HomeMy WebLinkAbout2305-13GENERAL NOTES ELECTRICAL SPECIFICATIONS OUTLET BOXES ELECTRICAL DEMOLITION NOTES JO JUNCTION BOX, ABOVE CEILING, OR AS REQUIRED TO SUIT THE APPLICATION 1. ALL APPLICABLE PORTIONS OF ALL CONTRACT DOCUMENTS FOR THIS INCREMENT SCOPE OF WORK . GALVANIZED PRESSED STEELKNOCKOUT TYPE FOR GENERAL INTERIOR WIRINGPROPER 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR DEMOLITION OF ALL EXISTING ELECTRICAL APPURTENANCES OF THIS PROJECT AND ALL ADDENDA, BULLETINS, CHANGE -ORDERS, AND/OR , SIZE FOR NUMBER OF WIRES BUT NOT LESS THAN 4 SQUARE. WATERPROOF CAST CONFLICTING WITH THE NEW INSTALLATION. a SINGLE GANG FLUSH FLOOR BOX WITH COVER OR AS NOTED CLARIFICATIONS THERETO SHALL APPLY TO THIS SECTION. IT IS THE INTENT AND PURPOSE OF THESE SPECIFICATIONS AND ACCOMPANYING BOXES FOR EXTERIOR WIRING AND IN WET OR DAMP LOCATIONS. MANUFACTURED BY 2. CONTRACTOR SHALL VISIT SITE AND DETERMINE ALL CONDITIONS AFFECTING DRAWINGS THAT THE CONTRACTOR PROVIDE THE NECESSARY MATERIALS, LABOR, WORKMANSHIP, TOOLS EQUIPMENT, TRANSPORTATION, ETC., FOR THE COMPLETE AND CROUSE HINDS OR APPLETON. 2. THE DEMOLITION SHALL INCLUDE THOSE ELECTRICAL ITEMS THAT INTERFERE WITH JQ-I JUNCTION BOX IN WALL, +12' OR AS NOTED ELECTRICAL WORK AND INCLUDE ALL COSTS IN THIS CONTRACT PRICE. PROPER INSTALLATION AND OPERATION OF THE VARIOUS ELECTRICAL SYSTEMS THE NEW CONSTRUCTION, INCLUDING ALL UNDER FLOOR AND ABOVE CEILING RACEWAYS AND WIRING NO LONGER BEING USED TELEPHONE OUTLET IN WALL, PLASTER RING, +12. OR AS NOTED, WITH SPECIFIED HEREIN. DEVICES . .4 3/4' EMPTY CONDUIT WITH PULL CORD STUB -UP TO ACCESSIBLE CEILING 3. CONTACT UTILITY COMPANIES AND PROVIDE ALL SERVICES, WORK, INSTALLATION, SPACE AND COORDINATION REQUIRED FOR THEIR USE. PAY ANY CHARGES MADE BY THEM. VISIT THE PREMISES TO BECOVE ACQUAINTED WITH THE CONDITIONS TO BE 1. SWITCHES: SPECIFICATION GRADE, QUIET TYPE, IVORY COLOR 15 AMP, 125 VOLTS. 3. ALL EXISTING LIGHTING FIXTURES, DEVICES AND BRANCH CIRCUIT WIRING AND .91 DATA OUTLET, SAME AS TELEPHONE OUTLET OR AS NOTED ENCOUNTERED. NO EXTRA PAYMENTS WILL BE ALLOWED FOR WORK WHICH IS CONDUITS IN THE RENOVATED AREA SHALL BE REMOVED UNLESS OTHERWISE 4. DO ALL WORK PER GOVERNING CODE REQUIREMENTS AND SUBMIT EVIDENCE OF NOT INCLUDED IN THIS PROPOSAL DUE TO FAILURE TO THOROUGHLY EXAMINE 2. CONVENIENCE RECEPTACLES: SPECIFICATION GRADE DUPLEX GROUNDING TYPE � NOTED. ALL EXISTING FEEDERS, COMMUNICATION SYSTEMS RISERS, ETC. THAT TELEPHONE OUTLET IN FLUSH FLOOR BOX WITH FRAME FLOOR BOX, APPROVAL. THE PREMISES. 