HomeMy WebLinkAbout2333-W-1GENERAL NOTES 1. THE ENTIRE WATER SYSTEM SHALL CONFORM TO THE SPECIFICATIONS AND REQUIREMENTS OF THE CITY OF FONTANA. 2. ALL WATER MAINS SHALL BE INSTALLED WITH 42" MINIMUM COVER EXCEPT WHERE NOTED. 3. THE MINIMUM AND MAXIMUM STATIC WATER PRESSURE WITHIN THIS SYSTEM IS --a9. P.S.I. AND -j-t4 P.S.I. 4. FIRE HYDRANT COLOR AND LOCATION SHALL CONFORM TO CENTRAL VALLEY FIRE PROTECTION STANDARDS AND SPECIFICATIONS. 5. WATER CONTRACTOR SHALL ADJUST GATE VALVE COVERS TO GRADE AFTER COMPLETION OF PAVING. 6. WATER LINES SHALL BE CONSTRUCTED USING 10 GAUGE CML/CMC WELDED STEEL PIPE (WSP) AND FITTINGS UNLESS SPECIFIED OTHERWISE ON CONSTRUCTION DRAWINGS. 7. SAND BEDDING AND SAND BACKFILL IN PIPE ZONE IS REQUIRED UNLESS NATIVE MATERIAL IS SUITABLE AS DETERMINED BY THE CITY. 8. CONTRACTOR IS RESPONSIBLE FOR SECURING FROM THE CITY COPIES OF THE STANDARD SPECIFICATIONS FOR CORRECT INSTALLATIONS OF THE PROPOSED WATER SYSTEM. 9. WATER METERS TO BE BADGER MODEL 70 (FURNISHED AND INSTALLED BY CONTRACTOR). 10. CONTRACTOR SHALL INSTALL PRESSURE REGULATING VALVES FOR EACH SERVICE CONNECTION. 11. SEPARATION BETWEEN MAINS AND SANITARY SEWER LINES SHALL CONFORM TO THE STATE OF CALIFORNIA ENVIRONMENTAL HEALTH CODE, TITLE 22, 64630-C. 12. PRIOR TO THE ACTIVATION OF ANY NEWLY CONSTRUCTED WATER LINE, TESTING AND DISINFECTION SHALL BE PERFORMED TO COMPLY WITH CITY STANDARDS. 13. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR INDIRECTLY FROM HIS OPERATION, WHETHER OR NOT SUCH FACILITIES ARE SHOWN ON THESE PLANS. 14. CONTRACTOR SHALL OBTAIN A PERMIT FROM THE CITY OF FONTANA PRIOR TO ANY CONSTRUCTION WITHIN DEDICATED STREET RIGHT-OF-WAY. 15. ANY CHANGES IN WATER LINE DEPTH OR CHANGES CONCERNING CONSTRUCTION SHALL BE REPORTED AND APPROVED BY THE CITY OF FONTANA. 16. APPROVAL OF THESE DRAWINGS BY THE CITY OF FONTANA DOES NOT CONSTITUTE A REPRESENTATION OF THE ACCURACY OR THE EXISTENCE OF ANY UNDERGROUND FACILITY. 17. LANDSCAPE SYSTEMS SHALL HAVE AN APPROVED DOUBLE CHECK ASSEMBLY INSTALLED AS A MINIMUM BACKFLOW PROTECTION REQUIREMENT. 18. AT LEAST 10 DAYS IN ADVANCE OR A MINIMUM OF 1,000 FEET AHEAD OF TRENCHING, CONTRACTOR SHALL EXCAVATE, EXPOSE AND DETERMINE ("POTHOLE") THE EXACT LOCATION AND DEPTH OF EACH AND EVERY POTENTIAL INTERFERENCE AND CONNECTION, INCLUDING, BUT NOT LIMITED T0, ALL FACILITIES SHOWN SPECIFICALLY (DEPTH AND LOCATION) ON THESE DRAWINGS, OR WHICH HAVE BEEN MARKED BY THEIR RESPECTIVE OWNERS. CHANGES OR DELAYS CAUSED BY CONTRACTOR'S FAILURE TO PERFORM "POTHOLING" AND INTERFERENCE LOCATION WORK SHALL NOT BE ELIGIBLE FOR EXTRA WORK COMPENSATION OR TIME EXTENSION. 