UTILITY REQUIREMENTS
The Contractor Is advised of the existence of the utility notification service provided by
UNDERGROUND SERVICE ALERT (USA). USA member utilities will provide the Contractor with
the precise locations of their substructures In the construction area when the Contractor gives at
least 48 hours notice to the Underground Service Alert by calling 1/800/422-4133.
The Contractor shall notify the following agencies at least 48 hours In advance of
excavating around any of their structures. The utility companies listed below can be contacted as
indicated.
DI AKI I 1=rZF=K1r) -
1. Fontana Water Company *
Local Telephone: (714) 822-2201
2. Pacific Bell (Riverside Eng. Div.)
Local Telephone: (714) 359-2520
3. Southern California Edison Co. *
Local Telephone: (714) 820-5598 (So. part of City)
(714) 820-5537 (No. part of City
4. Southern California Gas Co.
Local Telephone: (714) 793-2686
5. Fontana Public Works Department (Sewers)
Local Telephone: (714) 350-7610 (Engineering)
(714) 350-6760 (Maint. yard)
6. Fontana Union Water Company *
Local Telephone: (714) 822-9199
7. Marygold Mutual Water Company
Local Telephone: (714) 877-0516
8. Comcast Cable
Local Telephone: (714) 350-1337
9. Chino Basin Municipal Water District
Local Telephone: (714) 987-1712
* USA Member Utility, Phone 1-800-422-4133
SCREENED BACKGROUND - Indicates previous construction and
& DASHED LINE7 existing facilities. This information is
for reference only.
BOLD INKED LINES - Indicates new construction for this interconnect
project.
TRAFFIC SIGNAL INTERCONNECT
FROM UPLAND AVE, TO VALLEY BLVD,
THESE PLA NSA ND SPECIFICATIONS ARE THE
EXCL USI VE PROPER T Y OF THE A GENC Y A ND
SHALL NOT BE USED IN ANY MANNER WITHOUT
PRIOR CONSEN T OF THE A GENC Y. A N Y REUSE
OF THESE PL A NS AND SPECIFICA TIONS BY THE
A GENC Y OR 0 THERS SHA L L BE A T THE
A GENC YS A ND IOR 0 THER S SOL E RISK A ND
W1 THOU T L 1A SIL / T Y TO BSI CONSUL TA N 7S, INC.
MAP
PROJECT LOCATIOU r%1
NO S C A L� V5
SIERRA AVENUE INTERCONNECT
CONTROLLER AND CABINET RECAP*
SIERRA AVENUE LOCATIONS SHEET CONTROLLER/CABINET
1. Upland Avenue Sheet 2
Existing KMC-2000, add telemetry
equipment In existing cabinet.
2. Spring Street Sheet 3
Existing KMC-4000, add telemetry
equipment In existing cabinet.
3. Arrow Boulevard Sheet 4
Salvage existing KMC-8000 and type "PN
cabinet to Marygold. Install new ASC -
8000, type "P" cabinet and KMC-1 0000.
4. Valencia Avenue Sheet 5
Existing KMC-2000, add telemetry
equipment In existing cabinet.
5. Orange Way Sheet 6
Existing KMC-2000, add telemetry
equipment In existing cabinet.
6. Merrill Avenue Sheet 9
Remove existing KMC-2000 and type "G11
cabinet. Reinstall KMC-2000 In new type
"P" cabinet on new foundation. Add
telemetry equipment.
7. Randall Avenue Sheet 7
Existing KMC-2000, add telemetry
equipment In existing cabinet.
3. San Bernardino Ave. Sheet 10
Salvage existing'KMC-2000 and remove
Type "Pu cabinet. Install KMC-8000
salvaged from Valley Blvd. In new type
"P" cabinet. Add telemetry equipment.
Marygold Avenue Sheet - 11
Remove D-2000. Install KMC-8000 and
type "PN cabinet salvaged from Arrow
Boulevard on modified foundation. Add
telemetry equipment.
0. Kaiser Pedestrian Sheet 12
Salvage existing non -expandable KMC.
2000. Install KMC-2000 salvaged from
San Bernardino In new type NMN cabinet.
Add telemetry equipment.
1 Valley Boulevard Sheet 8
Salvage existing KMC-8000. Install new
ASC -8000 In existing cabinet.
Provided for quick reference only.
See plan sheets and Special Provisions
for detail.
IT'S THE LAWl
DIAL BEFORE
YOU DIGI
1-800-422-4133
LV
CALL AT LEAST TWO
WORKING DAYS PRIOR
TO EXCAVATING
UNDERGROUND SERVICE ALERT
OF SMM*:RN CALIFMIA
BEFORE EXCAVATINGo THE CONTRACTOR SHALL VERIFY THE
LOCATION OF UNDERGROUND UTILIIES BY CONTACTING
UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
GENERAL DESCRIPTION
This project Is to construct an Interconnected traffic signal system on Sierra Avenue utilizing both
new and modified existing equipment. Interconnection will be accomplished with new telephone
line services and by cabling �xlstlng Interconnect conduit runs. Specific details are contained
hereon and In the Special Provisions.
GENERAL NOTES
1. General and miscellaneous construction to be in accordance with the "Standard
Specifications for Public Works Construction" (the Green Book).
2. Traffic signal construction shall be in accordance with Caltrans Standard Plans and
Standard Specifications (both dated January 1988), as shown hereon and per the Special
Provisions.
3. Locate all substructures prior to construction. Hand dig as necessary to protect existing
underground utilities. See "Utility Requirements" hereon.
4. Obta in approval for exact equipment location prior to placement. Loop detectors shall be
6' x 6' with 10' between adjacent loops in the same lane, unless otherwise shown. Center
loops in the traveled portion of the lane, and extend front loops 2' into the limit line or
crosswalk.
5. All new conduit is 1.5" except as noted. Conduit to be bored in paved, sidewalk and
landscaped areas. All new pull boxes are #5 except as noted.
6. Coordinate Telephone line interconnect service with Carol VerBrugge, Pacific Telephone
at 714-359-2520.
7. Provide all new equipment and modify existing equipment and perform necessary
connections, testing and adjustments to provide a functional Interconnected traffic signal
system. Update all intersection and system control equipment to the latest Software version
available from Econolite Control Products.
8. Provide, install and setup Dell System 310 computer system In Fontana City Hall East
P.nnex at 8335 Sierra Avenue, with Econolite Zone Monitor IV software per the 'Special
Provisions and as directed.
CONSTRUCTION NOTES
Constru,,*O-Ilon note s appear on the plan sheet to which they apply.
t J
1 31 1
N,
C t