HomeMy WebLinkAbout2305-164ENT LENT r uAiv _1'1 v i F-0. PROVIDE INCANDESCENT WALL MOUNTED FIXTURE WITH WIRE GUARD 100W S.P.S.T. SWITCH AND 20A 120V 3 WIRE 1 RECEPTACLE SURFACE MOUNT IN ELEVATOR PIT. VERIFY WITH ELEVATOR CONTRACTOR/SUPPLIER FOR EXACT 14 20 AMP W.P. DISCONNECT SWITCH FOR EXHAUST FAN ON THE ROOF. LOCATIONS AND OTHER REQUIREMENTS. 2 NEW RECESSED FLUORESCENT DOWNLIGHT (2) F13TT. LITHONIA #AF13TT7AR-120-HPF OR EQUAL. 3 NEW RECESSED FLUORESCENT DOWNLIGHT (2) F13TT W/EMERGENCY BATTERY PACK. LITHONIA #AFE 13TT7AR-120-HPF OR EQUAL. 4 NEW WALL MOUNTED FIXTURE HALO CAT #H2411 WITH WIRE GUARD WG11 OR EQUAL. 75W, A19, 120V LAMP. D INTERCEPT EXISTING CIRCUIT FROM THE DISCONNECTED WALL MOUNTED FIXTURE & EXTEND TO NEW WALL MOUNTED FIXTURE AS SHOWN. SEE E-3 NOTE 3. 6 FOR CONNECTION TO ELEVATOR CAR LIGHTING. VERIFY WITH ELEVATOR CONTRACTOR/SUPPLIER FOR EXACT LOCATION. 0 NEW SELF -LUMINOUS NON -ELECTRICAL EXIT SIGN. PERMEX CAT #P -160-R-12 OR EQUAL. J -BOX AT CEILING, CIRCUIT TO BE CONNECTED TO DOOR CONTROL/SECURITY SYSTEM. VERIFY WITH OWNER THE KIND OF DOOR CONTROL/ 8 SECURITY SYSTEM PREFERRED. ALSO, VERIFY WITH OWNER IF THE DOOR CONTROL/SECURITY SYSTEM ALREADY EXISTS WITHIN THE BUILDING. IF IT ALREADY EXISTS, JUST TIE THIS DOOR CONTROL WITH THE EXISTING. INTERCEPT EXISTING HVAC CIRCUIT, CONNECT & EXTEND THE NEW CONDUIT ROUTING TO EXISTING DISCONNECT SWITCH AS SHOWN. CONTRACTOR TO 9 FIND THE SHORTEST POSSIBLE ROUTE OF THE CONDUIT. USE SAME SIZE OF WIRE AND CONDUIT AS BEFORE AND THAT CONDUIT SHALL BE ADEQUATELY SUPPORTED. FOR REFERENCE SEE NOTE 2 OF FIRST FLOOR DEMOLITION PLAN, E-3 AND ARCHITECTURAL DRAWING A-3. 10 J -BOX AT CEILING TO BE CONNECTED TO GLASS 0 BREAKAGE SENSOR. SUPPLY & INSTALL GLASS BREAKAGE DETECTOR AND TIE IN TO EXISTING SECURITY ALARM SYSTEM. VERIFY EXACT LOCATION & MOUNTING HEIGHT & OTHER REQUIREMENTS W/THE OWNER BEFORE ROUGH -IN. 1 1 J -BOX ® CEILING, CIRCUIT TO BE CONNECTED TO MOTION DETECTOR. SUPPLY & INSTALL MOTION SENSOR & TIE IN TO EXISTING SECURITY ALARM SYSTEM. 0 VERIFY EXACT LOCATION & MOUNTING HEIGHT OF THE MOTION DETECTOR & OTHER REQUIREMENTS W/THE OWNER BEFORE ROUGH -IN. 12 DEVICE TO BE COORDINATED/TIED-IN IN THE EXISTING BUILDING ALARM SYSTEM. CONTRACTOR TO VERIFY. 13 TELEPHONE INSIDE THE ELEVATOR CABINET SHALL BE STANDARD LINE ESSENTIAL SERVICE POINT TO POINT RINGDOWN SYSTEM TO BE CONNECTED TO THE POLICE DISPATCH OFFICE. CONTRACTOR TO WIRE ALL TELEPHONE LINES UP TO PACTEL POC. