Loading...
HomeMy WebLinkAbout1818-7C O N D U C T O R S C H E D U L E AW CIRCUIT 1 2-N-16 PHASE 6 RUN NO, 2 34--06 PHASE 6 - - 3 4-N-06 PHASE 1 1 C1 - 01 FUIURE - - - - 3A.111.�Llp4lj - - 2 34--08 PHASE 8 - - 12 - 3 3 3-- 1 I 2-S-02 3 3 - 13 3 3 3 3 3 3 6 6 PHASE 4 04 - - - - 3 3 3 3 1 05 FUTURE - 3 3 3-- CALL HOLD 3 1-S-12 EXP 2 Al 3 3 CALL HOLD 06 - B 8 - 3 3 3 3 2.5 07 _ _ _ 3 200 W 8 3 3 MA SV -1-T 08 3 3 3 3_- 1-A too 3 3 /2P 1 W 2 2 - 2 4 4 #14 06P - 2 2 2 2 2 1 4 4 Cibus Ave 08P 2 2 2 2-- - - 2 2 - 02 PP8 - - - 1 - - 1 1 06 PP8 1 1 1 1 1 1 2 2 18 PP8 - 1 1 1 -- 1 1 PP8 COMMON 1 1 1 1 1 1 2 2 SPARES 3 3 I 3 3 1 3 3 6 6 TOTAL 13 22 24 28 19 21 46 46 12 ISMS: 2 2 2 2 2 2-- LUMINAK 2 2 2 2 2 2-- #10 SIGNAL COMMON 1 1 1 1 1 1 2 2 TOTAL 3 3 3 3 3 3 2 1 2 SIGNAL SOWE - - - 3 - - 3 1 3 12 - - - - - 3 3 3 2 13 - - - 2 - - 2 2 #16 14 3 3 3 3-- 3 I 3 TYPE 16 - 3 3 3-- 3 3 B 11 2 2 2 2-- 2 2 DLC 18 - - - 3 - - 3 3 16FLIT, 01 - 2 2 2-- 2 1 2 14FLIT. 15 - - - - - 2 2 2 TOTAL 5 1 10 10 1 15 0 0 20 20 CONDUIT SIZE 2 3 3 3 2 2 2 -FF DaP T'14 -30 if 11 30 30 30 3v 30 30 (1) FUTURE 07 TURN PHASE PROMM TO THROUGH PHASE P H A S E D I A G R A M 1 • 1 DETECTOR SCHEDULE GROUP B Z SE1N MW DETECTOR ORM NUT SY U Wff W 1 1 2-N-16 PHASE 6 - - 2 34--06 PHASE 6 - - 3 4-N-06 PHASE 1 1 C1 - 4 5-N-06 PHASE 1 1 - - 2 1 1 24-08 PHASE 8 - - 2 34--08 PHASE 8 - - 3 1-E-03 PHASE 3 C2 - 4 24-0 PHASE 3 - - 3 1 I 2-S-02 PHASE 2 - - 2 ,-S--02 PHASE 2 - - 3 4-S-/2 PHASE 5 1 D1 200 W 4 5-S-/2 PHASE 5 1 6 4 1 24-04 PHASE 4 - - 2 34--/4 PHASE 4 - - 3 14-07 PHASE 7 D2 - 4 24-17 PHASE 7 - - 5 1 1 N 16 E F 6 A2 CALL HOLD 2 1-E-108 EXP 8 81 CALL HOLD 3 1-S-12 EXP 2 Al CALL HOLD 4 14-14 1 EXP 4 1 82 1 CALL HOLD (1) FUTURE 07 TURN PHASE PROMM TO THROUGH PHASE P H A S E D I A G R A M 1 • 1 GROUP A GROUP B Z (FUTURE) 0 L it ►' I H E D U L E No. 23oos �" _ PHASE 1 PHASE 2 PHASE 3 PHASE 4 Z (FUTURE) / LUMINAIRE 1 PUSH I SIGNAL MOUNTING I.S.N.S. ** PHASE 5 PHASE 6 PHASE 7 PHASE 8 r INSTALL AND CAP 3" C. WITH PULLROPE FOR FUTURE IMPROVEMENTS R/W CITRUS N---- ---- ---- ---- ---- ---- ---- ---- ---- —�-- -- ------ -- ---- 1� �I 1 I 230 TO LIMIT LINE ---- ----------- ---------k---- ``!"�----------- ---- NE04 115 TO LIMIT LINE CN - - 0 -6"G ---------------------------- C14 --------------------------N 1 EX. CURB & GUTTER / OVERHEAD — _ _ % T T \� �� -— —— —r-- #6 co M - - - - - L E_'6 a L_ J 1.5" C. 1–DLC 02 PPB 1.5" C. 2–DLC FUN fir 6'- 15 5/0 P/iorAWD C,pc,{T/bt1 /.