HomeMy WebLinkAbout2367-M-1EOUIVr%IVIVEIN'T LIST CARRIER Model: 48 DJD 005 EER = 8.5 1 Cooling Cap. - 45,200 BTU/Hr. Total, 30,000 BTU/Hr. Sensible @ Ent. Evap. Cond. of 750F DB, 650F WB & 110°F Amb. Air Temp. Heating Cap. - 74,000 BTU/Hr. input, 58,500 BTU/Hr. output Fan Cap. - 1600 CFM @ 0.7" E.S.P. Electrical - 3/4 HP, 22 FLA, 208/230 volt, 3 phase, 60 cycle Operating Wt. - 600 lbs. Provide with Aconomizer cycle. CSA 1-5 OF MI CARRIER Model: 48 DJE 007 Cooling Cap. - 67,500 BTU/Hr. Total, 53,000 BTU/Hr. Sensible 2 @ Ent. Evap. Cond. of 760F DB, 660F WB & 110°F Amb. Air Temp. Heating Cap. - 115,000 BTU/Hr. input, 91,000 BTU/Hr. output Fan Cap. - 2600 CFM @ 0.7" E.S.P. Electrical - 1 1/2 HP, 32 FLA, 208/230 volt, 3 phase, 60 cycle Operating Wt. - 700 lbs. Provide with conomizer cycle. 015A-_ 615iolf� ti I KI . f✓ Central Restroom Exhaust I LOREN COOK Model - 135 C3B Capacity - 1000 CFM @ 3/4" S.P. Electrical - 1/4 HP, 120 volt, 1 phase, 60 cycle Operating Wt. - 100 lbs. Interlock with light switch. Apparatus Room Exhaust 2 LOREN COOK Model - 180 C8B Capacity - 4600 CFM @ 3/4" S.P. Electrical - 1 1/2 HP, 208 volt, 3 phase, 60 cycle Operating Wt. - 150 lbs. Interlock with light switch. (Reference Detail 1, Sheet E5.) Apparatus Room Heater REZNOR Model CXE-75 Z �04. Capacity - 75,000 BTU/Hr. input, 60,000 BTU/Hr. output. Fan - 1/3 HP, 120 volt, 1 phase, 60 cycle ,Operating Wt. - 400 lbs. k�r1v�►a Ef b•Jc��.1'tpv..�'rt'ro, L.. f�L� G1a � R Cwt'! L.pt.worr� S Lti.J �..t3'F �,,�'�,'i'ti s AT Wv..04 HgA79Y . . V V T SCHEDULE SYMBO' MFGR. & INLET ®C. B YKBOL MODEL NO. B ISS A AIRFLOW RETURN AIR REGISTER CARRIER E.A.R. EXHAUST AIR REGISTER ®S. 35 PSA -06 10 x 9 290 cfm '"'V u T - 2 CARRIER ®E. A. EXHAUST AIR DUCT 35 PSA -06 10 x 9 170 cfm VVT`.� CARRIER 4 -WAY THROW PATTERN (� O.L. 35 PSA -06 10 x 9 170 cfm VV T_ 4 CARRIER A.V.O. AUTOMATIC VOLUME DAMPER • 35 PSA -06 10 x 9 170 cfm L.D. CARRIER ROOM THERMOSTAT 35 PSA -06 10 x 9 220 cfm CARRIER 35 PSA -06 10 x 9 170 cfm VVT- 7 CARRIER 35 PSA -06 10 x 9 430 cfm ,V u T_ 8 CARRIER 35 PSA -08 16 x 10 600 cfm ,%/v T._ 9 CARRIER 35 PSA -10 16 x 10 1050 cfm CARRIER 35 PSA -06 10 x 9 365 cfm CARRIER 35 PSA -08 16 x 10 515 cfm VV T I z CARRIER oo ROoIo 35 PSA -10 16 x 10 1280 cfm , CARRIER o r4 Rroo r 35 PSA -10 16 x 10 2080 cfm IJOYa MIPIMLIN A4f?-- FLOH of:$ VVT I-VVT II o5 elL. 5a 5o/a OP - D E-� I el 0 0&1 F, FL.d 0. DRESCO REPRODUC71014 INC. 141679 1 MECHANICAL L SYMBO' At BRE!'