Loading...
HomeMy WebLinkAbout1889-1FONTANA EWER 111PROVEANENT '^1- 10 FONTANA CALIFORNIA t. H. Ri Rj I I 40 41 SLOVER y AVE. TRACT NOS, 14243ml 14243m2 < 1.1 C> 0- 0 V) JURUPA AVE, I I V ILLACE DR. E ST LAa *DREAST 'C8 PROJECT SITE 0 '-s SAN BERNARDINO CO. JURUPA �� V" REGIONAL RIVERSIDE CO. # JURUPA HILLS PARK VICINITY MAP N. T. S. px 1?a 00, 4��' "n. .'q 3 0 .0 -A OR 85: 0, r POPLAn 2 c> -C' f4 z 23 co 3 19 4 W 5 22 cn� N8o, 32, - ------------ rwm 2. ca 65-35# fXIST. 9"ye-p 5L 21 !'4 -C� - 10 Go Cni V: co 9 N 8 6 �9 20 cy) 7 2 NO. 5 4 5 C=; co 7 19 2 IpA "W M) Uj ftr-" U11) C> 12 Tol A 13 18 W '_ - 1 8 X: ::�_ C" 14 cn CIV 23 /\c 15 16 X. W 17 17 0 Ln 9 7> C.0 L 21 20 19 18 1_1 N LO 22 C.0- 16 W R/ N80' 32,05. W 10 1500 E 140. 101 00. -F- 48. 19t 171 N85 -21,510E. 86'27'09*W 48.98' E 49. OS E LL, 15 N89' 41 24 tm 54. 57' 49. 02' 49. F --j f D -F 01 CIO CO. _44- 14 00- 12 7 LOT I 13 D VICINITY MAP 20/1A9-�:);:) "-NB4* 39'20 SCALE: 1"= 100' 54. 1� 0 100 200 300 400 GRAPHIC SCALE PRIVATE ENGINEER'S NOTE The private engineer signing these plans is responsible for assuring the accuracy and acceptability of the work hereon. In the event of discrepancies arising during construction, the private engineer shall be responsible for determining an acceptable solution and revising the plans for approval by -the City. PRIVATE ENGINEERS NOTICE TO CONTRACTOR 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS, AND THOSE SHOWN OF THE RECORDS EXAMINED ARE SHOWN WITH THEIR APPROXIMATE LOCATION AND EXTENT. 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE NATURE OF EXISTING GROUND AND/OR THE FINISHED GRADE IN THE VICINITY OF THE PROPOSED CONSTRUCTION AREA IMMEDIATELY PRIOR TO CONSTRUCTION. 3. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 4. THE CONTRACTOR SHALL UNCOVER ALL UTILITIES THAT HE MAY BE JOINING, CROSSING OR PARALLELING PRIOR TO ANY CONSTRUCTION TO VERIFY BOTH HORIZONTAL AND VERTICAL LOCATIONS, ANY CONFLICT OR DISCREPANCY SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO CONSTRUCTION, OTHERWISE THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR ANY COSTS OF RELOCATION OR ADDITIONAL COSTS OF CONSTRUCTION. WATER L I NE LOCAT I ON THE WATER LINE LOCATIONS AS SHOWN HEREON ARE BASED ON OUR UNDERSTANDING OF THE INTENDED LOCATIONS ONLY. CONTRACTOR SHOULD VERIFY ALL WATER SYSTEM COMPONENTS PER PLANS BY FONTANA WATER COMPANY DATED PLfiN CONSTRUCTION NOTES AND QUANTITY ESTIMATES NO. I TEM TR 14243-1 TR 14243-2 TOTAL UNIT INSTALL STANDARD MANHOLE PER CITY OF FONTANA STANDARD DETAIL 112. 2 3 5 E. A. 20 INSTALL TERMINAL MANHOLE PER CITY OF FONTANA STD. 112 & 114 CASE VI 0� I I E. A. INSTALL 8" VITRIFIED CLAY PIPE PER CITY OF FONTANA STANDARDS AND SPECIFICATIONS. 769 777 1546 L. F. G) INSTALL 4" SEWER LATERAL PER CITY OF FONTANA STANDARD DETAIL 125. 764 894 1658 L. F. INSTALL TEMPORARY CLEANOUT PER CITY OF FONTANA STANDARD DETAIL 128 I I EA. 06 - I I I 6" M IN. 6" M I N. 10" MAX. 10" MAX. SELECTED NATIVE SOIL r1" MAX. SIZE COMPACTED TO 90% C'j LL1 CL C> AK � �n 1/4" TO 3/4 ROCK BEDDING TYPICAL BEDDING FOR 8 it VCP 10 1 OR DEEPER N. T. S. AS -BUILT NOTES These as -built drawings have been prepared from redlined prints prepared by and provided to us by Century Homes Communities on 7-6-93. While as -built information is believed to be reliable, Musser Engineering Consultants did not inspect or field verify lateral or manhole locations. We represent gDly that this is a true representation of the redlines provided. 