Loading...
HomeMy WebLinkAbout2225-1GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND THE CITY OF FONTANA PUBLIC WORKS DEPARTMENT STAN - ADR SPECIFICATIONS IN EFFECT AS OF THE APPROVAL DATE OF THESE PLANS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO THE START OF ANY WORK WITHIN THE CITY LIMITS. 3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE LOCATION AND GRADES AS SHOWN ON THESE PLANS. SLOPES LESS THAN 0.40% SLOPE SHALL BE STAKED 12.5' ON CENTER. 4. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THESE PLANS AND LOCATED WITHIN AREAS TO BE IMPROVED, AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS. 5. EXISTING UTILITIES SHALL BE MAINTAINED IN PLACE BY THE CONTRACTOR, UNLESS OTHERWISE NOTED. 6. ALL STATIONING IS ALONG SEWER CENTERLINE. 7. ALL INSPECTIONS ARE TO BE CALLED FOR THROUGH THE CITY OF FONTANA AT LEAST "24" HOURS PRIOR TO THE START OF ANY WORK. (714) 350-7610 8. ALL PROPOSED CONNECTIONS TO EXISTING ELEVATIONS OF EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF ANY WORK. THE ENGINEER SHALL BE NOTIFIED OF ANY DEVIATIONS IMMEDIATELY 9. ALL UTILITIES SHALL BE CONSTRUCTED, TESTED, APPROVED AND BACKFILLED TO THE SATISFACTION OF AND CERTIFIED TO BY THE SOILS ENGINEER PRIOR TO ANY PAVING. 10. THE ENGINEER SHALL CHECK-OUT ORIGINAL PLANS AND TRANSFER "AS -BUILT" PLAN BEFORE CITY ACCEPTANCE OF THE IMPROVEMENTS. II. EXISTING TREES SHALL BE REMOVED ONLY IF SO DESIGNATED. THOSE TREES NOT INTERFERING WITH CONSTRUCTION SHALL BE PROTECTED IN PLACE. 12. ALL MANHOLE FRAMES AND COVERS ARE TO BE CONSTRUCTED BY THE SEWER CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON COMPLETION OF PAVING, THE PAVING CONTRACTOR SHALL RAISE SAME TO FINISH GRADE. 13. CONTRACTOR SHALL PROVIDE RECORD DRAWINGS FOR CITY RECORDS PREPARED BY REGISTERED CIVIL ENGINEER IN THE STATE OF CALIFORNIA. 14. THE CONTRACTOR SHALL PROVIDE TO THE CITY OF FONTANA TRAFFIC ENGINEERING DIVISION, PHONE (714) 350-7610, A DETAILED TRAFFIC CONTROL PLAN DESIGNED IN ACCORDANCE WITH CALTRANS TRAFFIC MANUAL, CHAPTER 5, MANUAL OF TRAFFIC CONTROLS, FOR CONSTRUCTION AND MAINTENANCE WORK ZONES, LATEST EDITION. THE PLAN SHALL BE REVIEWED AND ACCEPTED BY THE CITY TRAFFIC ENGINEER PRIOR TO THE ISSUANCE OF THE CONSTRUCTION PERMIT. APPROVAL MAY INVOLVE NOTIFICATION OF PUBLIC, PUBLIC AGENCIES, NEWS SERVICES, AND AFFECTED ADJACENT LAND OWNERS, A CLOSURE CONFLICT DISCLAIMER AND HAVING PLANS APPROVED BY ANY AFFECTED JURISDICTION. NOTICE TO CONTRACTOR THE EXISTANCE AND APPROXIMATE LOCATION OF UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE DETERMINED BY A SEARCH OF THE AVAILABLE PUBLIC RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UNDERGROUND UTILITIES OR STRUCTURES EXCEPT AS SHOWN ON THIS MAP. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. THE FOLLOWING COMPANIES HAVE AN INTEREST IN THE EXISTING FACILITIES WITHIN THE LIMITS OF THE PROJECT: CITY OF FONTANA PACIFIC BELL ENGINEERING SERVICE DEPT. 3073 ADAMS ST. RM 120 8353 SIERRA AVENUE RIVERSIDE, CA 92509 FONTANA, CA 92335 (909) 359-2524 (909) 350-7610 SOUTHERN CALIFORNIA EDISON SOUTHERN CALIFORNIA GAS CO. 300 N. PEPPER AVENUE 16231 VALLEY BOULEVARD P.O. BOX 788 FONTANA, CA 92335 RIALTO, CA 92376 (909) 829-4935 (909) 820-5483 FONTANA WATER CO. COMCAST 8440 NUEVO AVENUE 8561 NUEVO AVENUE FONTANA, CA 92335 FONTANA, CA 92335 (909) 822-2201 (909) 350-2344 FONTANA UNION WATER CO. 16779 SPRING STREET FONTANA, CA 92335 (909) 822-2209 UNDERGROUND ALERT 1-800-422-4133 UNDERGROUND SERVICE ALERT call: TOLL FREE 1-800-422-4133 TWO WORKING DAYS BEFORE YOU DIG L RAIL rL I _k _91�� 41, 111 11ft[q k'q Amaki a I i All all z' u flllE3 1 ■ , t ■4 1al ;M i / NqnA GENERAL SEWER NOTES I. ALL EXCAVATIONS WITHIN THE CITY OF FONTANA RIGHT-OF-WAY REQUIRES AN EXCAVATION PERMIT FROM THE PUBLIC WORKS DEPARTMENT. 2. UNDERGROUND SERVICE ALERT SHALL BE NOTIFIED 2 WORKING DAYS PRIOR TO START OF WORK 1-800-422-4133. 3. ALL EXCAVATION SHALL BE MADE, PROTECTED, AND SUPPORTED AS REQUIRED FOR SAFETY AND IN THE MANNER SET FORTH IN THE OPERATIONS RULES, ORDERS, AND REGULATIONS PRESCRIBED BY THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY. 4. COMPACTION OF BACKFILL SHALL VERIFIED BY A SOILS ENGINEER AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS PRIOR TO THE PLACING OF THE PERMANENT PAVEMENT. 5. PERMANENT PAVEMENT SHALL BE REPLACED WITHIN 5 DAYS OF EXCAVATION. A MINIMUM 2 INCH THICKNESS OF TEMPORARY ASPHALT PAVING SHALL BE PLACED WITHIN THE TRENCH AREA UNTIL PERMANENT REPAIR IS COMPLETE. THE TEMPORARY PAVING SHALL BE PLACED AND COMPACTED IN SUCH A MANNER AS TO PROVIDE A SAFE AND SMOOTH TRAVELED SURFACE. PERMITTEE SHALL MAINTAIN THE TEMPORARY PAVEMENT IN A SAFE AND SMOOTH CONDITION UNTIL PERMANENT PAVING IS IN PLACE. 6. PRIOR TO PLACEMENT OF PERMANENT PAVING, EXISTING PAVEMENT SHALL BE SAWCUT TO A NEAT STRAIGHT LINE. PAVEMENT CRACKED ADJACENT TO THE TRENCH SHALL BE SAWCUT AND REMOVED. 7. ALL EDGES OF EXISTING PAVEMENT BEING JOINED AND SURFACE BEING OVER- LAID SHALL RECEIVE A TACK COAT OF ASPHALT EMULSION. 8. TRENCHES OF 300 FEET OR MORE TO BE PAVED WITH A SELF PROPELLED PAVING MACHINE. 9. ANY STREET PAVED OR RESURFACED IN THE PREVIOUS 36 MONTHS WHERE THE TRENCH EXTENDS FROM THE CURB MORE THAN 7 FEET OR IS IN A TRAVELED LANE, WILL REQUIRE AN OVERLAY 25 FEET IN BOTH DIRECTIONS FROM THE CENTERLINE OF TRENCH. OVERLAYS SHALL BE PAVED WITH A SELF-PROPELLED PAVING MACHINE. 