15 AMP AT 125 VOLT, IVORY COLOR AND 3 -WIRE GROUNDING. FEED OTHER FLOORS OR AREAS SHALL BE MAINTAINED. WHERE EXISTING CIRCUITS O EXTEND (1) 3/4' (OR AS NOTED) EMPTY CONDUIT WITH PULL CORD, WHICH ARE TO REMAIN HAVE BEEN DISTURBED, MODIFY THE SYSTEM AS REQUIRED THROUGH FLOOR PENETRATION, AND 7 1/2' INTO TENANT'S ACCESSIBLE 5. OBTAIN AND PAY ALL ELECTRICAL PERMITS, INSPECTION FEES, ETC. WORK INCLUDED IN THIS SECTION 3. RESTROOM RECEPTACLES: SPECIFICATION GRADE, DUPLEX, GROUND FAULT TO MAINTAIN CONTINUITY OF THE CIRCUITS. CEILING SPACE 6. COORDINATE WORK WITH ALL OTHER TRADES AND AS REQUIRED OF FUTURE 1. LIGHTING AND POWER SYSTEMS INCLUDING CONDUIT, WIRE, FITTINGS, INTERRUPTING TYPE, 20 AMP AT 125 VOLT, IVORY COLOR. PROVIDE GFI RECEPTACLE INSTALLED WITHIN 6 FEET OF A KITCHEN SINK 4. ANY BRANCH CIRCUIT WIRING WHICH IS ALTERED IN THE EXISTING BUILDING DUE O DATA OUTLET IN FLUSH FLOOR BOX SAME AS TELEPHONE OUTLET INCREMENTS OF CONSTRUCTION. RECEPTACLES AND SWITCHES. TO SERVE AS COUNTER TOP. TO THE WORK BY THE CONTRACTOR SHALL BE MADE ELECTRICALLY CONTINUOUS. SWITCH, SINGLE POLE WHERE THE CONTINUITY OF EXISTING CIRCUITS WHICH ARE INDICATED TO BE 7. INSTALL APPROVED GROUNDING BUSHING AT EACH TERMINATION OF RIGID CONDUIT. 2. LIGHTING FIXTURES, LAMPS AND ACCESSORIES FOR AN OPERABLE LIGHTING 4. MANUFACTURED BY SIERRA, LEVITON, BRYANT, GENERAL ELECTRIC OR ARROWHART. REUSED OR ARE ESSENTIAL TO THE FUNCTIONING OF A PARTICULAR SYSTEM TO REMAIN HAS BEEN DISTURBED, NEW WIRING AND CONDUITS SHALL BE INSTALLED,3 3 -WAY SWITCH 8. INSTALL CONTINUOUS GREEN THW GROUND WIRE IN EACH NON-METALLIC CONDUIT, SYSTEM. CONCEALED IN THE CEILING (WHERE POSSIBLE), BETWEEN THE TWO LOCATIONS OF AND CONNECT TO EACH CONDUIT GROUNDING BUSHING AND EACH POLE. APPLICABLE CODES AND REGULATIONS THE REUSED OUTLETS. ffH DIMMER SWITCH, SINGLE POLE-LUTRON #NT -600 U,N.O. 9. MAKE ALL CONNECTIONS WITH APPROVED SOLDERLESS PRESSURE CONNECTORS, 1. ELECTRICAL CODE FOR THE CITY OF FONTANA DEVICE PLATES 5. THE CONTRACTOR SHALL, AT HIS OWN EXPENSE, REPAIR, REPLACE AND MAINTAIN FLUORESCENT FIXTURE TAPED FOR INSULATION EQUIVALENT TO ORIGINAL WIRE COVERING. IN SERVICE ANY UTILITIES, FACILITIES, OR SERVICES DAMAGED, BROKEN OR OTHER 2. REGULATIONS OF ALL OTHER AUTHORITIES HAVING JURISDICTION, INCLUDING 1. REQUIRED FOR ALL WIRING DEVICES, TELEPHONE OUTLETS, PLATES TO BE IVORY RENDERED INOPERATIVE DURING THE COURSE OF DEMOLITION.FLUORESCENT FIXTURE, INNER LAMP ON NIGHT LIGHT OR EMERGENCY 10. FURNISH AND INSTALL ALL LIGHTING FIXTURES, LAMPS ACCESSORIES, ETC. AS APPLICABLE PUBLICATION OF THE NEC. PLASTIC, SIERRA P" LINE, OR AS SELECTED BY THE OWNER. Q CIRCUIT OR WITH EMERGENCY BACK-UP BATTERY PACK AS NOTED ON REQUIRED. 