Loading...
HomeMy WebLinkAbout2369-1GENERAL NOTES 1. All work shall be done in accordance- with these plans and Standard Specifications for Public Works Construction (Green Book), latest edition. 2. Construction permits shall be obtained from the City of Fontana Engineering Division prior to start of any work within city limits. 3. Stationing refers to centerlines of street except where otherwise noted. 4. Curve data refers to the face of the curb. 5. All exposed concrete shall conform in grade, color and finish to all ad joinig curbs and sidewalks. 6. Actual thickness of A.C. pavement and/or base course material for street structural section shall be recommended by a geotechnical engineering report and submitted to the City of Fontana for approval upon completion of rough grading. The project developer is, in general, required to bring his half street section frontages up to a 20 year design life between site property lines, plus reasonable joins to existing pavement subject to approval by the City Engineer. 7. Pavement structural sections shown are minimum and subject to revision and approval of the City as required by soils teste taken by the developers Geotechnical Engineer after completion of rough grading. Should the street construction start more than three months after the plans are approved, and if field pavement conditions change; then the developer would be required to update the design to accomodate actual field conditions. 6. Care should be taken to prevent grades, ditches and swales from undermining street improvements. Upon inspection of the site, the City Engineer may require temporary gunite swales, entering or leaving improvements. 9. All underground work shall be completed prior to paving of the streets. 10. Adequate stakes shall be set by the Engineer to enable the contractor to construct the work to the plan grades. 11. All pipes or substructures of any kind and all telephone or power poles, water meters, valves, hydrants, irrigation structures, etc., shown or not shown on this plan and located within areas to be improved and interfering with construction shall be relocated by others. It shall be the contractor's responsibilty to notify all of the agencies concerned before construction begins. 12. All manhole and cleanout frames and covers shall be constructed 6" below finished grade by sewer contractor and shall be raised to grade by paving contractor after completion of paving. 13. All valve cans and covers shall be constructed 6" below finish grade by water contractor and shall be raised to grade by paving contractor after completion of paving, 14. Refer to City of Fontana, underground utility location Standard Detail No. 129. 15. The contractor(s) shall coordinate construction with all utilities and other Improvements including, but not limited to, gas, tele- phone, electrical, lighting, television cable, landscaping, landscaping irrigation, domestic water, reclaimed water, sewer, storm drainage, flood control systems, etc. 16. Recorded drawings shall br provided by the engineer to the City of Fontana. 17. Type, location and width of driveway approach aprons will be determined at the time of construction and shall conform with City of Fontana standard details. 18. Contractor is instructed to refer to these plans and the specifications, and where there is or may be a conflict shall immediately report said conflict or possible conflict to the owner's representative. 19. Soil sterilant required under all A.C. pavement. 20. No concrete shall be placed until forms and reinforcing steel have been placed, Inspected and approved. 21. All ultility companies shall be given 48 hours notice prior to work around thher facilities. 