Loading...
HomeMy WebLinkAbout1449C-1TO LA. 1 _ i Uj Q FWY. TO �- COLTON a 0 Z V NORTH NO SCALE VICINITY MAP 3 SLOVER AV E. _ �- INDEX MAP SCALE I"=800' DESCRIPTION Title Sheet Typical Cross Section Mulberry Avenue Striping and Channelization _ I SHEET NO. 1 j 2 3-7 8-9 JURUPA AVE. j .,q�'`��rY'� No. 27674 rxp. 3-31-10 GENERAL NOTES ' 1. The construction of all public improvements shall conform to these plans and to the requirements of the City Standard Specifications, Public Works Department, City of" Fontana. Refer to definitions and terms in City Standard Specifications. Mir R I Ir 2. Excavation and Construction Permits shall be obtained from Fontana Public Works Department prior to start of any work within the city limits. 3. The Contractor shall obtain a permit from the San Bernardino County Road 0() Depart- ment for work within the County right-of-way. U)� 4. The Contractor shall obtain a permit from the San Bernardino County Flood Control r District for work within their easements. N 5. Stationing refers to the centerlines of street except where otherwise noted. 0 6. Pavement sections shown are minimum and subject to revision and approval of the City 41 M L.E3F=RRY ^VEN 6 as required by soils test taken after completion of rough grading. 7. All underground work shall be completed prior to paving of streets. 8. Locations of Public Utilities shown have been determined from available information. However, it shall be the responsibility of the Contractor to determine the true locaFONTANA GATEWAY SPECIFIC PLAN AREA- t tion and elevation in the field of any existing utilities and to exercise proper pre- cautions to avoid injury or damage thereto. Contractor shall contact underground service alert for utility location before excavation at 1-800-422-4133. 9. All manhole and cleanout frames and covers shall be constructed 6 inches below CITY 0 F FONTANA finished grade by sewer contractor and shall be raised to grade by paving contractor after completion of paving. 10. All valve cans and covers shall be constructed 6 inches below finished grade by water-' contractor and shall be raised to grade by paving contractor after completion of paving. COUNTY OF SAN BERNARDINO 11. Refer to City of Fontana, underground utility location Standard Detail 129. 12. The Contractor(s) shall coordinate construction with all utilities and other improve j ments including, but not limited to, gas, telephone, electrical, lighting, television cable, landscaping, landscaping irrigation, domestic water, reclaimed water, sewer.. CONSTRUCTION NOTES AND UANTITY ESTIMATES storm drainage, flood control systems, etc. { P �� 1° ISA A 13. As -built drawings shall be provided by the Contractor to the City, of Fontana. NUMBER ITEM QUANTITY UNIT QUANTIT UNIT 14. Type, location and width of driveway approach aprons will be determined at the time O1 Construct 3" AC over 12" compacted SF SF of construction and shall conform with the City of Fontana Standard Details. native soil. TONS TONS �� �� �� 15. Contractor is instructed to refer to these Plans and the Specifications, and where i O2 Construct 5-1/211 AC 12 compacted �; X08 SF SF 2 there is or may be a conflict shall immediately report said conflict or possible conflict native soil. t°l�. TONS 2��i,4 -TO NS to the owners representative. O3 Construct concrete curb and gutter 16. Sterilant required under all A.C. pavement. (8" C. F. per City of Fontana Standard Detail 101) . 3,320 LF s Z(o LF 17. All exposed concrete surfaces shall conform in rade, color and finish to all adjoining p g g curbs and sidewalks. O Construct concrete curb and gutter 18. No concrete 'shall be laced until the forms and reinforcingsteel has been laced,! (1" C.F. transition to 8" C.F. per r . i inspected and approved. P j City of Fontana Standard Detail 101) . LF LF 19. The walls and faces of all excavations greater than five (5) feet in depth shall bel O5 Construct concrete curb only (8" C. F. per City of Fontana Standard effectively guarded by a shoring system, sloping of the ground or other equivalent' Detail 101) . LF - LF means. . Trenches less than five (5) feet in depth shall also be guarded when exam-' ination indicates hazardous ground movement may be expected. OConstruct standard cross gutter and 20. The Contractor(s) shall obtain a permit to perform excavation or trench work as spandrel per City of Fontana Standard ��� described in Note .19 above from California State Division of Industrial Safety.. See_; Detail 104. SF SF Standard Specifications for Public Works Construction Section 306-1.1.6. O7 Construct AC overlay. 12I SF '-' S1= L 'TONS 21. No trench backfill shall take place without prior approval of the City's inspector. TONS 8 22. Protective measures shall be taken by the Contractor so as not to cause any mud, silt'r Remove existing curb and gutter. LF LF O or debris to be deposited onto public or adjacent property at all times during cons-, O9 Adjust manhole cover to grade per truction. Any mud or debris on public property shall be removed immediately: Dust, shall be controlled by watering or other approved method throughout the grading and City of Fontana Standard Detail 109. 17 EA - �A construction operations. 10 Saw cut O existing AC pavement. 44-10 LF 2 814- LF 23. The Contractor(s) shall coordinate construction with all utilities and other improve �� I� 4 221 ments including, but not limited to, gas, telephone, electrical, lighting, television 11 Remove existing AC pavement. SF a 5r ` cable, landscaping, landscaping irrigation, domestic water, reclaimed water, sewer, 12 Construct commercial driveway approach storm drainage, flood control systems, etc. 48 -hours prior to excavation near their { to meet field conditions per City of facilities, notify: I Fontana Standard Detail 102A. ��� SF 3� 9 �, 5F City of Fontana San Bernardino County Flood Control O13 Construct commercial driveway approach 8353 Sierra Avenue 825 East Third Street Fontana, California 92335 San Bernardino, California 92408 to meet field conditions per City of Telephone (714) 350-7610 Telephone (714) 383-1665 Fontana Standard Detail 102C SF S1= So. Calif. Gas Company Pacific Telephone 8 Telegraph Company O14 Power pole relocation by other. t2- EA 14 EA 2 1981 W. Lugonia Avenue 3939 Coronado Street . Redlands, California 92374 Anaheim, California 92807 15 Fire O hydrant relocation by others. EA EA Telephone ( 714) 884-9411 Telephone ( 714) 999-5514 Southern California Edison Company Underground Service Alert 16 Chain link fence relocation. LF L 300 N. Pepper Avenue Telephone (800) 422-4133 Rialto, California 92376 Group W Cable 17 . { 1�Telephone 8561 Nuevo Avenue Metal fence relocation LF F o (714) 820-5598 - Underground Fontana, California 92335 ( 714) 875-5100 - Transmission Telephone ( 714) 350-2344 _ (213) 637-1233 -Pipelines, or Fontana Water Company 18 Fire protection system controls to be relocated. - EA -' EA_ (800) 422-4133. 16803 Spring Street _ O19 Construct catch basin structure per detail. EA EA General Telephone Company Fontana, California 92335 p 245 N. Mountain View Avenue (714) 822-2201 Pomona, California 91766 20 Install 24" reinforced concrete pipe Telephone ( 213) 357-2257 or 1750D per City of Fontana Standards and(800) 422-4133 Specif ications . ROAD NO. 57 Z Z 50 LIMITS 106-110