}S /Jo76'b 25' onS2' 20'f 40' , V) 1-W-04 30 w (° 3) I o I V) w w w w II ♦ ` II > II II I 11 II II II II 0711 I II II II II II I II II II II r II � , J-W-�f II II I1 I II II I 1 niLl 1.5" C. 1–DLC # = CALTRMS TYPE 'A' PER FONTANA STANDARD DETAwL 132. ++ = FUTURE 40' SIMAL ARV. 0*0000M - SCALE: 1" = 20' PROPOSED 35' R. CURB RETURN nar :w P50 A� f 1141 _ I B.C.R. + - I I B� STANDARD PLACEMENT DETAIL L do n '4u 0 aur '�10" 120E IT'S THE LAWI DIAL BEFORE YOU DIG! 1-800-422-4133 CALL AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATING UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 FH 0630 1.5" C. 2–DLC PROPOSED R/W PP #1979-)14 _ _— _ 06 PPB ---------------- VERHEAD ( R1W 1.5" C. 1–DLC g g T 06P 08P _r- - _ - _ 8 3 0800 ;—T. --�-,� 1 PROPOSED C B & GUTTER _ — — T — — — — — — — _ ► �. PP EX. AC PARKING LOT EX. CURB & GUTTER 1 'Now, 06 2 G 2„G _ - _ _ j 115' TO LIMIT LINE N ? 230 TO LIMIT LINE / WV WV/ -0-0N\__ i 1 1<<1 ---- ---- ---- 61PW --- ---- ---- 6"W WV , 02P ; AVENUE /m 06 T-------------------------------------------------------------------------------------------------- (FUT.- 01) -- – – –– – – – – –– ------ ---- --''' S OVERHEAD p -08 PPB • I .. OINT -- -- -- o -- -- R/W -- -- PP:: 2 PPB –' ------ --,-171 --T---- T-- --- - Q 1 II I I � '• �'�' J� - .. 1-7 r3 II ® ' T II I I II I II I I #6E I I II I 1 II I I 8 I I II I I I I I � ♦ I I � �, I I I II 1) 1 II I I I u v 1 1 I I II I ( I II I I I II I II II I 1 I-08 C< 1Ij I II I I � I I $0 II I I I 0 II I I III—E-031 81 II I W I W II II I J I PP Y`� I II I I — -� 8 u 1 1 ❑ I II 1L O 1 ~ 6I O 11 I I II I I 11 1 1 � I II I I Lj I 1111 I 1 2- -48 W 111 1 11 1 1 11 1 1 II I I I II I I 3r> II 1 I I EXI pWY. I II II II II I 1- -0 36' 36' 50 50' 2" C. 3 #8, 4 #10 & 4 #12 CONSTRUCTION NOTES: 1.5" C. 2–DLC a —�— 1.5" C. 1–DLC R E V I S 1 0 N S R E F E R E N C E S BSI Consultants, Inc. PREPARED UNDER THE SUPERVISION OF: 1906 S. Commercenter E. I Suite 204 Sart Bernardi; CA 92408 (714) � 884-2500 R�:C:64 23006 EXP. 12/31/q3 DAIS DESIGN: DRAFT: D.R.B. aRiB. CHECK: DATE: 76-R2/ RECORD DRAWING I D.R. 6_q0 Ej] INSTALL AN EIGHT PHASE TYPE 90 CONTROLLER WITH INTERNAL TIME BASE COORDI NA TION SYSTEM TELEMETRY