Loading...
HomeMy WebLinkAbout2366-A2.3CITY OF FONTANA FIRE AND POLICE CONTACT STATION NO. � m 00 00 FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT FONTANA POLICE DEPARTMENT NO DATE BY REMARKS kN A'15' f>UIL-T DRAWN K J CHECKED DATE °I/q0 SCALE NOTM JOB NO. M WOO A 0%. *Aa, . I 'A Pw6e No, 2.366 I META L. '-MO NZAMIko SYSTEMS � - 'x'16 dlYP PO� �F 70 -- - 2� GEIIiW F1eAMINGi - ties METAL SUSPENSION FOR LAY IN PANEL CEILINGS . __ W�WLt,. 4IINC,I o� ALL h}E!GIt{T` �.I+G. FU"INh GNANNEtfs eIIiII0,G, FaItIZINeq G14ANNEL A TO OtGL1R 4rFU6TURAL. GAl31NB1' I°Ei�� �rT'ANI y+" 1, 12 GA. (MIN.) hanger wires may be used for up 14. Ciassifloatkm of calling grid la Heavy duty. . 4 _ _ - _ ... AT I�FIZON'�►L. GEIWNGI eivovfa f�M IIS L,I(1h{ T F{nTUKE to and Including 4'-0" x 4'-0" grid spacing along i~L.F5GT j.IGAL,_ . rnaln runners. 8pikm will not be permitted In Manufacturer Main Runner Cromis Runner any hanger wires unless specifically approved LI CiH T FV TU F E i PP by Amllillltodt Chicago 1870 1854, Metallic Series 1874(2), or 2, Provide 12 ga. hanger wires at the ends of all 1800 1824(1) main and runners 8" from the i ° x W 4 f �.A`�TIG LAMINATE _ II I I 2 x 4 6oNTI W017l1S Ar EA., M NGI ti cross within support or within 1/4 of the length of the end II f-EVEP4. CbIAG '.IN poi N1AX; MA?';--�,, tee, whichever is least, for the perimeter of the Donn Corp. DX26 or DXO-216, 316 coping ares. F DX28 416, 420, Hoot) 4aTu p 0it GONG. MIA w Irl ALO 4► 424, b24 3. Provide trapeze or other supplementary support _ 0 ' Q I ;. ,0 (Q Q , members at obstructions to main hanger V I o spacing. Provide additional hangers, struts or Donn Corp. DXT26 or DXT-218, 418 braces as required at as ceplrtg breaks, soffits, DXT28 424,624 or discontinuous areas. Hanger wires that are I rLp►N NOTE! _ ' E VtSIFY more than 1 in 6 out of plumb are to have Footnotes: counter -sloping wires. Go N D I T' ION '64O W F4 1 S FO �e - t GEI L i . (1) For 2 x 2 grid use 1822 , ' _:. �LL_ __ . _ �. _ _ -_ _ _ .._ _ _ _� �� _Q 4. Ceping grid members may be attached to not (2) For 2 x 2 grid use 1856 : F _....-- _ _ _ _- �• more than 2 adjacent wails. Ceiling grid members should be at least 1/2 Inch free of Notes: other walls. N walls run diagonally to ceilingTYPICAL'CABINET Refer to for 19 t h IiRECESSED i L D LIGHTFIXTURE u I_ d � I D5 AECE5SSED LIGHT" FIXTURE grid system runners, one end of main and cross specifications characteristics or -. CONNECTION AT WALL .. -2-- _ . METAL FRAMING °AT WOOD rRAMING runner should be fres and a minimum of 1/2 grid features which will determine the grid SAT Inch dear of wall. system to be used from the schedule above. GONG IaE TE 5. At the perimeter of the c:elling area where main M AIRY WA�I- or cross runners are not connected to the 2. Alternate manufacturers and systems may II 5/� Giih wApp Oveg Zx(e adjacent wall, provide Interconnection between be substituted for review and acceptance by runners at the free end to prevent lateral t�CU#..8���fl*�18.14�t< PLYWOOD SHEATHING Ito o,G, spreading. A metal strut or a 16 ga. wire with a Zx ROOF FRAMING positive mechanical connection to the runner may be used. Where the perpendicular kl*PEhInEP AGoWIGAt GEII., distance from the wall to the first parallel runner 16. Anchors for wall Angios: OR �iP