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED ONES, & ALL DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF BOCK ENGINEERING, INC., PRIOR TO COMMENCEMENT OF ANY WORK. THIS DESIGN, DRAWING, SPECIFICATION & CALCULATION IS THE PROPERTY OF BOCK ENGINEERING, INC., & IS FOR USE 1 PLAN CHECK ELM ZM ZM 4-7-93 ONLY ON THE SPECIFIC SITE INDICATED, & SHALL NOT BE 0 FOR APPROVAL ELM MGO NA 12-15-92 USED ON ANY OTHER WORK OR SITE, EITHER AS A WHOLE OR IN PART. IT SHALL NOT BE ALTERED OR MODIFIED EITHER AS A WHOLE OR IN PART EXCEPT BY AUTORIZED EMPLOYEES OF BOCK ENGINEERING, INC. REV DESCRIPTION DWN ENG CHKD DATE REV DESCRIPTION DWN I ENG I CHKD DATE 0 0 O O O O O O O 10 ELEVATOR $ TANK ELEVATOR CONTROLI. N EW TI FROM UPSTAIR LOBBY FROM UPSTAIR LOBBY LIGI PLAN NOTES: It • n w 11— nnn CAIJI IIVV FlAl Ur-%C,J BASEMENT ELECTRICAL PLAN. PROVIDE J -BOXES AND CONNECTIONS FOR ELEVATOR'S TELEPHONE, FIREMAN'S TELEPHONE, LIFE SAFETY, SPEAKER AND EQUIPMENT INTERCOM IF REQUIRED. VERIFY WITH ELEVATOR SUPPLIER FOR REQUIREMENTS. PROVIDE TWO (2) 6"x6" CUT-OUTS. ONE AT THE TOP AND ONE AT THE BOTTOM OF MACHINE ROOM. ALSO PROVIDE THE SAME CUT-OUTS FOR ELEVATOR PIT. ELEVATOR PIT CUT-OUTS SHALL BE THE SAME ELEVATION WITH MACHINE ROOM CUT-OUTS. COORDINATE AND VERIFY WITH ELEVATOR CONTRACTOR/SUPPLIER FOR CUT-OUTS EXACT LOCATIONS. NEW DOOR WITH 3'-6" OPENING AS REQUIRED FOR ELEVATOR MACHINE ROOM. INTERCEPT EXISTING CIRCUIT AND EXTEND TO NEW LIGHTING LAY -OUT AS SHOWN. VERIFY IN THE FIELD. EXTEND EXISTING CIRCUIT TO THE OTHER HALF OF THE ROOM AND WITHIN THIS ROOM (NOT SHOWN ON DRAWING) DISCONNECT EXISTING 3 -WAY SWITCH NEAR THE DOOR AND REPLACE IT WITH SINGLE POLE SWITCH. MODIFY WIRING SO THAT THE NEW SINGLE POLE SWITCH WILL CONTROL THE TWO REMAINING 8'-(2) LAMPS FIXTURE. NEW LOCATION OF RELOCATED FIXTURE. INTERCEPT EXISTING CIRCUIT AND CONNECT THE WAY IT WAS BEFORE. VERIFY IN THE FIELD. NEW RECESSED FLUORESCENT DOWNLIGHT (2) F13TT WITH EMERGENCY BATTERY PACK. LITHONIA #AFE13TT7AR-120-HPF OR EQUAL. REFER TO ELEVATOR SUPPLIER/CONTRACTOR FOR EXACT LOCATION OF EQUIPMENT. INTERCEPT EXISTING CIRCUITS AT CEILING AND EXTEND/CONNECT TO NEW SWITCHES AS SHOWN. SEE E-3 NOTE 2. VERIFY IN THE FIELD EXACT NUMBER OF EXISTING WIRES AND CIRCUITS. NEW RECESSED FLUORESCENT DOWNLIGHT (2)F13TT LITHONIA #AF13TT7AR-120-HPF OR EQUAL. PROJECT ARCHITECTURAL BARRIER REMOVAL PROJECT ELEVATOR FOR PERFORMING ARTS CENTER, 9460 SIERRA AVE. ,FONTANA,CA.92335 DWG TITLE ELECTRICAL PLANS CLIENT CITY OF FONTANA PERFORMING ARTS CENTER 9460 SIERRA AVENUE FONTANA, CALIFORNIA 92335 NOT FOR CONSTRUCTION APPROVED CITY ENGINEER CITY DW S H E E T N 0. 23 0 5 N0. IC OF 16 CITY OF FONTANA _BOCK ENGINEERING, INC. SCALE C O N S U L T I N G E N G I N E E R S 1/ 4." = 1'- 0" ;; STRUCTURAL ELECTRICAL - MECHANICAL DWG. NO. 4650 ARROW HIGHWAY, SUITE E-2 909 621-0544 MONTCLAIR, CALIFORNIA 91763 4 OF R.C.E. PROJECT NO. 92035 FILE N0. 92035-05 REV. 4 4 DRAWINGS