HomeMy WebLinkAbout2089-14HYDROVISOR SERVING MULTIPLE VALVES IN A COMMON ZONE TYPE REQUIRES WIRING BACK TO CONTROLLER --FINISH GRADE WIRING: FINISH GRADE UNION GENERAL NOTES HV TENSIOMETER WIRING AND INSTALLATION TO YELLOW LEAD FROM HV TENSIOMETER LATERAL LINE OLSON 12,OUTLET EMITTER OVERRIDE ALL VALVES SERVING SIMILAR -ZONES TO MASTER VALVE TERMINAL ON CONTROLLER (24 TO 30 VAC ONLY) MAIN LINE PLASTIC VALVE BOX WITH DISTRIBUTION TUBE ALL MAIN LINE PIPING AND CONTROL WIRES UNDER PAVING SHALL BE INSTALLED IN SEPARATE RED LEAD FROM HV TENSIOMETER TO LOCKING LID MARKED '1GV11., SLEEVES. MAI� LINE SLEEVE SIZE SHALL 13E A MINIMUM OF TWICE (2X) THE DIAMETER OF THE PIPE To VALVE COMMON TERMINAL(S) ON or SLEEVE TYPICAL CONTROLLER CONTROLLER TUBING. STAKE BE SLEEVED. CONTROL WIRE SLEEVES SHALL BE OF SUFFICIENT SIZE FOR THE REQUIRED NUMBER OF COMMON GREEN LEAD FROM HV TENSIOMETER WIRES UNDER PAVING. TO SHARED COMMON WIRE BETWEEN MASTER VALVE SIMILAR ZONE REMOTE CONTROL C . .......... VALVES(RCV's) STATIONS 4VAC ..... . 4 E ALL LATERAL LINE PIPING UNDER PAVING SHALL BE PVC SCHEDULE 40 PIPE AND SHALL BE INSTALLED . ...... .... or 2 3 4 -71' ETC. V d k PRIOR TO PAVING. Of. BUG CAP C 01P 00 %1ATE VA V 1 PIPE SIZES SHALL CONFORM TO THOSE SHOWN ON THE DRAWINGS. NO SUBSTITUTIONS OF SMALLER FINISH GRADE YELLOW YELLOW Xr., PIPE SIZES SHALL BE PERMITTED, BUT SUBSTITUTIONS OF LARGER SIZES MAY BE APPROVED. ALL DAMAGED AND REJECTED PIPE SHALL BE REMOVED FROM THE SITE AT THE TIME OF SAID REJECTION. RED ONTROL RE .. . .. .. ... Of FINAL LOCATION OF THE AUTOMATIC CONTROLLER SHALL BE APPROVED BY OWNER'S AUTHORIZED N HV HV ... ... WIRE ............. GREEN GREEN ADV IN R SER (as required) REPRESENTATIVE. P77 I or PVC Sch. 40 COUPLING, 120 VAC ELECTRICAL POWER SOURCE AT CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. THE 2 IRRIGATION CONTRACTOR SHALL MAKE THE FINAL CONNECTION FROM THE ELECTRICAL SOURCE TO THE min. PVC MAINLINE CONTROLLER 2.2%-- -------- V RC RCV RCV RCV CLEAN BACKFILL NOTE; —PVC Sch. 80 RISER ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR I TO FINISH GRADE UNLESS OTHERWISE SPECIFIED. 000F 0 'E 1 -All plastic piping to be snaked In trenches. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS AND VALVES FOR cm 2.Bundle & tape wiring at 10' Intervals. ONE CUBIC FOOT OF PVC MALE ADAPTOR PVC Sch. 40 TEE OR ELL OPTIMUM COVERAGE WITH MINIMAL OVERSPRAY ONTO WALKS, STREETS, WALLS, ETC. THIS SHALL SPECIFICATION LEGEND 3/4" CRUSHED ROCK (2 REQUIRED) INCLUDE REGULATING THE PRESSURE AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING PRESSURE UNIT SPEC. SOLID STATE TENSIOMETER 3 -Tie a loose 2011 loop In wiring at change of 1 U UNIT LENGTH IN INCHES (7",16", OR (S) SPECIAL, I.E. -36") direction greater than 309. Untie all loops 2" X 4" REDWOOD BLOCKING PVC LATERAL FOR EACH SYSTEM ROOT STRESS RA I NGE IN CENTIBARS (CB) AS