GENERAL NOTES:
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM
TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTIONi
TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD
SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER
TO DEFINITIONS'AND TERMS IN CITY STANDARD SPECIFICATIONS, DATED
1975.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC
WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY
LIMITS.
3. STATIONING REFERS TO THE CENTERLINES OF S 7 A E E7. 'PROJECT SHEET INDEX
4.
CURB DATA REFERS TO THE FACE OF THE CURB,'
SEWER
5.
ALL EXPOSED CONCRETE SHALL CONFORM'IN GRADE, COLOR AND
STORM DRAIN
TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL- ALSO BE
FINISH TO ALL ADJOINING CURBS AND SIDEWALKS.
PAVING
6.
PAVEMENT SECTIONS &HOWN ARE MINIMUM AND. SUBJECT TO
STRIPING
11,060
REVISION AND APPROVAL OF THE CITY AS REQUIRED BY S O -ILS TEST
17. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
TAKEN AFTER COMPLETION OF ROUGH GRADING.
WITHIN THE CITY LIMITS.
7.
ALL 'UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
3. TERMINATE ALL 4" HOUSE SEWER LATERALS I' OUTSIDE THE LOT
STREETS.
WITH A PLUG. REFER TO DETAIL IN THE SPECIFICATION PACKAGE.
8.
EXISTING UNDERGROUND UTILITIES SHOWN ARE PER A SEARCH OF
35
JOIN TO EXIST. MANHOLE
AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
4. ADEQUATE STAKES SHALL 13E SET BY THE ENGINEER TO ENABLE TH E
COMPUTER POINT
VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD.
20. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
5. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
CONTRACTOR SHALL CALL EACH UTILITY PRIOR TO ANY WORK.
OR POWER POLES. WATER METERS, VALVES, HYDRANTS, IRRIGATION
9.
ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE
21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WIT14
CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR
CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE
(10)
AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER
22. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER.
CONCERNED BEFORE CONSTRUCTION BEGINS.
1
COMPLETION OF PAVING.
6. -AS-BUILT- PLANS SHALL BE PROVIDED TO THE CITY BY THE
COMPACTION OF 90%.
01
24. PRIOR TO CONSTRUCTION OF WATERr, SEWER ANDIOR STORM DRAIN
10.
REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
AND/OR STORM DRAIN LINES WHERE CONNECTIONS WILL OCCUR AND
STANDARD DETAIL 129.
VERIFY THEIR ELEVATION AND LOCATiON. APPROVAL BY THE CITY OF
11.
THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL
OF THEIR LATERALS.
IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATION AND/OR
UTILIT'ES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO
LOCATION AS SHOWN ON PLANS.
9. MANHOLE FRAMES AND COVtRS TO BE CONSTRUCTED BY THE SEWER
GAS, TELEPHONE,/ELECTRICAL, LIGHTING, TELEVISION CABLE,
CONTRACTOR 6- BELOW FINISHED SURFACE GRADE AND UPON -
25. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A
LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER,
SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO
SAME TO FINISHED GRADE.
RECLAIMED WATER, SEWER, STORM DRAINAGE. FLOOD CONTROL
SYSTEM,ETC.
26. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN
12.
AS BUILT DRAWINGS SHALL BE PROVIDED BY THE coN'TRACTOR TO
11. THE SEWER CONTRACTOR'SHALL BE FULLY RESPONSIBLE FOR THE
THE CITY OF FONTANA.
27. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS
13.
CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE
NOT.
ENGINEER Ok---,-A LICENSED LAND SURVEYOR.
SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL
7 BASSIS OF BEARINGS:-
Underground Service Alert
IMMEDIATELY REPORT SAID CONFLICT OR POSSIBLE CONFLICT TO THE
MARK REVISIONS
OWNER'S REPRESENTATIVE.
Call: TOLL FREE
14.
STERILANT REQUIRED UNDER ALL A. C. PAVEMENT.
S890 49'00"W FOR � OF
SHTS. 1-15
SHTS. 1-9
SHTS P2-PI4
SHTS S1 & S2
10. N%J 1 t= %*;1r1ALL t= I-LAU U UN HL I tlt= 1-UHMb ANU HLINt-UHUINU
STEEL HAS BEEN PLACED, INSPECTED AND APPROVED. SEWER NOTES:
w
k
0
A
0
An
2
L
6)p
8
27
SCALE 1" 400, 28
w
_j
291
7
HIGHLAND -AVE.
