Loading...
HomeMy WebLinkAbout1863-112034 AVENUE GENERAL NOTES TELEPHONE I. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE (714) 820-5598 REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. (714) 875-5100 2 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO (213) 637-1233 - START OF ANY WORK WITHIN THE CITY LIMITS. (800) 422-4133 3. STATIONING REFERS TO THE CENTERLINES OF STORM DRAINS EXCEPT WHERE OTHERWISE NOTED. "A" (STA 0+00 TO 6+88.59 PROFILE LNE "A",'"A-I" 8 "A-5" 8 DETAILz 4. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL PLAN 8 PROFILE ADJOINING CURBS AND SIDEWALKS. "A" (STA. 6+88.59 TO 15+27.19 PROFILE LINE "A", "A-3", %-6" 8 "A-7" 5. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAS BEEN PLACED, PLAN 8 PROFILE ASPECTED AND APPROVED, "A-8"9 PLAN LINE "A-9" 6. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. PLAN 8 PROFILE LINE PROFILE LINE "A-4" $ "A-9", DETAILS 7. EXISTING UNDERGROUND UTILITIES ARE AS PER THE AVAILABLE RECORDS. THE CONTRACTOR SHALL 6 BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 8 S. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EOUIVALENT 122 L.F. DEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION DETAILS INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 9 CONST, BRICK 8 MORTAR PLUG 9. THE CONTRACTOR(S) SHALL ALSO OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 8 ABOVE FROM CAL/OSHA. I EA. 10. ALL MANHOLES SHALL BE CONSTRUCTED 6" BELOW PAVEMENT GRADE AND BROUGHT TO FINISH GRADE BY THE PAVING CONTRACTOR AFTER PAVEMENT IS IN PLACE. H. IMMEDIATELY FOLLOWING REMOVAL OF EXISTING PAVEMENT OR DIKE OR CURB AND/OR GUTTER THE 10 EA. CONTRACTOR SHALL DILIGENTLY PURSUE THAT PORTION OF WORK TO COMPLETION. 12. ALL C.M.P. INSTALLATIONS AND CONNECTIONS SHALL BE MADE PER MANUFACTURER'S SUGGESTED METHOD UNLESS OTHERWISE SPECIFIED ON THE PLANS. STEEL TROWEL FINISH AND SHALL SLOPE FROM ALL DIRECTIONS TOWARDS 13. IF DURING CONSTRUCTION, GROUND WATER IS ENCOUNTERED, A SYSTEM APPROVED BY THE CITY ENG"INEER SHALL BE INSTALLED TO DEWATER SAID AREA AT THE DIRECTION OF THE SOILS ENGINEER. 14. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S INSPECTOR. 2 EA. 15. ALL EXPOSED METAL SURFACES SHALL BE GALVANIZED IN ACCORDANCE WITH THE CITY STANDARD SPECIFICATIONS. 1 EA. 16. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR. 14 CONST. MANHOLE NO. I PER SHT. NO. 8 17. THE CONTRACTOR SHALL OBTAIN A PERMIT FROM THE SAN BERNARDINO COUNTY FLOOD CONTROL 15 CONST. MANHOLE NO. 2 PER SHT. NO. 8 DISTRICT FOR WORK WITHIN THER EASEMENT. 18. LOCATIONS OF PUBLIC UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. 16 CONST. CATCH BASIN (W= T) MODIFIED W/8" THK. WALLS PER CITY OF FONTANA STD. DETAIL 121 8 PER DETAIL 4 HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE TRUE 17 CONST. JUNCTION STRUCTURE NO. 2 ( A= 46'53'2401 B=18" R.C.P., C=3.00', D: 42" R.C.P.) PER SHT. NO. 9 LOCATION AND ELEVATION IN THE FIELD OF ANY EXISTING UTILITIES AND TO EXERCISE PROPER PRECAUTIONS TO AVOID INJURY OR DAMAGE THERETO. CONTRACTOR SHALL CONTACT UNDERGROUND 18 CONST. TRAFFIC TYPE JUNCTION STRUCTURE PER CITY OF FONTANA STD. SERVICE ALERT FOR UTILITY LOCATION BEFORE EXCAVATION AT 1-800-422-4133. 19. THE CONTRACTOR(S) SHALL COORINATE CONSTRUCTION WITH ALL UTLITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, (TRAFFIC) ALHAMBRA FOUNDRY NO. A-11 ?0 OR APPROVED EDUAL LANDSCAPING, LANDSCAPING IRRIATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, 19 DELETE FLOOD CONTROL SYSTEMS, ETC. 20. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATEY REPORT SAID CONFLICT OR POSSIBLE - CONFLICT TO THE OWNER'S REPRESENTATIVE. 2 EA. 21. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS 1 EA. _ INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, 22 CONST. CATCH BASIN N0. Y (W=6.40') PER SHT. NO. 9 LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY = CITY OF FONTANA PACIFIC TELEPHONE b TELEGRAPH COMPANY 8353 SIERRA AVENUE 3073 ADAMS STREET 1 EA. FONTANA, CALIFORNIA 92335 RIVERSIDE, CALIFORNIA 92504 124 CONST. JUNCTION STRUCTURE NO. 4 CASE I PER SHT, NO. 9 TELEPHONE (714) 350-7610 TELEPHONE (714) 359-2524 OTE SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT 1981 W. LUGONIA AVENUE TELEPHONE (800) 422-4133 PRIOR TO START OF ANY CONSTRUCTION WITHIN SAN BERNARDINO REDLANDS, CALIFORNIA 92374 TELEPHONE (714) 884-9411 GROUP W CABLE EDISON CO. EASEMENT, ALL PERMITS BY THESE AGENCIES NECESSArjY SOUTHERN CALIFORNIA EDISON COMPANY 8561 NUEVO AVENUE 300 N. PEPPER AVENUE RIALTO, CALIFORNIA 92376 TELEPHONE DESCRIPTION (714) 820-5598 - UNDERGROUND (714) 875-5100 - TRANSMISSION (213) 637-1233 - PIPELINES OR (800) 422-4133 LINE FONTANA, CALIFORNIA 92335 TELEPHONE (714) 350-2344 FONTANA (NATER COMPANY FONTANA, CALIFORNIA 92335 (714) 822-2201 SOTOR.M DRAIN IMPROVEMENT PLANS PARCEL MAP 11668 INLAND DISTRIBUTION CENTER CITY OF FONTANA COUNTY OF SAN BERNARDINO PRIVATE ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THIS PLAN. THE CONTRACTOR IS REOUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE ENGINEER AND THE OWNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEDGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK, THE CONSTRUCTION ENGINEER, CITY OF FONTANA, AND THE SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTOR'S AND SUBCONTRACTOR'S NON :