Loading...
HomeMy WebLinkAbout2182-1B,' W.I. ENCL IV X 2" CAP. 1" X I" RAILING R 5" O.C. 21' X 2" POST 8'-0" O.C. 1k" X 2" BOTTOM RAIL. FINISH GRADE OR SURFACE SEE CONSTRUCTION PLAN. i CONCRETE FOOTING. SELF CLOSING, SELF- LATCHINGG CATE. SEE CONST. PLAN FOR SIZE AND LOCATION. USE HEAVY HTWES & KEY OPERATED DEAD BOLT. SHALL BE TUBULAR SHARE .D, PR IME AND WELD VS. ENTIRE FENCE TO RrAar t vr. VINE COAT OF RUSTOLEUM SEE L.A. FOIL COLOR. ' OSURE FENCE 7►��V1� NAIONAL T*AC.�q M/w NO. `.• A - A O x 1= 6 J.. I" WATEIZ METES P.O.C. - PROVIPEP BY DEVFL0PE IZ - 5YSTE.j"1 DENONED � MIN. 60 P b I. PE12 FONTANA WP. MAX. FLOW ALLOWED. Sa GPM. MANGO AA. -L 00i �r_*Cmo VINS� Zx40 *PN Q gclo old 0?4� T� TUri41k, V1NE'P0CKE7-. AurorlATI C CONTROLLI! '13' R,Rr R OL M C. 7 115 V X00 CYC . 2 AMP EL..a CTR I C C I RCU 17 PROVIDED aY DLVEL.ZeE� R LOCATION PETERMINU. IN / /AVENUE W� V' co 0 J . &/0 EASE (RADIUS) EDGES M LAWN OR PLANTING AREA 2" BELOW FIN. SURFACE 1/4r STEEL IT1141JOU4 COMPACTED SOIL COLOR AND TEXTURE SEE PLANS PROVLM EXPANII-ON JOINTS MAX 88 QC. CONCRETE MOWSTRIe DETAIL. I NOTES - 120 VOLT ELECTRICAL POWER OUTLET FOR CONTROLLER TO BE PROVIDED BY OTHERS. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HOOK-UP FROM OUTLET TO CONTROLLER. ALL WIRE FROM CONTROLLER TO ELECTRIC CONTROL VALVES TO BE COPPER OF #14 DIRECT BURIAL. USE BLACK FOR PILOT - WHITE FOR COMMON. INSTALL IN COMMON TRENCH WITH MAIN LINE PIPING WHERE POSSIBLE. PROVIDE MINIMUM 18" COVER. ' PROVIDE MINIMUM 18" COVER OVER ALL PRESSURE MAIN LINE PIPING AND 12" OVER ALL NUN -PRESSURE LATERAL LINE PIPING. ALL PIPE UNDER PAVED AREAS TO BE PVC SCH. 40 INSTALLED PRIOR TO PAVING. - FINAL LOCATION OF AUTOMATIC CONTROLLER TO BE DETERMINED BY OWNER'S AUTHORIZED REPRESENTA- TIVE, AND/OR LANDSCAPE ARCHITECT. u THIS MIGN IS DIAGRAMMATIC. EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARIFICATION ONLY AND IS TO BE INSTALLED WITHIN PLANTED AREAS WHEREVER POSSIBLE. IRRIGATION CONTRACTOR SHALL FLUSH ALL LINES AND ADJUST ALL HEADS FOR MAXIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, DRIVES, AND BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT EXISTING SITE CONDITIONS. DO NOT WILLFULLY INSTALL THE SYSTEM AS DESIGNED WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT WERE NOT KNOWN DURING DESIGNING.; SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTA- TIVE, OTHERWISE THE IRRIGATION CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY AND ALL NECESSARY REVISIONS. INSTALL ALL EQUIPMENT AS SHOWN IN DETAILS. SYSTEM DESIGN IS BASED ON MINIMUM OPERATING PRESSURE SHOWN AT EACH POINT OF CONNECTION. MAXIMUM GPM DEMAND SPECIFIED. IRRIGATION CONTRACTOR SHA4,L VERIFY ALL PRESSURES ONrSITE PRIOR TO CONSTRUCTION. UPON COMPLETION OF JOB PROVIDE OWNER WITH A REPRODUCIBLE SET OF "AS,BUILT" DRAWINGS. THE SYSTEM SHALL BE FULLY GUARANTEED FOR A PERIOD OP ONE YEAR. ANY DEFECTIVE MATERIAL OR POOR WORKMANSHIP SHALL BE RF,P4_ACED OR CORRECTED BY THE IRRIGATION CONTRACTOR AT NO COST TO THE OWNER. ALL MIRE SPLICES TO BE MADE WITH PEN-TITE WIRE CONNECTORS OR SCOTCH -LOC #3577 SEALING PACK. SLOPE AREA PIPING: ALL PIPE ON FACE OF SLOPES TO BE SCHEDULE 40 '� � I*STALLE© d* -GRA .: STAKE PIPE EA,.10'0" 0. USING EBA SECUYVELY EA. 10'0" .