EQUIPMENT AND APPURTENANCES IN A TYPE P ALUMINUM CABINET PER CITY OF FONTANA STANDARDS. CABINET FOUNDATION TO EXTEND 18" ABOVE GRADE. INSTALL NEMA CAN FOR TELEPHONE INTERCONNECT. ❑2 INSTALL 120/240 VOLT TYPE ,Bj--BF SERVICE W1TH 120 VOLT 50 AMP METERED SIGNAL CIRCUIT, 120 VOLT 15 AMP METERED I. S. N. S. CIRCUIT AND 120 VOLT 30 AMP UNMETERED LIGHTING CIRCUIT. INSTALL TWO (2) TYPE -7 P.E. CONTROL UNITS. INSTALL TEST SWITCH ON 1. S. N. S. CIRCUIT ONLY. ❑3 INSTALL 3" CONDUIT WITH PULLROPE AND 36" PVC SCH. 80 RISER SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE PEDI SIAL PER EDISON REQUIREMENTS. ® INSTALL 1.5" CONDUIT WITH PULL ROPE FOR TELEPHONE LINE INTERCONNECT SERVICE FROM SERVICE POINT TO NEMA CAN ON CONTROLLER CABINET. ❑5 RETROFIT HANDICAPPED RAMP PER CITY OF FONTANA STANDARD DETAIL 104A AND CONSTRUCT ADJACENT SIDEWALK. © EDISON TO REMOVE EXISTING STREET LIGHT AND LUMINAIRE ARM FROM POWER POLE. Ffl EDISON TO REMOVE EXISTING POLE WITH LUMINAIRE. r -fl INSTALL PULLBOX PER CITY OF FONTANA TRAFFIC SIGNAL DESIGN GUIDLINES AND STATE STANDARD PLAN ES -8. NOTE: THESE PLANS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF THE AGENCY AND SHALL NOT BE USED IN ANY MANNER WITHOUT PRIOR CONSENT OF THE AGENCY. ANY REUSE OF THE THESE PLANS AND SPECIFICATIONS BY AGENCY OR OTHERS SHALL BE AT THE AGENCY'S AND/OR OTHER'S SOLE RISK AND WITHOUT LIABILITY TO BSI CONSULTANTS, INC. QROFESS/p�y,. 1 • 1 o ;` 1.5" C. 2–DLC 0 L it ►' I H E D U L E No. 23oos �" _ CITRUS 11VENUE 1"=20' DESIGN BY: STANDARD 1 1, m v � LUMINAIRE 1 PUSH BT, SIGNAL MOUNTING I.S.N.S. ** # = CALTRMS TYPE 'A' PER FONTANA STANDARD DETAwL 132. ++ = FUTURE 40' SIMAL ARV. 0*0000M - SCALE: 1" = 20' PROPOSED 35' R. CURB RETURN nar :w P50 A� f 1141 _ I B.C.R. + - I I B� STANDARD PLACEMENT DETAIL L do n '4u 0 aur '�10" 120E IT'S THE LAWI DIAL BEFORE YOU DIG! 1-800-422-4133 CALL AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATING UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 FH 0630 1.5" C. 2–DLC PROPOSED R/W PP #1979-)14 _ _— _ 06 PPB ---------------- VERHEAD ( R1W 1.5" C. 1–DLC g g T 06P 08P _r- - _ - _ 8 3 0800 ;—T. --�-,� 1 PROPOSED C B & GUTTER _ — — T — — — — — — — _ ► �. PP EX. AC PARKING LOT EX. CURB & GUTTER 1 'Now, 06 2 G 2„G _ - _ _ j 115' TO LIMIT LINE N ? 