HomeMy WebLinkAbout1863-71 "334
BACKFILL UNLESS OTHERWISE
SPECIFIED
UNDISTURBED EARTH---�
1/12 O.D. MIN.
BEDDING A
BEDDING
OPTIONAL. TRENCH SIDE SLOPE FOR
DEEP TRENCHES OR UNSTABLE SOIL
� SPRINGLfNE
BEDDING B
�—OPTIONAL EXCAVATION UNE
11 1/4 0.0.— SLURRY (1 1/2 SACKS
P.C./C.Y. OPTION OF CONTRACTOR
1/ 12 O.D. ( C MIN.)
SHAPE BEDDING AS SHOWN TO
SUPPORT R.C.P. (SEE NOTE 10)
NOT TO SCALE
.NOTES;
1 BEDDING A SHALL BE COMPOSED OF SAND, NO.3 OR NOA CRUSHED ROCK OR
GRAVEL PER STANDARD SPECIFICATIONS OR OTHER GRANULAR MATERIAL AS MAY
BE SPECIFIED OR APPROVED BY THE ENGINEER.
2 BEDDING B SHALL BE COMPOSED OF SAND OR OTHER GRANULAR MATERIAL AS
MAY BE SPECIFIED OR APPROVED BY THE SOILS ENGINEER
3 BEDDING B SHALL BE COMPACTED TO A RELATNE COMPACTION OF NOT LESS
THAN 90 PERCENT UNLESS OTHERWISE SPECIFIED
4 BEDDING B SHALL BE PLACED IN TWO OR MORE LIFTS FOR O.D. GREATER
THAN 60 INCHES.
S BACKFILL SHALL BE PER SOILS REPORT
S WHERE THE COVER IS 8 FEET OR LESS, -VF MUST !!E GREATER THAN OR
EQUAL TO 6 INCHES. WHERE THE COVER IS GREATER THAN 8 FLET, -VIP MUST
BE BETWEEN 6 AND 10 INCHES INCLUSIVE FOR PIPES UP TO AND INCLUDING
96 INCHES IN DIAMETER. FOR PIPES OVER 96 INCHES IN DIAMETER, -VM'
MUST BE BETWEEN 6 AND 12 INCHES INCLUSIVE.
70V SHALL INCLUDE THE THICKNESS OF ANY SHORING.
8 SHORING SHAM. BE A MINIMUM OF 6 INCHES FROM THE PIPE AT SPRPMURE.
9 AN IMPROVED BEDDING METHOD SHALL BE SUBMITTED TO THE ENGINEER FOR
ANY OW" OTHER THAN THAT PERMITTED IN NOTE 6.
10 THE TRENCH BOTTOM SHALL BE SHAPED AS SHOWN, OR THE CONTRACTOR. AT
HIS OPTION MAY CHOOSE NOT TO SCREED BEDDING "A- IN WHICH CASE, THE
PIPE SHALL BE BACKFILLED TO A DEPTH OF 1/4 O.D. WITH TRENCH BACKFILL
SLURRY AT HIS EXPENSE
11 CONCRETE BACKFILL WHERE SPECIFIED ON THE PROJECT DRAWINGS. MALL BE
420—C-2000 CONCRETE POURED WALL TO WALL OF TRENCH FROM TOP OF
BEDDING A TO A MINIMUM DEPTH OF C OVER PIPE.
NO.1212 CAST IRON
PARKWAY GRATE
WT. -29#
NO.1212 BODY
TRAFFIC GRATE
WT.- 33#
NO.1212 BO[
WT.- 435#
3/4 � 1�
COVER MAY BE PRIME
^HINTED OR GALVANIZED
,S REQ.
r 1 1/2
®w
12 BEDDING A 9 B FOR P.V.C. STORM DRAM PIPE
SHALL BE CLASS I - ANGULAR 114" TO 1 112"
GRADED STONE.
3/8 DIA. REBAR ROD
EACH CORNER
NOT
FLOOR OF CATCH BASIN TO BE A MIN.
OF 6" THICK. FLOOR SHALL BE
STEEL — TROWELED FINISH & SLOPED
FROM ALL DIRECTIONS TO OUTLET.