EITA 8-12, OR 40-M NOTE: Install valve box so that the top of cover _� i after all connections have been made. HV 7 20-30 4 -See irrigation specifications for backfill and Is 2" above finish grade In ground cover THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC., SHOWN WITHIN PAVED AREAS IS FOR INSTALLATION DETAIL areas and 1/2" in turf areas. DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE. THE (3) 116 UF WIRES OR compaction requirements. TOP VIEW LARGER FROM EACH CONTRACTOR -SHALL LOCATE ALL VALVES IN SHRUB AREAS. NO SCALE HV LEAD. PROVIDE 2' SPECIFICATIONS: UNITS ARE TO BE SOLID STATE giv) R WIRE EXPANSION IN 5. MINIMUM OF 4!'BETWEEN SLEEVING IS REQUIRED BOX AND APPROVED MAINTENANCE FREE TENSIOMETERS. THEY ARE T Y WIRE SPLICE AT ALL IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE BE PRESET BY MANUFACTURER TO ALLOW CONNECTIONS. IRRIGATION ONLY WHEN SOIL MATRIC POTENTIAL TO CONTROLLER DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, STRUCTURES AND UTILITIES. THE IRRIGATION (ROOT STRESS) RISES ABOVE THE SPECIFIED PRESET VALUE AS EXPRESSED IN CENTIBARS (CB). UNITS CONTRACTOR SHALL REPAIR OR REPLACE ALL ITEMS DAMAGED BY HIS WORK. HE SHALL COORDINATE WILL AUTOMATICALLY CLOSE THE VALVE COMMON FINISH GRADE APPROVED ROUND PLASTIC HIS WORK WITH OTHER CONTRACTORS FOR THE LOCATION AND INSTALLATION OF PIPE SLEEVES AND POWER CIRCUIT TO ALLOW CONTROLLER ABOVE HV TO BE Box WITH BOLT -DOWN PROGRAMMED IRRIGATION WHEN' SOIL MATRIC ELEVATED APPROX. I"' COVF MODIFIED FOR HV LATERALS THROUGH WALLS, UNDER ROADWAYS AND PAVING, ETC. (WC ffi POTENTIAL IS AT OR ABOVETHE SPECIFIED RANGE. _910 OR EQUAL). TRENCHING GATE VALVE EMITTER UNITS SHALL BE OF A TYPE WHICH IS NOT DAMAGED AN BY FREEZING NOR AFFECTED BY VARIATIONS IN SOIL DOWN TO 2/3 OF PARTICLE SIZE. SOIL DENSITY OR SALINITY. ROOT ZONE DEPTH DO NOT WILLFULLY INSTALL THE PRINK SYSTEM WN N E DRAWIN WHEN I IS OBVIOUS - -0 // IN THE FIELD THAT UNKNOWN OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA NOTE: HV TENSIOMETERS ARE TO BE LOCATED IN THE ZONE IRRIGATED LAST IN THE CONTROLLERS SEOUENCE FOR ALL RCV9 SHARING THE SAME SECTION VIEW DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH COMMON WIRE. NO SCALE TO BAILEY LINE- SIZE 'Y' STRAINER OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNERS AUTHORIZED CONTROLLER Finish grade Plastic valve box with locking REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE IRRIGATION 6" PEA GRAVEL FINISH GRADE (with 100 mesh min. monel screen) CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. cover. mark "R.C.V." and station UVR-PVC Sch. 40 PIPE BRASS RISER ENCLOSURE HOUSING number on cover ALL SPRINKLER EQUIPMENT NOT OTHERWISE DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER anchor at 10' O.C. (TYPICAL) 24#vX24vvX36 99 MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. ,HYDROV I