HomeMy WebLinkAbout2305-112 x 8 LEDGER (STRUCT. 1) W/4 -5/8"O HILTI KWIK BOLTS, EMBEDDED 4" EXIST. 8" TILT—UP WALL 4-6" x 6" HOLES COORDINATE THE DEPTH OF THIS WING WITH THE DEPTH OF EXISTING WING EL. = 91'-6" BASEMENT FLOOR LEVEL EL. = 89'-6" WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED ONES, & ALL DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF BOCK ENGINEERING, INC., PRIOR TO COMMENCEMENT OF ANY WORK. THIS DESIGN, DRAWING, SPECIFICATION & CALCULATION IS THE PROPERTY OF BOCK ENGINEERING, INC., & IS FOR USE ONLY ON THE SPECIFIC SITE INDICATED, & SHALL NOT BE USED ON ANY OTHER WORK OR SITE, EITHER AS A WHOLE 0 FOR APPROVAL OR IN PART. IT SHALL NOT BE ALTERED OR MODIFIED EITHER AS A WHOLE OR IN PART, EXCEPT BY AUTORIZED REV DESCRIPTION EMPLOYEES OF BOCK ENGINEERING, INC. 11Z' PLYWOOD (STRUCT. I, CDX) W/10d NAILING: 4" 0 BOUNDARIES AND EDGES AND 6" IN FIELD 2 x 8, 8 EACH 5" x 5" OPENING AT LOW POINT FOR EL. = 120'-9" TOP OF HOISTWAY ELEVATION G -G ELM PAB PAB 12-15-92 DWN ENG CHKD DATE REV DESCRIPTION EL. = 119'-1" NEW WALL SEE NOTE 22 SHEET A-4 EL. = 116'-9" TOP OF EXIST. ROOF EL. = 103'-0" EL. = 96'-3" EL. = 94'-9" EL. = 93'-3" EL. = 91'-9" EL. = 90'-4" CONTRACTOR SHALL REMOVE ANY PROJECTIONS OF EXISTING CONCRETE TYP AT ALL LOCATIONS WHERE EXISTING CONCRETE IS INTERCEPTED. .y •.y�% T.O.C. EL. 85'-10" EL. = 84'-6" •4 mq�,� IN0. . C26 9 ° Exp. • \ CE7:4- .• • •' �1 0 ig CAULK L NEW G.I. FLASHING NEW 8" CMU WALL NEW UNDERLAYMENT AS REQUIRED RUN UP WALL &UNDER FLASHING NEW SHT MTL SADDLE H UNDER FLASHING NEW FIBER CANT STRIP 4-5/870 HILTI KWIK BOLTS, EMBED. 4" DETAIL EXISTING 2 x 12 REPLACE EXIST. PLY'D AS REQ'D WITH SHEETS 4'-0" WIDE. INSTALL USING SAME NAIL'G AS EXIST TYP NEW 2 x 6 N.T.S. [ 1 PLYWOOD AS REQUIRED :ETS 4'-0" WIDE. INSTALL kME NAILING AS EXISTING HU212 .�.. „ 12 LEDGER W/4-5/8"0 HILTI KWIK BOLTS, EMBED. 4" TYPE HD2A 4x PC" 2x ST CORN[ OR Of TYP. SILL F I FIN. F LINE 2x STUD UP'^ PLAN 2-3/4'0 B 2-5/8"0 B SILL PLATE CONC. CURT WHERE OCC FINISHED Fl LINE BOTTOM OF 5/8"0 ANCI 3/4'0 ANCI MIN. COVER AnTTnm nF TYPE HD7A 3-7/8"0 BOLTS TYPE HD5A � DETAIL N.T.S. L2j HOEDOWN ANCHORS N.T.S. Lr;� r 2—#5 AT E4 END U ------ -------------_- DETAIL DAMAGE TO REBAR 8" CMU #4 0 2'-0" O.C. E.W. TYPICAL CORNER AT 8" CMU WALL N.T.S.r 3 � NOTES TYPICAL FOR ALL REBAR 4-#5 ® CORNER 1'-0" #5 ® 10" O.C. E.F. I� I 11 I !10 —0 —.—.