HomeMy WebLinkAbout1812-1GENERAL NOTES
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE
PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS,
PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS
AND TERMS IN CITY STANDARD SPECIFICATIONS.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS
DEPARTMENT --PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS.
3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRAC-
TOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. CONTRACTOR SHALL
NOTIFY THE ENGINEER 48'HOURS PRIOR TO THE ANTICIPATED START OF
OF CONSTRUCTION.'
4. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER
POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC.,
SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE
IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY
OTHERS; IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL
OF THE AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
5. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
5. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
WORK AROUND THEIR FACILITIES.
7. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER.
8. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY
ENGINEER.
9. BACKFILL MATERIALS TO HAVE A.S.E. OF 30 (MIN.) AND MINIMUM
COMPACTION OF 90%.
10. ALL NEW OR EXISTING VALVE CANS AND MANHOLES SHALL BE ADJUSTED TO
GRADE DURING PAVING.
11. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED BY
THE CITY ENGINEER.
12. CONTRACTOR SHALL NOT OPERATE ANY MA I N L I NE WATER VALVE ON r,-)(ISrlAl�
w#-rT5 tLlNe5 .
13. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, WORK SHALL STOP AND THE ENGINEER NOTIFIED
I MMED I ATELY.' '
14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE
ENGINEER AFTER THE BASE COURSE HAS BEEN CONSTRUCTED AND BEFORE THE
PAVING HAS BEEN INSTALLED SO THAT THE ENGINEER MAY INSTALL THE
STREET CENTERLINE MONUMENTS AS REQUIRED BY THE CITY CODE OF THE
CITY OF FONTANA.
16'. 1NATEf� VALVF AVERS 64,9LL. 5E' 9/WS571) -M OY TFC- FigVIN4-
CON77?fI GTOR ,
PAVING NOTES
ACTUAL THICKNESS OF BASE MATERIAL TO BE DETERMINED BY SOIL TEST AND
RECOMMENDED BY THE SOILS ENGINEER:%R" VALUES, SAND EQUIVALENTS AND
STRUCTURAL SECTION OF STREETS SHALL BE SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE. THE
CITY ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR
LEAVING IMPROVEMENTS.
PAyEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL
OF THE CITY A5 REQUIRED BY 601L5 TEST TAKEN AFTEf? COMI`LETION OF I?OU6H GRADING.
PRIVATE ENGINEERS NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
CONFIRMED BY THE CONTRACTOR SO THAT ANY NECESSARY ADJUSTMENT CAN
BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT.
THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD
OR NOT SHOWN ON THESE PLANS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPON-
SIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS, AND THAT THE CONTRACT SHALL DEFEND, INDEMNIFY
AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL
PROJECTS EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE OWNER OR .THE ENGINEER.
CAUTION:
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR
LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL
CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE
PREPARER OF THESE PLANS, HND q5 APPRDVED 6y THE- GITy [NhZek.
BENCH MARK FWE 1
USCGS STATION 'PACEL' 1963.90'± ELY. OF
RAILROAD TRACKS AND 28'± SLY. OF CL BASELINE.
1.1 MI. ELY. OF EAST AVENUE. SAME AS CITY B.M. #364
ELEVATION 1301.549
STREET IMPROVEMENT PLANS
m;3
HlbHLANU �Q�" `��/ AVENUE
w /
OS
.... D 115 w 38 13138
TRACT N 4131w/ z
w w
Z Q
SOUTHERN �� _ PAC/r/C w No
IN THE �- 11
//6A,5E LINE AVENUE
/y SOUTH W
\ �O
I TY OF FONTANA// j RI T GE , GSR �'9O
z��y MILLER AVENUE
�00,00� a. N.T.S.
COUNTY OF SAN BERNARD
CONSTRUCTION NOTES
DESCRIPTION:
1. CONSTRUCT it A.C. OVER it A.B. PAVING. (ASSUME 4" A.C. OVER
ATIVE ' FOR ESTIMATING PURPOSES ONLY. ACTUAL PAVING THICKNESS TO
BE DETERMINED PER PAVING NOTE ON SHEET 1.3_ &-CONSTRUCT 6" CURB 8 GUTTER PER CITY STD. 101.-
4. CONSTRUCT 4" THICK P.C.C. SIDEWALK PER CITY STD. 105A:
&-CONSTRUCT RESIDENTIAL DRIVEWAY PER CITY STD . 102 (W=. 1 5' MAX X=3'3
(TO OE FIELD LOCATED)
6" TO g° Col?E3 7WAAl51r001-/ P /f _S/YT.' S
10 CC�c/STie?vcr �r,�Ewa�K z�)eAiw PSR ow syr 5; -
INSTALL
INSTALL SINGLE 5800 H.P.S. STREET LIGHT.