.'DESCRIPTION ®C. D. CEILIIJG DIFFUSER KRUEGER MODEL 1600 TYPE 4 FASTENING W/OBD R.A.R. RETURN AIR REGISTER ® E.A.R. EXHAUST AIR REGISTER ®S. A. SUPPLY AIR DUCT KRUEGER MODEL EGC-5 W/OBD MP► -.do. Brio R. A. RETURN AIR DUCT ®E. A. EXHAUST AIR DUCT C.F.M. CUBIC FEET/MINUTE OF AIR '4 W 4 -WAY THROW PATTERN (� O.L. DOOR LOUVER M.V.D. MANUAL VOLUME DAMPER T A.V.O. AUTOMATIC VOLUME DAMPER • A.F.D. AUTOMATIC FIRE DAMPER - - L.D. LINED DUCT ROOM THERMOSTAT 5M6 Ir -e D EYI!M T"YPIo-LLY 6,F-0, ►�I R� --l.I- -L) mo C;m KE - ILil7l�Tla� woo I 11 ANY ZONE ' THERMOSTAT MAY USE. THE REMOTE ROOM THERMOSTAT SENSOR � PPTION. 2 . LOCATE: AIRFLOW SENSOR IN FIRST;, STRAIGHT SECT�IbN OF MAIk DUCT AFTER , rHE BY-PASS' DUCTS . AND ' BtFORM • THE .FIRST ZONE DAMPER. 3,186 RELAY_ PACK IS MOUNTED IN ZONE: ; DAMPER.. CONTROLLED BY MASTER MDNITOR THERMOSTAT. 0 4. ALL LINE WIRING BY ELECTRICAL_, ALL LOW VOLTAGE WIRING BY MECHANICAL. t 5. . ALS 'i THERMOSTATS.i SHALL BE PROV,IQED WITH A EY -PAS - `TIME : Lj tjI -'_ 24 - VA.-- 2L P^"K- " r,TH `ne ct-ocK- Lxx/ -Te�: i N X 08 ?.A VAS _ ZD VIA, M I eye r-� T by FAhS ' C.6Jtevu:e9 L-�i.o�l sE�R 10-5L1PvLv alcr.00 P -00F tetras ----- WIRING DIAGRAM FOR,A/C 9 &2 GE -NERAL NOTES 1. ALL WIRING, CONDUIT AND "E" ITEMS SHALL BE FURNISHED AND INSTALLED UNDER THE ELECTRICAL SECTION OF THE SPECIFICATION. 2. ROOM THERMOSTATS SHALL BE LOCATED 44" ABOVE FINISH FLOOR. SETTING SHALL BE 78°F - 750F HEATING. HEIGHT DIMENSION SHALL BE TO CENTERLINE OF THERMOSTATS. 3. ALL THERMOSTATS SHALL HAVE NO VISIBLE THERMOMETERS AND SHALL BE TAMPERPROOF. CONTROL LIMITS SHALL BE FROM 550F TO 850F. 4. ALL THERMOSTATS SHALL BE OF THE AUTOMATIC CHANGEOVER TYPE TO SEQUENCE HEATING AND COOLING. ADJUSTABLE TEMPERATURE DIFFERENTIAL SHALL BE 1/20F. 5. CONTROLS SHALL HAVE THE CAPABILITY OF TERMINATING ALL HEATING AT A TERMPERATURE NO MORE THAN 70°F, AND ALL COOLING AT A TEMPERATURE NOT LESS THAN 780F. 6. REFER TO MANUFACTURER'S MANUAL FOR RECOMMENDED FUSE AND WIRE SIZES. 7. TRANSVERSE AND LONGITUDINAL JOINTS SHALL BE SEALED WITH MASTIC. 8. A MAINTENANCE LABEL SHALL BE AFFIXED TO MECHANICAL EQUIPMENT AND A MAINTENANCE MANUAL PROVIDED FOR OWNER'S USE. 9. NEW SUPPLY AND RETURN AIR DUCTWORK TO BE INSULATED PER SCHEDULE. EXTERIOR DUCTS SHALL BE LINED. 10. ALL RECTANGULAR DUCT 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 11. ALL INSULATIONS SHALL HAVE A FLAME SPREAD OF 25 AND A SMOKE DEVELOPED RATE OF 50 AS FOLLOWS: A. DUCT INSULATION PER UMC 1005 B. PIPING INSULATION PER UMC 2127 (8) 12. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY -FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE • SUPPLEMENTALLY SECURED WITH A DRAW BAND. 13. FLEXIBLE DUCTS SHALL CONSIST OF AN EXTERIOR REINFORCED LAMINATED VAPOR BARRIER, 1-1/2" THICK FIBER GLASS INSULATION (k=.25 @ 750F), ENCAPSULATED SPRING STEEL WIRE HELIX AND IMPERVIOUS, SMOOTH, NON -PERFORATED INTERIOR VINYL LINER. INDIVIDUAL LENGTHS OF FLEXIBLE DUCTS SHALL CONTAIN FACTORY FABRICATED STEEL CONNECTION COLLARS. FLEXIBLE DUCTS SHALL BE USED ON ONLY THE LAST 6' MAX. TO THE AIR OUTLET. 14. FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12" DIAMETER, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. DUCT TAPE SHALL NOT BE USED. 15. FLEXIBLE DUCTS SHALL NOT PENETRATE THROUGH ANY WALL. 16. FLEXIBLE DUCTS MAY BE USED TO CROSS SEISMIC JOINTS WITHOUT OFFSETS. 17. ALL DUCTWORK SHALL BE INSTALLED TO ALLOW CLEARANCE IN CEILING SPACE FOR LIGHTS (INCLUDING INSTALLATION), FIRE SPRINKLER SYSTEMS, AND ALL STRUCTURAL OBSTRUCTIONS NOT SHOWN ON MECHANICAL DRAWINGS. MECHANICAL CONTRACTOR SHALL VERIFY ALL REQUIRED CLEARANCE WITH APPROPRIATE DISCIPLINES AND REPORT ANY FORESEEN PROBLEMS BEFORE BEGINNING INSTALLATION OF ANY DUCTWORK. 18. AIR HANDLING DUCT SYSTEMS SHALL BE CONSTRUCTED, INSTALLED, SEALED AND INSULATED AS PROVIDED IN CHAPTER 10 OF THE STATE MECHANICAL CODE (TITLE 24, PART 4). 19. PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL SYSTEMS PER "SMACNA" GUIDELINES. 20. ALL FIRE DAMPERS SHALL BE APPROVED AND TESTED IN ACCORDANCE WITH SFM STANDARD 43.2 C.C.R. T-19. 21. FRESH AIR REQUIREMENTS PER ASHRAE STANDARDS 62-1981. 22. FRESH AIR INTAKE OPENINGS SHALL BE AT LEAST 10 FT. AWAY OR 3 FT. BELOW EXHAUST OPENINGS OR PLUMBING VENTS. 23. EXHAUST FANS SHALL BE INSTALLED WITH BACKDRAFT DAMPERS AND DISCONNECTS. RECORD DRAWING THESE RECORD DRAWINGS (AS -BUILT DRAWINGS) HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, WOLFF/LANG/CHRISTOPHER ARCHITECTS, INC., HAS NOT VERIFIED THIS INFORMATION AND IS NOT RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, NOR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT. AIR DISTRIBUTION SCHEDULE SYMBOL DESCRIPTION MANUFACTURER CD CEILING DIFFUSER KRUEGER MODEL 6000 W/OBD SP SUPPLY REGISTER (SIDEWALL) KRUEGER MODEL 1600 TYPE 4 FASTENING W/OBD RR RETURN REGISTER (-ID-.::WALL) KRUEGER MODEL 1600 TYPE 4 FASTENING W/O OBD RAR I1 'TURN ' TF. REGISTER (C,",IL_NG) KRUEGER MODEL EGC-5 W/OBD E7!,R :XH.'.US' AI1' R}: JISTER f C.: '7I-ij NG) KRUEGER MODEL EGC-5 W/OBD MP► -.do. Brio ESR CXH. ASF, ( kA -U- MT),1 D.). CITY OF FONTANA FIRE STATION NO. U �W':lCIrJ n ��ttttt�■� • • �--� FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT CONSULTANT JON HAMMOND ENGINEERS Enokw9ruv cwt 2472 Chwnben Road, sune 1!0 Tusdn, CA $2600 (714) S44-OOM =TITTLE SHEET DRAWN ISD, CHECKED J.,ft zm��,-I DATE SCALE Sf 9 I E JOB NO. 90 2-300 =TITTLE SHEET DRAWN ISD, CHECKED DATE SCALE Sf 9 I E JOB NO. 90 2-300 M=1 W C7, Na, '2,3%`7