HomeMy WebLinkAbout2366-l-20 z z D ao TYPICAL BUILDING WALL AUTOMATIC CONTROLLER ASSEMBLY TO BE WALL MOUNTED COMMON WIRE SHALL BE TIED INSIDE HOUSING WHEN REQUIRED ON-OFF SWITCH TO BE PROVIDED BY CONTRACTOR SLEEVE FOR CONTROL WIRES PROVIDED BY GENERAL R (2'e ) ELECTRICAL CONDUIT TO INDEPENDENT SOURCE ( CONTROL UNIT ELECTRICAL REQUIREMENTS :115V. , 60 CYC, 2AMPS MAX.) NOTES: I. COMMON WIRE 110 BE WHITE 8 CONTROL WIRE TO BE BUCK IN COLOR. 2. NO SPLICES SHALL 8E MADE BETWEEN CONTROLLER 8 REMOTE CONTROL VALVE. S. CONTROL WRING SEQUENCE CORRESPONDS TO OPERATING SEQUENCE OF REMOTE CONTROL VALVES 8 AUTOMATIC CONTROL- LER UNIT STATION CONNECTION ( SEE IRRIGATION PLAN FOR CORRECT VALVE SEQUENCE) . AIGHT CONDULET FOR WIRE CONNHTIONS VG WIRE NUTS L TAPE - TAPE Y MZlN13S AT INTERVALS OF 4 CENTER CONTROL WIRING ( AWG OF TO CONTROL UNIT AT TERMINALS tE TO ALL R. C. V. I S u vvn . ►ova- w. ARE TO EACH R.C.V. TYPICAL AUTOMATIC CONTROLLER ASSEMBLY NO SCALE ( WALL MOUNTED TYPE ) J.R.-84 M. '�� : i • _ r. • qtr NOTE: • EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 12" FROM WALLS,13LDGS, M. • WHEN UNIT IS NEXT TO BUILDING, WALL, ETC, TEST COCKS ARE TO BE ON OUTSIDE. • ALL UNDERGROUND- PIPES SHALL BE DOUBLE WRAPPED WITH -APPROVED TAPE WHEN USING GALYV, STEEL PPE. TYPICAL BACKFLOW PREVENTER ASSEMBLY NO SCALE (2 1/2" AND SMALLER) JR -85 SIDEWALK, CURB, ETC. . -m*11,1 SPRINKLER NOZZLE POP -UP BOW ASSEMBLY (INSTALL 1/2!' ABOVE FINISH GRADE) -PVC SCH. 80 NIPPLE SIZE AS REQUIRED PVC SCH. 40 STREET ELBOW PVC SCH. 40 ELBOW PVC SCH. 80 NIPPLE ( SIZE AS REQUIRED) IN FINAL POSITION RISER SHALL BE AT A 45° ANGLE r PVC SCH. 40 STREET ELBOW LATERAL LINE( SIZE AS NOTED ON DRAWING) NOTE : USE TEFLON TAPE ON ALL THREADED FITTINGS 7 TYPICAL LAWN HEAD ASSEMBLY QUICK COUPLING VALVE SET FLUSH WITH FINISH GRADE IN LAWN AREA SIDEWALK, CURB, 3"ABOVE FINISH GRADE ETC. �,., IN OTHER AREAS SIDEWALK, CURB, �►'' FINISH GRADE ETC. rir 0 JA�' • LAWN AREAS �. , y . iFINISH GRADE MOR ` •�'� t + + SHRUB AREAS BOX TO BE PLACED AT RIGHT ANGLE TO IZ ,..�. tt♦+ tt�++ • ,• t t J, ++++ . HAF�SCAPE EDGE . • • • ` +t*t-++ ++}t+{ 12" ROUND PLASTIC 12"x 18"PLASTIC BOX AND COVER WITH :�� '`••' •'• • • +tt+ +4- BOX 8 COYER LOCK TOP - �.• J + + CURL TYPE EXPANSION LOOP(MIN. 24) STAINLESS STEEL CLAMP y t y WATERPROOFED WIRE CONNECTION IZ C K - CHRISTYS I.D. TAG (STANDARD)y ;� NON -PRESSURE r d 1 SECURE TO SOLENOIDY" LINE FITTING ` b9 SIZE 8 LENGTH AS REQ D PIGTAIL ~ ` ` I �� SCH. 60 PVC NIPPLE FINISH GRADE ' I 3 ,, 3/4" -PEA GRAVEL LAWN AREA : • q - , SCH. 40 PVC+� •; • • PVC LINE PIPE ! ELBOW ,ti ; '•4 ���✓ SCH. 40 PVC STREET ELBOW FINISH GRADE 4 1" •� SHRUB AREA SOLENOID 3 .• : • •' a•� PVC SUPPLY SCH. 80 PVC NIPPLE *" • :r • •. , FLOW ADJUSTMENT i LINE (SzSxT) SIZE LENGTH AS REQ ' D .. '.'i. ,, FITTING �1.,,.� '4 / �.