6. THE CONTRACTOR SHALL RECOGNIZE THAT EXISTING ELECTRICAL EQUIPMENT MUST FIXTURE SCHEDULE PERMITS AND APPROVALS 2. GANG COVERS FOR GANG BOXES. BE DE -ENERGIZED TO ALLOW DEMOLITION OF EXISTING AREAS AND RECONNECTION DOWNLIGHT ON NL OR EQUIPPED WITH BATTERY PACK 11. BALLASTS SHALL BE U.L. APPROVED, HIGH POWER FACTOR, CONSTANT WATTAGE OR OF EXISTING EQUIPMENT. THE TOTAL INTERRUPTION OF SERVICE FOR MORE THAN AS NOTED ON THE FIXTURE SCHEDULE. REGULATOR TYPE, CLASS P AS APPLICABLE, AND OR THE LOWEST SOUND LEVEL AS REQUIRED BY CITY ORDINANCES TO BE OBTAINED AND PAID FOR BY THE AVERY SHORT TIME SHALL NOT BE PERMITTED. SCHEDULE SUCH WORK WITH THE 0 DOWNLIGHT RATING OBTAINABLE. CONTRACTOR. OWNER AND ACCOMPLISH THIS WORK ATA TIME SATISFACTORY TO THE OWNER. Q WALL WASHER 12. PERMANENTLY AND VISIBLY LABEL ALL COVER PLATES WITH CIRCUIT AND VOLTAGE LOCATION LIGHTING FIXTURES 7. THE OWNER SHALL HAVE THE FIRST OPTION AT RETAINING TITLE TO EXISTING CONTAINED. MATERIALS, FIXTURES, AND OTHER ITEMS. ALL OTHER MATERIAL NOT TO BE CH WALL MOUNTED LIGHTING FIXTURE OUTLET LOCATIONS ARE ONLY APPROXIMATE, SELECT EXACT LOCATIONS IN 1. FURNISH AND INSTALL UL APPROVED LIGHTING FIXTURES AT ALL LIGHTING RETAINED BY THE OWNER OR REUSED SHALL BECOME THE PROPERTY OF THE 13. PRIOR TO FINAL INSPECTION FURNISH TO THE ENGINEER A SET OF "AS BUILT" ACCORDANCE WITH SYMMETRY, PROPER USAGE, AND NOT TO INTERFERE WITH OUTLETS INDICATED ON THE DRAWINGS. CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES. EMERGENCY FIXTURE EQUIPPED WITH BATTERY PACK AS NOTED ON THE FIXTURE SCHEDULE, TRANSPARENCIES OF THE ORIGINAL DRAWINGS, CORRECTED TO SHOW ALL CHANGES OTHER TRADES UNDER DIRECTION OF ARCHITECT. IN INSTALLATION. 2. FIXTURES ARE LISTED AND DESCRIBED IN THE FIXTURE SCHEDULE ON THE 8. ALL DEMOLITION WORK SHALL BE COORDINATED WITH THE OTHER TRADES AND DRAWINGS. WITH THE OWNER. 1-_ o--1 FLUORESCENT STRIP LIGHT, SURFACE OR PENDANT MOUNT W/OUTLET BOX 14. CONDUIT RUNS ARE SHOWN FOR CIRCUITING PURPOSES ONLY, AND MAY BE VARIED, IF APPROVED IN WRITING. 