1 ' Go. 33 ' t'
05 Z MGS. EAeN FACE
(TYP.) PLACE /"CLEAR
FROM D.D. OF P/ rE
4
1
PLACE /P" NORM ROCKS
SL � PE PRD TEC T/
04P /e"
v
N I
4 AD "EARlN FACE
;04. 2 =D" WATER FACE'
L�
4 7 fAfAfEP L3AR (EACH FALE
404 iF /B" &ARTN FACE
#4 V / 2" WATER FACE'
O.�lDya d' ash. v_'V�
NOTE
ALL STRL CrL1&E SPE/NFDPLEMENT'
SHALL BE 44 BAPS P /2 "L/NL ESS
OTHE.PW/SE NOTED
)9r6/1 SEM /" STORM
TDRANV EASEMENT
Z
P
N. g9' 2 (,49" W �t
N
W
48 0 .G.P, p L "�
NB9 ° 25'07"
PUBLIC
STORM
4) DRAIN i
P
9 P/PE Cllpw nArA
�g -d = 450DO "DD
R= 9D'
L= 70.to5'
7-= 37.2B'
DETAIL
�2�of E SS/Oy
CIO
CD RCE #31737 m
EXP. 12-3192
crm
F OF cp��Fo�
v
�
o/
SECTIOR A -A
CORPS OF ENGINEERS
STANDARD JUNCTION
STRUCTURE — ofFif
'E
SLD VER
/OG t "3.26 !E NAMVC - _SrA.
V /D4- t 57. ZZ i! STREET -STA .
PLAN VIEW _—
S.B.C.F.C.D. LINE "A"
FILE N0. S.P. 183-B SCALE i I" = 20'
BENCH MARK REVISIONS:
ELEVATIONS SHOWN HEREON ARE BASED NO. DESCRIPTION
ON SAN BERNARDINO COUNTY SURVEYOR A5 BUILT
DATUM, BENCH MARK 1-18:
P.K. NAIL SET IN CONCRETE BASE OF
SOUTHERN CALIFORNIA EDISON TOWER NO.
2/1 NO.2 VISTA ETIWANDA, 100 FT. WEST
OF ETIWANDA AVE., AND 300 FT. SOUTH
OF AIRPORT DRIVE.
ELEVATION = 969.848
_j
STONEWORK
STONE SHALL COMPLY WITH SUBSECTION 200-1.6, STONE FOR RIP–RAP, EXCEPT COBBLESTONES SHALL NOT
BE USED, ALL STONES SHALL BE ANGULAR, EACH PIECE HAVING ITS GREATEST DIMENSIONS NOT GREATER
THAN THREE TIMES ITS LEAST DIMENSIONS,
STONE SHALL COMPLY WITH TESTS SPECIFIED IN SUBSECTION 200-1.6 EXCEPT THAT THE APPARENT
SPECIFIC GRAVITY SHALL BE NOT LESS THAN 2.62.
STONE SHALL ALSO BE TESTED FOR PERCENTAGE WEAR IN ACCORDANCE WITH ASTM C131 EXCEPT THAT
THE MAXIMUM LOSS SHALL NOT EXCEED 45% AFTER 500 REVOLUTIONS.
UNLESS OTHERWISE SPECIFIED, THE GRADATION FOR GENERAL PURPOSE USE SHALL LIE BETWEEN THE
FOLLOWING GRADATION CURVES=
% LIGHTER BY WEIGHT LIMITS OF STONE WEIGHT IN POUNDS
100 3704 1482
5Q 1098 741
15 549 232
THICKNESS (T) – PLACED DRY IN NON–TURBULENT FLOW LOCATIONS =42"
PLACED UNDER WATER = 48"
PLACED DRY IN TURBULENT FLOW LOCATIONS = 48"
PLACEMENT TOLERANCES FOR FINISHED SURFACE SHALL BE PLUS OR MINUS SIX INCHES FROM INDICATED
LINES AND GRADES.
IF GRADATION CURVE IS REQUESTED BY THE ENGINEER ALL POINTS ON INDIVIDUAL GRADING CURVES
OBTAINED FROM REPRESENTATIVE SAMPLES OF RIP–RA� STONE SHALL LIE BETWEEN LIMITS AS DEFINED BY
A SMOOTH CURVE DRAWN THROUGH TABULATED GRADING LIMITS PLOTTED ON A MECHANICAL ANALYSIS
DIAGRAM. THE GRADING CURVES WITHIN THESE LIMITS SHALL NOT SHOW ABRUPT CHANGES IN SLOPE
DENOTING SKIP GRADING, SCALPING OF CERTAIN SIZES OR OTHER IRREGULARITIES WHICH WOULD BE
DETRIMENTAL TO PROPER FUNCTIONING OF RIP–RAP STONE. GRADATION TESTING SHALL BE PERFORMED BY
AN APPROVED TESTING LABORATORY ON SAMPLES SELECTED BY THE ENGINEER, AT THE CONTACTOR'S
EXPENSE. -
STONE SHALL BE PLACED DIRECTLY ON PREPARED EARTH SUBGRADE OR AREA UNLESS ROCK FILTER
BLANKET OR FILTER FABRIC IS SPECIFIED OR SHOWN ON THE PLANS.
