HomeMy WebLinkAbout2219-1F21 F3] F4] C 0 N D U C T 0 R S C H E D U L E R/ W CIRCUIT AA, 4 6 A 8 01 3 3 3 3 3 3 3 6 02 1 1 3 03 3 3 3 3 04 3 3 3 05 3 6 06 3 3 3 3 3 I II 07 3 3 3 W II 08 3 3 3 Li ( I II 02P 2 1 2 2 4 I I lI #14 04P 2 2 2 2 2 4 I II 1 06P 2 2 2 2 2 II 1 08P 2 2 2 4 I 11 11 02 PPB 1 2 2 1 I 11 04 PPB 1 1 11 1 1 1 2 I 06 PPB 1 2 2 2I 08 PPB 1 2 I 11 ( 1 PPB COMMON 1 1 1 1 1 1 1 2 Z I I I I I SPARES 3 3 3 3 3 3 3 6 —� TOTAL 13 19 25 29 10 19 22 60 Q I I II I �- #12 AUTOSCOPE 2 2 2 2 2 2 2 13 I I 1 LUMINAIRE 2 2 2 2 1 2 2 1 I II 1 P— #10 SIGNAL COMMON 1 1 1 1 1 1 1 2 I I I I I TOTAL 3 3 3 3 1 3 3 2 I I lI VIDEO CABLE 1 1 2 2- 1 1 4 I I I OP PCOM CABLE 1 1 22 1 1 4 CONDUIT SIZE 2.5 3 38 3m 2.5' 3' 3' 2-3 I 11 I J `u I I I I cu I II 1 I 0— 4 II © II R/W R/W Av 5 �sP w W- -T— — — — — — — — — SEE SHEET 2 of 2 FOR ROADWAY IMPROVEMENTS CONSTRUCTION NOTE INSTALL EC❑N❑LITE TYPE 90 CONTROLLER ASSEMBLY, INCLUDING TYPE "P' CABINET, AND APPURTENANT EQUIPMENT, SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL F6RNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED, INCLUDING OPTIC❑M AND AUTbSC❑PE CABLES, TO PROVIDE THE DESIRED OPERATION, CONTRACTOR TO OBTAIN CONTROLLER/AUTOSCOPE ASSEMBLY FROM THE CITY AT CONTRACTORS EXPENSE PER THE SPECIAL PROVISIONS. INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE INCLUDING THE FOLLOWING 120/240 V 1 PHASE SERVICE WITH 120 V METERED SIGNAL CIRCUIT, 120 V UN -METERED LIGHTING CIRCUIT, 100 A MAIN CIRCUIT BREAKER, 50 A SIGNAL CIRCUIT BREAKER, 30 A LIGHTING CIRCUIT BREAKER, 15 A CIRCUIT BREAKER FOR AUTOSCOPE CAMERAS, PEC FOR LIGHITING IN SERVING UTILITY PORTION OF ENCLOSURE, INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTIC❑M MODEL M511 OR EQUIVALENT) INSTALL CITY FURNISHED AUTOSCOPE CAMERA AND TERMINAL BOX PER ENGINEER`S DIRECTION. 1-800-422-4133 IT'S THE LAW ! CALL AT LEAST TWO DIAL BEFORE WORKING DAYS PRIOR YOU DIG! TO EXCAVATING � rA L� UNDERGRROUUNND SE ALERT CAUFOMA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 R/W 06 -T— — -4- L3 �T 02P I �1 04 6 -A 0 3 3 W R/W D P 0 L E S C H E D U L E o STANDARD ARMS 2. L❑CATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B 1 A 26-4-80 35 45' 15 250 W B 8 S MAS,MAS,SV-1—T SP-1—CS WALNUT VILLAGE PKWY 7.5 2.5 2 1—A 10' — — — B 2 W TV -1—T SP-1—CS — 10.5 2.5 3 24-4-80 35' 35' 15' 250 W B 2 W MAS, MAS, SV -1—T SIERRA AVE. 11.5 2.5 4 1—A 10' — — — TV -1—T SP-1—CS — 5.5 3.0 5 19-4-80 35' 3 0' 15' 250 W MAS,MAS,SV-1—T SP-1—CS WALNUT STREET 2.0 4.5 6 1—A 10 — — — B 6 E TV -1—T — 9.0 3.0 7 19-4-80 35' 25' 15 250 W B 6 E MAS, MAS, SV -1—T SP-1—CS SIERRA AVE. 8.5 7.0 8 1—A 10' 1 — — I — I B 8 S TV -1 —T SP-1—CS — 0.0 4.0 R/W w w PHASE DIAGRAM SPECIFICATI❑NS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. L❑CATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL ----------o ' ' 1 92 2'3 J '4 4---------- ALL VEHICLE HEADS SHALL BE METALLIC WITH ALL 12' LENSES, AND ❑NE -PIECE METALLIC LOUVERED BACKPLATES. ALL RED INDICATIONS SHALL BE LED'S PER THE SPECIAL PR❑VISI❑NS, 0'5 Z6 .217 0'8 # 4003985 E PROPOSED EDISON SERVIgE POINT � o - CL W_ 1 I I I I l38+00 , 3 13 0 4 II l I — —T— — — — — — — — — — — — — — — —T - 3w T -3w PVC CONDUIT WITH PULLR❑PE �� ❑ FOR ELECTRICAL SERVICE I �T 2 d# 2285497 E EX. STREET LIGHT 2 I TO BE REMOVED BY EDISON — — — — — 8 ° CG — JO 7 1 — — — — — --�— — — — — — — — —I— — — — — — — — — — — — — 0 8 P �� F2] 2' C,, 2 #61 1 #8 7 2" C., 2 #10, 4 #12 \1.5' CONDUIT WITH PULLROPE R/W I 2 FOR TELEPHONE INTERCONNECT TO PEDESTAL NO, UP1252 O R/W I � I I I I I I I I I I I I I I I 1 > I > I I I i I I 1. 39±D0= — I SIERRA AVENUE R/W GENERAL NOTES-1- R/W 1.TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATI❑NS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. L❑CATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE EXACT L❑CATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS, PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133, 48 HOURS BEFORE DIGGING, 3. ALL PULLBOXES SHALL BE No. 5 AND CONDUIT SHALL BE 2' RIGID METAL EXCEPT AS SHOWN. ALL VEHICLE HEADS SHALL BE METALLIC WITH ALL 12' LENSES, AND ❑NE -PIECE METALLIC LOUVERED BACKPLATES. ALL RED INDICATIONS SHALL BE LED'S PER THE SPECIAL PR❑VISI❑NS, 4. C❑ORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED, 5. EXISTING LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING IS OPERATIONAL, 6. OBTAIN APPROVAL FOR EXACT EQUIPMENT L❑CATIONS PRIOR TO FINAL PLACEMENT. ESSIONq� 7. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY o �C� E • SWF� Fye CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER, �,`k� -� y � Cv 8, CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY NO. 26690 SPRINKLER SYSTEMS IF NECESSARY, EXP. 3.L31/96 s/�11- ENG��, lql£ Of CAI.\E���� 41+00