SOR NOTES —UVR-PVC Sch.40 -------- REFER TO SPECIFICATIONS FOR ADDITIONAL DETAILED INFORMATION. "Snap-tite" 1. THE HYDROVISOR MUST NOT BE INSTALLED IN A LOOSE COUPLING electrical connector ADV (ANTI -DRAIN VALVES) UNITS AS SHOWN IN THE DETAILS ARE FOR TYPICAL INSTALLATION ONLY, OVERSIZED HOLE. USE PROBE EXACT SIZE AS HYDROVISOR Control valve AND MAY NOT BE REQUIRED ON ALL HEADS. PRIOR TO INSTALLATION THE CONTRACTOR SHALL VERIFY OR BACKFILL THE EXCAVATION AROUND THE HYDROVISOR OF.41. WITH THE ON-SITEGRADES. IF THERE IS AN ELEVATION DIFFERENCE OF 24- OR MORE BETWEEN THE UNTIL FIRM. P.V.C. male HIGHEST HEAD AND LOWEST HEAD ON A SYSTEM, THE ADVS SHALL BE INSTALLED PER THE DETAIL. 2. INSTALL ON THE CONTOUR, ACROSS THE SLOPE IN APPROXIMATE LOCATIONS SHOWN ON DRAWINGS. aclaptor THE CONTRACTOR SHALL VERIFY THE STATIC PRESSURE TO BE AS STATED ON THE SYSTEM ------------- 3. INSTALL 1/3 OF THE WAY DOWN SLOPES; IN APPROXIMATE (2 required) REQUIREMENTS. CENTER OF SECTIONS ON REPRESENTATIVE GROUND, NO 3 REBAR 4" CONC. NEITHER'HUMPS NOR HOLES. L-40 BASE 1219min. BRASS /�-411 $ch. 40, 4. CONNECT TO VALVES WITH *14, _UF, UL, 600V WIRE; SHOULD THE STATIC PRESSURE EXCEED 20% OF STATED PRESSURE, INSTALL A'WILKINS'600 SERIES UNION SLF61N PRESSURE REGULATING VALVE (IN A SEPARATE VALVE BOX) DIRECTLY DOWN STREAM OF THE MAKE ALL SPLICES WITH EPDXY FILLED OR HEAT SHRINK SPLICE KITS. SYSTEM REQUIREMENTS. SHO JLD THE STATIC PRESSURE B LESS AN THE STATED PRESSURE, 5, INSTALL ALL OF THE ABOVE PRODUCTS ACCORDING TO UVR-PVC Sch. 40 PIPE BRA55 CLLQ NOTIFY THE ARCHITECT IMMEDIATELY. MANUFACTURERS RECOMMENDATIONS: A A A A A A A a A A A A WATER CONSERVATION SYSTEMS, INC. -cal) A 06 A a a (typi ALL STATED GALLONAGES IN VALVE CALL -OUTS ARE ROUNDED UP TO NEAREST GALLON. A A A A A A A A A A A A A A A A 141 SOUTH S PR ING STREET 00 0100000 J, 0.1 r 0 0.100 0 A a *% '%'-A A IN *1 1% A A A A A 1% A . . . . ............... FINISH GRADE AA 4A A A A A d6 A '6 01 CLAREMONT, CA 9 1711 (714) 621-5805 ............. ONCRETE THRUST BLOC A A A.%A.%A.%AAAAA A A A A A A A A A A THE SYSTEM IS DESIGNED FOR THE MINIMUM OPERATING PRESSURE -AS SHOWN AT EACH POINT OF ........... .......... CONNECTION. THE MAXIMUM DEMAND OF GALLONS PER MINUTE IS AS SPECIFIED. THE IRRIGATION 0 00 CONTRACTOR SHALL VERIFY THE AVAILABLE WATER PRESSURE ON THE SITE PRIOR TO THE START OF MALE ADAPTER PVC MAIN LINE INSTALLATION. HYDROVISOIR LOCAVMM SHOWN ON PLAN NO 3 REBAR One cubic foot END VIEW Install to a depth 2491 MAIN LINE FROM METER TO SYSTEM 18" MIN. 3/4" crushed rock 00 P.V.C. sch 40 ALL LOW VOLTAGE WIRE FROM CONTROLLER TO VALVES SHALL BE SOLID COPPER UF #14 DIRECT UPPER CASE NUMBER DENOTES SCHEDULE. DEPTH BURIAL TYPE. USE BLACK INSULATED WIRE FOR CONTROL AND WHITE FOR COMMON. INSTALL IN A r ipple COMMON TRENCH WITH PRESSURE MAINLINE PIPIN3% WHERE POSSIBLE. BUNDLE AND TAPE TO PIPE AT A LOWER CASE LETTER 1p�NOTES CONTROLLER. 