HomeMy WebLinkAbout2108A-14P 0 L E S C H E D U L E
L
C
STANDARD
ARMS
H
LUMINAIRE
PED PUSH
BT.
SIGNAL MOUNTING
PED.
PHASE
SNS
MESSAGE
PLACEMENT
TYPE
HT.
SIG.
LUM.
H.P.S.V.
TYPE
PHASE
QUAD
VEHICLE
PED.
A
B
E 29-5-80
30'
50'
15'
20OW
B
8
W
MAS,MAS, (F)MA S, E SV -1- T
-1-T
2
Mono Ave.
12.5'
3'
H
N 1-A
10'
05
B
2
N
E TV --1-T
ESP -1-T
8
12' *A
3' *A
6
3
08
3
3
02P
2
2
2
2
2
04P
2
2
2
2
2
#14
06P
2
2
08P
(N)=NEW (E)=EXISTING
(F)=FUTURE /CAP TENNON
� SUPPLY NEW MAST ARM MOUNTED S.N.S.(AND HARDWARE) PER
SPECIAL PROVISIONS.
*A EXISTING 1A FOUNDATION BURIED UNDER ASPHALT SIDEWALK.
C O N D U C
T O
R
S C
H
E D
U L
E
AWG
CIRCUIT
1
2
RUN NO.
3 4 5
6
NNN
01
3
3
3
3
3
6
3
02
3
3
3
3
3
3
04
3
3
3
3
3
05
3
3
3
06
6
3
08
3
3
02P
2
2
2
2
2
04P
2
2
2
2
2
#14
06P
2
2
08P
2
2
2
2
02 PPB
1
1
1
1
1
04 PPB
1
1
1
1
1
2
1
06 PPB
2
1
08 PPB
1
1
2
1
PPB COMMON
1
1
1
1
2
1
1
SPARES
3
3
3
3
6
3
3
TOTAL
13
19
21
25
31
37
20
2
I.I.S.N.S.
2
2 1
2
2
LUMINAIRE
2
2
2
2
2
2
#10
SIGNAL COMMON
1
1
1
1
1
1
TOTAL
3
3
3
3
3
3
8
GROUND
1
1
1
1
6
SIGNAL SERVICE
2
2
2
2
01
2
2
02
4
4 N
4
4
1 4
4
03
04
5*
5
DLC
05
2
2
2
2
2
2
06
4
4
07
08
1
6
6
6
s
TOTAL
6
6
12
12
1 18
23
5
CONDUIT
SIZE
2"
3"
3"
3"
3"
I
3"
3"
E
E
E
E
E
E
E
E=EXISTING CONDUIT N=NEW CONDUIT
EXISTING 1.5" C. 1 DI
SEE SH T 12 OF 20
'OR SIGNING & STRIPING
E # 90124E
R 26S i � 0.001 II 0.00�� R JfS
LyJ
EXISTING 1.5" C. 2 DLC, I�� � 7J U �I I J
I I II I EXISTING011
(n
R 26S Ju�. 0' I II I SWK
TREE WELL � Li I � I II 3c, j II
ii I II I
FOOTHILL BOULEVARDI ' I � �� I FH1 , If- I& II
NOTE: ABOVE CONDUCTORS ARE EXISTING UNLESS OTHERWISE /
NOTED ON THE PLAN.
* 5 DLC INCLUDE 3 EXISTING AND 2 NEW DLC EXISTING SIC CONDUIT
TO BE PULLED PER THIS PLAN.
PER 8-343904
(CALTRANS PROJ.)
IT'S THE LAW
DIAL BEFORE
YOU DIGI
1-800-422-4133
" U A Llc,-\
CALL AT LEAST TWO
WORKING DAYS PRIOR
TO EXCAVATING
UNDERGROUND SERVICE ALERT
OF SOUTHMN CAUFaRNiA
BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE
LOCATION OF UNDERGROUND U71UIES BY CONTACTING
U11UTY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
I I I I
R A -I LL``
I LFIII
L
B; 41710 115
EXISTING LOCAL CONTROLLER
Sc J
--- -- -- -- .-� #5, _ 00
D/ PPB
WY- ql I' 1 `� \ � 0 -lilt I � `� 6
06P
a—�
�--
�4 0 6
4 01 4
06P cm-- �1 � I
02_ ► 06 04 1 1 08 05 or
o—02Pb � 0.5
�8
02—�
02P
02 & 06 04 & 08 01 & 05
EXISTING SIC/DET CONDUIT
/ PER 8-343904
(CALTRANS PROD.)
8 t o -----I--------- -1---- - I --y _ I �
SC SCo
�6
06 ,
W
—
''r EXISTIN 3" C1 3 DLC, w r 05 1 .. - _ G
.. I PULL 2� NEW LC1 I ' r
LO
CTOT I I 1
_ 5 DL ) I 1 L< l L _j
C°
w
J LJ I L_J L J�
X° ------ ` ------------------------------
Fr
----- ---------------
-I v)
I c— v 1 t
-------------------
.,
R73-3
0211 _ _ -�
---- ---- I -� I I 4
0002 1 W I I I 1 1 I� ., N �
— — I I
T 1� = - �� -' -- ---- ---- O -
G
IRS L 1 J.� ' <DG7/STREET NAME SIGN
oil I rLn
02 F_T
--------------------- —
04
041 04
I FH
02P �nd-�--- _'--- I - - - - -
TREE WELL / _ 1 A 'Y I a W
LWM O �-=t- �-- _ _ \ �- EXIST R/W
SMH 1 1 I II 6
1
, , L G CASE "E" WC RAMP
III
14' 12' II 01 BY OTHERS
I I I I I I I Sc
EXISTING C&G R 26S �► I I I I I LOOPS ONLY
AND SIDEWALK 1 1 i I I I 1 L t I R 28S
STEADY DEMAND SEQUENCE
TRAFFIC PHASE DIAGRAM
CURB AND GUTTER AND
SIDEWALK,BY OTHERS.
