Loading...
HomeMy WebLinkAbout2358-1r • ■ ■ k , PROJECT ,r 711: 1: ol .7 1 =I OWNER. r ' 13ARCLAY OR CEN 230 NEWP T TER DRIVE NEWPORT BEACH CAN 92660 SYMBOLS i ■ ■ ■ ■ 4 CODE TABULAT IN ION CONSULTANTS. ■ ■ ■ DEX • O CIVIL ENGINEER HALL & FOREMAN, INC. DRAWINGS REFLECT 1985 U.C.B. ARCHITECTURriL 3170 Redhill ,;esti Mesa, -California 92626-4675 A-1 Tit'e Sheet 7'4/641-8777 � A. Occupancy Group A-2 Mail: Flcor Plan Gymnasium A3 A-3 2nd d oor DI an & )artial Roof Plat, Recreation Center B2 A-4 Exterior Elevations STRUCTURAL ENGINEER No separation required A-5 Exterior Eley ,t• • -is ,ZOBERT LAWSON A-6 Building Sec;4ons A_7 Interior E1 e'✓c.t; oris 312 Ocean Avenue B. Type of Construction A-8 Interior _Ia✓E.t c.IS :.aguna Beach, California 92651 74/494-0776 Type V, Sprinklers A-9 Interior :_levatio•-.s & L'e~ails . A-10 Wall Sec . ( n A-11 Details C. Building Location: A-12 Details See Landscape and Civil Drawings. A-13 Schedule MECHANICAL ENGINEER ��- D. Floor Areas: 1HTr910r- . o► RICHARD APALMER & ASSOCIATES • Occupancy Group A3 (Gymnasium) STRUCTURAL no. dab ler 1910 E. Wa;ner Avenue, Suite A 4109 sq. ft. ' Santa Ana, California 92705 First Floor B2 4508 sq. ft. S-1 Details/General Notes 714/261-5704 rwlsNon � Second Floor B2 1040 sq. ft. �-2 Foundation Plan S-3 Roof Fram ng P1ar: t )etai►s - 9657 sq. ft. S-4 Details ELECTRICAL ENGINEER . E. Building Hts . ;.L.:CT^ICA.. DALE KARJALA & ASSOCIATES A3 One Story 42' 3185-C .Airway Avenue B2 Two Story 27' F-1 E''ectrir_al Site Plan ' Costa Mesa, California 92626 E-2 F ; rst Floor Electrical P1 to A sand Pkwvws L. Paul Zalfen 714/751-1851 E-3 Second Floor Flectrical Fian F . Occupant Load 260 Newport center Drive A3 273 suite 100 _ - B2 178 f�iECHAN I CAL •Newport Keach, CA. LANDSCAPE ARCHITECTS — 926110 (714) 760-31138 M-1 First Floor HVAC Plan LAND/PLAN/DESIGN GROUP M-2 Second Floor HVAC Plan Wo F- 2-30 Newport ' Clsrlter' Drive" 5ui to 200 M-3 HVAC Notes, Detai 1 s & Schedules Newport Beach, CalifornTa 92660 F-1 Plumbing Site Plait %'� P-2 First Floor Plumbing Plan / P-3 Second Floor Pl umni ng P'l ar. 1 1 r CIVIL C-1 Site & Grad4tig Plate project title -f- ■ DETAIL REFERENCE detail numberVICINITY MAP HERITAGE -3 i sheet number fon detail is shown) - Abv. Above RECREATION, Q At Lam. Laminated 3 detail number Bm. Beam Lay. Lavatory DETAIL REFERENCE q- -�---- - sheet number CENTER Cab. Cabinet Lum. Luminous (two story foundation only) Clg. Ceiling M.C. Medicine Cabinet / Clr. Clear Min. Minimum Conc . Concrete Mtd . Mounted section letter D r . Door Mt 1 . Metal _ BVILDiNG SECTION REF. D.S. Downspout O.C. On Center A_ Sheet numberj Diets. Details Pl . Plate PROJECT LOCATION MAP CONDTTIONS OF APPROVAL. D.W. Dishwasher P.L. Property Line ' E a . Each P 1 ywd . P 1 ywood CASE: Resign Review #890 Elev. Elevation R Riser PROJECTDATE: January 13, 1986 Exh. Exhaust Rad. Radius DOOR REFERENCE AO -�---- door letter SIT C- ,�� shoot title Ext. Exterior Ref. Refrigerator - �� 1. All sndar0 conditions of approval contained wiihln Plant) Ing Conunission Resolution No. Eq. Equal Rm. Room ta85-39 regarding design tevieO� for multifamily residential shall apply accepting therefrom conditions numbers 8, 13, 14, 23, 27 and 28, F.A.U. Forced Air Unit S&P Shelf and Pole F.G. Fixed Glass S.D. Snake Detector Highland Ave F.J. Fl oor Joist Sim. Similar WINDOW REFERENCE 2 -+-- -- - -- window number o� 2, All exterior lighting fixtures shall be subject to review and approval of the Director of Fl r. Floor S1. G 1, Sliding G1 a s sa utherm Pacific Rallroa Fluor. Fluorescent Typ . Typical Baseline Road Planning. '��*�• Ftg . Footing U.N.O. Unless Noted Otherwi se A 3. Compliance with all applicable conditions of tho West End Specific flan/ EIR, F.E. Fire Extinguisher VGDF Vertical Grain Douglas Fir m ,y 2 interior wall letter w v ' Foothill Blvd 4. All development within this tract cannot be finaled for occupancy until all infrastructure Gar. Di sp. Garbage Disposer Wd . Wood INTERIOR ELEV. D---- (elev. key) ' G.I. Ga1vanited Iron w/ wi th REF. ',accessary to service is in place and accepted by tho Ciry. Gyp Bd. Gypsum Board W.H. Water Heater � o Arrow Hwy 6. Access to Baseline Road is to be prohibited, and access to Crescent Drive is to be limited. ' Hdr. Header P.Ra.^+ o, A%R L GA r%PL> C _ m m a F. D' `'�� P�''"a' a • > 7< Prior to developmerit, wven•fire hydrants are required. Iiydrants are to be installed at 300 scale daft :0 a 0 > a a foot intervals as shown on plans and one in tiro traffic circle. Also in the traffic circle, a � TO SCA. r 11j �o ROOM REFERENCE 05 +--- room number m so ..m a t P.I.V. and siamese for the sprinkler system flint Is required for the recreation center. r > ''� 3 v m drawn checked > - -. • a x 5 m W w AL 8. Developer is required to furnish the Fire District with underground utility plan showing a �'1G combined flow of 2500 GPM at 20 FSI front any 2 hydrants. San Bernardino Freeway 1-10 project no. shoot no 0 REVISION REFERENCE revision number ' A*- l 4 rid numbe or GRID LINE REFERENCE Atter This drawing, as an instrument of service, is the properly of the architects and may not be reproduced without their permission and unless the reproduction carnes their name. All designs and other information n/ti shown on this drawing are for use on the specified 00 4 -t-- shear panel number (key end) . • �� project only and span not be used otherwise without SHEAR PANEL ( y to I written permission of the architects. M � ri Written dimer*ions shall have precedence over scaled dimensions, Contractors shall verify and be respon- sible for all dimensions and conditions on the jot# and the architects shall tie informed of any variatidnis from the dimensions and conditions shown on the drawing. Shop drawings shall be submitted to the architects for approval before proceeding with fabri- cation. i - 4