230 TO LIMIT LINE / WV WV/ -0-0N\__ i 1 1<<1 ---- ---- ---- 61PW --- ---- ---- 6"W WV , 02P ; AVENUE /m 06 T-------------------------------------------------------------------------------------------------- (FUT.- 01) -- – – –– – – – – –– ------ ---- --''' S OVERHEAD p -08 PPB • I .. OINT -- -- -- o -- -- R/W -- -- PP:: 2 PPB –' ------ --,-171 --T---- T-- --- - Q 1 II I I � '• �'�' J� - .. 1-7 r3 II ® ' T II I I II I II I I #6E I I II I 1 II I I 8 I I II I I I I I � ♦ I I � �, I I I II 1) 1 II I I I u v 1 1 I I II I ( I II I I I II I II II I 1 I-08 C< 1Ij I II I I � I I $0 II I I I 0 II I I III—E-031 81 II I W I W II II I J I PP Y`� I II I I — -� 8 u 1 1 ❑ I II 1L O 1 ~ 6I O 11 I I II I I 11 1 1 � I II I I Lj I 1111 I 1 2- -48 W 111 1 11 1 1 11 1 1 II I I I II I I 3r> II 1 I I EXI pWY. I II II II II I 1- -0 36' 36' 50 50' 2" C. 3 #8, 4 #10 & 4 #12 CONSTRUCTION NOTES: 1.5" C. 2–DLC a —�— 1.5" C. 1–DLC R E V I S 1 0 N S R E F E R E N C E S BSI Consultants, Inc. PREPARED UNDER THE SUPERVISION OF: 1906 S. Commercenter E. I Suite 204 Sart Bernardi; CA 92408 (714) � 884-2500 R�:C:64 23006 EXP. 12/31/q3 DAIS DESIGN: DRAFT: D.R.B. aRiB. CHECK: DATE: 76-R2/ RECORD DRAWING I D.R. 6_q0 Ej] INSTALL AN EIGHT PHASE TYPE 90 CONTROLLER WITH INTERNAL TIME BASE COORDI NA TION SYSTEM TELEMETRY EQUIPMENT AND APPURTENANCES IN A TYPE P ALUMINUM CABINET PER CITY OF FONTANA STANDARDS. CABINET FOUNDATION TO EXTEND 18" ABOVE GRADE. INSTALL NEMA CAN FOR TELEPHONE INTERCONNECT. ❑2 INSTALL 120/240 VOLT TYPE ,Bj--BF SERVICE W1TH 120 VOLT 50 AMP METERED SIGNAL CIRCUIT, 120 VOLT 15 AMP METERED I. S. N. S. CIRCUIT AND 120 VOLT 30 AMP UNMETERED LIGHTING CIRCUIT. INSTALL TWO (2) TYPE -7 P.E. CONTROL UNITS. INSTALL TEST SWITCH ON 1. S. N. S. CIRCUIT ONLY. ❑3 INSTALL 3" CONDUIT WITH PULLROPE AND 36" PVC SCH. 80 RISER SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE PEDI SIAL PER EDISON REQUIREMENTS. ® INSTALL 1.5" CONDUIT WITH PULL ROPE FOR TELEPHONE LINE INTERCONNECT SERVICE FROM SERVICE POINT TO NEMA CAN ON CONTROLLER CABINET. ❑5 RETROFIT HANDICAPPED RAMP PER CITY OF FONTANA STANDARD DETAIL 104A AND CONSTRUCT ADJACENT SIDEWALK. © EDISON TO REMOVE EXISTING STREET LIGHT AND LUMINAIRE ARM FROM POWER POLE. Ffl EDISON TO REMOVE EXISTING POLE WITH LUMINAIRE. r -fl INSTALL PULLBOX PER CITY OF FONTANA TRAFFIC SIGNAL DESIGN GUIDLINES AND STATE STANDARD PLAN ES -8. NOTE: THESE PLANS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF THE AGENCY AND SHALL NOT BE USED IN ANY MANNER WITHOUT PRIOR CONSENT OF THE AGENCY. ANY REUSE OF THE THESE PLANS AND SPECIFICATIONS BY AGENCY OR OTHERS SHALL BE AT THE AGENCY'S AND/OR OTHER'S SOLE RISK AND WITHOUT LIABILITY TO BSI CONSULTANTS, INC. QROFESS/p�y,. CITY OF FONTANA, CALIFORNIA o P 0 L E S C H E D U L E No. 23oos �" �8 CITRUS 11VENUE 1"=20' DESIGN BY: STANDARD � Exp. � i � ARMS LUMINAIRE PED PUSH BT, SIGNAL MOUNTING I.S.N.S. ** PLACEMENT TYPE HT. SG. LUM. H.P.&V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B 1 26-4-80 30 125++ 15 1 200 W B 6 W MA SV -3-M 17 -1 -CS Arnow Blvd 0 25 2 26-4-80 30 45 15 200 W B 6 1 E NAS Mg SV -1-T 90--1-CS Crus Awe 181 2.5 3 1-A 10 - - - B 8 S TV -1-T 90 -1 -CS - 1 2.5 JU 30 25++ 15 200 W 8 8 S MA SV -1-T SP 1 -CS Arnow Blvd 8 51 1-A too 8 1 W TV -1-T SP -1 -CS - 0 6 6 26-4-80 30 40p 200 W B 1 1 W MAM SV -1-T - Cibus Ave 8 5 7 1-A 10 - - - - - - N -1-T 51' -1 -CS - 11 25 # = CALTRMS TYPE 'A' PER FONTANA STANDARD DETAwL 132. ++ = FUTURE 40' SIMAL ARV. 0*0000M - SCALE: 1" = 20' PROPOSED 35' R. CURB RETURN nar :w P50 A� f 1141 _ I B.C.R. + - I I B� STANDARD PLACEMENT DETAIL L do n '4u 0 aur '�10" 120E IT'S THE LAWI DIAL BEFORE YOU DIG! 1-800-422-4133 CALL AT LEAST TWO WORKING DAYS PRIOR TO EXCAVATING UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 FH 0630 1.5" C. 2–DLC PROPOSED R/W PP #1979-)14 _ _— _ 06 PPB ---------------- VERHEAD ( R1W 1.5" C. 1–DLC g g T 06P 08P _r- - _ - _ 8 3 0800 ;—T. --�-,� 1 PROPOSED C B & GUTTER _ — — T — — — — — — — _ ► �. PP EX. AC PARKING LOT EX. CURB & GUTTER 1 'Now, 06 2 G 2„G _ - _ _ j 115' TO LIMIT LINE N ? 230 TO LIMIT LINE / WV WV/ -0-0N\__ i 1 1<<1 ---- ---- ---- 61PW --- ---- ---- 6"W WV , 02P ; AVENUE /m 06 T-------------------------------------------------------------------------------------------------- (FUT.- 01) -- – – –– – – – – –– ------ ---- --''' S OVERHEAD p -08 PPB • I .. OINT -- -- -- o -- -- R/W -- -- PP:: 2 PPB –' ------ --,-171 --T---- T-- --- - Q 1 II I I � '• �'�' J� - .. 