HomeMy WebLinkAbout2304-1R/W
M
R/W
PHASE DIAGRAM
L
STANDARD
ARMS
4
LUMINAIRE
PED PUSH
1
.8"2
j2r3
S'4
C O N D U C
---------
N D T
USED
SIG.
LUM.
95
96
0'7
0'8
w
0
m
0
0
d-
CL
-LJ
DETAIL A
DETAIL B
CONSTRUCT WHEELCHAIR RAMP PER
STATE STANDARD PLAN NSP A88
R/W CASE 'C'
10 P i
I /I
- - -
— — I — — — — — — — — — — — — — — — — — — — — — — — — — — 2" C, 2 #6, 1 #8, 4 #10, 4 #12
Lo - J 0 - O
ITH PULLRP❑PE 1.5" C, WITH PULLROPE 1.5" C, WITH PULLR❑PE
-� — — — — — — — —T— — — — — — — — — — — — — — — — — — — —
w
ON FI
00 R/W 1
0
DEMARCATI❑N P❑INT FOR # INSTALL 3" SCHEDULE 80 PVC CONDUIT WITH 3 #2 CONDUCTORS/
TELEPHONE INTERCONNECT EDIS❑N HANDH❑LE (SERVICE POINT)
APPROX, 380' WEST OF
COORDINATE ADJUSTMENT T❑ GRADE
COMMERCE WAY.I
L
STANDARD
ARMS
LUMINAIRE
PED PUSH
BT.
SIGNAL MOUNTING
S.N.S.
WITH SCE
II
II
C O N D U C
TYPE
HT.
SIG.
LUM.
H.P.S.V.
TYPE
PHASE
U L E
VEHICLE
11
I I
T
O R
B
S
C
H E
D
15 *
AWC
CIRCUIT
4
W
MAS,MAS,SV-2-TA
SP -1 -CS
COMMERCE WAY
-30.0
5.0
2
TYPE 15
30
II
15 *
250 W
B
6
S
-
SP -1 -CS
-
3.0
6.5
3
2
17
4
5
6
A8
9
N,W
MAS,SV-2-TA
SP -2 -CS
SLOVER AVE.
0.0
01
4
26-4-80
3
40
15
250 W
3
6
W
MAS,MAS,SV-1-T
I I
COMMERCE WAY
2.5
02
5
TYPE 15
30'
3
3
1 3
3
3
N
SV -1-T
CONSTRUCTION NOTES. -
-
9.5
01
6
_117
TYPE 15
30
-
15
1
B
1 3
N
SV -1-T
SP -1 -CS
-
11.5
04
1-A
10
-
3
3
3
3
E
TV -1 -T
�- I
-
9.0
5
3
3
— — — — —
3
3
3
3
3
1.
R/W
INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE "P" CABINET,
I
SLOVER AVENUE
3
AND APPURTENANT EQUIPMENT, SEE SPECIAL PROVISIONS FOR COMPLETE LIST
07
OF EQUIPMENT, CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL I 1
08
ELECTRONIC EQUIPMENT REQUIRED, INCLUDING ❑PTICOM, TO PROVIDE THE DESIRED
02 P
2
2
2
4
4
OPERATION, I I
#14
04P
2
2
2
4
06 P
2
2
2
2
2.
INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING I I
08 P
2
2
2
2
2 1
2
4
120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V UN-
02 PPB
1
2 1
2
2
METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT
1 1
04 PPB
1
1
1
2
BREAKER, 30 A CIRCUIT LIGHTING BREAKER, PEC FOR LIGHTING IN SERVICE UTILITY
06 PPB
1
2
2
2
PORTION OF ENCLOSURE,
08 PPB
1
1
1
1
1
1
1
2
3,
INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL
PPB COMMON
1
1
1
1
1
1
1
3
DETECTOR (OPTICOM MODEL M511 OR EQUA )
SPARES
3
3
3
3
3
3
3
6
55
4.
INSTALL R73-3 SIGN ❑NS - "
MA T ARM PER STANDARD PLAN ES 6T, DETAIL U
TOTAL
16
17
26
13
19
23
28
#10
LUMINAIRE
2 1
2
2
2
2
2
2
51
CONSTRUCT WHEELCHAIR RAMPS PER CITY STD, DETAIL NO, 104A
I I
SIGNAL COMMON
1
1
1
1
1
1
1
TOTAL
1
3
3
3
3
3
3
3
61
CONSTRUCT 4" PCC SIDEWALK PER CITY STD, DETAIL NO, 105A
I
#12,
AUTOSCOPE
2
2
2
2
2
2
I
WDEO COAXIAL CABLE
1
2
1 1
2
2
2
4
F-71
INSTALL CITY FURNISHED AUT❑SCOPE CAMERA AND TERMINAL BOX PER ENGINEER'S DIRECTION.
