HomeMy WebLinkAbout2303-1CONDUCTOR
SCHEDULE
AW
CIRCUIT
'L
A
3
'LA
S
AA.L
�
FUTURF
01
3
3
3
3
3
6
3
3
PUSH
02
SIGNAL MOUNTING
PED.
S.N.S.
3
3
1 3
TYPE
HT.
SIG.
03
H.P.S.V.
TYPE
PHASE QUAD
VEHICLE
PED.
6
3
A
04
A
3
3
3
3
3
05
SP-1—CS
6
SANTA ANA
1 3
3
3
B
1—A
10
06
B
6
E
3
3
3
07
—11
3
3
3
3
3
15
250 W
B
08
E
MAS, SV -1—T
SP-1—CS
8
MULBERRY
3
3
5'
#14
02P
2
2
2
2
2
2
S
TV— 1—T
SP-1—CS
04P
2
2
2
2
4
2
30
15
06P
2—MAS, SV -1—T
2
4
2
2
08P
F
PPB POST
2
2
2
4
13,13
2,8
W,S
02 PPB
1
2
2
2
2
G
1—A
10
04 PPB
1
1
1
1
1
2
1
1
06 PPB
H
19-4-80
30
2
1
250 W
08 PPB
MAS, SV— 1—T
1
2
2
I
PPB COMMON
1
1
1
1
1
2
1
1
SPARES
3
3
3
3
3
6
3
3
TOTAL
10 119
22,29
Tv— 1—T
32
60
22
13
LUMINAIRE
2
2
2
2
1
2
2
#10
SIGNAL COMMON
1
1
1
1
1
2
1
1
TOTAL
1
3
3
3
3
2
3
3
# 8
1 GFCI GROUND
1
1
#61
SERVICE
2
2
#12 1
VIDEO CAMERA
2
2
2
2
2
2
VIDEO COAXIAL CABLE
1
1
2
2
1 4
1
1
OPTICOM CABLE
1
1
2
2
4
1
1
CONDUIT SIZE
2.5"
3"
3"
3"
3"
2—Y
3"
12.5"
�c CONTRACTOR TO FURNISH AND INSTALL VIDEO
DETECTION COAXIAL CABLE AND CONNECTORS
PER THE SPECIAL PROVISIONS.
— SD
FUTURF
W
1-800-422-4133
IT'S THE LAW 1 CALL AT LEAST TWO
DIAL BEFORE WORKING DAYS PRIOR
YOU DIGI TO EXCAVATING
O
ZGA �
�
UNDERGROUND SERVICE ALERT
OF SOUIHM CAUnNU
BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE
LOCATION OF UNDERGROUND UTILIIES BY CONTACTING
UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
d -
SD n
1.1
0
R/W
GRADE AREA FOR PEDESTRIAN ACCESS,
REPLACE LANDSCAPING AND MODIFY _
IRRIGATION SYSTEM AS DIRECTED BY
THE ENGINEER.
REMOVE EXISTING TREE
O'
R/W ... .....
C&G
EXIST. CATCH BASIN
U
w
DETAIL
AN
CONSTRUCT WHEELCHAIR RAMP
PER CITY STANDARD 104A WITH
LANDING AS SHOWN.
O
SEE DETAIL "A", THIS SHEET
ll
FOR CONSTRUCTION DETAILS
INSTALL R49 SIGN ON SIGNAL POLE 5 8 0
AS DIRECTED BY THE ENGINEER
w w wO —
EXISTING STREET LIGHT TO BE REMOVED BY OTHERS
SD— —SD —SD — —SD —
7
- - UFF6N - - -
SAN BERNARDINO COUNTY
bd W w w
PHASE DIAGRAM
FUTURF
P
1
201,3
S
94
�
FUTURF
4
b
.P15I
kl6
1 07
1 0'8
GENERAL NOTES.,
INSTALL R49 SIGN ON SIGNAL POLE � OO
AS DIRECTED BY THE ENGINEER
REMOVE 24" EUCALYPTUS TREES �
0
PP #580474H (PAC BELL) ---
TELEPHONE SERVICE POINT
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD
SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992)
2. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE,
HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE
ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING.
3. ALL PULLBOXES SHALL BE No, 5 AND CONDUIT SHALL BE 2' RIGID METAL EXCEPT AS SHOWN,
ALL VEHICLE HEADS SHALL BE METAL WITH ALL 12' GLASS LENSES, AND METAL ONE—PIECE
LOUVERED BACKPLATES, ALL RED INDICATIONS SHALL BE LED, ALL PEDESTRIAN HEADS SHALL
BE METAL WITH INTEGRAL CLAMSHELL MOUNT,
4. COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA
EDIS❑N COMPANY WELL IN ADVANCE OF NEED,
5, EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING
IS OPERATI❑NAL.
6. OBTAIN APPROVAL FOR EXACT EQUIPMENT L❑CATIONS PRIOR TO FINAL PLACEMENT,
7. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY
CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
8. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY
SPRINKLER SYSTEMS IF NECESSARY.
;,
06
01
0`
I
/04
30'
0
EX �T. P FT ERNE
JW —/
05
n.
SCALE: 1"=20'
INSTALL 1.5" CONDUIT WITH PULLROPE
PER PAC. BELL REQUIREMENTS
O
0
�c LUMINAIRE MAST ARM ON POLE ® TO BE STRAIGHT WITH NO RISE FROM MOUNTING FLANGE
CONSTRUCT 4' PCC SIDEWALK
PER CITY STANDARD NO. 105A
AND AS DIRECTED BY THE
ENGINEER.