TORREY AVE.
5 6
25 �E�l 3-7 14 1 11 10
TF 7, ---)Tc 30
8
22 171 1211 311
It
LLi iz LLj
23, 181 13 ii �LLi .321
>
0 V)
<
ca z D
< cy-
w
0 0
24 14 1 33
1-0) 1 2� 13 1
3
16; THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
6
r(7
ITEM' DESCRIPTION
3-4
A
TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL- ALSO BE
THE CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD
GUARDED WHEN EXAMINATION INDICATED HAZARDOUS GROUND
SPECIFICATIONS DATED 1975)AND THE STANDARD SPECIFICATIONS
MOVEMENT MAY BE EXPECTED.
FOR PUBLIC WORKS CONSTRUCTION.
11,060
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA
17. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 16 ABOVE
WITHIN THE CITY LIMITS.
FROM CALIFORNIA STATE i DIVISION OF INDLISTRIAL SAFETY. SEE
INDICATES
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
3. TERMINATE ALL 4" HOUSE SEWER LATERALS I' OUTSIDE THE LOT
SECTION 306-1-1.6.
WITH A PLUG. REFER TO DETAIL IN THE SPECIFICATION PACKAGE.
4
SEWER PLUG
35
JOIN TO EXIST. MANHOLE
1
4. ADEQUATE STAKES SHALL 13E SET BY THE ENGINEER TO ENABLE TH E
COMPUTER POINT
CONTRACTOR TO CONSTRUCT THE WORK To THE PLAN GRADES.
20. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
5. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES.
OR POWER POLES. WATER METERS, VALVES, HYDRANTS, IRRIGATION
BOS, BOP, TOP BOTTOM OF STRUCTURE OR
STRUCTURES, ETC. SHOWN OR NOT SHOWN ON THIS PLAN AND
21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WIT14
WORKING AROUNP THEIR FACILITIES.
CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE
(10)
CONTRACTOR'S RESPONSIBILITY TO- NOTIFY ALL AGENCIES
22. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER.
CONCERNED BEFORE CONSTRUCTION BEGINS.
1
23. BACKFILL. MATERIALS TO HAVE A S. E. OF 30 (MIN) AND MIN.
6. -AS-BUILT- PLANS SHALL BE PROVIDED TO THE CITY BY THE
COMPACTION OF 90%.
9
24. PRIOR TO CONSTRUCTION OF WATERr, SEWER ANDIOR STORM DRAIN
7. ALL SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE
LINES THE CONTRACTOR SHALL EXPOSE THE EXISTING ' SEWER
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
AND/OR STORM DRAIN LINES WHERE CONNECTIONS WILL OCCUR AND
INSTALL 18" TEMPORARY PLUG
VERIFY THEIR ELEVATION AND LOCATiON. APPROVAL BY THE CITY OF
8. SEWER CONTRACTOR SHALL CHISEL"X' IN THE CURB AT THE LOCATION
15
OF THEIR LATERALS.
IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATION AND/OR
E
LOCATION AS SHOWN ON PLANS.
9. MANHOLE FRAMES AND COVtRS TO BE CONSTRUCTED BY THE SEWER
20
CONTRACTOR 6- BELOW FINISHED SURFACE GRADE AND UPON -
25. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A
COMPLETION OF PAVING, THE PAVING CONTRACTOR SHALL RAISE
SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO
SAME TO FINISHED GRADE.
DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER.
10. ALL STATIONING REFERS TO CENTERLINE OF STREET.
26. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN
ACCORDANCE WITH THE CITY STANDARD SPECIFICATION.
11. THE SEWER CONTRACTOR'SHALL BE FULLY RESPONSIBLE FOR THE
. LOCATION AND PROTECTION OF ALL EXISTING UNDERGROUND
3
16; THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5)
LEGEND
FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING
ITEM' DESCRIPTION
SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS.
I ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND
TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL- ALSO BE
THE CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD
GUARDED WHEN EXAMINATION INDICATED HAZARDOUS GROUND
SPECIFICATIONS DATED 1975)AND THE STANDARD SPECIFICATIONS
MOVEMENT MAY BE EXPECTED.
