Loading...
HomeMy WebLinkAbout2366-l-18 14 32 t 26 DIU I I LIVI I.'Zi NU I AL;UtF' I tU by UWNtM. .w Nm --A -R u A 5 4u A 4 MASONRY STORAGE BUIDING-ADDITIVE, _ AN NO.1 SEE DETAIL THIS SHEET FOR IRRIGATION LAYOUT IF ALTERNATE BID ITEM IS NOT ACCEPTED BY OWNER. GENERAL NOTES 1. INSTALL ALL PRESSURE AND NON -PRESSURE LINES AND ANY EQUIPMENT INSIDE PLANTING AREAS WHEREVER POSSIBLE. (ITEMS SHOWN OUTSIDE SUCH AREAS FOR PURPOSES OF CLARITY ONLY.) I ALL EQUIPMENT SHALL BE SELECTED AND INSTALLED IN ACCORDANCE WITH SPECS. AND CONSTRUCTION DETAILS. SEE SHEET NO. L-2 & FOR SYMBOL DESIGNATION, SEE LEGEND ON SHEET NO, L-2 4. WHERE PRESSURE REGULATING VALVES ARE USED, VALVESARE TO BE ADJUSTED FOR OPTIMUM PRESSURE, OR AS NOTED ON DRAWING. S. ADJTALL SYSTEMS TO AVOID SPRAY ONTO BLDGS, WALKS, AND ROAD- WAYS BY INDIVIDUALLY ADJUSTING SPNKLR HDS AND CONTROL VALVES. 6. AREAS THAT NEED TO BE DEFINED IN ORDERYO DETERMINE EXACT LOCATION OF SPNKLR HDS ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO SEE THEY ARE DEFINED PRIOR TO INSTALLATION. 7. AS -BUILT DRAWINGS AND SPECS. SHALL BE MAINTAINED ON SITE AT ; ALL TIMES. AS -BUILT DRAWINGS SHALL BE UPDATED ON DAILY BASIS. NO SITE REVIEWS ARE TO BE CONDUCTED WITHOUT THESE DRAWINGS. & AREAS RECEIVING AN IRRIGATION SYSTEM SHALL BE REVIEWED AND VERIFIED BY THE INSTALLING CONTRACTOR FOR ACCURACY OF SIZE AND CONFIGURATION. IF DISCREPANCIES ARE FOUND THAT WOULD PROVE DETRIMENTAL TO FINAL COVERAGE, THIS SHALL BE BROUGHT TO THE OWNER'S ATTENTION BEFORE INSTALLATION. BY FAILING TO DO SO, THE CONTRACTOR MAY BE RESPONSIBLE FOR ANY ADJUST- MENTS REQUIRED. 9., MAIN LINE HYDROSTATIC WATER. PRESSURE TEST AT 150 PSI FOR 3 HOURS. 4 A3 �;l iy,7u 0 SYSTEM DESIGN CRITERIA • SYSTEM DESIGN IS BASED ON 60 P.S.I. USING 55 G.P.M. • PRESSURE DATA WAS OBTAINED FROM FONTANA WATER DEPART- MENT BY DOMENICK SCHARETTI ON 6/18/90 . , WHOSE PHONE NUMBER IS (714) 822-2201 • CONTRACTOR'fS TO VERIFY THIS INFORMATION BEFORE INSTALLATION IF DATA VARIES FROM PREVIOUS INFORMATION. CONTRACTOR IS TO NOTIFY OWNER FOR INSTRUCTIONS. FAILURE TO DO SO COULD RESULT W CONTRACTOR BEING RESPONSIBLE FOR CHANGES THAT MIGHT OCCUR. ; NOTE: SEE PLANTING PLAN FOR CONCRETE MOW STRIP LOCATIONS. RECORD_DRAWIN THESE RECORD DRAWINGS (AS -BUILT DRAWINGS) HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE REUABLE, WOLFF/LANG/CHRISTOPHER ARCHITECTS, INC., HAS NOT VERIFIED THIS INFORMATION AND IS NOT RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, NOR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS AS A RESULT. CITY OF FONTANA FIRE AND POLICE CONTACT STATION NO. 74 IV o - ao 00 FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT FONTANA POLICE DEPARTMENT CONSULTANT ItJM DESIGN GROUP, INC. mr w wwAIL putt IM MMM V%W. CA. "M nka i3.116 . .0000 IRRIGATION PLAN DRAWN A.I.C. CHECKED B.C. DATE 9/90 SCALE I"= 2d .108 NQ 8913000 L- 1 D\&jc:,, 'No.-