2411X241'X36" ENCLOSURE BY: P.V.C. mainlin 10 FOOT INTERVALS. LE. MUER MFG. CO. (714) 822-5100 2" X 4" REDWOOD BLOCKING P.V.C. tee, -*MOISTURE SENSORS SHALL BE TURNED OVER CONTACT FOR SHOP DRAWINGS. PROVIDE A MINIMUM OF 18" COVER OVER ALL PRESSURE MAINLINE PIPE AND 12" MIN. COVER OVER ALL TO THE CITY WHEN DISCONNECTED. NON -PRESSURE LATERAL LINE. ALL PIPE UNDER PAVED AREAS IS TO BE INSTALLED IN PVC SCH. 40 SLEEVE WITH 36" MIN. COVER. SLEEVE LOCATIONS TO BE AS SHOWN ON PLANS AND INSTALLED PER DETAIL. R� MOISTURE SENSOR 0 TRENCHING ON GRADE BACKFLOW PREVENTER CONTROL VALVE ALL QUICK COUPLER VALVES ARE TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHENEVER REDUCED PRESSURE PRINCIPAL WPE POSSIBLE AND WITHIN 18"OF THE HARDSCAPE. ALL QUICK COUPLER VALVES LOCATED IN TURF AREAS SHALL BE INSTALLED IN 8" DIA. GREEN PLASTIC VALVE BOX. ALL THREADED PIPE CONNECTIONS MADE TO SLIP -%JOINT PVC PIPE SHALL BE MADE WITH A PVC THREADED COUPLING. ALL THREADED ADAPTERS AND 10" ROUND VALVE BOX COUPLINGS ARE TO BE'DURA'DEEP SOCKET TYPE. STAINLESS STEEL PEDESTAL MOUNT SATELLITE UNIT MFG. B STENCIL'O.C'ON LID FINISH GRADE INSTALL ALL SPRAY HEADS WITH NOZZLES OF THE APPROPRIATE DEGREE OF RADIUS FOR THE AREA TO BE COVERED. ADJUST ALL NOZZLES TO ,,PACIFIC TECHNICAL SERVICES ELIMINATE SPRAYING WATER ON BUILDINGS AND HARDSCAPE. ADJUST ALL 1116 W. BRADFORD CIRCLE VALVES FLOW CONTROLS To PROVIDE OPTIMUM PERFORMANCE. CORONA, CA 91720 ICK COUPLING VALVE'O ALL LATERAL LINE PIPE ACROSS CONCRETE DRAIN BENCHES SHALL BE (714)737-4010 (install 2" above grade INSTALLED IN A GALVANIZED SLEEVE. The Dike Partnership in shrub areas) IALL SHRUB SPRAYS'ON RISER ARE FOR INSTALLATION ALONG WALLS AND Landscape Architecture CONCRETE BASE eee., FENCES, AND FOR INTERIOR PLANTING AREAS ONLY. Urban Design Site Planning 3c4pe 24"X24"X4" min. 01 to One Venture, Suite 100 'ONE (1) CUBIC FT. 3/4 100� Irvine, CaJifornia 92718 6-1 101.1� 714 753 1779 : :: CRUSHED ROCK - Woodward Dike rin 0 1� Fax 714 753 1479 fill FINISH GRADE elop ir,#1330 17 a 141 �D BRASS RISER (Datel' X 2 BRASS STREET ELLS OF CA0 IA. CONDUIT FOR BRASS NIPP L�. 1m13 TROL WIRES lVecolld IJAWMSS too IS1 . 1 2 DIA. MASTER - 2" X 4" PVC TEE COMMUNC.,WTION CABLE REDWOOD 120 VAC POWER CONDUIT (1) INCOMING BLOCKING -- Note: (1) OUTGOING NTANA, CALIFORNIA All wire to be installed as per local code. PUBLIC WORKS DEPARTMENT - E RASS ELL PVC MAIN LINE provide commercial padlock and two (2) keys to,,owner. NOTE: INSTALL 6" FROM NEAREST ADJACENT PAVED AREA. DRAWN BY SCALE: PVC Sch. 80 NIPPLE FROM PVC TEEI LAN SCAPE ENOWS. I CITY. TO BRASS ELL DESIGNED. BY REVISIONS OAT E DATE LIC APPROVAL I APPROVAL IRP11 TION -')ATE- N 0 CHECKED BY 13 _VE L4A C V ETC. 6 -DET' 0 SATELLITE QUICK COUPLING VALVE JOB NO. N _/0_; e� DR. NO. SHT. NO. .90023� APP VED CIFY ENGINEER R.C.E,25.6' 14 F 3.5 �7