22. All backfill compaction to be certified by soils engineer. 23. All materials and methods to be subject to the approval of the City Engineer. 24. Backfill materials shall be verified by contractor and approved by Public Works Inspector prior to the placing of any permanent pavement. 25. Contractor to install pavement markings and striping as required by the Traffic City Engineer. 26. Contractor shall not operate any main line water valve. 27. If existing utilities or any other facilities conflict with the proposed improvements, work shall stop and the Engineer notified immediately. 28. It shall be the responsibility of the contractor to notify the Engineer after the base course of pavement has been constructed and before the final paving cap has been installed so that the Engineer may install the street centerline monuments as required by the City Code of the City of Fontana. R1Vc'J?S17F: 31_0EPPIN7 - C21Vr,G251(> :, C;ALJF 246 HORZ. SCALE I"= 401 VERT SCALE I"= 4` Z F1 ESTIMATED QUANTITY ORemove existing 8 curb - 122 m cone. gutter- 194' rn sidewalk - 1070 sf O driveway approach -- 2 ea. N CyJ Relocate street signs •-- 4 ea. ; water meter - l ea. private sign - I ea. Const. 8" curb 8c gutter per City Std. 101 164 LF J Const. tree wells 3'x 3' at 247460, 248422, 248485 Plant tree ( purple Legerstroemio, crape myrtle) in well with two bubblers ea., handicap approved walk grates 3 EA 4� Const. 6" A.C. over exist. A.B. 59 TN 1578 SF �1 Const. 2 driveway appr. per City Std. 102C w= 30 w=42 2 EA 6� Const. 12' wide, 4" thick, cont. sidewalk per City Sid. 105A 1805 SF Const. 169'x 14' medien island, 366- 8" curb & landscaping I EA U N 1. 00 * M � N � 0 0 �n N N 1.04% Exist. F. L. 0 .rn MM Propos •d Top of raisededlen Island N u Exist. rt Grade � V � O \N 46 O H w V v 3 A �O nSA NNN �~ 1• N� N•N A? % ..- o- 7 '/o 247 248 I EXIST. R/ W -\ I 249 EX IST, 8 C /G N C1� to O N M ICN 16 0 h^ o 3 co 00 � � k H0.7 N H 3 2 I 3 N ° N 4N 3 2 _ 10 R S: f 0ti' 1Ito 30-CJ ,E C ' u 169.15 6 0 _ wM - � 03 z 25 f- n M Proposed R/W + N J , co Wco N� t 19 w � 8983 SIERRA AVE. w M EXISTING 1 4 BUILDING I APN 194 - Oil- 20 0 N UNDERGROUND BENCH MARK SERVICE CITY OF FONTANA ALERT call BM No. 436 1-800-422-4133 Top of fire hydrant at N. curb of Martin Ave. 8� Sierra Ave. DESIG REVIEW NO.95-04 TWO WORKING DAYS Elev. 1221.40' REF. DING. NO. 582 BEFORE DIGGING 0� 6/30/99 r W J J z- J W 0 0 W oc z E -- o < SIERRA a11 AVE. a z %'' clU SITE � U a a � VICINITY MAP NO SCALE _ S/E'RRA _ No007' 15"E a EXIST. 8 C/G " W - 1 P� EXIST. RAY g7' ..- z I I 39` - 34' 44 3 3 arc I O. o�c 12' 48' 48 12' 16' 12' 13- L 14' 13' 12 16' FUTURE SIERRA AVE. MERRI LL AVE. TO MARYGOLD AVE. NOT FOR IMMEDIATE CONSTRUCTION CITY OF FONTANA, LIFORN 1A PUBLIC WORKS DEPARTMENT WALTER W. HU DRAWN SCALESTREET IMPROVEMENT PLAN 11655 Countryside Dr., Fontana, CA 92337 YMP I" = 40' Phone /Fax (909)-685-5762 DESIGNED 8983 SIERRA AVENUE DATE HU (D.R. #95-04) SUNDOWNER RESTAURANT Vla QV2S f 99 CHECKED APPROVE DWG. N0. REVISIONS DATE ENGR. DATE CITY WALTER W. HU, RCE 29954 EXP. 6/30/99 DATE fit CITY ENGR. ROBERT W WEDOLE, RCE25126, EXP. 12/31/ L m rn O N CyJ 3 3 arc I O. o�c 12' 48' 48 12' 16' 12' 13- L 14' 13' 12 16' FUTURE SIERRA AVE. MERRI LL AVE. TO MARYGOLD AVE. NOT FOR IMMEDIATE CONSTRUCTION CITY OF FONTANA, LIFORN 1A PUBLIC WORKS DEPARTMENT WALTER W. HU DRAWN SCALESTREET IMPROVEMENT PLAN 11655 Countryside Dr., Fontana, CA 92337 YMP I" = 40' Phone /Fax (909)-685-5762 DESIGNED 8983 SIERRA AVENUE DATE HU (D.R. #95-04) SUNDOWNER RESTAURANT Vla QV2S f 99 CHECKED APPROVE DWG. N0. REVISIONS DATE ENGR. DATE CITY WALTER W. HU, RCE 29954 EXP. 6/30/99 DATE fit CITY ENGR. ROBERT W WEDOLE, RCE25126, EXP. 12/31/ L