�yti 3�t4 PEA GRAVEL • ( MIN. 3 CU. FT.) �e PVC SCH. 40 MALE ADAPTOR PVC SUPPLY LINE (TYP. 2 PLACES) , 14 PVC LINE PIPE PVC ELBOW 18 PVC LINE PIPE PVC SUPPLY LINE FITTING (SXSXS)SCH. 40 PVC STREET ELBOW COMMON WI RE CONTROL WIRE NOTES 1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED. NOTE : USE TEFLON TAPE ' � 1-I/2 PVC PIPE STAKE 2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF � ON ALL THREADED (SCH.40) 3 FT APART. FITTING MIN. 36" LONG OR AS SITE 3. USE TEFLON TAPE ON ALL THREADED FITTINGS. REQUIRES Z NTYPICAL REMOTE CONTROL VALVE ASSEMBLY TYPICAL QUICK COUPLING VALVE NO SCALE ( STRAIGHT TYPE) JR -85 NO SCALE ASSEMBLY JR -103-0 "• _.., ..yam,•. {� �-�-_ •-'.�'M•�'- ROUND PLASTIC BOX 8 COVER COVER MARKED: IRRI GATE �e FINISH GRADE LAWN AREAS FINISH GRADE SHRUB AREAS HANDWHEEL e_PVC SUPPLY LINE 9/4"PEA GRAVEL (MIN. 2 CU. FT.) GATE VALVE PVC MALE ADAPTORS NOTE: GATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED. TYPICAL GATE VALVE ASSEMBLY NO SCALE (3 AND SMALLER) JR -84 �•� 40 �/• ••� 12" -I--PVC TEE OR ELBOW (Sx SxT) FINISH GRADE 12" xSxT) ►C T[E OR .BOW -, A INKLER NOZZLE POP- UP BODY ASSEMBLY 1/2" ABOVE FINISH GRADE) PVC SCH. 80 NIPPLE ( LENGTH AS REQUIRED) LATERAL LINE (SIZE AS NOTED ON DRAWING) SCH. 40 PVC S ET ELBOWS NOTE: USE TEFLON TAPE ON ALL THREADED FITTINGS TYPICAL SHRUB HEAD ASSEMBLY NO SCALE ( POP - UP TYPE) JR -84 GENERAL IRRIGATION INFORMATION CITY STATIC PRESSURE: HIGH 109 P.S.I., LOW 69 P.S.I. RESIDUAL STATIC PRESSURE : 9 P.S.I. METER SIZE: P.O.C. SUPPLIED BY MECHANICAL CONTRACTOR PEAK IRRIGATION DEMAND: 55 G.P.M. MAX. G.P.M. FOR EACH VALVE: NOTED ON PLAN FINISH GRADE AT BACKFLOW UNIT: 26.70 HIGHEST HEAD SERVED : 27.20 PRESSURE CALC'S FOR WORST CONDITION SEE HYDRAULIC CALCULATION CHART TOTAL LANDSCAPE AREA: 34,292 SQ. FT. GENERAL LEGEND .SYMBOLS DESCRIPTIONS MANUFACTURER &PART NO. REFERENCE P, QC POINT OF CONNECTION GPM SPECIFICATION 2d NOZ. REFERENCE 900 PRESSURE SUPPLY LINES &SIZE 2"& SML SCHEDULE 40 P.V.C. SPECIFICATION ye, 0.50 RAINBIRD SAM 1802 5Q-13 NON -PRESSURE LINES S SIZE CLASS 200 P.V.C. SPECIFICATION 5' SLEEVES SCHEDULE 40 P.V.C. (2 X DIA. OF PIPE) 30 A I j CONTROLLER SEQUENCE 1802 5H -B DETAIL NO.6 GALLONS PER MINUTE 900 8' yz" REMOTE CONTROL VALVE SIZE 30 0.40 RAINBIRD SAM AUTOMATIC CONTROLLER RAIN BIRD LSC 24 DETAIL NO. 1 Q REMOTE CONTROL VALVES RAIN BIRD G SERIES DETAIL NO.2 0 -- QUACK COUPLING VALVES RAIN BIRD 3RC DETAIL NO.3 -- BACKFLOW PREVENTION ASSEMBLY WILKINS 575 DETAIL NO.4 w GATE VALVES --LINE SIZE NIBCO T136 DETAIL NO.5 30 PRESSURE REGULATOR WILKINS 500 SERIES DETAIL NO.4 SPRINKLER HEAD LEGEND SYMBOL ARC RAD TRJ DESCRIPTION PSI GPM MFG. BODY NOZ. REFERENCE 900 5' 0 STREAM BUBBLER HEAD 30 0.50 RAINBIRD SAM 1802 5Q-13 DETAIL NO.6 cl 1800 5' 0 STREAM BUBBLER HEAD 30 1.00 RAINBIRD SAM 1802 5H -B DETAIL NO.6 O 900 8' 5 5° FLAT SHRUB HEAD 30 0.40 