HomeMy WebLinkAbout1772-1GENERAL NOTES
1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE
PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS,
PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS
AND TERMS IN CITY STANDARD SPECIFICATIONS ,DATED 1975.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS
DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS.
3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRAC-
TOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. CONTRACTOR SHALL
NOTIFY THE ENGINEER 48 -HOURS PRIOR TO THE ANTICIPATED START OF
OF CONSTRUCTION.
4. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER
POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC.,
SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE
IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY
OTHERS; IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL
OF THE AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
5. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
5. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO
WORK AROUND THEIR FACILITIES.
7. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER.
8. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY
ENGINEER.
9. BACKFILL MATERIALS TO HAVE A.S.E. OF 30 (MIN.) AND MINIMUM
COMPACTION OF 90%.
10. ALL NEW OR EXISTING VALVE CANS AND MANHOLES SHALL BE ADJUSTED TO
GRADE DURING PAVING . BY THE PAVING CONTRACTOR.
11. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED BY
THE CITY ENGINEER.
12. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE ON EXISTING
WATER LINES.
13. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE,
PROPOSED IMPROVEMENTS, WORK SHALL STOP AND THE ENGINEER NOTIFIED
IMMEDIATEDLY.
14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE
ENGINEER AFTER THE BASE COURSE HAS BEEN CONSTRUCTED AND BEFORE THE
PAVING HAS BEEN INSTALLED SO THAT THE ENGINEER MAY INSTALL THE
STREET CENTERLINE MONUMENTS AS REQUIRED BY THE CITY CODE OF THE
CITY OF FONTANA.
15. PAVEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO
REVISION AND APPROVAL. OF THE CITY AS REQUIRED BY SOILS
TEST TAKEN AFTER COMPLETION OF ROUGH GRADING.
PAVING NOTE
ACTUAL THICKNESS OF BASE MATERIAL TO BE DETERMINED BY SOIL TEST AND
RECOMMENDED BY THE SOILS ENGINEER R. VALUES, SAND EQUIVALENTS AND
STRUCTURAL SECTION OF STREETS SHALL BE SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM
UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OT THE SITE. THE
CITY ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR
LEAVING IMPROVEMENTS.
PRIVATE ENGINEER'S NOTICE i0 CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN
BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT.
THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD
OR NOT SHOWN ON THESE PLANS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPON-
SIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL APPLY CONTINUOSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS, AND THAT THE CONTRACT SHALL DEFEND, INDEMNIFY
AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL
PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE OWNER OR .THE ENGINEER.
CAUTION:
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR
LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL
CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE
PREPARER OF THESE PLANS.
BENCH MARK FUE 1
USCGS "O" STATION 'PACEL' 1963.90'± ELY. OF
RAILROAD TRACKS AND 281± SLY. OF CL BASELINE.
1.1 MI. ELY. OF EAST AVENUE. SAME AS CITY B.M. #364
ELEVATION 13 01 .54'
STREET IMPROVEMENT PLANS
FOR
TRACT
NOS.
13090 & 13 090- I
I N THE
CITY OF FONTANA
COUNTY OF SAN BERNARD I NO
CONSTRUCTION NOTES QUANTITIES
DESCRIPTION: TRACT N0.13090 TRACT NO. 13090-1
UNIT QUANTITY QUANTITY
(D_
CONSTRUCT " A.C. OVER A.B. PAVING. (ASSUME 4" A.C. OVER
NATIVE FOR ESTIMATING PURPOSES ONLY. ACTUAL PAVING THICKNESS TO
BE DETERMINED PER PAVING NOTE ON SHEET 1.)
2� CONSTRUCT 6" CURB & GUTTER PER CITY STD. 101.
Q ---CONSTRUCT 6" CONC. CURB ONLY PER CITY STD. 101 [MONOLITHIC WITH
CROSS GUTTER)
CONSTRUCT 4" THICK P.C.C. SIDEWALK PER CITY STD. 105A. -
5. CONSTRUCT CROSS GUTTER PER CITY STD. 104.
6. CONSTRUCT RAMPED CURB RETURN (WHEELCHAIR RAMP) PER CITY STD. 104-A.-
D.- CONSTRUCT RESIDENTIAL DRIVEWAY PER CITY STD. 102 (W=16' MAX ; X=3')
EXACT LOCATION TO BE DETERMINED AT THE TIME OF GONSTR.UCTcON
(,EXACT
8�I CURB & GUTTER PER CITY STD. 101.
0--`_ CONCvTRUCT CURB TRANSITION FROM GIIC.F TO 51'C-F=-
INSTALL
1'C.F.INSTALL SINGLE 5800 H.P.S. STREET LIGHT.
IMPORTANT NOTICE
Section 4216/4217 of the Government Code
requires a DIG ALERT IDENTIFICATION NUMBER be
issued before a 'Permit to Excavate' will be valid
For your DIG ALERT I.D. NUMBER
call Underground Service Alert
TOLL FREE
1-800-422-4133
Two working days before you dig
UTILITY NOTIFICATIONS
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CALIFORNIA 92335
TELEPHONE (7143350-7540
GAS:
SO. CALIF. GAS COMPANY -DISTRIBUTION FACILITIES
16-231 VA LLY BLVD.