EACH LOAD OF STONE SHALL BE REASONABLY WELL GRADED FROM THE SMALLEST TO THE MAXIMUM SIZE
SPECIFIED. STONES SMALLER THAN THE SPECIFIED 15 .PERCENT SIZE AND SPALLS WILL NOT BE PERMITTED
IN AN AMOUNT EXCEEDING 15 PERCENT BY WEIGHT OF EACH LOAD.
STONE FOR RIP–RAP SHALL BE PLACED IN A MANNER WHICH WILL PRODUCE A REASONABLE WELL–GRADED
MASS OF STONE WITH THE MINIMUM PRACTICABLE PERCENTAGE OF VOIDS. THE ENTIRE MASS OF STONE
SHALL BE PLACED IN CONFORMANCE WITH THE LINES, GRADES AND THICKNESSES SHOWN ON THE PLANS.
RIP–RAP SHALL BE PLACED TO ITS FULL COURSE THICKNESS IN ONE OPERATION AND IN A MANNER TO
AVOID DISPLACING THE UNDERLYING MATERIAL. PLACING OF RIP–RAP IN LAYERS BY DUMPING INTO CHUTES
OR BY SIMILAR METHODS LIKELY TO CAUSE SEGREGATION, WILL NOT BE PERMITTED. SELF–PROPELLED
EQUIPMENT SHALL NOT BE USED ON EMBANKMENT SLOPES,
THE LARGER STONES SHALL BE WELL DISTRIBUTED, AND THE ENTIRE MASS OF STONE SHALL CONFORM
TO THE GRADATION SPECIFIED. ALL MATERIAL GOING INTO RIP–RAP PROTECTION SHALL BE SO PLACED
AND DISTRIBUTED THAT THERE WILL BE NO LARGE ACCUMULATIONS OF EITHER THE LARGER OR SMALLER
SIZES OF STONE.
IT IS THE INTENT OF THESE SPECIFICATIONS TO PRODUCE A FAIRLY COMPACT RIP–RAP PROTECTION IN
WHICH ALL SIZES OF MATERIAL ARE PLACED IN THEIR PROPER PROPORTIONS. HAND PLACING OR
REARRANGING OF INDIVIDUAL STONES BY MECHANICAL EQUIPMENT MAY BE REQUIRED AS NECESSARY TO
SECURE THE SPECIFIED RESULTS.
IF GROUT IS"I SPECIFIED FOR FILLING THE INTERSTICES, IT SHALL BE EITHER A 560-C-3250 OR 660–E-3250
CONCRETE MIX.
PRD/�SEZ7
1.5.
. 3 mRm
DRA/N EA 5E MENT
��� u.89• ia'49~e�
PUBLIC
STORM o
DRAIN
Ai. 09•10149"E• P.L.
jArdf'
C P/PE C [iRVf DA rA
0-A = 4C'14' 2 2"
R = 9o'
L='72.63'
T= 3S . 4 2'
� g SL OVER
.96D . Qs 6e A
C.,gAA1A1EL STA. W
V
GROUTED eoce R/P- �t'A P m
V
GRpOUTED STONE
SPLASH PAD
PER -5-P. 183 -8
. 46 �
DETAIL/0000400��
•
�
S.B.C.F.C.D. -
7 'BILE N0. S.P. 183 A
' •
- - - - - : - �
PLAN VIEW
„ „
LINE B
SCALE , r = 20'
2/.7 '` 77AP CHANNEL
�,
AS BUILT*
8-13-90 DR 88-92
& VAR 88-8
JOHNSON—FRANK ' do ASSOCIATES INC.
5150 E. HUNTER AVENUE,
ANAHEIM, CALIF. 92807
(714) 777-8877
`
CITY OF FO NTANA
ENG'R. HATE APPROVAL DATE
W L. H- 8-21-90
PUBLIC WORKS DEPARTMENT
DESIGN BY
C.t{. _._..
STORM DRAIN PLANS
DETAIL SHEET
PARCEL MAP 11668
INLAND DISTRIBUTION CENTER
SCALE
AS GHOWN
DRAWN BY
D• _..,.. _.._ _ __.
DATE
4-G- 89
PREPARED UNDER THE SUPERVISION OF
•
WILLIAM L. HARRIS R.C.E. 317,37A
CHECKED BY
APPROV_M BY
INTERIM CITY ENGINEER R.C.E. 25126
DWG. NO. SHT. NO