I I
OP RCOM CABLE
1
1
2
1
1
1
1
3
CONDUIT SIZE
2.5
3
3
2.5
3
3
311
2-3
I
CONTRACTOR TO FURNISH AND INSTALL VIDE❑
DETECTION C❑AXIAL CABLE PER THE SPECIAL
PROVISIONS,
1-800-422-4133
IT'S THE LAW I CALL AT LEAST TWO
DIAL BEFORE WORKING DAYS PRIOR
YOU DIGI TO EXCAVATING
O
CA L�
UNDERGROUND ALERT
BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE
LOCATION OF UNDERGROUND UTILIIES BY CONTACTING
UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
P 0 L E S C H E D U L E
L
STANDARD
ARMS
LUMINAIRE
PED PUSH
BT.
SIGNAL MOUNTING
S.N.S.
PLACEMENT
C
TYPE
HT.
SIG.
LUM.
H.P.S.V.
TYPE
PHASE
QUAD
VEHICLE
PED.
MESSAGE
A
B
1
26-4-80
30
40
15 *
250 W
B
4
W
MAS,MAS,SV-2-TA
SP -1 -CS
COMMERCE WAY
-30.0
5.0
2
TYPE 15
30
-
15 *
250 W
B
6
S
-
SP -1 -CS
-
3.0
6.5
3
27-4-80
17
40
-
-
B
618
N,W
MAS,SV-2-TA
SP -2 -CS
SLOVER AVE.
0.0
4.0
4
26-4-80
30
40
15
250 W
B
8
W
MAS,MAS,SV-1-T
SP -1 -CS
COMMERCE WAY
2.5
4.0
5
TYPE 15
30'
-
15'
250 W
B
2
N
SV -1-T
SP -1 -CS
-
9.5
3.0
6
_117
TYPE 15
30
-
15
250 W
B
2
N
SV -1-T
SP -1 -CS
-
11.5
3.0
1-A
10
-
-
-
B
4
E
TV -1 -T
SP -1 -CS
-
9.0
3.0
—
— — —
— — — — —
Lt') M
— — — — — — L —� — —
SLOVER AVENUE
REMOVE
EXISTING SIDEWALK AND
w
LANDSC
PING AS NECESSARY AND
o
CONSTR
CT WHEELCHAIR RAMP PER
�
STATE
TANDARD PLAN NSP A88 CASE
LUMINAIRE MAST
ARM ON POLE 10 & �2 TO BE STRAIGHT
WITH
NO RISE FROM MOUNTING FLANGE.
C AS
DIRECTED BY THE ENGINEER.
I�
°-
R/W
a:
+ —
—�
—
71
_
P.P # 4169902 E
�P
+
L� +
t
'LJ'
05
I
3
8P
I
1
�3
DETAIL "B"
03)
[L "A"
I — —
—
— — —
— — — — —
Lt') M
— — — — — — L —� — —
SLOVER AVENUE
_ 4 1 — — —
3 I
ru 0 I -- - I -
-- -- -- -- - - --
Y — Gr_ — — — — — -6- — — — — --�
0
LJ
ou
H H
MTARKER F❑R HIGH PRESSURE GAS LINE � _T �
= R/W
18" RCP EX. STREET LIGHT POLE In
# 4070790 E TO BE REMOVED BY SCE
0
CL
o_
GENERAL NOTES:.
1.
2.
R/W 3.
4.
5.
6.
7,
8.
TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD
SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992)
L❑CATI❑N OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE, THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE.
HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS, PHONE UNDERGROUND SERVICE
ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING.
ALL PULLBOXES SHALL BE No, 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SH❑WN,
ALL VEHICLE HEADS SHALL BE METALLIC WITH ALL 12" LENSES, AND ONE-PIECE METALLIC LOUVERED
BACKPLATES, ALL RED INDICATIONS SHALL BE LED'S PER THE SPECIAL PR❑VISIONS, ALL
PEDESTRIAN HEADS SHALL BE METAL WITH INTEGRAL CLAMSHELL MOUNT.
C❑ORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA
EDISON COMPANY WELL IN ADVANCE OF NEED,
EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING
IS OPERATI❑NAL,
OBTAIN APPROVAL FOR EXACT EQUIPMENT L❑CATIONS PRIOR TO FINAL PLACEMENT,
RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY
CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS, MODIFY
SPRINKLER SYSTEMS IF NECESSARY,
pffilsS/pN9l
E. S�i�F Fye,
NO. 26690
P. 3�j/96
* fl9F/NG
OFE Al\EO��