3. SOCKETS: CORROSION RESISTANT METALS OF BRASS, BRONZE OR COPPER �� LIGHTING STANDARD WITH SINGLE OR DOUBLE ARM MOUNTED LUMINAIRE REPAIRS ALLOYS; PRESSED ALUMINUM SHELLS OR CONTACTS ARE NOT ACCEPTABLE. WITH POLE SUPPORT BASE 15. ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM TIME OF ACCEPTANCE AS MAY BE NEEDED AFTER INSTALLATION IS COMPLETE, BY TRADESMEN REGULARLY INCLUDING LAMPS, INSTALLATION, AND ASSOCIATED REPAIRS. BALLASTS SHALL BE 4. INSTALL LAMPS IN ALL FIXTURES. MAKE ALL ADJUSTMENTS NECESSARY TO THE �7 TRACK LIGHTING FIXTURE, CEILING MOUNTED WITH FLUSH OUTLET BOX PER MANUFACTURER'S GUARANTEE. PERFORMING THAT KIND OF WORK. LIGHTING FIXTURES AND LAMPS TO PROVIDE SATISFACTORY RESULTS. 16. BRANCH CIRCUITING IN INSULATED WALLS AND ATTICS SHALL BE DERATED PER 5. ALL RECESSED INCANDESCENT FIXTURES SHALL BE THERMALLY PROTECTED. EXIT SIGN SINGLE FACE, MOUNTED ON RECESS CEILING OUTLET BOX, ARROW INDICATES DIRECTIONAL ARROW ON EXIT SIGN. N.E.C. CODE 1990, TABLE 310-16 AND 310-17. SHOP DRAWINGS 17. MOUNT ALL BATHROOM AND SWITCHES OVER THE LAVATORIES AT +44" UNLESS PROVIDE FIVE COPIES OF CATALOG CUTS FOR EACH FIXTURE TYPE. 6. SEE "GENERAL LIGHTING FIXTURE COMMENTS" FOR ADDITIONAL INFORMATION. a EXIT SIGN DOUBLE FACE, MOUNTED ON RECESS CEILING OUTLET BOX, NOTED OTHERWISE. STRUCTURAL CONDITIONS WARRANTY I-® EXIT SIGN MOUNTED ON FLUSH WALL MOUNTED OUTLET BOX, 18. NON-METALLIC OUTLET BOXES SHALL NOT BE INSTALLED ON DIVISION WALL AND CEILING OUTLETS. PENETRATE NO STRUCTURAL ELEMENTS INCLUDING SHEAR WALLS, WITHOUT WRITTEN PROVIDE A WARRANTY FOR ALL EQUIPMENT EXCEPT LAMPS FOR A PERIOD OF ONE ( `T\ CONSENT OF ARCHITECT. 19. BOND ALL METALLIC GAS AND WATER PIPING FOR CONTINUITY YEAR AFTER COMPLETION, AND ACCEPTANCE BY THE OWNER OF THE PROJECT. ANY 100 'A' INDICATES FIXTURE TYPE, '100' INDICATES FIXTURE TOTAL WATTAGE ELECTRICAL TROUBLE DEVELOPING DURING THIS PERIOD DUE TO FAULTY WORKMANSHIP PER NEC SEC. 250-80. COORDINATION OR MANUFACTURE WILL BE COVERED UNDER THE WARRANTY AND CORRECTED AT NO COST TO THE OWNER. 20. PROVIDE GROUNDING CONDUCTOR WHENEVER FLEXIBLE CONDUIT IS USED AND: REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR WIRING, DIAGRAMS, EXACT Ac MECHANICAL EQUIPMENT CALL OUT, REFER TO MECHANICAL DRAWINGS EQUIPMENT LOCATION, AND OTHER INFORMATION REGARDING THE EXTENT OF TESTS FOR EXACT LOCATION AND REQUIREMENTS OF MECHANICAL EQUIPMENT. A. AMPERE RATING OF CIRCUIT EXCEEDS 20 AMPS, OR ELECTRICAL WORK REQUIRED BUT NOT NECESSARILY INDICATED ON ELECTRICAL B. FLEXIBLE CONDUIT RUN EXCEEDS 6 FT. DRAWINGS. TEST ALL WIRE FOR SHORTS, OPENS, GROUNDS OR OTHER DEFECTS; CORRECT ANY 1� '1' INDICATES DRAWINGS REFERENCE NOTE, ELECTRICAL SYMBOLS LIST C. IN ALL OTHER CASES, NOT GROUNDING CONDUCTOR IS REQUIRED, PROVIDED AND ALL DEFECTIVE WORK, DEMONSTRATE CONTINUOUS SATISFACTORY OPERATION OF APPROVED CONNECTORS ARE USED, AND AS APPLICABLE PER CODE. CONDUIT ALL ELECTRICAL EQUIPMENT BY RUNNING THROUGH MANUAL OPERATIONS. (As APPLICABLE) O SMOKE DETECTOR 21. OVERCURRENT PROTECTION AND DISCONNECTIONG MEANS FOR ALL MOTORS SHALL 1. GALVANIZED OR SHERARDIZED RIGID STEEL CONDUIT FOR EXPOSED CONDUIT AND al -3-s THREE SINGLE PHASE CIRCUITS TO PANEL 'A' WITH COMMON NEUTRAL BE INSTALLED TO COMPLY WITH ELECTRICAL CODE. IN DAMP LOCATION. USE GALVANIZED COUPLINGS, LOCKNUTS, BUSHINGS AND A,1&3&5 ONE THREE PHASE CIRCUIT TO PANEL 'A' NO NEUTRAL SQ SPEAKER CONNECTORS, INSTALL CONDUIT CONCEALED EXCEPT AS NOTED ON DRAWINGS. al & 3 ONE SINGLE PHASE CIRCUIT TO PANEL 'A' NO NEUTRAL 22. EXACT LOCATION OF ALL EQUIPMENT SHALL BE VERIFIED IN THE FIELD. 2. ELECTRICAL METALLIC TUBING: THIN WALL, GALVANIZED STEEL: FOR EXPOSED A,1,3,5 THREE SINGLE PHASE CIRCUITS WITH SEPARATE NEUTRALS -1 ELECTRICAL PANELBOARD 23. ALL ELECTRICAL EQUIPMENT OUTDOORS SHALL BE WEATHERPROOF. CONDUIT ABOVE GROUND NOT ENCASED IN MASONRY OR CONCRETE, EXCEPT MAIN SWITCHBOARD "MS" ADJACENT BALLOON INDICATES PANEL DESIGNATION 'A' SEE SHEET EXTERIOR EXPOSED CONDUIT. �- HOMERUN TO PANEL OR EQUIPMENT AS NOTED E-1 FOR PANEL SCHEDULE 24. THE CONTRACTOR SHALL EXAMINE ALL CONTRACT PLANS IN ORDER TO LOGICALLY CONDUIT RUN CONCEALED IN WALL OR ABOVE FINISHED CEILING LOCATE WORK IN COORDINATION WITH CONSTRUCTION SUCH AS CABINETS, BEAMS, 3. FLEXIBLE METALLIC CONDUIT: SPIRAL INTERLOCKED, GALVANIZED ALUMINUM, FOR A. CIRCUIT PROTECTORS: FUSED SWITCHES AS INDICATED. OR AS NOTED FURRING, DOOR SWINGS, DUCTS, PIPES AND CEILINGS. CONDUIT CONCEALED ABOVE GROUND NOT ENCASED IN MASONRY OR CONCRETE - CONDUIT IN OR UNDER FLOOR, SLAB OR BELOW GRADE, 3/4' MINIMUM FLOOR STANDING SWITCHGEAR, ADJACENT BALLOON INDICATES EQUIPMENT PROHIBITED IN WET OR DAMP LOCATION; SEAL-TITE OIL RESISTANT FLEXIBLE 1. FUSED SWITCHES: QUICK -MAKE, QUICK -BREAK, VISIBLE BLADE, HORSEPOWER DESIGNATION 'DBA' SEE SHEET E-1 FOR SINGLE LINE DIAGRAM AND/OR 25. CONDUIT SHALL BE CLEAN OF WATER, DEBRIS AND OTHER FOREIGN MATERIAL CONDUIT WITH PROPER FITTINGS FOR WET OR DAMP