FOR PUBLIC WORKS CONSTRUCTION.
11,060
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA
17. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM
ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 16 ABOVE
WITHIN THE CITY LIMITS.
FROM CALIFORNIA STATE i DIVISION OF INDLISTRIAL SAFETY. SEE
INDICATES
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
3. TERMINATE ALL 4" HOUSE SEWER LATERALS I' OUTSIDE THE LOT
SECTION 306-1-1.6.
WITH A PLUG. REFER TO DETAIL IN THE SPECIFICATION PACKAGE.
18. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL
SEWER PLUG
OF THE CITYS INSPECTOR.
JOIN TO EXIST. MANHOLE
1
4. ADEQUATE STAKES SHALL 13E SET BY THE ENGINEER TO ENABLE TH E
COMPUTER POINT
CONTRACTOR TO CONSTRUCT THE WORK To THE PLAN GRADES.
20. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
5. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES.
OR POWER POLES. WATER METERS, VALVES, HYDRANTS, IRRIGATION
BOS, BOP, TOP BOTTOM OF STRUCTURE OR
STRUCTURES, ETC. SHOWN OR NOT SHOWN ON THIS PLAN AND
21. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WIT14
WORKING AROUNP THEIR FACILITIES.
CONSTRUCTION, SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE
(10)
CONTRACTOR'S RESPONSIBILITY TO- NOTIFY ALL AGENCIES
22. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER.
CONCERNED BEFORE CONSTRUCTION BEGINS.
1
23. BACKFILL. MATERIALS TO HAVE A S. E. OF 30 (MIN) AND MIN.
6. -AS-BUILT- PLANS SHALL BE PROVIDED TO THE CITY BY THE
COMPACTION OF 90%.
CONTRACTOR.
24. PRIOR TO CONSTRUCTION OF WATERr, SEWER ANDIOR STORM DRAIN
7. ALL SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE
LINES THE CONTRACTOR SHALL EXPOSE THE EXISTING ' SEWER
UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
AND/OR STORM DRAIN LINES WHERE CONNECTIONS WILL OCCUR AND
INSTALL 18" TEMPORARY PLUG
VERIFY THEIR ELEVATION AND LOCATiON. APPROVAL BY THE CITY OF
8. SEWER CONTRACTOR SHALL CHISEL"X' IN THE CURB AT THE LOCATION
FONTANA OF A PROPOSED CONNECTION TO A CITY FACILITY DOES NOT
OF THEIR LATERALS.
IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATION AND/OR
E
LOCATION AS SHOWN ON PLANS.
9. MANHOLE FRAMES AND COVtRS TO BE CONSTRUCTED BY THE SEWER
20
CONTRACTOR 6- BELOW FINISHED SURFACE GRADE AND UPON -
25. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A
COMPLETION OF PAVING, THE PAVING CONTRACTOR SHALL RAISE
SYSTEM APPROVED BY THE CITY ENGINEER SHALL BE INSTALLED TO
SAME TO FINISHED GRADE.
DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER.
10. ALL STATIONING REFERS TO CENTERLINE OF STREET.
26. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN
ACCORDANCE WITH THE CITY STANDARD SPECIFICATION.
11. THE SEWER CONTRACTOR'SHALL BE FULLY RESPONSIBLE FOR THE
. LOCATION AND PROTECTION OF ALL EXISTING UNDERGROUND
27. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS
UTILITIES AND STRUCTURES WHETHER SHOWN ON THESE PLANS OR
OR BENC14MARKS NOTED ON THE PLANS OR FOUND DURING CONSTRUCTION.
REMOVAL AND_�REPLA CEMENT SHALL BE DONF By' A REGISTERED CIVIL
NOT.
ENGINEER Ok---,-A LICENSED LAND SURVEYOR.
