HomeMy WebLinkAbout2155-1f
L
TRA C T /3 750
1 4.
i�POFt�SEO � Q
/MP,�YEN/E 0
Z4TH I 5'i- ��T
VICIA117Y MAP
L
/Vo scAL�
01
KEY MAP
v
i
LAN�SCp►P�
LANDSCAPE � �/
1 20'
0.5 d
1 �
r
r �l
GENERkL VOTES
1. All work shall be done in accordance with these plans, the City of
Rancho Cucamonga Standards and the Standard Specifications for Public
Works Construe_ n - current edition. Contractor shall be familiar
with and shall In responsible for adherance to these Standards and
Specifications.
r i
4
2. All pipelines of substructures of any kind, telephone or power poles,
water meters, valves, fire hydrants, etc. shown or not shown on these 5TREET
IMPROVE.MENT.
i plans within the right-of-way limits or in adjacent areas where
improvement work is to be done shall be removed, relocated or protected
! in place as required at no cost to the City of Rancho Cucamonga.
TRACT NC
1 375C
® 3. Any contractor performing work on this project shall familiarize him-,
/V it
s
1.5
Aw
7�
EX/ST. ACPAt/Tl
�4 STS
(�7YP/CAL S�CT�ON- WAST Off' C� /��2RY Q Y6�
7-/
5TA• 504 +09-t9 TO STA•509.1.40.00
24 Tf'' STREET
C7YP/CAL SECTION - E�1 ST 0�' C 2�Y �l YE>
T/. =9.0 R-- �5
5TA T/O�/ 5 /0 t 00.09 ?a ST,A T/OA' _,512;,A9.6-04
iq
self with the sits and shall be solely responsible for any damage to
existing facilities resulting directly or indirectly from his opera-
tions, whether or not such facilities are shown on these plans.
±S4. A permi�to20pp—k/6
��obta ned fro* the City of Rancho Cucaidbnga�;EngineeringDepartmenr.
o any encroachment or construction within City of
Rancho Cucamonga easement or right-of-wiy.
5. All grade stakes shall be set by the Contractor or Engineer. Paving
stakes shall be set at all hinge points, edge of -pavement points
within 0,01 foot of sub -grade elevation and at not more than 50 foot
intervals. Additional paving stakes may be required by City Engineer
as needed at warped or vertical curve areas. `
6. All sewer, water, electric, gas, phone or other utility laterals,
mains, or crossings shall be constructed prior to paving.
7. Compaction tests of•embankment construction, trench backfill, com- ;
pacting original ground and all sub -grades shall be performed ar no
cost to the City of Rancho Cucavwmga. A written report with these
COIV97—RCICT-IOINI iVOTES 041AN777 YE671- 1 fA7-6
compaction tests shall be submitted to the City Engineer for approval
base
u�Q,��
prior to the placement of materials and/or surfacing.
i
/fly
P� Z
8. At the completion of paving, a materials report shall be submitted to
.
�!--CONS'T'2UGT L /YE' APPrPOACN W/TH S10, IFWA R4!5r,2
the City Engineer, Jishnq all tests or determinations completed to
verify stability oil content and Gradation of asphalt Paving
j
—
C64CAA40/1VoA 670 /V0. -Z" ; _
! ,EA.
¢rg8
2994
2-COI�S7=,�"C.�" (�y��4�GUTT ,� P��e RA►A/C�/O GfJCA/�l0/%/GA STD //0.30.3.-
3, 2 G.F.
9• Prior to instal latic-, of any naving, a materials report shall be - -
submittea to the City Engineer, listing all tests or determinations
3
�"'CONST. BrK45WAY 5YOEWAGK P��e RA/VCl/O CUCA1�loIvGA S"l0 NO. .311.
,3,��Z 15F
completed to verify tiara analysis and sand equivalent of
aggregate base. _
-
�- Co/u57 7-t5MPa,,eARY e ",A C. BERM PC-Ae RANcf /0 CUCAA,ro/VGA sr,r,)
10. Paving shall be performed in accordance with R - Value and Pavement tests
taken to determine structural sections (prior to final plan approval)
a- Po IryE�e �� � ,Q��oc�►T/olU `_ -
� EA.
_ -_ - -- - -1----_ -- -. --
11. When improvements are to be placed on native soil which consists of a
rocky material, the sub -grade shall be prepared by removing all rocks
e-CUreBo/vLY PSR F2ANCf-/a C(�ANloNGA STO. /Vo.3o/.
I%�/Z L.F.
which protrude above the sub -grade and all voids or depressions shall be
filled with a fine 'grade material of a quality Oetter than the native
2!, 97G
4,2,I8
TO a
'
material.
�' VA G U� A T IM45� oma' C0/VST,QI�CT/O/V
120 If the asphalt concrete is to be placed on sub��•ade, a soils star i 1 ant
registered by the E. P.A. for use under A.C.and ' P.C.C. shall be
90-
uniformly applied at the manufacturer's reconmled rate for the full
@PAIN7-�5DA,/ ,OIAM�.SElEe 16i4/A1C7 ST,�/rD/1IC PG�J ,�
�$�
Pavement width prior to paving.