`" R LENGTH AS SHOWN ON DETAIL. TI 0 C WITH #14 G A L V , WIRE. i3 QI+L, . IRRIGATION. LEGEND SYME OL ASG MOD NO DESCRIPTION NOZ RAD GPM PSI PATI'EIZN Toro 324-10-05 Pop-up 05 44' 1.4 40 Qtr 328-10-05 Stream rotor 05 44' 2.2 40 115 119-8910 L1 328-10-05 05 44' 2.8 40 Half 0 338-10-05 05 44' 5.6 40 Full �7 570-4P 4" Lam pop-up 151Q 15' 1.0 30 Qtr V 151H 15' 2.0 30 Half O 151F 15' 4.0 30 Full S60OS-PC-3.0 Gear Driven Rotor 3.0 43' 2.8 35 Part Circle (b Rainbird- A18 22SS Stream Spray --- 22' 1.61 30 Half i b t A18 16SLA Stream Spray -, Low Angle 16' 1.61 30 Half/ i V x Toro S600C Gear Driven Rotor 3.0 43' 2.8 35 Part Circle i • 0 Full Circle 2" water Mir by a mw Fieboo 80S Double Ck, Backfivw Prev. Lira Sbw - In a loddM vwdal J=K- H Nibo© T-113 Gate Valve Line Size 4$� Raiz bird EP -ICP -PRS Electric Remote Control Valve, Pressure Regulating ' -ISC 24 Station Irrigation Controller, Pedistal Mount - Install in lemur box - paint with one coat primer, two coats 'FOREST GREEN'. Q Rainbird 33D-LVC Quick Coupler Valve - 1" Gals Iron SCH 40 Irrigation Main on slope surface - Stake @ 10' O.C. PWC SCH 40 CL 315 Irrigation main - 18" caner - Use SCH 40 for 3/4 to 1-1/2" PVC CL 200 Sprinkler latteral - 12" cower UV'R PWC SCH 40 Sprinkler lateral on slope surface - Stake @ 10' O.C. - - Gee Spring lo&ded check valve - Line size U Toro 570-6P 6" Shrub pop-up 10' HLA 10' 0.9 20 Half 0 570-6P Strip Spray 91SST 9 x 18 1.0 20 -- ■ 512-30 Stream Bubbler -- 41/2' 1.0 10 4/60 j p IN 720-30 Tensiometer - water con ;ervatiroan system-- yydrovisOr control ler A.1 regulator /A- I ( Indicates f law- it GPM {TH TES A. SOIL PREPARATION: IN ALL PLANTING AREAS THE FOLLOWING APPLICATION SHALL BE MADE PER 19000 SQUARE FEET OF AREA AND SHALL BE THOROUGHLY CULTIVATED IN TWO DIRECTION INTO THE TOP 6" OF SOIL, AND THE AREA WATERED DOWN: 4 CU. YDS. NITROGEN STABILIZED SAWDUST 100 LBS. AGRICULTURAL GYPSUM 10 LBS. 16-6-8 COMMERCIAL FERTILIZER * OR PENDING FINAL SOIL REPORT B. BACKFILL: SOIL MIX FOR BACKFILL IN PITS FOR TREES AND VINES SMALL CONSIST OF THE FOL- LOWING: AMOUNT / CUBIC YARD BY VOLUME ON-SITE /j- BY VOLUME ORGANIS AMENDMENT • '- -� PENDING FINAL SOILS REPORT THE PLANTING PITS FOR TREES AND SHRUBS SHOULD BE EXCAVATED TWICE THE DIAMETER AND TWICE THE DEPTH OF THE ROOTBALL. ON-SITE SCREENED SOIL SHOULD BE USED WITH- OUT AMENDING FOR BACKFILL TO THE DEPTH OF THE ROOTBALL AND THE BACKFILL MIX AS ABOVE SHALL BE USED AROUND THE ROOTBALL. THE PREPARED SOIL SHALL BE UNIFORMLY BLENDED IN AN AREA ADJACENT TO THE PLANTING WORK AND SHALL BE ACCURATELY PROPORTIONED USING A SUITABLE MEASURING CONTAINER. UNUSED EXCAVATED SOIL SHALL BE REMOVED FROM THE SITE. PROTECT THE MIX FROM WATER UNTIL IT HAS BEEN PLACED IN BACKFILL AROUND PLANTS. C. VINES: ALL VINES SHALL BE REMOVE FROM THE STAKE ARID FASTED TO ADJACENT WALLS AS FOLLOWS: WOOD WALLS - GALVANIZED "U" STAPLES AND "TWIST TIES" (NOT STAPLE GUN). - CONCRETE & MASONARY WALLS - CLEAR PLASTIC TIE TABS SECURED TO WALL WITH CLEAR SILICONE GLUE AND "TWIST TIES". D. PRUNING: ALL SPECIMEN TREES 24" - BOX AND LARGER, SHALL BE PRUNED AND THINNED BY 25% OF THE CANOPY UNDER THE DIRECTION OF THE L.A. a 10% OF t`Li..L CONTAINER MATERIAL SHALL BE PRUNED TO ENCOURAGE HEDGE MASSES UNDER THE DIRECTION OF SHE L.A. 4 . DEPARTMENT SIGNATURE DATE PUBLIC WORKS PLANNING ENGINEERM PARKS / REG, L Q U I 1-- Z 2 Q M � J � OaN w>-� WEU y- OYC OaC a H � W M a z a z 0 LL I ri 0LO LO J Q M1 LLJ C/) � r 'N Q N � V �a Q W U Q ui Q Y Z Q Z c � coo 0 � n I&1 CHECKED OAT IE 1'= 20" .- a� .JO• NO.//"; 2�(C/ �. SHEET ''• t OF ,a SHEETS 1 L1 W .2 192, 4