7 BASSIS OF BEARINGS:-
Underground Service Alert
PRIVATE ENGINEERING NOTE
MARK REVISIONS
Call: TOLL FREE
(NOT REQUIRED BY GOVERNING AGENCY)
S890 49'00"W FOR � OF
C=
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH
HIGHLAND AVE. PER TRACT
1 800
GENERALLY ACCEPTED CONSTRUCTION PRACTICES. CONSTRUCTION
CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE
3348, M.B. 47-14 SAN
422 4133
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THE PROJECT, INCLUDING SAFM OF ALL PERSONS
AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY
BERNARDINO COUNTY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND INDEMNIFY
2
I
TRACT 3348
HIGHLAND HAVEN
INDEX MAP
ZOJECT SITE
(SEE P4&P]4)
VICINITY MAP
,UTILITY N07E
SEWER: CITY OF FONTANA
R/W R/W 8353 SIERRA AVE. FONTANA, CA. 92335
301-001 306-048 TEL. (714) 350-7640
.,,,EX. P'VMT' VARIE34,36'-24' - POWER: SOUTHERN CALIFORNIA EDISON COMPANY
I
I I' MAX. , qawr.HT _7%)C�l DC_r)1A1t-)nr) A\/C' -CY)KITAINIA" t -A 0')_Z_Zf:Z
12. NO'LATERALS SHALL BE PLACED UNDER DRIVEWAYS. FUTURE "PAY L 1MITS EXIST. FUTURE TEL. (714) 357-6191 FRAN �TUART
A.C. 5 A
13. ENGINEER SHALL CHECK OUT ORIGINAL SEWER IMPROVEMENT PLANS 8A CYT A.C. C&G
AND TRANSFER "AS-BUILr INFORMATION TO CITY ACCEPTANCE OF THE GAS: SOUTHERN CALIFORN_IA GAS COMPANY
SEWER SYSTEM. CA. 92335
16231 VALLEY BLVD.- FONTANAP
3 TEL. (714) 889-9711 MR. LOU- WESTFALL
SEWER INVERTS INDICATED IN PROFILE REPRESENT THE GRADE AT SEE NOTE 2
13�
4
14. THE OUTSIDE OF THE MANHOLE. 4 /7
SEE NOTE 1 7 SOUTHERN CALIFORNIA GAS COMPANY
t5. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL VERIFY SEE DETAIL A TRANSMISSION DIVISION 2191 E. BIRCH ST.
WITH THE CITY THAT SURVEY "TIE" PLATS ARE ON RECORD.
BREA, CA. 92621 TEL. (714) 529-2889
SEWER (--�,TRENCH ING NOTES: 8" SEWER TELE. PACIFIC TELEPHONE
AVG. DEPTH=8.5' 3073 ADAMS ST. RM. 120 RIVERSIDE, CA. 92504
1. SELECTED NATIVE SOIL BACKFILL COMPACTED TO 90% R/W TO FLOWLINE TEL. (714) 999-5639
fMINJ R.C. WITH A MIN. S.E.=30. BACKFILL MAY CONTAIN R/W
STONES RANGING IN SIZE UP TO 6" IN DIAMETER. 308 -ops 30'-Osf WATER: SAN GABRIEL VALLEY WATER COMPANY -
2. SAME AS NOTE I EXCEPT -SOIL SHALL BE COMPACTED TO EX. PVMT VARIES 368-24" 11142 GAREY AVE. P.O. BOX 6010 EL MONTE, CA.91734
95% (MIN.) R.C. AND STONE SIZE SHALL BE A MAX. OF 3" 1
1. TEL. (818) 448-6183 MR. -FRANK LOGUIDICE
ie"MAX.!
IN DiA. (12" LAYER). P9( LIMITS FUTURE
A.c.
3. REMOVE EXIST. A.C. PAV'T AS REQUIRED. REPLACE A.C. PAV'T 14 R
QUANTITY OF A.C. FOR TRENCH RE,_A,.TR (ESTIMATED),
PER THE PHASE- I SPECIFICATION PACKAGE TO THE GRADES FUTURE SEE NOTE 3
INDICATED ON PAGES P2-PI4 OF THESE SEWER PLANS*4"MIN. A.C.. FOR A.C.,�7�kE-
A.C. EXIST 4j* FULL DEPTH A.C. ON COMPACTED NATIVE 3ww1frt kT*,0NS
i
4. FOR DEPTHS OF COVER (FROM F.S. TOT.Qp)-GREATER THAN PLACEMENT C. NOTE: (SEWER ONLYLPAVEMENT REMOVAL AND PROJEC , PX TAL A.C. QUANTITIES
10' INSTALL 1/4" TO 3/4" GRAVEL BEDDING. FOR DEPTH LESS f� ARE INCLUDED IN T14E PROPOSAL BID SHEET.