19. DEVELOPER SHALL SUPPLY CITY OF FONTANA (CITY) FIVE SETS OF APPROVED DRAWINGS A MINIMUM OF TWO WEEKS PRIOR TO CONSTRUCTION. 20. DEVELOPER, PIPELINE CONTRACTOR, AND SUPERINTENDENT SHALL ATTEND A PRE -CONSTRUCTION MEETING WITH CITY A MINIMUM OF TWO WEEKS PRIOR TO BEGINNING CONSTRUCTION. 21. CONTRACTOR SHALL NOTIFY CITY (909-350-6685) AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. 22. CONTRACTOR SHALL FURNISH CITY WITH TWO COPIES OF THE FOLLOWING DATA AND SAID DATA SHALL BE APPROVED BY THE CITY PRIOR TO BEGINNING OF WATERLINE CONSTRUCTION. ONCE APPROVED, CONTRACTOR SHALL SUBMIT FIVE COPIES OF APPROVED DATA TO CITY FOR USE DURING CONSTRUCTION: a) ALL DATA ON TRENCH PROTECTION, CONSTRUCTION SCHEDULE, AND ENCROACHMENT AND EXCAVATION PERMITS, b) ALL DATA ON WELDED STEEL PIPE, FIRE HYDRANTS, VALVES, AIR VALVES, FITTINGS, PORTLAND CEMENT CONCRETE MATERIALS, AND ASPHALT CONCRETE PAVEMENT MATERIALS. 23. CONTRACTOR SHALL SOLID WELD ALL JOINTS THROUGHOUT A CURVE IF THE RADIUS IS LESS THAN 455' FOR 40' LENGTH OF PIPE AND LESS THAN 266' FOR 20' LENGTH OF PIPE. 24. SEPARATION BETWEEN WATER SERVICES AND SEWER LATERALS SHALL BE 10 FEET MINIMUM. 25. BEFORE MAKING ANY EXCAVATION OR TRENCH 5 FEET OR MORE IN DEPTH, CONTRACTOR SHALL SUBMIT TO CITY A DETAILED DRAWING SHOWING THE DESIGN OF SHORING, BRACING, SLOPING, OR OTHER PROVISIONS TO BE MADE FOR WORKER PROTECTION. IF SAID DRAWING DOES NOT VARY FROM REQUIREMENT OF THE OSHA CONSTRUCTION SAFETY ORDERS (CAL OSHA OR FED OSHA, WHICHEVER IS APPLICABLE AT THE TIME OF CONSTRUCTION), A STATEMENT SIGNED BY A REGISTERED CIVIL ENGINEER, ENGAGED BY CONTRACTOR AT HIS EXPENSE, SHALL BE SUBMITTED CERTIFYING THAT THE CONTRACTOR'S EXCAVATION SAFETY DRAWINGS COMPLY WITH OSHA CONSTRUCTION SAFETY ORDERS. IF SAID DRAWING VARIES FROM SAID OSHA CONSTRUCTION SAFETY ORDERS, THE DRAWING SHALL BE PREPARED AND CERTIFIED BY A REGISTERED CIVIL OR STRUCTURAL ENGINEER, AND SAID ENGINEER SHALL AFFIX HIS SEAL AND SIGNATURE TO EACH SHEET OF SAID DRAWING, CONTRACTOR SHALL NOT EXCAVATE UNTIL CITY HAS RECEIVED AND ACKNOWLEDGED THE PROPERLY CERTIFIED EXCAVATION SAFETY DRAWINGS. Underground Service Alert gEfORE roe Call: TOLL FREE �Pyv o p� 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG BENCHMARK: ELEVATION 1513.04 FWE 43 - RAILROAD SPIKE IN E.P. BY PP#1536663E S'LY SIDE OF BASELINE 220' ELY OF CHERRY AVENUE. HUNTER'S RIDGE WATER TRACT NO. 26. CUT SHEETS SHALL BE PREPARED SHOWING FLOWLINE ELEVATION. 