�•�
13. Estimate of quantities is provided b the En ir4er only for the
q P y 9 y
convenience of the developer, the contractor skill make his ower
determination of construction quantities before Is a" bid. Any
EA
item of work required by these plans which is specifically listed in
the estimate of quantities shall be considered included in the other
.-_
4
/3 CONST. ,4AMP PE,e RANCA10 Cl/6'AM0/YGA -7-0 /Vo. /o246 -O
L �A.
items of work.
I1V!67-A6L 22,0006 A//c54/ ! TREETG/ci;W7-01VA TYPE /.5 S/GNAL AA149 G� NTt1NO
14. Street signs per City of Rancho Cucamonga Stand d Nwikers 401 and 402
/UT /Sl�s/��P, AM
A RVGC- W1 7'1-1 l� GUM/A/AIR� A?e1W 2 CDV�
shall be constructed at each intersection.
,,-OU/YOAT/ON PER CAL TRANS' 67ANQ4,e451
BW CtJTo�f 7YPE W -17-1-1P vTo�G�G'T�e�c div/Tl7adt�/nsrA4�T- D As PAeof
L-Aio�.
��
� 15 City approval of plans, does not relieve, the dove er from
2
TRA FF/C 5/aNaL 1/4STA L
f
responsibility for the correction of error and ss 1 on discovered
�--
G A IG A G �1 �/O G /�'h'T/N�
��-lfySTA�� 22,000 f/P5'� �'TR�ET � �/T'o/V �_ 5 N
during construction. Upon request the required an revisions shall be
SrA1VDARo POG., 11v/ry 1-5'�Un�/r�Q.�,e�A,en�r, 2 "CoNGY✓�T SGY��P L4N0
promptly submitted to the City Engineer for app al.
,ol1N04 7/,OA/ Pyre CA G TQan1S� srAlvZ24RV PGA `�5 - .� . G Un��N'4
AeTO
Z7"Y14'5 �
8� CUTOFF TO�irC fT�/lYT4F
Y/T�PVO
16 Work site and exterior streets shall be in a neA clean, hazard free, r
2
,eA)c`/C 51alvV l- 1"57ALL,QT/DIS/,
orderlystate throughout construction. Site s*l be cleaned on
� 9 up
AA Ps. v) BY V .c.t ., 1-A40 XO,e Auo
�'
request of the inspector.
O
I3
17. Contact UNDERGROUND ALERT 1-800-422-4133 and the %llowing Utility
CoN97 �t�I 7014 A! FZAAZz PeR C 1C4,WOy`,4 �'1�. 8/¢
RA •
Companies as- requ i red, 2 working days prior to?ffldft�at i on .
v
CONSTRUCT C.B. No.1 ?6 It CITY 0E- RAMC 0 C-UC-AMoN6 A STD. sox (W as fhowh
2 EA .
<
t8 CONSTRUCT LOC^L 'b�'P(tert loN pelt C.►T4 OF R.C. ST5. S t S (('AtSE C ")
.Z 1 •R
Provided for your convenience are the following:
{SER s�GivAG P�Alvs
A. Cucamonga County Water District
9641 San Bernardino Road (714) 987-2591
Rancho Cucamonga, CA 91730
B. San Gabriel Valley Municipal Water District �.
Mr. Bob Stallings - For BASE LINE constrectiom (818) 969-7911 -
C. Metropolitan Water District.
P.O. Box 54153 (Z/ )2150_"77f0
Los Angeles, CA 90054 Ext. 6461
*Note: UNOERGROUNO ALERT CONTACTS: �
GENERAL TELEPHONE
SO. CALIFORNIA EDISON
SO. CALIFORNIA GAS COMPANY
CABLE COMPANIES
Mf ESS1 ;
i . 22015
Exp 9-30-93 '
LAn�DSCAPE �/ g * DESCRIPTION OF MVISION DATE APPROVED,
��15�Jf95iV T &
�,�`�
OFCAM-\FCITY OF
RANCHO CUCAMONGA
Zo /2 32 32 /2
9 e,� STRUT- �MP��/i1�lENT F'GA►/1/5
4
- 8
TRACT NO. /3 7.50 .,
Contractor agrees that he shall assume sole and complete responsibility for job ! APPROVED BY: DATE' �^.
site conditions during the course of construction of this Project, including safety of all CITY OF FON CITY ENGINEER RC.E. NO.0
persons and property; that this _ 0VA
pc p opC y, t t u requirement shall apply continuously and not be lim- (TYPICAL S�CTIOIV 4Asr oic"Cl- �,e�eYAv6� DESIGN RECOMMENDED
itcd to normal working hours; and that the Contractor shall defend, indemnify and 77/-0-0 R- 6 5i
DP^WIIJ4 90 Z1.5
hold the Owner and the En incer harmless from any and ail Jiability, real or alleged, 1 �7"AT/oN 5f2-195.04 �AST-,
in connection with the per�ormancc of work on this Project, excepting for liability DRAWN `""`
�` SHEET
arising from the sole negligence of the Owner or the Engineer. ✓ � ,
` 7_ ��_yz. ,l �OF
BY: CHECKEDN0
WING .
R.C.E. '25126 .DATE, _ R.E.E. NO4.f.0,'' ?aS
DATE FILE NO '
/ PRO.laCT gs;woe r moo.
s.Al