THAN 10' USE SAME MATERIAL AS IN BEDDING ZONE.
THE LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN
SAWCU I SAWCUT ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST
3/4 1 3 4 SEE NOTE 2 4 1 3/4 :/4 '3/4 OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE
I
P I -PE BELL O.D. PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL ' PRECAUTIONARY MEASURES TO PRO -
SEE NOTE I SEE NOTE I TECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON
41 THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO,
I" MAX. SI S.D. THESE LINES OR STRUCTURES. 11110"��Mjjj
11T
r
2 SELECTED TRENCH -C I
W;t NATIVE SEE DETAIL A
MATER1 PRIVATE ENGINEER'S NOTE:
m 0 0- 0
< �- COMIPAC 18" 21" SEWER
> Ins= THE PRIVATE ENGINEER SIGNIN,G JHESE PLANS IS RESPONSIBLE FOR ASSURING THE
MIN. AVG. DEPTH=14" ACCURACY AND ACCEPTABILITY OF THE WORK HEREON. IN TH� EVENT OF. DISCREPANCIES
WITH A MIR
SE 30 i__�01" MIN SEE NOTE 4 TO FLOWILINE ARISING DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR
SEWER TRENCHING CEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY
12"MAK DETERMINING AN AC
DETAIL A AND BEDDING DETAIL
THE CITY. ( THIS NOTE REQUIRED ON ALL PLANS.
N.T.S.
ENGINEER
AppRovAL DATE ApCRy DATE
PROVAL IDDf7DA m KInC_Q TL_jf:_ nIOC70TIOKI nF
QUANTITIES SHOWN ARE FOR PERMIT PURPOSES ONLY."THE CONTRACTOR
IS RESPONSIBLE FOR DETERMINING HIS OWN QUANTITY TAKE -OFFS. LINEAL
FOOTAGE OF PIPING DOES NOT INCLUDE SECTION OF MAIN WITH WYE ASSEMBLY
ATTACHED.
CONSTRUCTION NOTES & QUANTIT"Y ESTIMATE
LEGEND
No.
ITEM' DESCRIPTION
OTY.
INDICATES
SEWER MANHOLE
.01
INSTALL 8 DIA EXTRA STRENGTH V.C.P. SEWER MAIN
-0
L.F.
INDICATES
HOUSE LATERAL
11,060
L.F.
INDICATES
SEWER MAIN
28
EA.
INDICATES
SEWER TERMINUS
MANHOLE
CONSTRUCT REINFORCED CONCRETE ENCASEMENT
PER DETAIL ON SHEET 14
INDICATES
SEWER PLUG
JOIN TO EXIST. MANHOLE
1
INDICATES
COMPUTER POINT
No.
9
REPRESENTS
CENTERLINE OF
MANHOLE
BOS, BOP, TOP BOTTOM OF STRUCTURE OR
PIPE, TOP OF PIPE
ZOJECT SITE
(SEE P4&P]4)
VICINITY MAP
,UTILITY N07E
SEWER: CITY OF FONTANA
R/W R/W 8353 SIERRA AVE. FONTANA, CA. 92335
301-001 306-048 TEL. (714) 350-7640
.,,,EX. P'VMT' VARIE34,36'-24' - POWER: SOUTHERN CALIFORNIA EDISON COMPANY
I
I I' MAX. , qawr.HT _7%)C�l DC_r)1A1t-)nr) A\/C' -CY)KITAINIA" t -A 0')_Z_Zf:Z
12. NO'LATERALS SHALL BE PLACED UNDER DRIVEWAYS. FUTURE "PAY L 1MITS EXIST. FUTURE TEL. (714) 357-6191 FRAN �TUART
A.C. 5 A
13. ENGINEER SHALL CHECK OUT ORIGINAL SEWER IMPROVEMENT PLANS 8A CYT A.C. C&G
AND TRANSFER "AS-BUILr INFORMATION TO CITY ACCEPTANCE OF THE GAS: SOUTHERN CALIFORN_IA GAS COMPANY
SEWER SYSTEM. CA. 92335
16231 VALLEY BLVD.- FONTANAP
3 TEL. (714) 889-9711 MR. LOU- WESTFALL
SEWER INVERTS INDICATED IN PROFILE REPRESENT THE GRADE AT SEE NOTE 2
13�
4
14. THE OUTSIDE OF THE MANHOLE. 4 /7
SEE NOTE 1 7 SOUTHERN CALIFORNIA GAS COMPANY
t5. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL VERIFY SEE DETAIL A TRANSMISSION DIVISION 2191 E. BIRCH ST.
