Loading...
HomeMy WebLinkAbout2127-1Conduit not to be Installed outside of park property and City right- of-way until written permission is obtained from the owner. • FUTURE STRE-ET • %.r r% r— e% n sir .^ •'A.. C .00.o•V .c 7 0'0 1>. /43 ?4 tfo 7�fyo'o, k i10/ Qty/ o. JQ - - Q ! st b, Lij � a y r•. II f l .�. ' •�f .x,11 y, , '`` _ O 1049.11 �•1. been Space 4- 1 t 56 14 P.G. , 52� deeded to City) 54.21 rO M .. 01 SCALE: 1" , To tel PedeSt a! GENERAL NOTES UNDERGROUND r TELEPHONE SPECIFICATIONS 1, Install 1 -`4' conduit with pull rope. Plastic and/or galvanized steel conduit are acceptable. 1. All conduits bends to have minimum radius In feet equal to diameter of conduit in inches. J.:� - Pond . 2" diameter = 2! radius, etc. :, ... • �' ' L 12" No conduit run to have over two 900 bends, if necessary to have over two 900 bends Ix specifications attached here -on. Horizontal sweeps) to be 12.5' radius. Sweeps at inset accessible pull box in run. Contact Telephone engineer for pull box sizing. pedestal and pullbox to be 480. ! � ti 17 3. All conduit shall be left clean, dry, and free of debris or other obstructions. A pull line _ 2. .. ti s 5�.1 FS • ' �, 4. "t GRADED VAI1t water and gas pipes must not be used. 3. Open trench is allowed in unpaved areas. Under pavement areas shall be installed by 5. Conduit terminated on a pole must be turned up 1' above finish grade, in the opposite 56•b F5 '. quadrant from any power services. (See detail of pole for termination). Interferences if necessary. If Any pavement arias are trenched, the asphalt shall be removed and replaced for the trench width plus 12" additional on each side of the trench 6. Conduit placed In same trench with power conduit must be separated by not less than . / \ 56,3 FS 12" of well packed dirt or 3" of concrete, and have not less than 30" of cover. 4. Contact Underground Service Alert 2 working days before digging at 1-800-642-2444. 7. Approved Plastic Conduit P.V.C. Sch. 40 PTSB 66 PTS 66 2" 5. Bid price is lump sum. No extras will be allowed for underground utilities not being as To tel PedeSt a! Area li ht 3 1-5"12Kv Electric to Cypress �2 - 2" Power to pump ' 1 - 2" Telephone to entrance e X17"x30"x1211 r tel. pulibo* / Area light Post top mounted typical mast arm mounted ,, ..� 4 ` r t �ypical 12 Kv U.Q. Electric! v% �. 1: Main Electrical �\ n Switchgear \� ! Ya Secondary Electric <tg 1 4' Sewer clean out Exact location of electric conduits t, \ unknown ' . • Q�=�@tY��� Y DETAIL 0 P41 T ® r Building,; No, .29570 f`f 11501 Cypre yz These plans and specificatlons are the exclusive property of the Agency and shall Exp, 3-31 -91 �" not be used In any manner without prior consent of the Agency. Any reuse of these plans and specifications by the Agency or Others shall be at the Agency's and/or Other's sole risk and without ilabillty to BSI Consultants, Inc. , ■ PREPARE U E SUPERVISION OF: APPROVED BY: _ R EVISIONS R EFERE.N.CES CONSULTANTS, INC. UND RGROUND LEPHONE SERVICE Consultonts to Governmental Aencles� ! APPY03oLogNATURE CEN TER 1906 S. Commercenter E. Ste. 204 Son Bernardino CA 92408 f. DA�p �r'e i scd u�i /iirir�so�c7`Qrr ir�lavlTcd Z9s _ (714} 884 2500 CuDATE � -EXP. 3� g� DESIGN: DRAFT; JURUPA HILL REGIONAL PARK•. CHECK: DATE:..R.C.E. Zs+lZeo EXP. rt• ?t•69 DATE M. N0. ' 12 CITY OE FONTANA - DEPARTMENT OF PUBLIC WORKS ��RA CITY ENGINEER SHEET OF 1mood N. Z C. SCALE: 1 2C GENERAL NOTES UNDERGROUND r TELEPHONE SPECIFICATIONS 1, Install 1 -`4' conduit with pull rope. Plastic and/or galvanized steel conduit are acceptable. 1. All conduits bends to have minimum radius In feet equal to diameter of conduit in inches. The installation shall conform to Standard Specifications for Public Works Construction, . 