Loading...
HomeMy WebLinkAbout1913-1Department o I Hnn nnn Ini , , ffb WO uu_ J1 L ffm fnq4 ru—u Uri, U I HL 31001 1 'LL '®r-1 T-7 7 �77 I! fF L L IDLT-D 77 ........ t7-1 77 _7 t __ __ i General Notes, 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND THE CITY OF �ONTANA PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS DATED 1975, AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION. I 2. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES, ALL PERMITS SHALL BE OBTAINED AND PAID BY CONTRACTOR. 3. ALL PIPES OR STRUCTURES OF ANY KIND AND TELEPHONE, OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THESE PLANS AND LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION SHALL BE RELOCATED AT NO COST TO THE CITY OF FONTANA. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES CONCERNED. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT BEFORE THE START OF CONSTRUCTION AT 1-800-422-4133, AND SHALL POT HOLE AND VERIFY EXISTING LOCATION OF UTILITIES AS NECESSARY TO IDENTIFY LOCATION. 4. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN 5' IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING OR SHIELDING SYSTEM. TRENCHES LESS THAN 5' IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. PUBLIC SAFETY SHALL BE CONSISTENTLY GUARDED AT ALL TIMES, AND NON—COMPLIANCE WITH THIS NOTE SHALL BE CONSIDERED THE CONTRACTOR'S RESPONSIBILITY. 5. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 4 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, SECTION 306-1.1.6. 6. CONTRACTOR SHALL FILLET BOTTOM OF MANHOLES AND OTHER STRUCTURES WITH CLASS "A" CONCRETE SO AS TO ALWAYS PROVIDE A SMOOTH TRANSITION ON FLOWLINES BETWEEN INLETS AND OUTLETS. 7. EXISTING UTILITIES SHALL BE MAINTAINED IN PLACE BY THE CONTRACTOR UNLESS OTHERWISE NOTED. CON— TRACTOR SHALL BACKFILL WITH SAND A MINIMUM OF 24" AROUND UTILITY LINES. 8. ALL PIPE TO BE INSTALLED WITH BEDDING AND D—LOAD AS SPECIFIED. SEE PROJECT SPECIFICATIONS FOR COMPLETE DETAILS. 9. COMPACTION OF BACKFILL SHALL BE VERIFIED BY THE CONTRACTOR AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS PRIOR TO THE, PLACEMENT OF THE PERMANENT PAVEMENT. SEE PROJECT SPECIFICATIONS FOR COMPLETE DETAILS. 10.PRIOR TO PLACEMENT OF PERMANENT PAVING, EXISTING PAVEMENT SHALL BE CUT TO A NEAT STRAIGHT LINE. PAVEMENT CRACKED ADJACENT TO THE TRENCH SHALL BE REMOVED. 11. ALL �DGES OF EXISTING PAVEMENT BEING JOINED AND SURFACE BEING OVERLAID SHALL RECEIVE A TACK COAT OF ASPHALT EMULSION WHICH SHALL BE APPLIED AFTER WATER CLEANING. 12.TRENCHES OF 300 FEET OR MORE TO BE PAVED WITH A SELF—PROPELLED PAVING MACHINE. 13.TRENCH FAILURES SHALL BE REPAIRED BY THE CONTRACTOR IMMEDIATELY. UPON FAILURE OF THE CONTRAC— TOR TO PROMPTLY COMPLY, AND UNDER ORDER OF THE CITY ENGINEER, TRENCH FAILURES SHALL BE REPAIR— ED AT THE CONTRACTOR'S SOLE EXPENSE. 14.111N ALL PIPE CROSSINGS CONTRACTOR SHALL COMPACT BACKFILL BY LAYERS, AT OPTIMUM MOISTURE CONTE,NT. R E V I S...# 1 0 N S I I-Z&-911(5LH I C,0N67-1<U(2T101\1 M�VIOION!5 Peg 0TY MAA;ZK-dFt2 R E F E R E N C E S APPYD T T Tr_ E Ontario Private Engineers Note To Contractorl The Existence And Location Of Any Underground Utility Pipes, Conduits Or Structures Shown On These Plans Are Obtained By A Search Of The Available Records. To The Best Of Our Knowledge There No Existing Utilities Except As Shown On These Plans. The Contractor Is Required To Take Due Precautionary Measures To Protect The Utility Lines Shown On These Drawings. The Contractor Further Assumes All Liability And Responsibility For The Utility Pipes, Conduits Or Structures Shown Or Not Shown On These Drawings. The Contractor Agrees That He Shall Assume Sole And Complete Responsibility For Job Site Conditions During The Course Of Construction Of This Project, Including Safety Of All Persons And Property, That This Requirement Shall Apply Continuously And Not Be Limited To Normal Working Hours, And That The Contractor Shall Defend Indemnify And Hold The City Of Fontana, The Owner And The Engineer Harmless From Any And All Liability, Real Or Alleged, In Connection With The Performance Of Work On This Project. Excepting For Liability Arising From The Sole Negligence Of The Owner Or The Engineer. Utility Contacts, Comcast Cablevision Fontana Water Company City Of Fontana 1257 West Brooks 16803 Spring Street Engineering Services Ontario, California 91761 Fontana, California 92335 8353 Sierra Avenue (714) 350-2344 (714) 822-2201 Fontana, California 92335 (714) 350-7610 Southern California Edison Company Pacific Bell Telephone Company 300 North Pepper Avenue 3939 Coronado Street Rialto, California 92376 Anaheim, California 92807 (714) 820-5598 (714) 999-5514 Southern California Gas Company Note: See Project Specifications 1981 West Lugonia Avenue For Complete Utility Listing. Redlands, California 92474 (714) 884-9411 Note: Call U.S.A. 48 Hours Before Excavating At 1-800-422-4133 San Bernardino /. Grand Terrace ------------- Project - L, Location. Location Map Scale, None ?,rjf ESS/4 .2 31673 Exp. Dat&,/zi CIVIL, pr _00 PREPARED UNDER THE SUPERVISION OF: CONSULTANTS, I NC. P-3LANE- N.'P,;�A�06EN Consultants to Governmental Agencies fikiuf 6) f/o/149 1906 S. Commercenter E Ste.204 Son Elemdrdino, Co. 92408 — (714) 884-2500 R. C. E. -3/6 73 EXP. /2, 31-92, DATE DE$tONq t, DRAFT: R.S.- Black Dave B. C1115CIks DATE* Lynn Parker — 2/20/90 nV APPROV'ED BY: RECORD DRAWING 10-7--91- R.0 * Em'', EXR DATrE CITY ENGINEER Key Map Scale, None Beach Marks, RR SPIKE ON PP # 674320E AT THE INTERSECTION OF JURUPA AVE. AND MULBERRY AVE. ELEV. 918-40 Notes, These Plans And Specification Are The Exclusive Property Of The A ? ency And Shall Not Be Used In Any Manner Without Prior Consent 0 The Agency. Any Reuse Of These Plans And Specifications By The Agenvi Or Others Shall Be At ThesA encVs And/Or Others Sole Risk Apd thout Liability To B.S.11. Con ullants, Inc. Santa Ana Of Fontana, California Public Works Department Rose Drawn By. Dave B. Traced By. Avenue Ch e"'cked By. D.L.Parker Approved: ity Englneerzof 0-t57.xI shtA�' Avenue V C 4-1 L_ :3 C > < > < > 0 > < > > < -C M E 0 :3 I- 4-1 0 Village Drive 'N, East Jurupa Avenue Cypress Avenue Citrus Project Elm Avenue Avenue Location RECORD DRAWING 10-7--91- R.0 * Em'', EXR DATrE CITY ENGINEER Key Map Scale, None Beach Marks, RR SPIKE ON PP # 674320E AT THE INTERSECTION OF JURUPA AVE. AND MULBERRY AVE. ELEV. 918-40 Notes, These Plans And Specification Are The Exclusive Property Of The A ? ency And Shall Not Be Used In Any Manner Without Prior Consent 0 The Agency. Any Reuse Of These Plans And Specifications By The Agenvi Or Others Shall Be At ThesA encVs And/Or Others Sole Risk Apd thout Liability To B.S.11. Con ullants, Inc. Clity Of Fontana, California Public Works Department Drawn By. Dave B. Traced By. Scale: STORM DRAIN IMPROVEWOTS' N oted NATURE CENTER -Date.,, 2/20/90-/,� Ch e"'cked By. D.L.Parker Approved: ity Englneerzof 0-t57.xI shtA�' V