HomeMy WebLinkAbout1863-112034
AVENUE
GENERAL NOTES
TELEPHONE
I. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE
(714) 820-5598
REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA.
(714) 875-5100
2 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO
(213) 637-1233 -
START OF ANY WORK WITHIN THE CITY LIMITS.
(800) 422-4133
3. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE OTHERWISE NOTED.
"A" (STA 0+00 TO 6+88.59 PROFILE LNE "A",'"A-I" 8 "A-5" 8 DETAILz
4. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL
PLAN 8 PROFILE
ADJOINING CURBS AND SIDEWALKS.
"A" (STA. 6+88.59 TO 15+27.19 PROFILE LINE "A", "A-3", %-6" 8 "A-7"
5. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAS BEEN PLACED,
PLAN 8 PROFILE
ASPECTED AND APPROVED,
"A-8"9 PLAN LINE "A-9"
6. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS.
PLAN 8 PROFILE LINE
PROFILE LINE "A-4" $ "A-9",
DETAILS
7. EXISTING UNDERGROUND UTILITIES ARE AS PER THE AVAILABLE RECORDS. THE CONTRACTOR SHALL
6
BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD.
8
S. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EOUIVALENT
122 L.F.
DEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION
DETAILS
INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED.
9 CONST, BRICK 8 MORTAR PLUG
9. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS
DESCRIBED IN NOTE 8 ABOVE FROM CAL/OSHA.
I EA.
10. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT TO FINISH GRADE
BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE.
H. IMMEDIATELY FOLLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB AND/OR GUTTER THE
10 EA.
CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION OF WORK TO COMPLETION.
12. ALL C.M.P. INSTALLATIONS AND CONNECTIONS SHALL BE MADE PER MANUFACTURER'S SUGGESTED
METHOD UNLESS OTHERWISE SPECIFIED ON THE PLANS.
STEEL TROWEL FINISH AND SHALL SLOPE FROM ALL DIRECTIONS TOWARDS
13. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM APPROVED BY THE CITY
ENG"INEER SHALL BE INSTALLED TO DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER.
14. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S INSPECTOR.
2 EA.
15. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH THE CITY
STANDARD SPECIFICATIONS.
1 EA.
16. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
14 CONST. MANHOLE NO. I PER SHT. NO. 8
17. THE CONTRACTOR SHALL OBTAIN A PERMIT FROM THE SAN BERNARDINO COUNTY FLOOD CONTROL
15 CONST. MANHOLE NO. 2 PER SHT. NO. 8
DISTRICT FOR WORK WITHIN THER EASEMENT.
18. LOCATIONS OF PUBLIC UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION.
16 CONST. CATCH BASIN (W= T) MODIFIED W/8" THK. WALLS PER CITY OF
FONTANA STD. DETAIL 121 8 PER DETAIL 4
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE TRUE
17 CONST. JUNCTION STRUCTURE NO. 2 ( A= 46'53'2401 B=18" R.C.P., C=3.00',
D: 42" R.C.P.) PER SHT. NO. 9
LOCATION AND ELEVATION IN THE FIELD OF ANY EXISTING UTILITIES AND TO EXERCISE PROPER
PRECAUTIONS TO AVOID INJURY OR DAMAGE THERETO. CONTRACTOR SHALL CONTACT UNDERGROUND
18 CONST. TRAFFIC TYPE JUNCTION STRUCTURE PER CITY OF FONTANA STD.
SERVICE ALERT FOR UTILITY LOCATION BEFORE EXCAVATION AT 1-800-422-4133.
19. THE CONTRACTOR(S) SHALL COORINATE CONSTRUCTION WITH ALL UTLITIES AND OTHER IMPROVEMENTS
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE,
(TRAFFIC) ALHAMBRA FOUNDRY NO. A-11 ?0 OR APPROVED EDUAL
LANDSCAPING, LANDSCAPING IRRIATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE,
19 DELETE
FLOOD CONTROL SYSTEMS, ETC.
20. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS, AND WHERE
THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATEY REPORT SAID CONFLICT OR POSSIBLE
-
CONFLICT TO THE OWNER'S REPRESENTATIVE.
2 EA.
21. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS
1 EA.
_
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIAL, LIGHTING, TELEVISION CABLE, LANDSCAPING,
22 CONST. CATCH BASIN N0. Y (W=6.40') PER SHT. NO. 9
LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD
CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY =
CITY OF FONTANA PACIFIC TELEPHONE b TELEGRAPH COMPANY
8353 SIERRA AVENUE 3073 ADAMS STREET
1 EA.
FONTANA, CALIFORNIA 92335 RIVERSIDE, CALIFORNIA 92504
124 CONST. JUNCTION STRUCTURE NO. 4 CASE I PER SHT, NO. 9
TELEPHONE (714) 350-7610 TELEPHONE (714) 359-2524
OTE
SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT
1981 W. LUGONIA AVENUE TELEPHONE (800) 422-4133
PRIOR TO START OF ANY CONSTRUCTION WITHIN SAN BERNARDINO
REDLANDS, CALIFORNIA 92374
TELEPHONE (714) 884-9411
GROUP W CABLE
EDISON CO. EASEMENT, ALL PERMITS BY THESE AGENCIES NECESSArjY
SOUTHERN CALIFORNIA EDISON COMPANY 8561 NUEVO AVENUE
300 N. PEPPER
AVENUE
RIALTO, CALIFORNIA 92376
TELEPHONE
DESCRIPTION
(714) 820-5598
- UNDERGROUND
(714) 875-5100
- TRANSMISSION
(213) 637-1233 -
PIPELINES OR
(800) 422-4133
LINE
FONTANA, CALIFORNIA 92335
TELEPHONE (714) 350-2344
FONTANA (NATER COMPANY
FONTANA, CALIFORNIA 92335
(714) 822-2201
SOTOR.M DRAIN
IMPROVEMENT PLANS
PARCEL MAP 11668
INLAND DISTRIBUTION CENTER
CITY OF FONTANA
COUNTY OF SAN BERNARDINO
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE
THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REOUIRED
TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES
OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY
DAMAGE TO THESE LINES OR STRUCTURES.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE
CONDITIONS OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL WORKING HOURS, AND THAT
THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE ENGINEER AND THE OWNER HARMLESS FROM
ANY AND ALL LIABILITY, REAL OR ALLEDGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON
THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES
TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK,
THE CONSTRUCTION ENGINEER, CITY OF FONTANA, AND THE SAN BERNARDINO COUNTY FLOOD CONTROL
DISTRICT SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR'S AND SUBCONTRACTOR'S NON
: