Loading...
HomeMy WebLinkAbout2303-1CONDUCTOR SCHEDULE AW CIRCUIT 'L A 3 'LA S AA.L � FUTURF 01 3 3 3 3 3 6 3 3 PUSH 02 SIGNAL MOUNTING PED. S.N.S. 3 3 1 3 TYPE HT. SIG. 03 H.P.S.V. TYPE PHASE QUAD VEHICLE PED. 6 3 A 04 A 3 3 3 3 3 05 SP-1—CS 6 SANTA ANA 1 3 3 3 B 1—A 10 06 B 6 E 3 3 3 07 —11 3 3 3 3 3 15 250 W B 08 E MAS, SV -1—T SP-1—CS 8 MULBERRY 3 3 5' #14 02P 2 2 2 2 2 2 S TV— 1—T SP-1—CS 04P 2 2 2 2 4 2 30 15 06P 2—MAS, SV -1—T 2 4 2 2 08P F PPB POST 2 2 2 4 13,13 2,8 W,S 02 PPB 1 2 2 2 2 G 1—A 10 04 PPB 1 1 1 1 1 2 1 1 06 PPB H 19-4-80 30 2 1 250 W 08 PPB MAS, SV— 1—T 1 2 2 I PPB COMMON 1 1 1 1 1 2 1 1 SPARES 3 3 3 3 3 6 3 3 TOTAL 10 119 22,29 Tv— 1—T 32 60 22 13 LUMINAIRE 2 2 2 2 1 2 2 #10 SIGNAL COMMON 1 1 1 1 1 2 1 1 TOTAL 1 3 3 3 3 2 3 3 # 8 1 GFCI GROUND 1 1 #61 SERVICE 2 2 #12 1 VIDEO CAMERA 2 2 2 2 2 2 VIDEO COAXIAL CABLE 1 1 2 2 1 4 1 1 OPTICOM CABLE 1 1 2 2 4 1 1 CONDUIT SIZE 2.5" 3" 3" 3" 3" 2—Y 3" 12.5" �c CONTRACTOR TO FURNISH AND INSTALL VIDEO DETECTION COAXIAL CABLE AND CONNECTORS PER THE SPECIAL PROVISIONS. — SD FUTURF W 1-800-422-4133 IT'S THE LAW 1 CALL AT LEAST TWO DIAL BEFORE WORKING DAYS PRIOR YOU DIGI TO EXCAVATING O ZGA � � UNDERGROUND SERVICE ALERT OF SOUIHM CAUnNU BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 d - SD n 1.1 0 R/W GRADE AREA FOR PEDESTRIAN ACCESS, REPLACE LANDSCAPING AND MODIFY _ IRRIGATION SYSTEM AS DIRECTED BY THE ENGINEER. REMOVE EXISTING TREE O' R/W ... ..... C&G EXIST. CATCH BASIN U w DETAIL AN CONSTRUCT WHEELCHAIR RAMP PER CITY STANDARD 104A WITH LANDING AS SHOWN. O SEE DETAIL "A", THIS SHEET ll FOR CONSTRUCTION DETAILS INSTALL R49 SIGN ON SIGNAL POLE 5 8 0 AS DIRECTED BY THE ENGINEER w w wO — EXISTING STREET LIGHT TO BE REMOVED BY OTHERS SD— —SD —SD — —SD — 7 - - UFF6N - - - SAN BERNARDINO COUNTY bd W w w PHASE DIAGRAM FUTURF P 1 201,3 S 94 � FUTURF 4 b .P15I kl6 1 07 1 0'8 GENERAL NOTES., INSTALL R49 SIGN ON SIGNAL POLE � OO AS DIRECTED BY THE ENGINEER REMOVE 24" EUCALYPTUS TREES � 0 PP #580474H (PAC BELL) --- TELEPHONE SERVICE POINT 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE, HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No, 5 AND CONDUIT SHALL BE 2' RIGID METAL EXCEPT AS SHOWN, ALL VEHICLE HEADS SHALL BE METAL WITH ALL 12' GLASS LENSES, AND METAL ONE—PIECE LOUVERED BACKPLATES, ALL RED INDICATIONS SHALL BE LED, ALL PEDESTRIAN HEADS SHALL BE METAL WITH INTEGRAL CLAMSHELL MOUNT, 4. COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDIS❑N COMPANY WELL IN ADVANCE OF NEED, 5, EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING IS OPERATI❑NAL. 6. OBTAIN APPROVAL FOR EXACT EQUIPMENT L❑CATIONS PRIOR TO FINAL PLACEMENT, 7. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. ;, 06 01 0` I /04 30' 0 EX �T. P FT ERNE JW —/ 05 n. SCALE: 1"=20' INSTALL 1.5" CONDUIT WITH PULLROPE PER PAC. BELL REQUIREMENTS O 0 �c LUMINAIRE MAST ARM ON POLE ® TO BE STRAIGHT WITH NO RISE FROM MOUNTING FLANGE CONSTRUCT 4' PCC SIDEWALK PER CITY STANDARD NO. 105A AND AS DIRECTED BY THE ENGINEER. CONSTRUCT WHEELCHAIR RAMP •••••• ••� PER STATE STANDARD PLAN ' NSP A88, CASE "C", REPLACE LANDSCAPING AND REPAIR IRRIGATION SYSTEM AS DIRECTED SEE DETAIL "B", THIS SHEET BY THE ENGINEER. FOR CONSTRUCTION DETAILS 2"C, 2 #6, 1 #8, 4 #10, 4 #12 