HomeMy WebLinkAbout1870-9bEXISTING RCP 41LMAIN LINE EXISTING RC BOX STORM DRAIN STORM DRAIN EXISTING RC BOX C. MAIN LINE STORM DRAIN LA 450 00 EXISTING RCP STORM DRAIN y 7 P LAN /00 CHIP PIPE TO SURFACE OF mm X4.1 CONCRETE AND ROUND EDGES CONE. I1 PIPE MORTAR PPE PDUNDISTURBED EARTH hy SUPPORT PIPEACROSS WITH 265K9C-14 Mpa (450-C-2000) CONCRETE BACKFILL. SEE NOTE 3 SUR ACE BEARING SECTION B - B SECTION C - C CASE I PLAIN CONCRETE PIPE D = 600 mm (240) MAX. 100 mm (40) MIN. E z VARIES TO SUIT E CONDITIONS o o CLASS C MORTAR E d cV = 2 200 mm (81) MAX. P_ CASE 2 SECTION SADDLE CONNECTION AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED TA THEANDARDS PIPE CONNECTIONS TO STANDARD PLAN ST PUBLIC WORKS STANDARDS INC., GREENBOO�OMMITTEE EXISTING STORM DRAINS METRIC 335-1 REV. 1"6 SHEET 1 OF 3 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION C MAIN LINE RCP OR REiWORCED�-MONOLI TH IC ARCH. SEE NOTE 2 1. J SEE NOTE 10 H I H D I 3• MIN. ill N � I W N J F... Q co a:- V H J W+ W 0 F - Z Z O W W O W Y W 2 N 44 w W N Q m ROUND j EDGE I TO 3•R I c4 It LATERAL/ ✓/ CONNECTOR PIPE N I I �oj STA. POINT CONNECTOR PIP I ( SEE NOTE 3 I I ( 3• MIN. C` I STA. PUINT LATERAL SEE NOTE 3 PLAN SPUR 03 ® 18. OC TIE BARS REINFORCING STEEL ( 4 ®6S OC 30 MIN. � I� SPRING /� I iv 5• A LINE ROUND) II (EDGES•5 � ELEV. R E BARS ELEV. S / ®3' OC .. F BARS 95 ® 3. OC UNDISTURBED CONCRETE CRADLE. EARTH H I H 420-C-2000. SEE NOTE 9 SECTION Z -Z SECTION M -M __-G BARS •4 O 6. OC 03 m 18. OC TIE BARS E AND F BARS •503. OC. SEE NOTE 6 E TABLE OF VALUES FOR T B T (INCHES) (INCHES) 12 5 15 5 Is 5 21 5 24 51/2 27 5 1/2 30 6 33 1 6 1/2 36 6 1/2 39 7 BARS G BARS LOS ANGELES COUNTY DEPARTMENT OF PUBL'I C WORKS 38 JUNCTION STRUCTURE N O . 2 STANDARD PLAN APPROVED �. . G,' S/31/C992 3031-0 �� DIRECTOR OF PUBLIC WORKS DATE SHEET I OF 2 SUPERSEDES FLOOD STD. DWG. NO. 2-DI12 N JO • I /' � asp eoi°' .� a 100 1 ( CLASS C MORTAR 0 0 PLAN CSP OR RCP moo ' RCP RCP -' CSP OR RCP UNDISTURBED EARTH SUPPORT PIPE ACROSS TRENCH WITH 265 Kq-C-14 MPa (450-C-20001 CONCRETE BACKFILL. SEE NOTE 3 MAN F �- CORRUGATED STEEL BAND CONNECTOR (CS BAND CONNECTOR NOT NEEDED FOR RCP) AL I BURN OR CUT PIPE TO SURFACE OF CONCRETE AND ROUND EDGES OF RCP SECTION E - E OPTIONAL RECTANGULAR COLLAR I OD DIA. OF C S P MIN. GAGE 375 mm (15.) - 525 mm (211 16 MINIMUM BEARING 600 mm (24•) 14 00 SURFACE - OD/2 SECTIONF - F CAS E 3 RCP OR CSP D = 600 mm (244) MAX. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 335 - 1 SHEET 2 OF 3 PIPE CONNECTIONS TO EXISTINGMETRIC STORM DRAINS NOTES I. JUNCTION STRUCTURE NO. 2 SHALL BE USED WHEN THE OUTSIDE DIAMETER OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE MAIN LINE: OR WHEN THE INSIDE DIAMETER B OF THE LATERAL IS GREATER THAN 24". B SHALL NOT EXCEED 3/4 D OR 39'. 2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN, D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A REINFORCED MONOLITHIC ARCH. 3. STATIONS SHOWN ON THE PROJECT DRAWINGS APPLY AT THE INTERSECTION OF CENTER LINES OF MAIN LINE AND LATERAL, EXCEPT THAT STATIONS FOR CATCH BASIN CONNECTOR PIPES APPLY AT THE INSIDE WALL OF MAIN LINE. 4. VALUES. FOR A. B. C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATION S SHALL BE SHOWN ONLY WHEN REQUIRED PER NOTE 5. 