10. PAVEMENT SECT I ON FOR VALLEY I S 6 ' AC OVER 8 1/2" A B. TH I S TH I CKNESS IS FOR BID PURPOSES ONLY, ACTUAL THICKNESS TO BE DETERMINED IN FIELD. (NOTE: FOR BID PURPOSES ASSUMED T1=10.5 AND R=50) II. IF TRENCH FAILURE SHOULD OCCUR, THE PERMITTEE WILL BE NOTIFIED OF SUCH DEFICIENCIES. TRENCH FAILURES SHALL BE REMEDIED, REMOVED, AND REPLACED AT CONTRACTOR'S SOLE EXPENSE AND TO THE SATISFACTION OF THE CITY ENGINEER. 12. BEDDING MATERIAL SHALL BE SAND, GRAVEL, CRUSHED AGGREGATE, OR NATIVE FREE -DRAINING GRANULAR MATERIAL HAVING A SAND EQUIVALENT OF NOT LESS THAN 30, AND SHALL HAVE A PERCENTAGE COMPOSITION BY WEIGHT WHICH CONFORMS TO THE FOLLOWING GRADING: SIEVE SIZES PERCENTAGE PASSING SIEVES 2-2/1 ..........................................90-100 N0. 4 ..........................................35-100 13. INTERUPTION OR DIVERSION OF SEWAGE FLOWS TO FACILITATE MANHOLE CONSTRUCTION OR MODIFICATION MUST BE APPROVED BY THE ENGINEER. 14. EXISTING PAVEMENT ACROSS VALLEY BOULEVARD (OLD ROUTE 66) IS UNDERLAID BY CONCRETE. EXACT LOCATION OF CONCRETE PAVEMENT TO BE DETERMINED IN FIELD. ENGINEER'S STATEMENT THE PRIVATE ENGINEER SIGNING THESE PLANS IS RESPONSIBLE FOR ASSURING THE ACCURACY AND ACCEPTANCE OF THE WORK HEREON. IN THE EVENT OF DISCREPANCIES ARISING DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE CITY. BASIS OF BEARINGS THE BEARING OF N 89028'58" E AS SHOWN FOR THE CENTERLINE OF VALLEY BOULEVARD ON PARCEL MAP N0. 12433, AS RECORDED IN BOOK 165, PAGES 35 AND 36 OF PARCEL MAPS, RECORDS OF THE COUNTY OF SAN BERNARDINO, STATE Of CALIFORNIA. BENCH MARK RAILROAD SPIKE IN POWER POLE # 62796 NORTH WEST CORNER INTERSECTION OF MARYGOLD AND MANGO, ELEV. 1140.95 5.6' MIN. MAINTAIN 2.5' MINIMUM CLEARANCE EXISTING 12" V.C.P. PROTECT IN PLACE PROPOSED V.C.P. SEWER 12n LH IIN. ADT -AVERAGE DAILY TRAFFIC VICINITY MAP N.T.S. 13' OR 22' (SEE PLAN) REPLACE A.C. PAVEMENT PER CITY OF FONTANA STANDARD TRENCH REPAIR, STD. DETAIL 131, SEE GENERAL SEWER NOTE 10. 12" 15' EXIST. CONC. PAVING 13' *= IMIN.1 6 's 1 7 NEW ABANDONED P.C.C. ROADWAY BELOW EXIST. PAVEMENT _ REMOVE EXIST. �ffI r � SHOR i NG IS CONCRETE PAVING LfL' MANDATORY - - PER CAL OSHA'S 71 SAWCUT EXIST. CONCRETE APPR VAL_ PAVING AT 6" BEYOND TRENCH I ?TDCH LOCATION STA. 37+30.00 TO STA. 40+40.00 T� ROSEMARY ui a. w a MARYGOLD 0 0 P I PE BEDD I NG PER C I TY OF FONTANA 0 c� z w a o w �- TELEPHONE wa 0- TO BARREL. a w SANITARY SEWER CONSTRUCTION. 2" C= CLEARANCE a a TO BELL OR COLLAR. Cm wCL y - w ADT=25 000 z a ADT=26,000 - "' ADT=37,000 w VALLEY BLVD. 0 0 PER CITY OF FONTANA STD. 101. 