WITH THE CITY THAT SURVEY "TIE" PLATS ARE ON RECORD.
BREA, CA. 92621 TEL. (714) 529-2889
SEWER (--�,TRENCH ING NOTES: 8" SEWER TELE. PACIFIC TELEPHONE
AVG. DEPTH=8.5' 3073 ADAMS ST. RM. 120 RIVERSIDE, CA. 92504
1. SELECTED NATIVE SOIL BACKFILL COMPACTED TO 90% R/W TO FLOWLINE TEL. (714) 999-5639
fMINJ R.C. WITH A MIN. S.E.=30. BACKFILL MAY CONTAIN R/W
STONES RANGING IN SIZE UP TO 6" IN DIAMETER. 308 -ops 30'-Osf WATER: SAN GABRIEL VALLEY WATER COMPANY -
2. SAME AS NOTE I EXCEPT -SOIL SHALL BE COMPACTED TO EX. PVMT VARIES 368-24" 11142 GAREY AVE. P.O. BOX 6010 EL MONTE, CA.91734
95% (MIN.) R.C. AND STONE SIZE SHALL BE A MAX. OF 3" 1
1. TEL. (818) 448-6183 MR. -FRANK LOGUIDICE
ie"MAX.!
IN DiA. (12" LAYER). P9( LIMITS FUTURE
A.c.
3. REMOVE EXIST. A.C. PAV'T AS REQUIRED. REPLACE A.C. PAV'T 14 R
QUANTITY OF A.C. FOR TRENCH RE,_A,.TR (ESTIMATED),
PER THE PHASE- I SPECIFICATION PACKAGE TO THE GRADES FUTURE SEE NOTE 3
INDICATED ON PAGES P2-PI4 OF THESE SEWER PLANS*4"MIN. A.C.. FOR A.C.,�7�kE-
A.C. EXIST 4j* FULL DEPTH A.C. ON COMPACTED NATIVE 3ww1frt kT*,0NS
i
4. FOR DEPTHS OF COVER (FROM F.S. TOT.Qp)-GREATER THAN PLACEMENT C. NOTE: (SEWER ONLYLPAVEMENT REMOVAL AND PROJEC , PX TAL A.C. QUANTITIES
10' INSTALL 1/4" TO 3/4" GRAVEL BEDDING. FOR DEPTH LESS f� ARE INCLUDED IN T14E PROPOSAL BID SHEET.
THAN 10' USE SAME MATERIAL AS IN BEDDING ZONE.
THE LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN
SAWCU I SAWCUT ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST
3/4 1 3 4 SEE NOTE 2 4 1 3/4 :/4 '3/4 OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE
I
P I -PE BELL O.D. PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL ' PRECAUTIONARY MEASURES TO PRO -
SEE NOTE I SEE NOTE I TECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON
41 THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO,
I" MAX. SI S.D. THESE LINES OR STRUCTURES. 11110"��Mjjj
11T
r
2 SELECTED TRENCH -C I
W;t NATIVE SEE DETAIL A
MATER1 PRIVATE ENGINEER'S NOTE:
m 0 0- 0
< �- COMIPAC 18" 21" SEWER
> Ins= THE PRIVATE ENGINEER SIGNIN,G JHESE PLANS IS RESPONSIBLE FOR ASSURING THE
MIN. AVG. DEPTH=14" ACCURACY AND ACCEPTABILITY OF THE WORK HEREON. IN TH� EVENT OF. DISCREPANCIES
WITH A MIR
SE 30 i__�01" MIN SEE NOTE 4 TO FLOWILINE ARISING DURING CONSTRUCTION, THE PRIVATE ENGINEER SHALL BE RESPONSIBLE FOR
SEWER TRENCHING CEPTABLE SOLUTION AND REVISING THE PLANS FOR APPROVAL BY
12"MAK DETERMINING AN AC
DETAIL A AND BEDDING DETAIL
THE CITY. ( THIS NOTE REQUIRED ON ALL PLANS.
N.T.S.