1" x 2" HUB WITH WITNESS LATHE SHALL BE SET ALONG PIPELINE ALIGNMENT. DEVELOPER SHALL FURNISH CITY WITH FOUR SETS OF CUT SHEETS FURNISHED A MINIMUM OF TWO WORKING DAYS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOT BEGIN EXCAVATION UNTIL CITY HAS APPROVED SAID CUT SHEETS. CONSTRUCTION STAKING SHALL BE AT 50 FOOT MINIMUM INTERVALS, VALVES, FIRE HYDRANTS, AIR VALVES, BLOWOFFS, FITTINGS, AND CONNECTION LOCATIONS. CONTRACTOR SHALL USE THE CONSTRUCTION STAKES AND CUT SHEETS FOR CONSTRUCTION. CITY WILL USE THEM FOR INSPECTION OF THE WORK. CONTRACTOR SHALL PROTECT ALL SURVEY MONUMENTS AND STAKES DURING CONSTRUCTION. 27. ALL CONSTRUCTION REQUIRING CITY INSPECTION SHALL OCCUR 7:00 A.M. TO 5:00 P.M. MONDAY THROUGH FRIDAY, EXCEPT HOLIDAYS. DEVELOPER SHALL REIMBURSE CITY FOR ALL INSPECTION EXPENSES. ALL MATERIALS AND EQUIPMENT FURNISHED AND ALL WORK PERFORMED SHALL BE SUBJECT TO RIGID INSPECTION BY THE CITY. WORK PERFORMED IN THE ABSENCE OF INSPECTION MAY BE REQUIRED TO BE REMOVED AND REPLACED UNDER PROPER INSPECTION, WITH THE ENTIRE COST OF REMOVAL AND REPLACEMENT BEING BORNE BY THE CONTRACTOR, EVEN IF SUCH WORK IS NOT DEFECTIVE. WORK COVERED UP WITHOUT AUTHORITY OF THE CITY SHALL, UPON ORDER OF THE CITY, BE UNCOVERED TO THE EXTENT REQUIRED TO PERMIT INSPECTION, REPAIR, OR REPLACEMENT AND THEREAFTER SHALL BE RECOVERED. 28. AT LEAST FOUR WORKING DAYS PRIOR COMMENCING ANY EXCAVATION, CONTRACTOR ,SHALL REQUEST UNDERGROUND SERVICE ALERT (1-800-422- 4133) AND ANY AFFECTED NON-MEMBER AGENCIES TO MARK OR OTHERWISE INDICATED THE LOCATION(S) OF THEIR SUBSURFACE FACILITIES INCLUDING, BUT NOT LIMITED TO, STRUCTURES, VAULTS, MAIN CONDUCTORS OR CONDUITS, AND SERVICE CONNECTIONS. UPON LEARNING OF THE EXISTENCE OR LOCATION OF ANY UTILITY FACILITY OMITTED FROM OR SHOWN INCORRECTLY ON THESE DRAWINGS. CONTRACTOR SHALL IMMEDIATELY NOTIFY CITY AND THE ENGINEER WHO PREPARED THESE DRAWINGS. SHOULD SAID UTILITY CONFLICT WITH PROPOSED WATER FACILITIES, SAID ENGINEER SHALL SUBMIT A DRAWING SHOWING THE PROPOSED SOLUTION TO CITY FOR APPROVAL. CONTRACTOR SHALL NOT INTERRUPT OR DISTURB ANY EXISTING UTILITY FACILITY WITHOUT AUTHORIZATION FROM THE AFFECTED AGENCY. WHERE PROTECTION IS REQUIRED TO ENSURE INTEGRITY OF EXISTING UTILITY FACILITIES, CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION, 29. STREET GRADE SHALL BE BROUGHT TO WITHIN 1 FOOT OF PROPOSED FINISH GRADE PRIOR TO WATERLINE CONSTRUCTION. CONTRACTOR SHALL SHOW EXISTING ELEVATIONS OVER CENTERLINE OF PROPOSED WATERLINE ON THE CUT SHEETS. 