6"MIN. 6"MIN. 10"MAX. 10"MAX, I" MAX, S17E SELECTED "Wo. NATIVE BEDDING COMPACTED TO 90% C'j U_j 0 - CL C; TYPICAL BEDDING FOR 8 1$ VCP LESS THAN 10' DEEP )FIESSIo Legend 5' n'ly/s'ly - the lateral is located 5' northerly of the southerly property line prod as measured along the curb face. -co NO. RCE 40982 EXP. 3-31-91 (VI (IF 0 N. T. S. GENERAL CONSTRUCT I ON NOTES: 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 5. EXISTING UNDERGROUND UTILITIES ARE AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE Ac'rUAL LOCATION AND ELEVATION IN THE FIELD. 6. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306--l. 1.6. 8. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 9. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES. CONTRACTOR SHALL NOTIFY THE ENGINEER 48 -HOURS PRIOR TO THE ANTICIPATED START OF CONSTRUCTION. 10. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, STREET CENTERLINE MONUMENTS, OR BENCH MARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT. 12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 13. ALL 4" HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% M INIMUM GRADE UNLESSOTHERWISE APPROVED BYTHE CITYENGINEER. 14. TERMINATE ALL 4" HOUSE SEWER LATERALS 3' INSIDE THE LOT WITH A PLUG. SHOULD A PUBLIC UTILITIES EASEMENT LIE CONTIGUOUS TO THE STREET RIGHT OF WAY, THE LATERALS SHALL EXTEND ACROSS THE EASEMENT AND TERMINATE 3' INSIDE THE LOT MEASURED FROM THE UTILITY EASEMENT LINE. 15. AN "X" SHALL BE PLACED ON THE CURB OVER LOCATIONS OF SEWE_R LATERALS BY THE SEWER CONTRACTOR. 16. IT SHALL BETHE CONTRACTOR'S RESPONSIBILITYTO VERIFY THE HORIZONTAL LOCATION AND VERTICAL ELEVATIONS OF ALL UTILrrY CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWE-R. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIORTO CONSTRUCT I ON. 17. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION SHALL BE RELOCATED BY OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS. 18. PRIOR TO CONSTRUCTION OF THE WATER, SEWER, AND/OR STORMI)RAIN LINES, THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER, SE-WER, AND/OR STORM DRAIN LINES WHERE CONNECTIONS WILL OCCUR AND VERIFY THEIR ELEVATIONS AND LOCATION. APPROVAL BY THE CITY OF FONTANA OF A PROPOSED CONNECTION TO A CITY FACILITY DOES NOT IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATION AND/OIR LOCATION AS SHOWN ON THE PLANS. 19. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LimrrED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY: CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CALIFORNIA 92335 TELEPHONE (714)350-7610 SO. CALIF. GAS COMPANY -DISTRIBUTION FACILITIES 570 4TH STREET, P.O. BOX 6226 SAN BERNARDINO, CALIFORNIA 92408 TELEPHONE( 714) 884-9411 OR( 800) 422-4133 U. S. A. SO. CALIF. GAS COMPANY -TRANSMISSION DEPARTMENT 2191 BIRCH STREET BREA, CALIFORNIA 92621 TELEPHONE( 714) 529-2889 OR( 800) 422-4133 U. S. A. SOUTHERN CALIFORNIA EDISON COMPANY 1351 E. FRANCIS AVENUE, P.O. BOX 513 ONTARIO, CALIFORNIA 92621 TELEPHONE( 714) 947 -2996 -UNDERGROUND POWER (714)875 -5100 -TRANSMISSION (213)637 -1233 -PIPELINES, OR (800)422-4133 U.S.A. GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE POMONA, CALIFORNIA 91766 TELEPHONE (213)357-2257 OR (800)422-4133 U.S.A. SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT 825 EAST THIRD STREET SAN BERNARDINO, CALIFORNIA 92408 TELEPHONE( 714) 383-1665 PACIFIC TELEPHONE & TELEGRAPH COMPANY 3073 ADAMS STREET f RIVERSIDE, CALIFORNIA 92504 TELEPHONE (714)359-2585 OR (800)422-4133 U.S.A. 11 AS BU I LT "