40 a 6 REMOVE AND RECONSTRUCT CONCRETE SIDEWALK PER 280 S.F. SITE U w „ INSTALL 18" VCP SEWER. 485.7 L.F. O8 INSTALL 15" VCP SEWER. H L.F. O9 INSTALL 12" VCP SEWER. 192 L.F. v a BRICK a MORTAR PLUG 15" PIPE I EA. it SAWCUT EXISTING PAVEMENT. 9,652 L.F. 10 FWY ADT -AVERAGE DAILY TRAFFIC VICINITY MAP N.T.S. 13' OR 22' (SEE PLAN) REPLACE A.C. PAVEMENT PER CITY OF FONTANA STANDARD TRENCH REPAIR, STD. DETAIL 131, SEE GENERAL SEWER NOTE 10. 12" 15' EXIST. CONC. PAVING 13' *= IMIN.1 6 's 1 7 NEW ABANDONED P.C.C. ROADWAY BELOW EXIST. PAVEMENT _ REMOVE EXIST. �ffI r � SHOR i NG IS CONCRETE PAVING LfL' MANDATORY - - PER CAL OSHA'S 71 SAWCUT EXIST. CONCRETE APPR VAL_ PAVING AT 6" BEYOND TRENCH I ?TDCH LOCATION STA. 37+30.00 TO STA. 40+40.00 T� TRENCH DETAIL SCALE I' = 3' LEGEND P.C. SAN SEWER .09\II��II P I PE BEDD I NG PER C I TY OF FONTANA 6" MINIMUM CLEARANCE TELEPHONE STANDARD SPECIAL PROVISIONS FOR TO BARREL. 112" MAX.) MIN=O.D.+12" SANITARY SEWER CONSTRUCTION. 2" MINIMUM CLEARANCE MAX=O.D.+24" (SEE GENERAL SEWER NOTE No. 11) TO BELL OR COLLAR. (6'-0" AT MANHOLES) STREET LIGHT TRENCH DETAIL SCALE I' = 3' LEGEND P.C. SAN SEWER -------5------- WATERLINE -------W------- GAS LINE -------G------- TELEPHONE -------T------- POWER POLE ♦- GATE VALVE � HYDRANT --� SEWER SERVICE -OS WATER SERVICE -� GAS SERVICE RT. TREE LT. STREET LIGHT y - RIGHT -OF -WAY ---- R/W CENTERLINE -- i PROPERTY LINE R LIMITS OF EXCAVATION ABBREVIATIONS PLASTIC CONDUIT P.C. WATER METER W.M ASPHALTIC CONCRETE A.C. REINFORCED CONCRETE BOX R.C.B. STORM DRAIN S.D. MANHOLE M.H. POWER POLE P.P. WATER VALVE W.V CURB a GUTTER C.a G. DRIVE DR. RIGHT RT. LEFT LT. CONSTRUCTION NOTES & QUANTITY ESTIMATE ITEM QUANTITY UNIT OI INSTALL 21" VCP SEWER 3,990.5 L.F. O2 INSTALL STD. PRECAST MANHOLE PER CITY OF FONTANA STD. DETAIL No. 112. 14 EA. REMOVE PAVEMENT NECESSARY TO INSTALL SEWER. O3 SEE NOTE 3 OF THE GENERAL SEWER NOTES. 28,776 S.F. O REPLACE AC PAVEMENT WITH 6" AC OVER 8 1/Z A B SEE NOTES 5 THROUGH 10 OF THE GENERAL SEWER A.C. 11036 TONS NOTES. A.B. 755 C.Y. REMOVE AND REPLACE 8" CURB AND GUTTER PER O5 PER CITY OF FONTANA STD. 101. 40 L.F. 6 REMOVE AND RECONSTRUCT CONCRETE SIDEWALK PER 280 S.F. CITY OF FONTANA STD. 102-B. O7 INSTALL 18" VCP SEWER. 485.7 L.F. O8 INSTALL 15" VCP SEWER. 218 L.F. O9 INSTALL 12" VCP SEWER. 192 L.F. 10 BRICK a MORTAR PLUG 15" PIPE I EA. it SAWCUT EXISTING PAVEMENT. 9,652 L.F. 12 SAWCUT EXISTING CONCRETE CURB OR WALK. 48 L.F. 13 SAWCUT EXISTING CONCRETE PAVING. 850 L.F. 14 REMOVE EXISTING CONCRETE PAVING. 1,740 L.F. A � UILTS DANA S. HALLADAT DATE