MINIMUM FROM THE EDGE OF PAVEMENT. THE SAW -CUTS MUST BE PERPENDICULAR OR PARALLEL TO THE STATE HIGHWAY CENTERLINE. j) ALL SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL BE IN CONFORMANCE WITH THE CURRENT EDITION OF THE TRAFFIC MANUAL, PUBLISHED BY THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, AND THE SPECIAL PROVISIONS. ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC UNLESS OTHERWISE NOTED. k) THE EXACT LOCATION OF ALL SIGNS SHALL BE DETERMINED IN THE FIELD BY THE STATE'S REPRESENTATIVE. 1) ALL CONFLICTING STRIPING AND PAVEMENT MARKINGS NOT SHOWN ON THE PLANS SHALL BE REMOVED FROM THE PAVEMENT BY SANDBLASTING BY THE CONTRACTOR. m) ALL CONFLICTING SIGNS SHALL BE EITHER REMOVED OR RELOCATED BY THE CONTRACTOR. RELOCATABLE SIGNS SHALL BE INSTALLED AS SPECIFIED ON THE PLANS OR AS DETERMINED IN THE FIELD BY THE STATE'S REPRESENTATIVE. n) ALL SIGNS, ROADSIDE MARKERS, ELECTROLIERS, ETC., SHALL BE PROTECTED AND/OR REPLACED IN KIND ACCORDING TO THE CURRENT STATE STANDARD PLANS AND THE CURRENT TRAFFIC MANUAL, AT NO COST TO THE STATE. o) WORK SHALL NOT COMMENCE UNTIL THE STORM DRAIN, SEWER AND WATER PROJECTS HAVE BEEN COMPLETED. LEGEND O STREET PLAN &PROFILE 181 1 STRIPING PLANS 19 /BANNUE �� � - mgr CAVEf�fUEH BENCHMARK: CHISELED "X" N.E. CORNER OF ABUTMENT AT FOOTHILL BLVD. AND EAST AVE. #67-5 ELEV. 1195.52 REVISIONS 71- 7TT-1 \ AL ND AVENUE UINDEX MAP 1 ° =500 E PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE AGENCY OR THE ENGINEER. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.,, ENGR'S.CITY 000nX/AI DATE I AnnonX 10 20 CHERRY AVENUE EDWOOD BOULEVARD WEN U E / �-I I IL 11.,E_1J--IJ u_1hA 11 12 M M M r�_ I & man, Inc. NMF�" d Civil Engineering • Planning - Surveying - Public Works 13821 Newport Ave,, Suite 200 - Tustin, CA 92680-7803 - 714/544-3404 PREPARED UNDER THE SUPERVISION OF: DATE I JOHN C. HOGAN R.C.E. 26229 DATE: 13 SHEET INDEX SHEET No. DESCRIPTION 1 TITLE SHEET 2 TYPICAL SECTIONS &DETAILS 3-15 STREET PLAN &PROFILE 16-21 STRIPING PLANS 22- STREET CROSS SECTIONS m GPS. HIGHLAND AVF. a a CITY a v 15 OF a w a FONTAN w o S. PACIFIC w w ARIL OAD °0 ASE LI E A BASE LINE AVE. MI LER AVE. < ZI Y FUTURE OF OF w REGIONAL ANCHO = PROJECT PARK CU AMO FOOTHILL BLVD. Z _T I I 'I I I"o I Iv COUNTY OF SAN BERNARDINO ARROW HIGHWAY VICINITY MAP 21 LAV N�UEK / 14 N.T.S. HEMLOCK AVENUE IL.777�������� - - 15 CITY OF FONTANA, CALIFORNIA Ln DRAWN BY SCALE: 40 R.A. STREET IMPROVEMENTS HORIZ.: 1"=40 VERT.: 1"=4' �a �� DESIGNED BY FOOTHILL BOULEVARD - ROUTE 66 �i DATE: CHECKED BY JOB N0. 3828 APPROVED DR. N0. SHT. N0. Z 37 M � CITY ENGINEER #25126 DATE 1 OF 35 �,:; a g►