Loading...
HomeMy WebLinkAbout2367-M-1Af\ Fz� on 6 C7 Z Z D ccM —RECORD DRAWING THESE RECORD DRAWINGS (AS -BUILT DRAWINGS) HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, WOLFF/LANG/CHRISTOPHER ARCHITECTS, INC., HAS NOT VERIFIED THIS INFORMATION AND IS NOT RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, NOR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT. Certificate Of Compliance(Part 1 of 2) Performance Requirements CF -1B FONTANA FIRE #77 2\91 For Enforcement Agency Use only Project Title Date OT Leif t care WOLFF LANG1CHRISTOPHER ARCHITECTS MojectArChltec ngineer Buitding Permit Number Project Location Plans ChecKed By a e FONTANA CA. I y own Field Checkedy D a e JEFF DISCOUNT/J.H.E. (714)544-0636 ocumen a ton u or irm Yetepnone Approved By Date Principal Designer. The proposed building wit t be in sub- stantial compliance with the California Building Energy Efficiency Standards provided it is built according to the plans and specifications and provided future improvements are completed according to the requirements indicated on this Certificate of Compliance. The plans end specifications have been prepared to include all significant energy conservation features required for compliance with the Standards. Building areas that are unconditioned and/or not subject to the standards are indicated on the plans. 2\91 2\91 ans dated specs dated Signature Date LARRY WOLFF/A.I.A. Name It e WOLFF/LANG/CHRISTOPHER ARCHITECTS ortpany 10470 FOOTHILL BLVD. ress RANCHO CUCAMONGA CA.91730 City/State/Lip (714)987-0909 C19064 TeLephone Cal. License NO. Owner. The energy conservation features and performance specifications indicated on this document and on the plans and specifications shall apply to future alterations, unless compliance is demonstrated anew and a new Certificate of Compliance is submitted. A copy of this Certificate will be retained and transmitted to future tenants, subsequent owners or others with responsibility for making improvements or modifications to the building. If this certificate is lost, a new Certificate may be required before a permit is issued for alterations. Unconditioned areas are indicated on the plans and, if these areas are conditioned in the future, they must be made to comply with the applicable energy standards then in effect. signature Date Name/Titte CITY OF FONTANA ompany 8353 STERRA AVE. Address FONTANA,CA.92335 city/state/tip Enforcement Agency. The proposed building, and future alterations will comply with the California Building Energy Standards, provided future alterations meet the requirements indicated on this Certificate and all applicable mandatory measures, as long as the building occupancy type remains unchanged. Signature Date Name/Titte Company Address City/State/Zip , Energy Analyst The energy performance analysis summarized below was performed using an approved CEC calculation method with CECapproved fixed and restricted engineering inputs for the applicable clima one and occ y type, and using an appropriate repr at on of buitdi zoning and physical conf' r tion. 'Al i ,cant ener y conservation features a lis ow, n attached / lement. sign ure v uaLe JO HAMMOND/P.E. Nfme/T It le JON HAMMOND ENGINEERS Proposed Company 1 2472 CHAMBERS RD. 30.38 h-F-sf/Btu ress Average Exterior Floor Rt. TUSTIN CA.92680 h-F-sf/Btu t y a e ip 0.72 (7 14) 544-0636 4 letephone 315 General Reference 5 1 Unconditioned or Multi -tenant shell?... NO 2 CEC Occupancy Type.......... LOW RISE OFFICE 3 UBC Occ. Group/Division..... 6-Z Average SC (Roof)........ 4 Climate Zone................10 5 Conditioned Floor Area ...... WS -1A 4150 sf 6 Unconditioned Floor Area.... sf 7 Budget Table(fr. Standards).2-53R 8 All. Energy Budget(WS-1A)... WS -1A 189.01 kBtu/sf-yr 9 Calc.Method CEC Code/Date ...SCM 2.OH 10 Multiplier ..................INCL. 11 Calculated Energy Use....... 176.9 kBtu/sf-yr Envelope Requirements 12 Average Roof/Ceiling Rt ..... CF -2 30.38 h-F-sf/Btu 13 Average Exterior Floor Rt... h-F-sf/Btu 14 Average Opaque Wall Rt ...... CF -2 0.72 h-F-sf/Btu 15 Glazing Area in Watt ........ CF -2 315 of 16 Average SC (wall glazing) ... CF -2 0.75 17 Glazing Area in Roof........ sf 18 Average SC(Roof glazing).... Ughling Requirements 19 Allowed Whole Building LPD.. watts/sf 20 Allowed Common Areas LPD.... watts/sf 21 Allowed Tenant Space LPD.... watts/sf 22 Package Lighting Reduction.. watts/sf 23 Lighting Controls Required?. (Y/N) Mechanical Requirements 24 System Type ............... 25 Unit Fan Power ............. watts/cfm 26 Rated Cooling Efficiency.... 8.5 EER (units) 27 Rated Cooling Capacity...... WS -4A 136.7 kBtu hr (units) 28 Rated Heating Efficiency .... 79 % (units) 29 Rated Heating Capacity...... WS -4A 239.2 kBtu hr (units) 30 Economizer Cooling?........ Y (Y/N) 31 CF -1X Attached? .................... (Y/N) EEM Form Revised September 1988 Page of Certificate of Compliance (Part 2 of 2) Performance Compliance CF -1B FONTANA FIRE #77 2\91 4150 For Enforcement Agency Use Only Fr6ject TI vale BY er t ica a r. rea JEFF DISCOUNT/J.H.E. (714)544-0636 OFFICE Documentation u or irm T a I ep,one ETC occ. Type Ptan Checked By Date Nota. More than one Part 2 may be submitted but all must reference the same Part 1. The person responsible for design compliance for each major building system acknowledges the following compliance statement by signing the appropriate space below. Compliance Statement The proposed building improvements substantially comply with the requirements indicated on the Certificate of Compliance for this building, dated Theplans and specifications include the significant energy conservation features and the compliance documentation is consisTtent with the plans and specifications. Envelope Allowed Proposed 2 91 1 Average Roof/Ceiling Rt... 30.38 h-F-sf/Btu 2 Average Exterior Floor Rt. q0 --2-;;517-o0 h-F-sf/Btu 3 Average Opaque Wall Rt.... 0.72 h-F-sf/Btu 4 Glazing Area in Wall...... 315 of 5 Average SC (Wall)........ 0.75 My/state/Zip 6 Glazing Area in Roof...... 9340 sf T Average SC (Roof)........ Date Other requirements: Lighting 8 Basis of Al lowed LPD...... TSI LO f? -F- t] Allowed Proposed 9 LPD ...................... 12 watts/sf 10 Package Lighting Reduction — watts/sf 11 Adjusted LPD .............. I.2 2 watts/sf 12 Lighting Control Credits...........t J (Y/N) Other requirements: • %—jaIU' r. IVA 01a stgn,axurev v- nate JON HAMMOND/P.E. 46me/Titte ON HAMMOND ENGINEERS w- any 2472 CHAMBERS RD. Address TUSTIN CA.92680 t y a e ip (714)544-0636 11712 Tee one Cal. License No. Entorcemerit Date NEW CONSTRUCTION txtent oT improvements •1? 2 91 2 N 91 P ans aatea Specs cated Signature Date HARRY MACDONALD/ENGINEER q0 --2-;;517-o0 Aaoe i e M/P ENGINEERS INC. Company 3828 W. COMMONWEALTH AVE. Address FULLERTON CA.92633 My/state/Zip (714) 6803044 9340 eLepnone Cat. License No. n orcemen Date Mechanical Allowed Proposed NEW CONS ION 13 Unit Fan Power............ watts/cfm x 9 o ro en s /17 9 1 ans a pets clat 14 Rated Coding Efficiency.. 8.5 EER (units) aur a.! 15 Rated Cooling Capacity.... 136.7 kBtu hr (units) i9y HAMMOND P.E. a 56 t e 16 Rated Heating Efficiency.. (units)JON HAMMOND ENGINEERS 17 Rated Heating Capacity... _ 239.2 kBtu hr (units>r47n 2472 CHAMBERS RD. 18 Economizer Cooli•,g?....... _ Y (Y/N) A.ss > 19 Simultaneous heat/cool?... (Y/N) TUSTIN CA.92680 J Other requirements: C -7S-BT-e� t� --� - '� 1 (714)544-0636. 11712 Te"�c�6nc.- a ,cense No. Date EEM Form Revised September 1988 Page of CITY OF FONTANA FIRE STATION NO. w+wwuu�� r� V • FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT CONSULTANT JON HAMMOND ENGINEERS Enginoerin8 Consultant 2472 Chambers Road, Suite 130 Tustin, CA 82680 (714) 544-0636 APPROVED [,COMPLIANCE SHEET DRAWN •1? CHECKED ' •N. DATE 3✓11 SCALE 000 s J06 No. q0 --2-;;517-o0 M—lAl [)wc, Wb. 23a'l