1-7 r3 II ® ' T II I I II I II I I #6E I I II I 1 II I I 8 I I II I I I I I � ♦ I I � �, I I I II 1) 1 II I I I u v 1 1 I I II I ( I II I I I II I II II I 1 I-08 C< 1Ij I II I I � I I $0 II I I I 0 II I I III—E-031 81 II I W I W II II I J I PP Y`� I II I I — -� 8 u 1 1 ❑ I II 1L O 1 ~ 6I O 11 I I II I I 11 1 1 � I II I I Lj I 1111 I 1 2- -48 W 111 1 11 1 1 11 1 1 II I I I II I I 3r> II 1 I I EXI pWY. I II II II II I 1- -0 36' 36' 50 50' 2" C. 3 #8, 4 #10 & 4 #12 CONSTRUCTION NOTES: 1.5" C. 2–DLC a —�— 1.5" C. 1–DLC R E V I S 1 0 N S R E F E R E N C E S BSI Consultants, Inc. PREPARED UNDER THE SUPERVISION OF: 1906 S. Commercenter E. I Suite 204 Sart Bernardi; CA 92408 (714) � 884-2500 R�:C:64 23006 EXP. 12/31/q3 DAIS DESIGN: DRAFT: D.R.B. aRiB. CHECK: DATE: 76-R2/ RECORD DRAWING I D.R. 6_q0 Ej] INSTALL AN EIGHT PHASE TYPE 90 CONTROLLER WITH INTERNAL TIME BASE COORDI NA TION SYSTEM TELEMETRY EQUIPMENT AND APPURTENANCES IN A TYPE P ALUMINUM CABINET PER CITY OF FONTANA STANDARDS. CABINET FOUNDATION TO EXTEND 18" ABOVE GRADE. INSTALL NEMA CAN FOR TELEPHONE INTERCONNECT. ❑2 INSTALL 120/240 VOLT TYPE ,Bj--BF SERVICE W1TH 120 VOLT 50 AMP METERED SIGNAL CIRCUIT, 120 VOLT 15 AMP METERED I. S. N. S. CIRCUIT AND 120 VOLT 30 AMP UNMETERED LIGHTING CIRCUIT. INSTALL TWO (2) TYPE -7 P.E. CONTROL UNITS. INSTALL TEST SWITCH ON 1. S. N. S. CIRCUIT ONLY. ❑3 INSTALL 3" CONDUIT WITH PULLROPE AND 36" PVC SCH. 80 RISER SWEEP FROM ELECTRICAL SERVICE POINT TO SERVICE PEDI SIAL PER EDISON REQUIREMENTS. ® INSTALL 1.5" CONDUIT WITH PULL ROPE FOR TELEPHONE LINE INTERCONNECT SERVICE FROM SERVICE POINT TO NEMA CAN ON CONTROLLER CABINET. ❑5 RETROFIT HANDICAPPED RAMP PER CITY OF FONTANA STANDARD DETAIL 104A AND CONSTRUCT ADJACENT SIDEWALK. © EDISON TO REMOVE EXISTING STREET LIGHT AND LUMINAIRE ARM FROM POWER POLE. Ffl EDISON TO REMOVE EXISTING POLE WITH LUMINAIRE. r -fl INSTALL PULLBOX PER CITY OF FONTANA TRAFFIC SIGNAL DESIGN GUIDLINES AND STATE STANDARD PLAN ES -8. NOTE: THESE PLANS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTY OF THE AGENCY AND SHALL NOT BE USED IN ANY MANNER WITHOUT PRIOR CONSENT OF THE AGENCY. ANY REUSE OF THE THESE PLANS AND SPECIFICATIONS BY AGENCY OR OTHERS SHALL BE AT THE AGENCY'S AND/OR OTHER'S SOLE RISK AND WITHOUT LIABILITY TO BSI CONSULTANTS, INC. QROFESS/p�y,. CITY OF FONTANA, CALIFORNIA o PUBLIC WORKS DEPARTMENT JERRY CD HAHSL m CAD BY: TRAFFIC SIGNAL PLAN SCALE: No. 23oos �" �8 CITRUS 11VENUE 1"=20' DESIGN BY: DATE: � Exp. � i � AND � CIV DRB ARROW BLV 10 18 91 CHECKED BY: DR. N0.: APPROVED OF DR ENG INEER R. E. 4o 1818 8