asp, �P�L.INI� WFIs}�E C�G11�5, Is 12' or less„ this Interlock is not required. z CRIMP TOP OF TUBING FLAT AND � (D X12 x LONG : A. At wood stud Wali: 4d common nap @ 6. Provide sets of four 12 ga. splayed bracing I 6" OC . R.H.WITH . (TY � LONG RW000 SCREWS. (TYP.) -- I x 4 WI �'t..Ah T I G Lf M I IJp T� from wires oriented 90 degrees m each other at not mon than 12 feet by 12 feet on enter. B. At metal stud wail: 1-1/8' type "S" bugle 1/2. DIA. x 14 GA. ST4 TUBING 1 head drywall screw at 16" OC. Provide bracing wires at locations not more - d - than 1/2 of the spacings given above from each At masonrywall: 1 /4" dia. x 1-i /2" � long perimeter waft and at the ed of vertical ceilingC. Pe anchor screw @ 16" OC. . offsets.tapcon i SECURE TUBE SECTIONS T ER z WITH (2) SET SCREWS • �A>Z I -►NE 0F GI`(j', PyOA�v G�-it-INQ°I The slope of these wires should not exceed 45 1° a 70 FAW1144 G1iANNEt4 z- : SEE IN TBRIoIR ;; E E 4t'1'`It N degrees from the plane of the ceiling and be taut lin. @ I (v o. G. II ; t should without causing the cuing to • er _ � 3/4 OLA. X 14 GA. STL. TUBING. _ ���_ �I�E� 2i1 TYPic�tt, IN Mo✓T Splices In bracing wires are not to be permitted wflhoIt spec Woval. CRIMP BOTTOM FLAT AND ATTACH TO MAIN RUNNER WITH �►t2' II ;� 14 �`r ��i� cASE�, SEE INrE 1'zioleSHEET METAL SCREWS. �2) TYP.) I ELS,/AT10Ns FOfa VA�IAT046, ' • �� METAL ENS - MPINTPIN GRISP 'ANP GOW PIST�NT LINE AT : WAG Fi111�il� Q°►!`�ItJET rE� rsKIMsTRK 0fr juoM iI5 W 1, , ':faTo4 P ARPra 7. Fasten hanger wires with not Isas than 3 tight toms Fasten bracing wires with 4 tight fume. Make COMPRESSION GO M � R E � O � NONE 'PERIMETER � E R I M E T E R DETAIL AT FULL FFIT X"'6CAw"'INETu E` I II I 2 all tight turns within a distance of 1-1 /2 STRUT CEILING Inches. Hagor bracing wire anchors to the JOIST or RAFTER ,101ST or RAFTER. structure should be Installed In such a manner that the direction of the wire aligns as closely as possible with the direction of the forces acting Required �- Kbrace ��'«,y. on the wire. 8. Separate all celling hanging and bracing wires ` 2 -16 d rob typ ea. end. at least 6 Inches from all unbraced ducts, pipes, conduit, etc. it Is acceptable to attach lightweight items, such as single electrical � STAPLE � �` � exceeding 3/4" nominal diameter, to x 1 1e 44. ,Sg conduit not hanger wires using connectors acceptable to NAIL' at � Toopa ,J,�� SCREW EYE s w( tult thread embed ►� SPLAYED „ g SADDLETIE i • 9. Attach all light fixtures to the ceiling grid runners HANGER WIRE. w 4•dia. drilled hole. / to resist a horizontal force equal to the weight HANGER WIRE: of the fixtures. ROOF DECK. wtt 3 PVEWA& SPLWIRE 10. Mush or recessed light fixtures and air terminals W1 4 tight turns. or services weighing less than 66 pounds may be supported directly on the runners of a heavy duty grid system but, In addition, they must �`"` have a minimum of two 12 ga. slack safety -- ,.i "` - ,.ice .- - .,� �'" STRUCTURE. wires attached to the fixture at diagonal comers 9 1 LIGHT FIXTURE • HEAVY- DUTY GRID TIE' and anchored to the structure above. All 4 ft. x v,4 -12 ga. hanger wires alternate corners to w,rcg 2 ga. wire structure. tyaround 4 ft. light fixtures must have slack safe wires at -� structure above.,_ �`, �' each corner. A!R . ? .�C� HANGER or BRACE. 1 ha�ngerR wires at Li�gr�cTEixtures or d' in JOISTcrRA!"TER. All flush or recessed light fixtures and air awlternate corners to excess of 56poun ss r` q 0 structure sieve. 4->? Qct. hanger wires. V4 RL�V ', terminals or services weighing 56 pounds or dia. wl hill thread en�Ded. more must be independently supported by not SPLAYED BRACE WIRE. less than 4 taut 12 ga. wires each attached to the fixture and to the structure above regardless the type of celling CONNECTION AT LIGHT NCNB TYPICAL PLAY WIRE NONE TYPICAL HANGER WIR NON6of grid system used. ,N AIR DI US CONN. AT WOOD FRAMING CONN. AT WOOD FRAM1G �IXTUR The 4 taus 12 ga. wires Including their attachment t0 the structure above may be Capable Of BUpporting 4 times the weight Of the 12 GA. SPLAYED BRACE WIRE WITH 3/4* e X 14 GA. STL. TUBING. CRIMP FACE OF WALL. unit. MIN. (4) TIGHT TURNS IN 1-1/2". BOTTOM FLAT AND ATTACH TO MAIN HANGER WiRE. 64 enc MAIN CRCRCSS ea. end. min. COMPRESSION STRUT 45' WITH RUNNER. SEE 12 GA. VERT. HANGER i p WIRE O 4'-0o O.C. (2) #12 S.M. 45' SCREWS. (TYP.) 11. All fixtures and air temmirnals orservices _ WITH MIN. (3) TiGHT -' TURNS IN 1-1/2w.N oe 0Z supported on Intermediate duty grid systems must be Independently supported by not less 4 k ..., .r .�. .. Y •' ' • ` ' than 4 taut 12 ga. wires each attached to the fixture or terminal and to the structure above. AfvOUST. PANEL.. ANGLE SPACER 45' 45' POP RIVET. notched at rumor?fttt-' 12. Su surface mounted I ht fixtures b at y 45' WALL ANGLE. rail•(sseenot�• c2 ) er to location vyo WALL CONNECTION- least two positive devices which surround the nada ceiling runner and which are each supported • 45' SEE INSTALLATION NOTES from the structure above by a 12 ga. w1re. RECORD DRAWING Spring dips or damps that only to the 45 MAX. WIRE* connect MAX.HANGER M 12 GA. w 3 tight turns. runner are not acceptable. THESE RECORD DRAWINGS (AS -BUILT DRAWINGS) MAIN RUNNER. HAVE BEEN PREPARED BASED ON INFORMATION Provide addkkxW supports when light fixtures 27 CROSS RUNNER. ' are 8 feet or longer. SUBMITTED, IN PART, BY OTHERS. WHILE THIS M�,x• INFORMATION IS BELIEVED TO BE RELIABLE, WOLFF/LANG/CHRISTOPHER ARCHITECTS, INC., ACOUST. PANEL. ' 13. Support pendant mounted light fixtures directly from the structure above with hanger wires or HAS NOT VERIFIED THIS INFORMATION AND IS NOT MAIN RUNNER 2- MAX. FROM PERPINDICULAR�'• CROSS RUNNER • �• ' • r• ��_ ~ • � ' � • ,• � � � '� cables passing through each pendant hanger RESPONSIBLE FOR ITS ACCURACY OR ADEQUACY, g NOR FOR ANY ERRORS OR OMISSIONS WHiCH MAY BRACE WIRES TO 4' DIM. TO CROSS MAIN 12 GA. SPLAY MARE BRACING IN NC3TES� and capable of supporting 4 tines the weight Of HAVE BEEN INCORPORATED INTO THESE fixture. RUNNERS. CROSS RUNNER a 2'-0' O.C. RUNNER PLANE OF EACH RUNNER - VERT. ANGLE o 45' (TYP.) (1) 0' msec. cr4 1 of the length d the end ter, Is len.the DOCUMENTS AS A RESULT. (2) _••_, Mks Aced WlIg nhffi� � r10a span- d strut. tCEILIN'0'�L.l�. tj UT N o P!� <,. :4 N N o N� TYPICAL NONE N CITY OF FONTANA FIRE AND POLICE CONTACT STATION NO. � m 00 00 FONTANA COMMUNITY DEVELOPMENT DEPARTMENT CENTRAL VALLEY FIRE PROTECTION DISTRICT FONTANA POLICE DEPARTMENT NO DATE BY REMARKS kN A'15' f>UIL-T DRAWN K J CHECKED DATE °I/q0 SCALE NOTM JOB NO. M WOO A 0%. *Aa, . I 'A Pw6e No, 2.366