LOCATIONS. RATED, SPRING PRESSURE FUSE CLIP AND BLADE JAW INTACT, PAD LOCKABLE CONDUIT, INSTALLED EXPOSED SCHEDULE OCCURS ON. PRIOR TO PULLING CABLES. IN THE "OFF" POSITION, WITH POSITION INDICATING OPERATING HANDLES AND 4. PVC SCHEDULE 40 FOR UNDERGROUND FEEDERS. DEFEATABLE COVER INTERLOCK TO PREVENT ACCESS TO THE FUSED UNLESS EQUIPMENT GROUNDING CONDUCTOR, GREEN IN COLOR, SAME SIZE AS CIRCUIT CONDUCTORS OR AS NOTED ON DRAWINGS, I� � � 26. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECT PHASING SWITCH IS IN THE OPEN POSITION. MINIMUM INTERRUPTING CAPACITY, WITH �f�WV�� /V\A(OA TRANSFORMER, RATING AS NOTED OF THE BRANCH CIRCUITS OF THE ELECTRICAL PANEL. 5. INSTALL CONDUIT AS A COMPLETE SYSTEM, CONTINUOUS FROM OUTLET TO SPECIFIED FUSES, OF 50,000 SYMMETRICAL RMS AMPERES AT ALL VOLTAGES 0 CONDUIT TURNED DOWN OUTLET, CABINET, BOX OR FITTINGS AND SO MECHANICALLY AND ELECTRICALLY 600 VOLTS AND BELOW. CONNECTED THAT ADEQUATE ELECTRICAL CONTINUITY FROM ONE CONDUIT TO --O CONDUIT TURNED UP, LETTER 'F' INDICATES FLUSH FLOOR COUPLING, ANOTHER IS SECURED. 2. FUSES: CURRENT LIMITING TYPE, MINIMUM 100,000 SYMMETRICAL RMS CONDUIT RISER -UP ��- FUSE, RATING AS NOTED AMPERES INTERRUPTING CAPACITY, BUSSMANN, GOULD SHAWMUT OR EQUAL - CONDUIT STUBBED AND CAPPED 6. INSTALL CONDUIT AS INDICATED ON PLANS AND FIRMLY SECURED AT LEAST 6" UNLESS OTHER CLASS OR TYPE INDICATED. PROVIDE THREE SPARE FUSES --�- CONDUIT WITH SEAL -OFF FITTING �•- DISCONNECT SWITCH, RATING AS NOTED FROM ANY HOT WATER PIPE, HOT AIR DUCT, FLUE OR VENT. FOR EACH SIZE AND TYPE AND MOUNT IN A SUITABLE CABINET BEHIND HINGED DOOR WITH NAMEPLATE ENGRAVED "SPARE FUSES" . LOCATE E EXISTING CONDUIT Elj NON-FUSED DISCONNECT SWITCH, RATING AS NOTED CABINET ON A NEAR SWITCHBOARD. /VVVM FLEXIBLE CONDUIT ���� WIRE AND CABLE B. ALL SECTIONS SHALL BE EQUIPPED WITH MICARTA NAME PLATES INDICATING NOTEi CONDUIT SIZES ARE MINIMUM L-1- FUSED DISCONNECT SWITCH, RATING AS NOTED "CAUTION - INSTALL ONLY CURRENT LIMITING FUSES AS ORIGINALLY INSTALLED". l0 8 1. CONDUCTORS SHALL BE COPPER #12 AWG MINIMUM UNLESS SPECIFICALLY NOTED 1/2'c-2#12---I-�- 1/2'c-2#10 --}�- 3/4'c -2#s 400AT OTHERWISE ON DRAWINGS. 400A�,� CIRCUIT BREAKER, 400 AMP -TRIP, 400 AMP FRAME 10 8 2. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID AND #8 AWG AND LARGER PANELBOARDS ---�H-- 1/2'C-3#12 -}+I- 1/2'C-3#10 3/4'C-3#8 SHALL BE STRANDED. TYPE OF WIRE SHALL BE AS FOLLOWS: 10 s AFI CIRCUIT BREAKER WITH GROUND FAULT PROTECTION 1. PANELS SHALL BE TYPE AS INDICATED ON THE DRAWINGS AND SHALL BE FOR ---H-H--- 1/2'C -4#12 --moi- 3/4'c-4#10 --,;;T- 3/4'c-4#8 A. TYPE THW, THHN, THWN, 600 VOLT, INSULATION SHALL BE USED FOR #4 VOLTAGE AS SHOWN ON PANEL SCHEDULE, BRANCH BREAKERS, SPARES AND 10 s AWG AND SMALLER. SPACES AS SCHEDULED, CAPACITY OF MAIN BUSSES SHALL BE SHOWN ON THE -I'll I-- 3/4'C-5#12 H i l i- 3/4'C -5#10 -I -F++ ---I- 1'C -5#8 ®1 MAGNETIC STARTER, NUMERAL '1' INDICATES SIZE. DRAWINGS. B. TYPE THW OR THHN/THWN, 600 VOLT, INSULATION SHALL BE USED FOR SIZES 10 8 COMBINATION OF MAGNETIC STARTER WITH DISCONNECT SWITCH, '1' #2 AND LARGER AND FOR PANEL FEEDERS. 2. ALL PANEL BUSSING SHALL BE COPPER AND ALL BREAKERS SHALL BE BOLT-ON 3/4'C-6#12-}}}}---H 1'C -6#10 -111-I1'C -6#8 1 NUMERAL INDICATES SIZE. TYPE. PANEL SHALL BE EQUIPPED W/C.OPPER GROUND BUS. 10 8 MOTOR CONNECTION, PROVIDE SAFETY DISCONNECT C. TYPE THWN, 600 VOLT, INSULATION SHALL BE USED FOR ALL BRANCH 3/4'c-7#12VC -7#10 -1 1 1/4'C-7#8 l:L_ AS REQUIRED BY CODE, CIRCUIT CONDUCTORS INSTALLED IN CONDUIT OUTSIDE OF AIR CONDITIONED 3. BALANCE ALL CIRCUITS. ALL CONDUCTORS SHALL BE CONTINUOUS WITHOUT SPACE, EXPOSED TO WEATHER AND OTHER HOT LOCATIONS. SPLICING FROM LAST OUTLET TO THEIR TEMINALS IN CABINET. ALL CIRCUIT 10 s CONDUCTORS IN CABINET SHALL BE INSTALLED WITH SUFFICIENT AMOUNT OF H -t-- vC -8#12-I-FH--H-I�-- 1'c -8#10 H- 1 1/4'C-8#8 EXHAUST FAN CONNECTION PROVIDE SAFETY 3. ALL CONDUCTORS SHALL BE COPPER UNLESS NOTED OTHERWISE AND LENGTH TO REACH THE MOST BREAKER CONNECTION FORM ITS POINT OF DISCONNECT AS REQUIRED BY CODE, MANUFACTURED BY ANACONDA, GENERAL CABLE, GENERAL ELECTRIC, OR EQUAL. ENTRANCE. DUPLEX RECEPTACLE IN WALL +12' OR AS NOTED 120V, 15A LETTERED BALLOON 'A' INDICATES PANELBOARD 'A' OR EQUIPMENT 4. WRAP JOINTS AS NECESSARY WITH LAYERS OF SCOTCH TAPE #33. 4. PROVIDE A DIRECTORY OF CIRCUITS FOR CABINET. DIRECTORY SHALL BE DESIGNATION TYPEWRITTEN DESIGNATING ROOM OR EQUIPMENT AND CIRCUIT NUMBERS, DUPLEX RECEPTACLE IN FLUSH FLOOR BOX WITH HINGED BRASS COVER(S) 5. DO NOT USE ANY MECHANICAL DEVICE TO PULL WIRE UNLESS SPECIFICALLY DIRECTORY FRAME, LOCK, HINGES, ETC. ARE TO BE SECURED TO INSIDE OF OR AS NOTED. APPROVED BY THE ELECTRICAL ENGINEER. DOOR AND TRIM IN SUCH A MANNER THAT SCREWS, HOLES OR WILDS, ETC. TWO -GANG DUPLEX RECEPTACLE (QUADPLEX) IN WALL, +12' OR AS NOTED, 12OV, 15A. Q )f� ARE NOT VISIBLE ON THE DOOR PANEL OR TRIM. 