30. DURING CONSTRUCTION OF WATERLINE, CONTRACTOR SHALL PROVIDE A PIPELINE CAP AND TEMPORARY THRUST PROTECTION FOR TESTING AND DISINFECTION AT A MINIMUM OF 5 FEET FROM CONNECTIONS TO EXISTING WATER SYSTEM AFTER NEW PIPELINE AND APPURTENANCES HAVE BEEN DISINFECTED, TESTED, AND ACCEPTED BY CITY. CONTRACTOR SHALL REMOVE PIPELINE CAP AND TEMPORARY THRUST PROTECTION AND INSTALL CONNECTION PIPING. THE CONNECTION PIPING SHALL BE SWABBED WITH A CHLORINE SOLUTION. 31. OPEN EXCAVATION WILL BE ALLOWED OVER NIGHT OUTSIDE OF PUBLIC STREET RIGHT-OF-WAY PROVIDED SITE IS SECURE. A CONSTRUCTION FENCE, ENTIRELY ENCLOSING THE SITE, WILL BE REQUIRED. 32. PIPELINES SHALL BE CONSTRUCTED SO THAT ACTUAL FLOW LINE ELEVATIONS ARE WITHIN 0.1 FOOT OF DESIGN FLOW LINE ELEVATIONS. PIPELINES, WHEN INSTALLED, SHALL HAVE CONTINUOUS UPGRADE OR DOWNGRADE, CORRESPONDING WITH DESIGN SLOPE, WITHOUT HIGH OR LOW SPOTS. PIPELINES SHALL BE CONSTRUCTED SO THAT ACTUAL PIPELINE CENTERLINES ARE WITHIN 0.1 FOOT OF DESIGN PIPELINE CENTERLINES. CONTRACTOR SHALL ASSIST CITY AS REQUIRED TO CONFIRM COMPLIANCE WITH CONSTRUCTION TOLERANCES. 33. CONTRACTOR IS ADVISED THAT ROCK OR UNACCEPTABLE TRENCH BACKFILL MATERIAL MAY BE ENCOUNTERED DURING TRENCHING OPERATIONS. WHERE SUCH MATERIAL IS ENCOUNTERED, CONTRACTOR SHALL FURNISH AND INSTALL SUITABLE BEDDING AND BACKFILL MATERIAL IN ACCORDANCE WITH STANDARD DRAWING W101. BEDDING AND BACKFILL MATERIAL SHALL BE EITHER COMMERCIAL IMPORTED MATERIAL OR SELECT NATIVE MATERIAL (SCREENED OR WASHED). ALL ROCK OR UNACCEPTABLE TRENCH BACKFILL MATERIAL SHALL BE DISCARDED AT A LEGAL DISPOSAL SITE. 34. A SOILS ENGINEER, APPROVED BY CITY, WILL TAKE COMPACTION TESTS AS NECESSARY. COMPACTION TESTS SHALL BE MADE IN THE PIPE ZONE, THE BACKFILL ABOVE THE PIPE ZONE, AND IN THE SUBGRADE, ALL AT INTERVALS SELECTED BY CITY. COMPACTION TESTS WILL BE TAKEN AS TRENCH BACKFILL PROGRESSES OR AFTER TRENCH BACKFILL HAS BEEN COMPLETED, AS DETERMINED BY CITY. CONTRACTOR SHALL PROVIDE TEST HOLES AS DIRECTED BY CITY WHERE BACKFILL HAS BEEN COMPLETED TO ALLOW COMPACTION TESTS. CONTRACTOR SHALL FURNISH ALL EQUIPMENT (INCLUDING SHORING), LABOR AND MATERIALS TO ASSIST SOILS ENGINEER IN MAKING ALL THE COMPACTION TESTS. WATER FACILITY TESTING CANNOT BEGIN UNTIL CONTRACTOR HAS COMPLETED COMPACTION EFFORTS AND CITY HAS ACCEPTED COMPACTION TEST RESULTS. DEVELOPER SHALL PAY ALL COSTS FOR COMPACTION TESTS. 