HomeMy WebLinkAbout2200-22PC �-1800W — 120V PHOTO—CELL I f TIMECLOCK--,,F_ T_ I I I II I I I O I THE TIMECLOCK SHALL BE NON—ASTRONOMIC, 7—DAY CARRYI]VER. I L I I I I I I i I I I I I Bp NUMBER OF CONTACTS SHALL BE PER SCHEDULE PLUS I SPARES LISTED ON SCHEDULE, TYPICAL. ITO Rza CIRCUITS TO PANELS I SECURITY I R1S R1S II I I OTHER RELAYS I I C C AS REQUIRED II I I SEE SCHEDULES ICIRCUITS TO FIXTURES CONNECT IN PARALLEL I TO THE FIRST RELAY iCOIL, TYPICAL BP I CIRCUITS T❑ PANELS NDN ISECURITY I I RZA R2A I OTHER RELAYS I C C AS REQUIREDT T T T T T I SEE SCHEDULES IF ICIRCUITS TO FIXTURES I IN DENTES ASCD 25A CONTACT MULTI—PALE MAGNETICALLY I HELD RELAY — 600VAC RATED 120V COIL RATED FOR I PROVIDE INTEGRAL ALL LIGHTING TYPE INRUSH. NUMBER OF CONTACTS PER I TRANSFORMER DIAGRAMS —CIRCUITS PER LIGHTING CONTROL DIAGRAMS I TO 120V FOR 480V TYPICAL IPEDESTAL SERVICES I LOCKABLE ENCLOSURE WITH DOOR — WEATHERPROOF WHERE LOCATED ON BUILDING`S EXTERIOR, TYPICAL LIGHTING CONTROL NOTES THE MANUFACTURER OF RELAYS SHALL CONFIRM OPERATION OF THE SYSTEM WIRING DIAGRAM WITH THE EQUIPMENT SUPPLIED FOR THE FOLLOWING OPERATIONSt a) 'SECURITY' RELAYS TO BE ON ALL NIGHT (PHOTO— CELL ON — PHOTOCELL OFF) b) `R24' RELAYS SHALL OPERATE PHOTOCELL ON — TIMECLOCK OFF ALL NIGHT, e) SPARE CONTACTS ARE PROVIDED TO PERMIT THE SHIFTING OF CIRCUITS BETWEEN RELAYS AT A LATER DATE d) LEAVE SUFFICIENT COILED CONDUCTOR, SO THAT ANY CIRCUIT CAN BE CONNECTED TO ANY RELAY CONTACT e) PROVIDE CODE BARRIER BETWEEN VOLTAGES BP —DENOTES BYPASS SWITCH FOR DAYTIME MAINTENANCE, TYPICAL. TIMECLOCK, TYPICAL HL13 SCHEDULE HL13 RELAY CIRCUIT ., NUMBER B-..- NUMBER HL13-1 R1S HL 13 1, 6,7; 12 POLETOPS 16 POLETOPS HL13-¢1 R2A HL 13 3,5j9111 POLETOPS 8, 10, 1 4, 13 POLETOPS HL1 3 LIGHTING CONTROL DIAGRAM N9T*S* ,2S RECORD DRAWING The information on this drawing is obtained from others and must be verified in the field by anyone prior to use or construction. ._Corgale4or7i 45 not responsible for underground facility locations or depictions. All above ground facilities can he readily seen and verified by the parties that intend to use sage. R.E. MALL & V 2842 Walnut Ave., Ste. A ASSOCIATES Tustin, CA 92680 INCORPORATED FAX 714544-4762 714-5442783 Registered Electrical Engineers Copyright 1992 REcaKe / on i11 LIGHTING CONTROL DIAGRAM (TYPICAL FOR ALL EXTERIOR LIGHTING CONTROLS) AND NOTES 5i N`�REV,s,oNs �`� " — i ;Fo�",�, DATE .00In„ o<.E ,o-os-sz ALTERNATOR RELAY, TYP, E SC-HEDULE (BELOW) THE RELAY CONTACT RCUIT NUMBERS, TYP. BER OF SPARE 25 AMP 4ETICALLY HELD RELAY CONTACTS, TYPICAL NUMBER OF 25 AMP JETICALLY HELD RELAY CONTACTS, TYPICAL WIRE PER THE CONTACT SCHEDULE, TYPICAL CITY OF FONTANA, 0FESS1p���1 CALIFORNIA DRAWN BY PARK AND RIDE FACILITY SCALE: scE PARCEL 131 P.M. 12195 DESIGNED BY HORIZ.: NONE FDP LIGHTING CONTROL DIAGRAM.S., CHECKED BY DATE: 17550 SLOVER AVE. 1Z -T92 JOB N0.� E•YP. /2-31-93 DR. N0. DWG. N0. APPROVED w Cv�� /s'ir-9s- L379P—LC 4013-045 6.s CITY ENGINEER R.C.EZS/ZG I Z240 E5 OF E7 SHT. 22 OF � 245'