CONSTRUCT WHEELCHAIR RAMP •••••• ••�
PER STATE STANDARD PLAN '
NSP A88, CASE "C", REPLACE
LANDSCAPING AND REPAIR
IRRIGATION SYSTEM AS DIRECTED
SEE DETAIL "B", THIS SHEET BY THE ENGINEER.
FOR CONSTRUCTION DETAILS
2"C, 2 #6, 1 #8, 4 #10, 4 #12 DETAIL " B"
PP #4100290E
2 EDISON STALL HAND'HOLEH(SERVICE0P0 VC NT)CONDUIT WITH 3 #2 CONDUCTORS
IRRIGATION BOX
D/—WATER VALVE
1.5" C. 1 1C
1.5"C, 1 SIC
W
►Wl=
SD
SD
3
02
i m 2^ s MULBERRY AVENUE
04 O
04 3 6 OO R/W
i III I I� '1I o
8' 14'
R/W
C&G
SEE SHEET 2 OF 3 FOR CONTINUATION
OF INTERCONNECT SYSTEM.
T 7
CONSTRUCTION NOTES
0 INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET,
TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS
FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL
ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION,
INCLUDING OPTICOM PHASE SELECTORS, TOP OF FOUNDATION SHALL BE 18' ABOVE SURROUNDING GRADE.
Q INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING+
120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V
I UN—METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL
CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN
SERVING UTILITY PORTION OF ENCLOSURE,
Ioo
�3 INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL.
® INSTALL R73-3 SIGN ON MAST ARM PER STANDARD PLAN ES -6T, DETAIL "U"
❑5 INSTALL CITY FURNISHED VIDEO DETECTION CAMERA AND APPURTENANCES
10AS DIRECTED BY THE ENGINEER.
�� Q�OF ESS/ pNgl
swF�• Fy`'
w V �
N0. 26690
* EXP. 3.131.196
9jf OF CA1.�F���
P
O L
E
S
C H E D U L
E
L
STANDARD
ARMS
LUMINAIRE
PED
PUSH
BT.
SIGNAL MOUNTING
PED.
S.N.S.
PLACEMENT
C
TYPE
HT.
SIG.
LUM.
H.P.S.V.
TYPE
PHASE QUAD
VEHICLE
PED.
PHASE
MESSAGE
A
B
A
24-4-80
30
35
15 *k
250 W
2—MAS, SV -1—T
SP-1—CS
6
SANTA ANA
AVE
1.5'
3'
B
1—A
10
B
6
E
TV— 1—T
—11
3'
C
19-4-80
30
25
15
250 W
B
6
E
MAS, SV -1—T
SP-1—CS
8
MULBERRY
AVE
6.5'
5'
D
1—A
10
B
8
S
TV— 1—T
SP-1—CS
6
6'
6'
E
19-4-80
30
30
15
250 W
2—MAS, SV -1—T
SP-1—CS
2
SANTA ANA
AVE
F
PPB POST
13,13
2,8
W,S
G
1—A
10
TV— 1—T
SP-1—CS
8
H
19-4-80
30
25
15
250 W
MAS, SV— 1—T
MULBERRY
AVE
I
PPB POST
B
2
W
J
1—A
10
1
Tv— 1—T
SP-1—CS
2
SCALE: 1"=20'
INSTALL 1.5" CONDUIT WITH PULLROPE
PER PAC. BELL REQUIREMENTS
O
0
�c LUMINAIRE MAST ARM ON POLE ® TO BE STRAIGHT WITH NO RISE FROM MOUNTING FLANGE
CONSTRUCT 4' PCC SIDEWALK
PER CITY STANDARD NO. 105A
AND AS DIRECTED BY THE
ENGINEER.
CONSTRUCT WHEELCHAIR RAMP •••••• ••�
PER STATE STANDARD PLAN '
NSP A88, CASE "C", REPLACE
LANDSCAPING AND REPAIR
IRRIGATION SYSTEM AS DIRECTED
SEE DETAIL "B", THIS SHEET BY THE ENGINEER.
FOR CONSTRUCTION DETAILS
2"C, 2 #6, 1 #8, 4 #10, 4 #12 DETAIL " B"
PP #4100290E
2 EDISON STALL HAND'HOLEH(SERVICE0P0 VC NT)CONDUIT WITH 3 #2 CONDUCTORS
IRRIGATION BOX
D/—WATER VALVE
1.5" C. 1 1C
1.5"C, 1 SIC
W
►Wl=
SD
SD
3
02
i m 2^ s MULBERRY AVENUE
04 O
04 3 6 OO R/W
i III I I� '1I o
8' 14'
R/W
C&G
SEE SHEET 2 OF 3 FOR CONTINUATION
OF INTERCONNECT SYSTEM.
T 7
CONSTRUCTION NOTES
0 INSTALL CITY FURNISHED CONTROLLER ASSEMBLY INCLUDING TYPE 'P' CABINET,
TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS
FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL
ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED OPERATION,
INCLUDING OPTICOM PHASE SELECTORS, TOP OF FOUNDATION SHALL BE 18' ABOVE SURROUNDING GRADE.
Q INSTALL TYPE III—BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING+
120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V
I UN—METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL
CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, PEC FOR LIGHTING IN
SERVING UTILITY PORTION OF ENCLOSURE,
Ioo
�3 INSTALL UNI—DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M511) OR EQUAL.
® INSTALL R73-3 SIGN ON MAST ARM PER STANDARD PLAN ES -6T, DETAIL "U"
❑5 INSTALL CITY FURNISHED VIDEO DETECTION CAMERA AND APPURTENANCES
10AS DIRECTED BY THE ENGINEER.
�� Q�OF ESS/ pNgl
swF�• Fy`'
w V �
N0. 26690
* EXP. 3.131.196
9jf OF CA1.�F���