DETAIL " B" PP #4100290E 2 EDISON STALL HAND'HOLEH(SERVICE0P0 VC NT)CONDUIT WITH 3 #2 CONDUCTORS IRRIGATION BOX D/—WATER VALVE 1.5" C. 1 1C 1.5"C, 1 SIC W ►Wl= SD SD 3 02 i m 2^ s MULBERRY AVENUE 04 O 04 3 6 OO R/W i III I I� '1I o 8' 14' R/W C&G SEE SHEET 2 OF 3 FOR CONTINUATION OF INTERCONNECT SYSTEM. T 7 CONSTRUCTION NOTES 0 INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET, TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION, INCLUDING OPTICOM PHASE SELECTORS, TOP OF FOUNDATION SHALL BE 18' ABOVE SURROUNDING GRADE. Q INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING+ 120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V I UN—METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN SERVING UTILITY PORTION OF ENCLOSURE, Ioo �3 INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL. ® INSTALL R73-3 SIGN ON MAST ARM PER STANDARD PLAN ES -6T, DETAIL "U" ❑5 INSTALL CITY FURNISHED VIDEO DETECTION CAMERA AND APPURTENANCES 10AS DIRECTED BY THE ENGINEER. �� Q�OF ESS/ pNgl swF�• Fy`' w V � N0. 26690 * EXP. 3.131.196 9jf OF CA1.�F��� P O L E S C H E D U L E L STANDARD ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING PED. S.N.S. PLACEMENT C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. PHASE MESSAGE A B A 24-4-80 30 35 15 *k 250 W 2—MAS, SV -1—T SP-1—CS 6 SANTA ANA AVE 1.5' 3' B 1—A 10 B 6 E TV— 1—T —11 3' C 19-4-80 30 25 15 250 W B 6 E MAS, SV -1—T SP-1—CS 8 MULBERRY AVE 6.5' 5' D 1—A 10 B 8 S TV— 1—T SP-1—CS 6 6' 6' E 19-4-80 30 30 15 250 W 2—MAS, SV -1—T SP-1—CS 2 SANTA ANA AVE F PPB POST 13,13 2,8 W,S G 1—A 10 TV— 1—T SP-1—CS 8 H 19-4-80 30 25 15 250 W MAS, SV— 1—T MULBERRY AVE I PPB POST B 2 W J 1—A 10 1 Tv— 1—T SP-1—CS 2 SCALE: 1"=20' INSTALL 1.5" CONDUIT WITH PULLROPE PER PAC. BELL REQUIREMENTS O 0 �c LUMINAIRE MAST ARM ON POLE ® TO BE STRAIGHT WITH NO RISE FROM MOUNTING FLANGE CONSTRUCT 4' PCC SIDEWALK PER CITY STANDARD NO. 105A AND AS DIRECTED BY THE ENGINEER. CONSTRUCT WHEELCHAIR RAMP •••••• ••� PER STATE STANDARD PLAN ' NSP A88, CASE "C", REPLACE LANDSCAPING AND REPAIR IRRIGATION SYSTEM AS DIRECTED SEE DETAIL "B", THIS SHEET BY THE ENGINEER. FOR CONSTRUCTION DETAILS 2"C, 2 #6, 1 #8, 4 #10, 4 #12 DETAIL " B" PP #4100290E 2 EDISON STALL HAND'HOLEH(SERVICE0P0 VC NT)CONDUIT WITH 3 #2 CONDUCTORS IRRIGATION BOX D/—WATER VALVE 1.5" C. 1 1C 1.5"C, 1 SIC W ►Wl= SD SD 3 02 i m 2^ s MULBERRY AVENUE 04 O 04 3 6 OO R/W i III I I� '1I o 8' 14' R/W C&G SEE SHEET 2 OF 3 FOR CONTINUATION OF INTERCONNECT SYSTEM. T 7 CONSTRUCTION NOTES 0 INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET, TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION, INCLUDING OPTICOM PHASE SELECTORS, TOP OF FOUNDATION SHALL BE 18' ABOVE SURROUNDING GRADE. Q INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING+ 120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V I UN—METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN SERVING UTILITY PORTION OF ENCLOSURE, Ioo �3 INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL. ® INSTALL R73-3 SIGN ON MAST ARM PER STANDARD PLAN ES -6T, DETAIL "U" ❑5 INSTALL CITY FURNISHED VIDEO DETECTION CAMERA AND APPURTENANCES 10AS DIRECTED BY THE ENGINEER. �� Q�OF ESS/ pNgl swF�• Fy`' w V � N0. 26690 * EXP. 3.131.196 9jf OF CA1.�F���