ENGINEER
AppRovAL DATE ApCRy DATE
PROVAL IDDf7DA m KInC_Q TL_jf:_ nIOC70TIOKI nF
QUANTITIES SHOWN ARE FOR PERMIT PURPOSES ONLY."THE CONTRACTOR
IS RESPONSIBLE FOR DETERMINING HIS OWN QUANTITY TAKE -OFFS. LINEAL
FOOTAGE OF PIPING DOES NOT INCLUDE SECTION OF MAIN WITH WYE ASSEMBLY
ATTACHED.
CONSTRUCTION NOTES & QUANTIT"Y ESTIMATE
No.
ITEM' DESCRIPTION
OTY.
UNIT
Q)
.01
INSTALL 8 DIA EXTRA STRENGTH V.C.P. SEWER MAIN
9850
L.F.
Designed by:
S.S.
INSTALL 47 DIA. HOUSE LATERAL PER MOD. STD. DWG. 125
11,060
L.F.
CONSTRUCT SEWER MANHOLE (4" DIA.)
PER STD. DTL. 109, 112 J�- 1 14
28
EA.
INSTALL LATERAL WYE (8"x4")
281
EA.
CONSTRUCT REINFORCED CONCRETE ENCASEMENT
PER DETAIL ON SHEET 14
90
L. F.
JOIN TO EXIST. MANHOLE
1
EA.
CONSTRUCT SEWER MANHOLE (5' DIA,) PER STD. DTL.
109.,114 & MODIFIED STD. DTL. 112. SEE SPECIFICATIONS.
9
EA.
INSTALL LATERAL WYE (21 $* x47)
34
EA.
INSTALL 21 STUB AND PLUG
1
EA.
(10)
INSTALL 21" DIA. EXTRA STRENGTH V.C.P. SEWER MAIN
19-25
L. F.
INSTALL 5' STUB & PLUG.
1
EA.
IINSTALL 18" EXTRA --STRENGTH V.C.P. SEWER MAIN.'
885
L.F.-
INSTALL 18" TEMPORARY PLUG
I
EA.
CONSTRUCT BARRICADE PER CITY OF FONTANA STD.DWG-N0.1!8_
2
E
INSTALL LATERAL WYE [IlBx4l
20
EA.
IR m 0 E�- 7
3
A4.
I I I
m r_ U m U AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL
TWO WORKING DAYS BEFORE YOU DIG LIABILIT'Y, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY
ARISING FROM THE SOLE NEGLIGENCE Or DESIGN PROFESSIONAL. A.0 _0� ReCoR 1) FO
-PATA
MARK REVISIONS ENGINEER DATE Ap cay DATE
APPRMAL PROVAL
C==1 =7 == J.F.DAVIDSON ASSOCIATES,INC
EE51EEE3 EE3 EEF,
=E3E3 EF=�EiF ENGINEERING PLANNING SURVEYING LANDSCAPE ARCHITECTURE
-564 COUNTRY CLUB DR. #400-6
El P.O.BOX 493 03426 TENTH STREET E] 77 E] 27349. JEFFERSON ST. # 115
RIVERSIDE CA 92501 RIVERSIDE, CA 92502 PALM DESERT CA 92260 TEMECULA, CA 92390
(714)686-0844 (714)683�0209 (619)360-3780 (714)676-7710
FAX 714-686-5954 FAX 714-6B6-5807 FAX 619-360-3789 FAX 714-699-1981
UIIY
UI- IUNIANA UALIIUNNIA
F) I I al I r \A/n ED I/ Q
1 V V NZ7 -T-7T-7,_.) LI/ I-- I I \I I IV I L__ I N I
immy W"S/I m s R.C.E. 35458
D a _14
Exp. te:
Drawn by:
Scale:
SE-WER IM OVEMEW PLANS
AS SHOWN
TITLESHEET Date: ,
DEC., 1-991
-
BENCHMARK: FOUND 2" BRASS DISK IN TOP OF OLD GAS STATION ISLAND AT
S.E. CORNER OF CITRUS AND HIGHLAND STAMPED S.B. Co. SURV
.M. No. 8-14 1970 ELEV. = 1510.91
Designed by:
S.S.
Date:
Checked by:
JA
Approved: Dr. No.: -
C[TY ENG I IN . E -ER RCE 25126 -2104