RAINBIRD SAM 1806 8Q -FLT DETAIL NO. 6 1800 8' 5 5° FLAT SHRUB HEAD 30 0.80 RAINBIRD SAM 1806 8H -FLT DETAIL NO. 6 X -- 3600 8' 5 5° FLAT SHRUB HEAD 30 1.60 RAINBIRD SAM 1806 8F -FLT DETAIL NO. 6 v 900 10' 15 LOW ANGLE SHRUB HEAD 30 0.40 RAINBIRD SAM 1812 100 -LA DETAIL NO.8 v 1800 10' 15 LOW ANGLE SHRUB HEAD 30 0.80 RAINBIRD SAM x812 10H -LA DETAIL NO. 8 -- - X 3600 10' 15 LOW ANGLE SHRUB HEAD 30 1.60 RAINBIRD SAM 1812 10F -LA DETAIL NO. 8 -- 900 8' 5 5° FLAT LAWN HEAD 30 0.40 RAINBIRD SAM 1804 B80 -FLT DETAIL NO. 7 - - 1800 8' 5 5° FLAT LAWN HEAD 30 0.80 RAINBIRD SAM 1804 B8H-FLT DETAIL NO. 7 --- �- 900 10' 5 LOW ANGLE LAWN HEAD 30 0.40 RAINBIRD SAM 1804 100 -LA DETAIL NO. 7 C 1800 10' 15 LOW ANGLE LAWN HEAD 30 0.80 RAINBIRD SAM 1804 10H -LA DETAIL NO. 7 Qi 3600 10' 15 LOW ANGLE LAWN HEAD 30 1.60 RAINBIRD SAM 1804 1 OF -LA DETAIL NO.7 m 900 15' 30 STANDARD LAWN HEAD 30 0.95 RAINBIRD SAM 1804 15Q DETAIL NO. 7 ® 1800 15' 30 STANDARD LAWN HEAD 30 1.85 RAINBIRD SAM 1804 15H DETAIL NO. ® 360° 15' 30 STANDARD LAWN HEAD 30 3.70 RAINBIRD SAM 1804 15F DETAIL NO. 7 NOTE:. USE PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED 25% OR MORE AND RECORD ON AS BUILTS. POP-UP ASSEMBLY (INSTALLED I ABOVE FINISH GRADE IN OPEN AREAS OR AS NOTED) SCH.40 PVC STREET ELBOW SCH.-SPVC ENGT AS RIEQ�DE RECORD DRAWING r SCH. 40 PVC STREET ELBOWS THESE RECORD DRAWINGS (AS -BUILT DRAWINGS) HAVE BEEN PREPARED BASED ON INFORMATION NOTE, SUBMITTED, IN PART, BY OTHERS. WHILE THIS I. INSTALL HEAD FLUSH WITH TOP OF HARDSCAPE AT INTERSECTION a CORNERS. INFORMATION IS BELIEVED TO BE RELIABLE, ER WOLFF/LANG/CHRISTOPHER ARCHITECTS, INC., 2. USE TEFLON TAPE ON ALL THREADED FITTINGS. HAS NOT VERIFIED THIS INFORMATION AND IS NOT RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, NOR FOR ANY ERRORS OR OMISSIONS WHICH MAY S TYPICAL SHRUB HEAD POP-UP ASSEMBLY HAVE BEEN INCORPORATED INTO THESE It NO SCALE -137 DOCUMENTS AS A RESULT. -A G5 HYDRAULIC CALCULATIONS �� AHPROI2CT:- �.T4 HYDRAULIC ORADWa?r (ELV.) MIN. MAX. HOUSE DEMAND CITY WATER P URB (P.S4:) MIN. _ MAX._ 11 mmm mmm rl■■li��r�l �I��vnn mc?'Imm ON 10 m C ammmmI .f mm mm mmm mom mmm 1 J671 AI T UOULATIM WAM PRESSURE P.M. P-31. PUMP r P7. mi 1) PAJl r s L rftRSSURr-()AM MJR 7'0 VA1 u11 1;ILIiN'flAl. P41 PS.L_. i TOTAL AVIALAMLI! PRILIMU P.S.I.r P.a.l. (-) TOTAL IWIJON LOSS93 t S 1. PSJ. KSMAlI4M r Sd. Mi. POR PSI itl'.SIDUAL XMW AT SKJNKLi7t 11UD N* P.S.1 KHS=AL NnPDp AT SPltM.UR HEAD f rl■■li��r�l �I��vnn CITY OF FONTANA FIRE AND POLICE CONTACT STATION NO. 00 00 FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT FONTANA POLICE DEPARTMENT GONSULTANT RJM ' DESIGN GROUP, INC. PLAWNG AND LANWAPt ARCHITECTURE MW W RAMN" {. •UNTIE M. M120M V%". CA. "101 If 14 M-"14 a �. IRRIGATION DETAILS/LEGEND DRAWN A.I.C. CHECKED B.0 . DATE '9/90 SCALE .108 NO. 8913000 L-2