2" diameter = 2! radius, etc. 1988 Edition, except as modified by these notes and the underground telephone 2. No conduit run to have over two 900 bends, if necessary to have over two 900 bends specifications attached here -on. Horizontal sweeps) to be 12.5' radius. Sweeps at inset accessible pull box in run. Contact Telephone engineer for pull box sizing. pedestal and pullbox to be 480. 3. All conduit shall be left clean, dry, and free of debris or other obstructions. A pull line _ 2. Existing underground utilities are plotted from available records and visible puliboxes, equivalent to No. •14 AWG -3/16" polpropylene or conduit measuring tape to be Installed. . s clean -outs, etc. The contractor shall exercise extreme caution to expose and protect all utilities prior to trenching and/or boring conduit. 4. Approved plastic is specified In underground construction. Condulets, plumber's fitting, water and gas pipes must not be used. 3. Open trench is allowed in unpaved areas. Under pavement areas shall be installed by 5. Conduit terminated on a pole must be turned up 1' above finish grade, in the opposite boring except that the contractor will be allowed to trench the access road due to the quadrant from any power services. (See detail of pole for termination). Interferences if necessary. If Any pavement arias are trenched, the asphalt shall be removed and replaced for the trench width plus 12" additional on each side of the trench 6. Conduit placed In same trench with power conduit must be separated by not less than . per City of Fontana Standard Detail 131. 12" of well packed dirt or 3" of concrete, and have not less than 30" of cover. 4. Contact Underground Service Alert 2 working days before digging at 1-800-642-2444. 7. Approved Plastic Conduit P.V.C. Sch. 40 PTSB 66 PTS 66 2" 5. Bid price is lump sum. No extras will be allowed for underground utilities not being as A.B.S. "D.B." P&C Duct PTS 77 4" shown, hard digging, pavement replacement, etc. PRIVATE PROPERTY PUBLIC STREET ' 8. The Telephone Company reserves the right to ref use to use conduit that deviated fronn plans and specifications. 9. In runs of 400 ft. or over, bends having radii of 80 ft. or less must be concrete encased. In changes of grade 20% (11.3 degrees) or more the conduit must be encased in concrete. J O 30" W a 30" Uj t- X Z � y m W O TELE NE CONDUIT MIN. 12" B KFILL �b �0 2" OR 3" CONCR E 4� POWER CONDUIT 1-89 Area li ht 3 1-5"12Kv Electric to Cypress �2 - 2" Power to pump ' 1 - 2" Telephone to entrance e X17"x30"x1211 r tel. pulibo* / Area light Post top mounted typical mast arm mounted ,, ..� 4 ` r t �ypical 12 Kv U.Q. Electric! v% �. 1: Main Electrical �\ n Switchgear \� ! Ya Secondary Electric <tg 1 4' Sewer clean out Exact location of electric conduits t, \ unknown ' . • Q�=�@tY��� Y DETAIL 0 P41 T ® r Building,; No, .29570 f`f 11501 Cypre yz These plans and specificatlons are the exclusive property of the Agency and shall Exp, 3-31 -91 �" not be used In any manner without prior consent of the Agency. Any reuse of these plans and specifications by the Agency or Others shall be at the Agency's and/or Other's sole risk and without ilabillty to BSI Consultants, Inc. , ■ PREPARE U E SUPERVISION OF: APPROVED BY: _ R EVISIONS R EFERE.N.CES CONSULTANTS, INC. UND RGROUND LEPHONE SERVICE Consultonts to Governmental Aencles� ! APPY03oLogNATURE CEN TER 1906 S. Commercenter E. Ste. 204 Son Bernardino CA 92408 f. DA�p �r'e i scd u�i /iirir�so�c7`Qrr ir�lavlTcd Z9s _ (714} 884 2500 CuDATE � -EXP. 3� g� DESIGN: DRAFT; JURUPA HILL REGIONAL PARK•. CHECK: DATE:..R.C.E. Zs+lZeo EXP. rt• ?t•69 DATE M. N0. ' 12 CITY OE FONTANA - DEPARTMENT OF PUBLIC WORKS ��RA CITY ENGINEER SHEET OF 1mood N. Z C. SCALE: 1 2C