35. IF MONUMENTS OR BENCHMARKS MUST BE REMOVED OR DISTURBED. TO ACCOMMODATE CONSTRUCTION, CONTRACTOR SHALL HAVE A. REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR REPLACE SAME. 36. THE DEVELOPER SHALL PROVIDE CITY WITH ONE SET OF RECORD DRAWING MYLARS. SAID DRAWINGS SHALL BE APPROVED BY CITY PRIOR TO ACCEPTANCE OF WATER FACILITIES BY CITY. 37. ALL SOUTHERN CALIFORNIA EDISON FACILITIES SHALL MAINTAIN A 10' SEPARATION BETWEEN ALL WATER APPURTENANCES SUCH AS HYDRANTS, AIR VALVES AND WATER METER BOXES. CONST. SITE BENCHMARK: EL. 1534.50 SET CHIS SQUARE ON CATCH BASIN AT THE N.W. CURB RETURN FKRIEGER MENDED FOR APPROVAL -WATER ONLY BRIDLEPATH DR. & CHERRY AVE. & STEWART, INC. 50 FT. N.E. C/L BRIDLEPATH DR. 36 FT. N.W. C/L CHERRY AVE. 1000erlooer���� R.C.E. ZZo L,.o IMPROVEMENT PLANS 142749 14274�1 & 14274�2 LEGEND /0\- FIRE HYDRANT ® - GATE VALVE A - A/V RELEASE VALVE PRIVATE ENGINEER'S NOTICE TO CONTRACTORS s IKIncV k AM !►1�lG"Wei THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS AND OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." 7-, f,, ?S ReGORD DRAIN I DATE I REVISIONS v 11 26 q PPROVAL DATE CITYAPPROVAL DATE LU m c Na 052312 R' ,12/31 4$ 1F 10�1 O 1p CA%__1f PIPE CURVE DATA PIPE SIZE >-zowf 10 FT. Xm -wCE O9�Oorr< 40 FT. W � (D > 230 Z F- Ly -J w Z Q 921 < QF- ��U)UE 2,341 (nz oO�cn L. F. Q w z L 0 Iij CONSTRUCT 8" GATE VALVE PER STD. DWG. # W109 a0 c LdU)20ofC 'in��� Q> --)pw� v)0r�I E. A. afw F- m 0 Lt_1 z CONSTRUCT 8" TEE _� O��< Z F_Z� 2 00� I E. A. Q vnU�t cn �� "JL'� _ Qc� <Q�(Y a 6 0 t LK E. A. 2r_zD_zw CONSTRUCT THRUST BLOCK PER STD. DWG. # W106, W107 WT> 00F 9 � <0I�C)co PIPE CURVE DATA PIPE SIZE MINIMUM RADIUS FOR PIPE LENGTH 10 FT. 20 FT. 40 FT. 8" 230 460 921 NOTE: BUILDER TO PROVIDE INDIVIDUAL PRESSURE REGULATOR FOR EACH LOT. (a z V IZSIT Flo~ J Q O J zI� M IU a m U �� F 2J 01 -o 01 9�. BRIDLEPATH Q DRIVE I I V SUMMIT AVENUE RANCHO CUCAMONGA w D z a w U �w z /:o z Ln G� HIGHLAND AVENUE VA Eli 12 11 fm! F3 CONSTRUCTION NOTES & QUANTITIES: ITEM DESCRIPTION QUANTITY UNIT TR. 14274-1 (PHASE 1) TR. 14274-2 (PHASE II) TR. 14274 (PHASE III) O1 CONSTRUCT 8" I.D. STEEL PIPE CML & C 2,293 2,341 606 L. F. �2 CONSTRUCT 8" GATE VALVE PER STD. DWG. # W109 6 6 1 E. A. O3 CONSTRUCT 8" TEE 3 2 - E. A. O4 CONSTRUCT 8" X 45' ELBOW 1 6 2 E. A. �5 CONSTRUCT THRUST BLOCK PER STD. DWG. # W106, W107 8 9 2 E. A. O6 CONSTRUCT 1" A/V RELEASE VALVE PER STD. DWG. # W117 1 1 - E. A. 0 CONSTRUCT 1" SERVICE LINE PER STD. DWG.