,� 12 COge, aglL L Ex is r CONC. CURB Iq NO INS r�4 L L 3" CA57' / RO/V PIPE PE @ S - 0.0/00 W l rHIN
9/GH%' OF WlgY FOR LOT' ,C7/2.91NAGE, (/NVeRr OF PIPE r"O 5E / lAeoUE Ex/sT; CURZ3 ELOWL//VE)
UTILITY NOTIFICATIONS
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CALIFORNIA 92335
TELEPHONE (714)350-7510
S0. CALIF. GAS COMPANY -DISTRIBUTION FACILITIES
570 4TH STREET, P.O. BOX 6226
SAN BERNARDINO, CALIFORNIA 92408
TELEPHONE (714)884-9411 OR (800)422-4133
S0. CALIF. GAS COMPANY -TRANSMISSION DEPARTMENT
2191 BIRCH STREET
BREA, CALIFORNIA 92621
TELEPHONE (714) 529-2889 OR [800] 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
1351 E. FRANCIS AVENUE, P.O. BOX 513
ONTARIO, CALIFORNIA 92621
TELEPHONE (714)947 -2996 -UNDERGROUND POWER
[714)875 -5100 -TRANSMISSION
(213)637 -1233 -PIPELINES, OR
(800]422-4133
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN VIEW AVENUE
POMONA, CALIFORNIA 91766
TELEPHONE [2131357-2257 OR [800]422-4133
SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT
825 EAST THIRD STREET
SAN BERNARDINO. CALIFORNIA 92408
TELEPHONE (714)383-1665
PACIFIC TELEPHONE 8 TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE. CALIFORNIA 92504
TELEPHONE (714)359-2585 OR [6001422-4133
UND)eGrWiVD SECVtGE Ae_6�CT /-z�-402-4133
INO
QUANTITIES
TRACT NOS.
13138
13138-1
TOTAL
15, 600 S. F
-31, 0 30 S. F
4a', 660 5. !=
885 L. F
1, 03.5 L.F
/, DeO L. F
2185 S.F
21760 5.F
4,945 5F
I, 368 5.17
1,824 S. F
3,192 S,1:
6 L.F
165 LF.
165 LF
2 �5A -
1 EQ.
3 i5 .
r4 LF
28 L.F
¢2 L -r -
VICINITY MAP
NOT TO SCALE
SrC� OACKE30Nf�E SYSTE-=M F109
L Ors FRovr T /iVc? E'. coalen-rurioAl
WAY
R/W 50� R/ W
7' 18 18� 7'
4.5' 8' 10' 10' 8' 4.5'
LEVEL LINE
0,071 0.20' 0.20' 0.07
2% I
' 4
4) (2
TYPICAL SECTION - LEVEL
REVISION
00 conk r. NO re /e FOR Lo rs 18 e 23 OF rR t3 r38
NO FOR LOT'S / 8 9 !6 OF rR. 13138-1
ENGR' SI DATE I OI TY I DATE
APPROVAL APPROVAL
• ---_"'yam fix.
l�la Or B.P.
.::i
WIN..............l:
• : .. •x:11
PPOJECT I
AR
�`'• May tl'S
x aCC/VC
C
" , � » . » a ° ° ° " « .'.'«°.°.`«a.P.°�'o'�°, o'c^t�'�4`,`e'`'4«a«".`Y`«a«4.`w'«°.°.�.'�'«°i a ."L'e'o'.`•°.'.".`, «'."�`�'«'.°.'.� .': ; �'.'o'e �; •'�'.'
" » » . ,. ° ° " «. » ., . a a ° 0'1'� o ,r,'�'`y , , . . ° a ° 4'S•a o . i o4 �`•�i r , r. .. ... ... .. ..
��► a� l ST,p �► ��
4 N0' 25083 INDEX M
* Elp. 1?•31 •B$ l¢
�, e1YI�Q NOT TO SCALE
97 ILI.
_..
repared in the office of: C I TY OF FONTANA , CAL I F 0 R N I A
Adams Streeter PUBLIC WORKS DEPARTMENT
CIVIL ENGINEERS INC.
Drawn.,by:STREET IMPROVEMENT PLANS Sa°IQ:
Adams • Streeter 15 Corporate Parki
CIVIL ENGINEERS INC. Irvine. CA 92714 (71 4) 474-2330 TI /TLE SHEET
Designed by: Date:
ate, •z4 TRACT:NOS. 13138 13138=1
RANDAL L. STREETER R.C.E. # 25083 DATE Cheoked by:�L o / Dwg. No. 1
MY REGISTRATION EXPIRES 12-31-89 t-/,4/88- 630 Sj. 6. 5 . Approved : �� 9 6i
__WTERiMC7Y ENGINEER R.C.E. 2.5126