HomeMy WebLinkAbout2221-2LJ—
LJ /
1.5" C. 1 -SIC CABLE
L
I
I
I
I
I
0
`Y'
r,
LJ
1,5" C. 1 -SIC CABLE
R/W
0
MERRILL AVE,
W w w
®- 1T - - - 7/ ®-L J- - - - 1T - - - - T� - - - -71 - -Ftg- - - E -l -U 17 - 71 - - - -7 - - _T - - - - TT - _r- - - - - 1 T- -1 - - - - 1T - -T 1 -
Il II w 11 II 11 II (TI 11 II 11 II 11 II 11 II 11 II
r r o—a-
oN
in 0i R/W m R/W
cu
W
I � Q
I I a
W I I >
CU
co
cu z
N /
R/W LD
i07- - � -
0
c:)
\
- — ...... . ...........LJ
_F0
1.5" C, 1 -SIC CABLE
—Ej — — — O
L�
W
J
3
El
W
pq
W
W
C-10
SEE DETAIL "A" BELOW I
�
OR C❑NNECTI❑N DETAIL EXISTING SIGANLIZED
I I I INTERSECTI❑N. SEE CITY
w
RECORD DRAWING NO, 1925
00 j FOR REFERENCE
I w w R/W
i L
II o
\
z 0i I I /
LJ _ I
J 1.5" C. 1 -SIC CABLE I I
LJ •� / — — — — —— — — — — — — — — —
-`� - - - - - - - - - - -- LO
I 1,5" C, 1 -SIC CABLE77
{
CD i
0i cu I
j I
I
I
0
� T
ur I
GENERAL NOTES:
1-800-422-4133
IT'S THE LAW I CALL AT LEAST TWO
DIAL BEFORE WORKING DAYS PRIOR
YOU DIGI TO EXCAVATING
cA L
UNDERGROUND SERVICE ALERT
OF SOUTHERN CAJFORMA
BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE
LOCATION OF UNDERGROUND UTILIIES BY CONTACTING
UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
R/W
EXIST. CONTROLLER ASSEMBLY
EXIST. 3" CONDUIT
0 0 1 1/2"C-1 IC
A A
#3 1/2 PULLBOX
O O
PLAN VIEW
rvinT nr%ki-mni i rn A e+elf- IBL I
C3 153 I` r_ W
N
I �I
R/W
1, TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD I
SPECIFICATI❑NS SECTION 86 AND STANDARD PLANS (DATED JULY 1992)
2. L❑CATION OF ALL UNDERGROUND UTILITITES ARE APPROXIMATE, THE CONTRACTOR SHALL I
DETERMINE THE EXACT LOCATI❑NS AND VERIFY ALL CONDITIONS ON THE JOB SITE. —N
HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE
ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING,
3. ALL PULLBOXES SHALL BE No, 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN,
ALL VEHICLE HEADS SHALL BE METALLIC WITH ALL 12" LENSES, AND METALLIC LOUVERED
BACKPLATES,
4. COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA
EDISON COMPANY WELL IN ADVANCE OF NEED,
5. EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING
IS OPERATIONAL.
6. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT.
7. PERFORM STRIPING REVISI❑NS PRIOR TO LOOP DETECTOR LAYOUT,
8. ALL LOOPS SHALL BE 6' x 6' WITH 10' SPACING IN THE DIRECTION OF TRAVEL AND
CENTERED IN THE LANE EXCEPT AS SHOWN. EXTEND LIMIT LINE LOOPS 1' PAST LIMIT LINE.
9. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY
CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER.
10. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY
SPRINKLER SYSTEMS IF NECESSARY,
11. PAVEMENT LEGENDS AND ARROWS SHALL MATCH THE CITY OF FONTANA'S MAINTENANCE STENCILS,
�O QROF ESS41 I
pNq!
CLYDE ELWYN
SWEET, JR.
� No. 26690
Expo p3 —3111 �o
CIVIL
W I
Q I
I
� I
I—
W W W I
N kD
mz
SEE SHEET 1 OF 2 FOR
m%,D z I
TRAFFIC SIGNAL PLAN & � � W �
CONTINUATION OF INTERCONNECT SYSTEM 4.R/W � pq