6. IDEAL YELLOW #77 OR EQUAL PULLING COMPOUND IS THE ONLY LUBRICANT PERMITTED FOR PULLING WIRE. 5. THE WIDTH AND HEIGHT OF CABINETS SHALL BE SUFFICIENT TO PROVIDE A WIRING TWO -GANG DUPLEX RECEPTACLE (QUADPLEX) IN WALL, +12' OR AS NOTED, 120V, 20A. GUTTER AT THE TWO SIDES AND AT THE TOP AND BOTTOM OF NO LESS THAN 4" DUPLEX RECEPTACLE, 20A-12ov, (s-2❑R> +12. OR AS NOTEDB ' 7. USE PRESSURE, SOLDERLESS, CONNECTORS OR STRANDED WIRE AND 3M ADDITIONAL WIDTH OR HEIGHT SHALL BE PROVIDED. IF REQUIRED FOR MAIN OR pp �P.p)ILL SCOTCHLOK OR IDEAL WING -NUT CONNECTIONS FOR SOLID WIRE. SUB -FEEDER CABLES PASSING THROUGH TO FEED OTHER CABINETS. e-- SINGLE RECEPTACLE, 20A -120V, (5-213R) +12' ❑R AS NOTED 6. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE "D', ITE GOULD, OR SPECIAL RECEPTACLE TYPE AS DESIGNATED OR SCHEDULED, +121 WESTINGHOUSE. IG OR AS NOTED NOTEi 'IG' INDICATES 'ISOLATED GROUND' TYPE RECEPTACLE WITH ' ORANGE COLORED FACES 'WP' INDICATES 'WEATHER PRTYPE APPROVEDOF' NOT FOR CONSTRUCTION 'GFI' INDICATES RECEPTACLE SHALL HAVE INTERNAL GROUND FAULT INTERRUPTER. ALL RECEPTACLES INSTALLED WITHIN 6 FEET OF A CITY ENGINEER R.C.E. KITCHEN SINK TO SERVE COUNTER TOP SURFACES SHALL HAVE GFI PROTECTION, C (T Y DWG• SHEET 23 S N 0e 0 13 I N 06 OF CITY OF FONTANA WRITTEN SCA ED DIMENSIONS ER ONES, & ALLDIMENSIONS ONS SHALL KPRECEDENCE I/FIED ON PROJECT CLIENT BOCK ENGINEERING, INC. SCALE PROJECT NO. 92035 THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO ARCHITECTURAL BARRIER REMOVAL PROJECT ELEVATOR FOR THE IMMEDIATE ATTENTION OF BOCK ENGINEERING, INC., PRIOR TO COMMENCEMENT OF ANY WORK. PERFORMING ARTS CENTER, 9460 SIERRA AVE., FONTANA,CA.92335 CITY OF F CON 11 pDWG SULTING ENGINEERS N.T.S. FILE NO. 92035-09 THIS DESIGN, THE PROPERTY DRAWING, SPECIFICATION & CALCULATION IS OF BOCK ENGINEERING, INC., & IS FOR USE PERFORMING ARTS CENTER STRUCTURAL - ELECTRICAL - MECHANICAL DWG. NO. REV. TITLE ONLY ON THE SPECIFIC SITE INDICATED, & SHALL NOT BE 0 FOR APPROVAL ELM MGO NA 12-15-92 USED ON ANY OTHER WORK OR SITE, EITHER AS A WHOLE ELECTRICAL SPECIFICATIONS 9 460 SIERRA AVENUE G� 0 OR IN PART. IT SHALL NOT BE ALTERED OR MODIFIED EITHER AS A WHOLE OR IN PART, EXCEPT BY AUTORIZED & GENERAL NOTES FONTANA, CALIFORNIA 92335 4650 ARROW HIGHWAY, SUITE E-2 EMPLOYEES OF BOCK ENGINEERING, INC. REV DESCRIPTION DWN ENG CHKD DATE REV DESCRIPTION DWN ENG CHKD DATE 909 621-0544 MONTCLAIR, CALIFORNIA 91763 1 OF 4 DRAWINGS