Loading...
HomeMy WebLinkAbout2145-1BASELINE i INDEX MAP NTS THOMAS BROS REF PAGE 14 GRID E-1 VICINITY MAP NORTH NTS Q*Of /'�" MELVIN W. THATCHER III �c No. 39964 CCIVIL ,n. ENGINEERING p �d u WJ H w W t!1 W W CA AVENUE 0.5' C PALM LANE & LAUREL AVENUE PARCEL MAP 14130 CITY OF FONTANA n niki R/W "TYPICAL SECTION PALM LANE NTS 0.5' R/W TYPICAL SECTION A 3.00% - 4.30% LAUREL AVE NTS PRIVATE ENGINEER'S MOTE THE PRIVATE ENGINEER SIGNING THESE PLAINS IS RESPONSIBLE FOR ASSURING THE ACCURACY AND -ACCEPTABILITY OF THE WORK HEREON. IN THE EVENT OF DESCREPANCIES ARISING DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPOINSIBLE FOR DETERMINING AN ACCEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY THE CITY. (THIS NOTE REQUIRED ON ALL PLANS). ® 2.20% - 2.50% PAVING NOTES GENERAL NOTES I. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. EXCAVATION ARID CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS, 3. PAVEMENT SECTION SHOWN IS 'PRELIMINARY ONLY FOR PURPOSES OF ESTIMATE OF QUANTITIES, AND IS SUBJECT TO REVISION AND APPROVAL BY CITY AS REQUIRED AFTER COMPLETION OF ROUGH GRADING. 4. LOCATIONS OF PUBLIC UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE TRUE LOCATION AND ELEVATION IN THE FIELD OF ANY EXISTING UTILITIES AND TO EXERCISE PROPER PRECAUTIONS TO AVOID INJURY OR DAMAGE THERETO, CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT FOR UTILITY LOCATION BEFORE EXCAVATION AT 1-800-422-4133. 5. STERILANT REQUIRED UNDER ALL AC PAVEMENT. 6. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL . ADJOINING CURBS AND SIDEWALKS. 7. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR SO AS NOT TO CAUSE ANY MUD, SILT, OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION, ANY MUD OR DEBRIS ON PUBLIC PROPERTY SHALL BE REMOVED IMMEDIATELY. DUST SHALL BE CONTROLLED BY WATERING OR OTHER APPROVED METHOD THROUGHOUT THE GRADING AND CONSTRUCTION OPERATIONS. 8, CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR LEAVING IMPROVEMENTS, CONSTR.UCTIONt MOTESIESTIMATE OF QUANITITIES 8" PCC CURB & GUTTER PER FONTANA STND 101 0 AC PAVING 4- OVER AGG BASE 4" ACTUAL THICKNESS OF BASE MATERIAL TO BE DETERMINED BY SOIL TEST AND RECOMMENDED BY THE SOILS ENGINEER R, VALUES, SAND EQUIVALENTS AND STRUCTURAL SECTION OF STREETS SHALL BE SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING, CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR LEAVING IMPROVEMENTS, PAVEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH. CONSTRUCT "A.C. OVER" A.B, PAVING. (ASSUME 4" A,C, OVER NATIVE FOR ESTIMATING PURPOSES ONLY. ACTUAL PAVING THICKNESS TO BE DETERMINED PER PAVING NOTE ON SHEET 1. 3 REMOVE EXISTING AC PAVEMENT 4 FCC SIDEWALK PER FONTANA STIND 100-C 5 PCC DRIVEWAY APPROACH W= 14' PER FONTANA STIND 102 6 SAWCUT EXISTIING AC PAVEMENT 7 AC OVERLAY (0,1') 8 2' FEATHER FOR SMOOTH TRANSITION 9 8 " AC BERM 0 INSTALL BARRICADE PER CITY STD 118 1. REMOVE BARRICADE 11INSTALL REDWOOD HEADER INSTALL 6" PCC CURB AND GUTTER PER CITY STD 101 INSTALL 4" SEWER LATERAL PER CITY STIND 125 60 LF 73 TOMS AC 73 TONS BASE 368 S 530 SF J TOM 167 LF 2020 SF 290 SF 74 LF 75 LF 32 L 80 LF CONSTRUCT AC DRIVEWAY APPROACH TO MATCH EXISTING 10' DIRT DRIVEWAY W=1.2', X- 1 EA