5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY. b. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY IF A STUB I.S TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION OF AN INLET PIPE. c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET PINE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE CATCH BASIN OR GRADE BREAK IN LINE. 6.. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN RADIALLY IF ANGLE A IS GREATER THAN 450, B IS LESS THAN OR EQUAL TO 24" AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN 1/2 D: OTHERWISE. STANDARD PLAT! 3042 SHALL BE USED. 7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE. 8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF THE SPUR. 9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE CONCRETE ENCASEMENT SHALL EXTEND 12" ABOVE THE TOP OF THE MAIN LINE AND TO THE LIMITS OF THE CRADLE. IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE OPPOSITE INLET MAY BE OMITTED. 10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 40, AND BE PLACED 1 1/2" CLEAR FROM CONCRETE SURFACES, UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS THAN J DISTANCE FROM CENTER LINE WITH J=7D/12 + 6". 11. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF THE SPUR. LOS ANGELES COUNTY DEPARTMENT OF PUBLIC WORKS STANDARD PLAN JUNCTION STRUCTURE NO. 2 3031-0 SHEET 2 OF 2 GENERAL NOTE I. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. NOTES CASE I AND CASE 3 I. OUTSIDE DIAMETER OF THE CONNECTOR PIPE SHALL NOT BE GREATER THAN 1/2 THE INSIDE DIAMETER OF THE RCP MAIN LINE. 2. INSIDE DIAMETER D OF THE CONNECTOR PIPE SHALL NOT BE GREATER THAN 600 mm (24"). 3. THE MINIMUM OPENING INTO THE EXISTING STORM DRAIN SHALL BE THE OUTSIDE DIAMETER OF THE CONNECTING PIPE PLUS 30 mm (I"). THE CONCRETE BACKFILL SUPPORTING THE CONNECTING PIPE MAY BE OMITTED IF THE PIPE IS LAID ON UNDISTURBED EARTH TO STORM DRAIN WALL. 4. ALL CSP AND FITTINGS SHALL BE GALVANIZED. BAND CONNECTORS MAY BE 2 GAGES LIGHTER THAN THE PIPE. BUT WITH A MINIMUM GAGE OF 16. THEY SHALL BE CONNECTED AT THE ENDS BY ANGLES HAVING MINIMUM DIMENSIONS OF 50 mm x 50 mm x 5 mm (2"x2"x3/16") AND 140 mm -(5 1/20) BOLTS. 5. WHEN JOINING A RCP CONNECTOR PIPE TO A CSP CONNECTOR PIPE. THE INSIDE DIAMETER D OF THE CSP SHALL BE AT LEAST EQUAL TO BUT NOT MORE THAN 75 mm (3") GREATER THAN THAT OF THE RCP. 6. CONNECTOR PIPES SHALL BE NOT MORE THAN 1.5 m (5') ABOVE THE INVERT. 7. CONNECTOR PIPES SHALL ENTER MAIN LINE RCP RADIALLY. 8. WHEN CONNECTING TO A RCB, STANDARD PLAN 333 SHALL BE USED IF THE TOP OF THE CONNECTOR PIPE IS LESS THAN 300 mm (121 BELOW THE SOFFIT OF THE RCB OR THE FLOW LINE OF THE PIPE IS LESS THAN 330 mm (130) ABOVE THE FLOOR OF THE RCB AT THE INSIDE FACE. CASE 2 9. SADDLE. CONNECTIONS SHALL BE USED WHEN CONNECTING TO PIPES 525mm (21") OR LESS IN DIAMETER WITHOUT THE USE OF JUNCTION STRUCTURES OR PRECAST Y BRANCHES. 10. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN PIPE. SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTING PIPE. 11. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE SADDLE PIPE, 12. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASE I AND CASE 3. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 335 - 1 SHEET 3 OF 3 PIPE CONNECTIONS TO EXISTINGMETRIC STORM DRAINS //00//O/