----! — --- so W I I I I sot III I N N _I III I r- III I III I #6 @ 12" O.C. OR I #5 ® 10" O.C. I I I I W I I I I I I I• � APPROVED TYPICAL CORNER AT 12" CONCRETE WALL CITY ENGINEER R.C.E. CITY OF FONTANA PROJECT ARCHITECTURAL BARRIER REMOVAL PROJECT ELEVATOR FOR PERFORMING ARTS CENTER, 9460 SIERRA AVE., FONTANA,CA.92335 DWG TITLE ELEVATION G — G DWN ENG CHKD DATE & DETAILS EXIST. REBAR J L—Us F—Ho J11JL GRADE 60, BAR SIZE SAME AS EXIST, REBAR SECTI❑N A - A BAR SIZE NOTES: HD7A 1. HD INDICATES "SIMPSON" 1/4" 5 HOLD ANCHORS OR 1 1 /8"� 3/8' APPROVED EQUAL. ANCHOR BOLT 2. POST SHOWN ARE MIN. SIZE. SEE PLAN FOR SIZE. 3. TO PROPERLY LOCATED HOLD DOWN ANCHORS CONTRACTOR TO CHECK STRUCTURAL & ARCH. DRAWINGS FOR OPENINGS BOTTOM OF ETC. BEFORE PLACING SLAB BOLTS. 4. HOLD DOWN ANCHOR BOLTS SHALL BE SET IN PLACE BOTTOM OF PRIOR TO FOOTING INSPECTION. FT'G TYP. � DETAIL N.T.S. L2j HOEDOWN ANCHORS N.T.S. Lr;� r 2—#5 AT E4 END U ------ -------------_- DETAIL DAMAGE TO REBAR 8" CMU #4 0 2'-0" O.C. E.W. TYPICAL CORNER AT 8" CMU WALL N.T.S.r 3 � NOTES TYPICAL FOR ALL REBAR 4-#5 ® CORNER 1'-0" #5 ® 10" O.C. E.F. I� I 11 I !10 —0 —.—.----! — --- so W I I I I sot III I N N _I III I r- III I III I #6 @ 12" O.C. OR I #5 ® 10" O.C. I I I I W I I I I I I I• � APPROVED TYPICAL CORNER AT 12" CONCRETE WALL CITY ENGINEER R.C.E. CITY OF FONTANA PROJECT ARCHITECTURAL BARRIER REMOVAL PROJECT ELEVATOR FOR PERFORMING ARTS CENTER, 9460 SIERRA AVE., FONTANA,CA.92335 DWG TITLE ELEVATION G — G DWN ENG CHKD DATE & DETAILS EXIST. REBAR J L—Us F—Ho J11JL GRADE 60, BAR SIZE SAME AS EXIST, REBAR SECTI❑N A - A BAR SIZE WELD SIZE 3 3/16' 4 1/4" 5 5/16' 6 3/8' WHEN DRILLING INT❑ EXISTING CONCRETE FOR ANY PURPOSE (ANCHORS, BOLTS, DOWELS, LEDGER BOLTS, PLASTER ANCHOR PINS, ETC,), EXTREME CARE SHALL. BE EXERCISED AS TO NOT CUT INT❑, DISTURB OR DAMAGE IN ANY WAY THE EXISTING REBARS IN THE CONCRETE, USE ONLY MASONRY TYPE DRILLS, WHICH CAN NOT CUT INT❑ STEEL REBARS AND USE METAL DETECTORS, REBAR DETECTORS (PACO METERS) TO LOCATE REBARS BEFORE DRILLING, USE PILOT DRILLS TO TEST CLEARANCES, IF ANY EXISTING REBAR GETS ACCIDENTLY DAMAGED, IT SHALL BE REPAIRED PER DETAIL AND SUCH REPAIR SHALL BE INSPECTED BY DEPUTY INS T ALL CONCRETE �f i��'J. REMOVED FOR SUCH REPAIRS, AND ALL PILOT HOLES ;SH _ � � Lt ED AND REPAIRED BY EPDXY BASED PATCHING/SPACKLING COMPOUNDS,LRIOI� SURFACES SHALL BE MADE TO THE EXISTING CONCRETE OR I I ` NOT FOR'CONSTRUCTION 2" CLR (TYP) t CLIENT CITY 0-F FONTANA PERFORMING ARTS CENTER 9460 SIERRA AVENUE FONTANA, CALIFORNAI 92335 CITr uw 230,E SHEET II OF 16 N0. N0. N.T.S. 4 DAMAGED6. REBAR REPAIR N.T.S. BOCK ENGINEERING, INC. S�A�� PROJECT N0. 92035 C O N S U L T I N G E N 0 I N E E R S '�'L /'t = 1-p') FILE No. 92035-03 STRUCTURAL • ELECTRICAL , MECHANICAL owo. No. REV. S 6 4650 ARROW HIGHWAY, SUITE E-2 0 909 621-0544 MONTCLAIR, CALIFORNIA 91763 6 OF 7 DRAWINGS