FONTANA, CALIFORNIA 92335
MR. LOU WESTFALL
SO. CALIF. GAS COMPANY -TRANSMISSION DEPARTMENT
2191 BIRCH STREET
BREA, CALIFORNIA 92521
TELEPHONE C714)529-2889 OR C800)422-4133
POWER:
SOUTHERN'CALIFORNIA EDISON COMPANY
300 N. -PEPPER tSTRTEET, PO.BOX 788
RIALTO, CALIFORNIA 92376
MR. DAVE JONES
TELEPHONE=
PACIFIC TELEPHONE
,9000 HELLMAN AVE.
RANCHO CUCAMONGA, CALIFORNIA 91370
WATER
CUCAMONGA COUNTY WATER DISTRICT
9461 SAN BERNARDINO ROAD
CUCAMANGA, CALIFORNIA 91730
RECORD DRAWING
THE INFORMATION ON THIS DRAWING IS OBTAINED FROM OTHERS AND
MUST ,BE VERIFIED IN THE FIELD BY ANYONE PRIOR 1f0 USE OR
CONSTRUCTION. ADAMS 3 STREETER CIVIL ENGINEERS INC. IS NOT
RESPONIBLE FOR UNDERGROUND FACILITY LOCATION OR DEPICTIONS.
ALL ABOVE GROUND FACITIES CAN BE READILY SEEN AND VERRIED
BY THE PARTIES THAT INTEND TO USE SAME.
NO.
R/W
5'
P. U.E.
1,
S. F
5 S, 760
L -F
.27870
12$
S. F.
'I'll 045
S.. F
11130
EA.
4
S.F
5,150
L. F.
400
L. F
38
EA. 6
REVISION APPROVAL DATE APPROVAL CITY DATE
REV15ED ST. L/GA1T LOCAT/ONS PER S.C.E, /G/
ADDED ST. STA?/DN�J IG TD NEW LOCAT/ONS Roes 2-1-90 C-tG I,/�' _. Z -le*
AD021�-D IV -5,C1012-0 /NV--0,V1WA T/ON : � . NOTE Fo/? 5 20 q/ 1-4 A
Tg. /3090-i nNGy
5 5 570
3240
NOT REQUIRED 600
In ro 30 SCALE IN FEE" PA
,
NOT REQUIREDGEND
4 EXISTING
IMPROVED S TOFFY S
5 15.0 PARK
NOT REQUIRED
NOT REQUIRED
:. SARK
PARK.
R/ W ��ti��, l , S�
S;
rJ
C -• T'
P. U.E. No.25083
1 Exp. 12-31.93 *
�I I
F1,
repared in the office of:
Adams * Streeter
CIVIL ENGINEERS INC.
Adams* Streeter 15 Corporate Park
CIVIL ENGINEERS INC. Irvine, CA 92714 0714) 474-2330
� q� � . c� G -2- 89
RANDAL L. STREETER R.C.E. # 25083 DATE
MY REGISTRATION EXPIRES 12-31-89
i
INDEX MAP
NOT TO SCALE
no
O
t4
R. N 0.
no
�--•TR.NO. 13090
90-I
CITY OF FONTANA ,. CALIFORNIA
PUBLIC WORKS DEPARTMENT
Drawn by: STREET IMPROVEMENT PLANS scale:TORK SCALE
Designed by: A TITLE SHEET l . Date:
MEL TRACT NOS. 13090-1 & 13090'7--2.77-84
Checked by: G� -��G 70 % Dwg . No.
S E S Approved: J
jr_-:rC INTERIM CITY' ENGINEER R.C.E. 2.5126 1 % 7 2' 6
HIGHLAND Q�' ���`�p AVENUE
jW
II 15 W
W z
W W
z Q
,
` !��
SOUTHERN _PAS/0 W
N�
//6A:$E LINE AVENUE
//SO W
115.SOU T
R1T GE
z u < Z Y MILLER AVENUE
Ct, CL
o \
agST
FOOTHILL z Z BOULEVARD
/ cin a 0
(/
Q J
W =
W
ARROW v HIGHWAY =
PROJECT
VICINITY MAP
NOT TO SCALE
5 5 570
3240
NOT REQUIRED 600
In ro 30 SCALE IN FEE" PA
,
NOT REQUIREDGEND
4 EXISTING
IMPROVED S TOFFY S
5 15.0 PARK
NOT REQUIRED
NOT REQUIRED
:. SARK
PARK.
R/ W ��ti��, l , S�
S;
rJ
C -• T'
P. U.E. No.25083
1 Exp. 12-31.93 *
�I I
F1,
repared in the office of:
Adams * Streeter
CIVIL ENGINEERS INC.
Adams* Streeter 15 Corporate Park
CIVIL ENGINEERS INC. Irvine, CA 92714 0714) 474-2330
� q� � . c� G -2- 89
RANDAL L. STREETER R.C.E. # 25083 DATE
MY REGISTRATION EXPIRES 12-31-89
i
INDEX MAP
NOT TO SCALE
no
O
t4
R. N 0.
no
�--•TR.NO. 13090
90-I
CITY OF FONTANA ,. CALIFORNIA
PUBLIC WORKS DEPARTMENT
Drawn by: STREET IMPROVEMENT PLANS scale:TORK SCALE
Designed by: A TITLE SHEET l . Date:
MEL TRACT NOS. 13090-1 & 13090'7--2.77-84
Checked by: G� -��G 70 % Dwg . No.
S E S Approved: J
jr_-:rC INTERIM CITY' ENGINEER R.C.E. 2.5126 1 % 7 2' 6