SEWER MAIN Il I j I , 1110
II I I 1rJ II EXISTING SERVICE ENCLOSURE
I I I II 1 1 /I III (j PER 8-343904
p
I I 1 1 II I I I I (I N (CALTRANS PROJ.)
RUN NEW CONDUIT FROM RELOCATED
W II I I i I j 319L I. I I I (1� POWER POLE TO EXISTING STUB -OUT
1 1 11 I I l( I R 26S N AT EXISTING SERVICE ENCLOSURE.
Z j I 30 II 1 341 I I
I �
W R 26S tj 1 I I 3011 I, I I
11 1 1 2, 1 1 5, 1
I II I II I I j I II C/)n
Q I II 1 I -
I I II II I I �I II z
O t► I I I II i --I I
II I I II 1 I SC j I I I� Y
r 1 1 I I 11 3 5U 1 I I, I II �Q
v I II I 1 ZI
Z I II I II 1P I =I III II
Q 111 II II I� �1 1� (j
U
q I I I 1 I I II SC ry
I L_ L_ I I F___
I I I
I II I 8 U 1 w
tr
SEE SHT 12 OF 20
FOR STRIPING
3 cl
01 & 06
02 & 05
CONSTRUCTION NOTES
(DREMOVE AND SALVAGE EXISTING POLE AND HARDWARE FOR RE—USE. REMOVE OLD
CONDUIT AND FOUNDATIONS, BACKFILL WITH CLASS II AGGREGATE BASE MATERIAL
REPAIR AND/OR REPLACE POLES, HARDWARE AND INDICATIONS AS NECESSARY.
INSTALL 1A AS SHOWN ON EXISTING FOUNDATION, BURIED UNDER ASPHALT.
2O INSTALL 3" CONDUIT WITH PULL—ROPE AND 36" PVC SCHEDULE 80 RISER SWEEP
FROM ELECTRICAL SERVICE POINT TO EXISTING STUB—OUT AT SERVICE ENCLOSURE
PER EDISON REQUIRMENTS. PROVIDE TEMPORARY POWER DURING RELOCATION.
Q REMOVE AND SALVAGE OLD TYPE 17 POLE, RELOCATE VEHICLE AND PEDESTRIAN
HEADS AND HARDWARE TO POLE F. REMOVE OLD FOUNDATION AND CONDUIT AS
DIRECTED BY THE STATES REPRESENTATIVE.
(�>INSTALL MAST ARM MOUNTED TRAFFIC SIGN AS NOTED.
GENERAL NOTES
1. TRAFFIC SIGNAL AND LIGHTING INSTALLATION SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARDS AND SPECIFICATIONS, SECTION 86, AND STANDARD PLANS (DATED JULY, 1992).
2. LOCATIONS OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL
DETERMINE THE EXACT LOCATIONS AND VERIFY THE CONDITIONS AT THE JOB SITE. HAND
DIG UNTIL CLEAR OF UTILITIES. PHONE UNDERGROUND SERVICE ALERT AT 800/
422-4133, TWO WORKING DAYS BEFORE DIGGING.
3. ALL WORK, MATERIAL AND EQUIPMENT SHOWN ON THIS PLAN SHALL CONFORM TO THE
REQUIRMENTS OF THE STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARDS
AND SPECIFICATIONS DATED 1992.
4. THE CONTRACTOR SHALL INSTALL SUFFICIENT SENSOR UNITS INTO THE EXISTING CONTROLLER
CABINET TO ACCOMPLISH THE MODIFICATIONS SHOWN ON THE PLAN.
5. THE STATE'S REPRESENTATIVE SHALL BE NOTIFIED 48 HOURS PRIOR TO PERFORMING ANY
WORK THAT MAY CAUSE DAMAGE TO THE EXISTING SIGNAL SYSTEM, SO THAT IMMEDIATE
ADJUSTMENTS OR REPAIRS CAN BE MADE TO MAINTAIN THE SYSTEM IN OPERATION.
6. AT THE COMPLETION OF WORK, IT SHALL BE THE PERMIT APPLICANT'S RESPONSIBILITY TO
PROVIDE ONE (1) REPRODUCIBLE AND FIVE (5) BLUE LINE SETS OF "AS—BUILT" PLANS.
7. ALL VEHICLE INDICATIONS SHALL SHALL BE 12" WITH GLASS LENSES. ALL CONDUIT SHALL
BE RIGID STEEL GALVANIZED TYPE.
8. ALL PULL—BOXES SHALL BE #5 OR PER CALTRANS TRAFFIC MANUAL, SECTION 9, EXCEPT
AS NOTED. ALL CONDUIT SHALL BE 2" EXCEPT AS NOTED.
9. THE EXACT LOCATION OF ALL RELOCATED AND NEW TRAFFIC SIGNAL EQUIPMENT SHALL BE
AS DIRECTED BY THE ENGINEER.
10. ALL LOOPS SHALL BE 6' BY 6' AND CENTERED IN THE LANE OF TRAVEL. EXTEND LOOPS
TWO (2) FEET BEYOND CROSSWALK OR LIMIT LINE.
PLOT DATE: 8-29-94
0
t�
z
J