# W126 74 54 49 E. A. O8 CONSTRUCT 6" FIRE HYDRANT ASSEMBLY PER STD. DWG.#112 4 4 3 E. A. O9 CONSTRUCT 8" FLANGE AND BLIND FLANGE 3 1 - E. A. 10 REMOVE PLUG AND JOIN 2 2 2 E. A. 11 CONSTRUCT 8" 11.25' ELBOW 2 - - E. A. 12 INSTALL PIPE CAP 1 1 - E. A. 13 CONSTRUCT 12" X 8" REDUCER 1 - - E. A. 14 CONSTRUCT 6" PVC (SCH 40) SLEEVE 22 - - L.F. UTILITY NOTES ELECTRICITY SOUTHERN CALIFORNIA EDISON CO. DISTRIBUTION PLANNING 7951 REDWOOD AVENUE FONTANA, CA 92336 (909) 357-6562 CONTACT: ARMANDO GONZALES GAS SOUTHERN CALIFORNIA GAS CO. DISTRIBUTION PLANNING 16231 VALLEY BOULEVARD FONTANA, CA 92335 (909) 428-8402 CONTACT: DAVID PADILLA WATER CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-6685 SAN BERNARDINO COUNTY FIRE AGENCY. FIRE PROTECTION PLANNING AND ENGINEERING DIVISION. APPROVED: BY: DATE: a moor Hali & Foreman, Inc. omrA Civil Engineering - Planning • Surveying • Public Works 13821 Newport Ave., Suite 200 • Tustin, CA 92680-7803 • 714/544-3404 PREPARED UNDER THE SUPERVISION OF: .C.E. 26229 DATE: SEWER CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-7610 OWNER /DEVELOPER METROPOLITAN DEVELOPMENT 15010 SUMMIT AVENUE FONTANA, CA 92336 (909) 899-0156 CONTACT: ROGER HATCH COMCAST CABLEVISION 1205 DUPONT STREET ONTARIO, CA 91761 (909) 988-8322 X3055 CONTACT: JACK HAYES MARKS CABLEVISION FIBER -OPTICS/ TRUNK LINK THROUGH PROJECT 4240 HALLMARK PARKWAY SAN BERNARDINO, CA 92407 (909) 880-0220 CONTACT: JOE DEARMAN GTE CALIFORNIA, INC. CA820VF 870 NORTH MOUNTAIN AVENUE UPLAND, CA 91786 (909) 931-2472 CONTACT: DANIEL TUCKER WILTEL, INC. FIBER-OPTIC TELECOMMUNICATIONS LAS VEGAS, NEVADA TO LOS ANGELES, CA UPLAND, CA 91786 P.O. BOX 21348, MD 26-3 TULSA, OK 74121 918) 588-3397 909) 947-9441 (LOCAL CONTACT) LOCAL CONTACT: JERRY KENNEDY BASIS OF BEARINGS: THE CENTERLINE OF SUMMIT AVENUE SHOWN AS N89'5845"W ON TRACT MAP NO. 13750 RECORDED IN BOOK 250, PAGES 48 THROUGH 66 OF MAPS. RECORDS OF SAN ,BERNARDINO COUNTY., �r OI't��.. CITY OF FONTANA, CALIFORNIA DRAWN BY WATER PLANS SCALE: KDL �TITLE SHEET AS SHOWN DESIGNED B SS TRACT N0. 142742 14274-1 & 14274-2 CHECKED BY GENERAL NOTES, CONSTRUCTION NOTES, INDEX MAP DATE: JOB N0. APPROVED: DR. N0. SHT. N0. 4439-000 , CITY ENGINEER,R.C.E. S 26 DATE �1� � � � OF 1 � o 0 rn cD/ N }- F=- O rn� 00 i� 0 iw