Loading...
HomeMy WebLinkAbout1772-1GENERAL NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS ,DATED 1975. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRAC- TOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. CONTRACTOR SHALL NOTIFY THE ENGINEER 48 -HOURS PRIOR TO THE ANTICIPATED START OF OF CONSTRUCTION. 4. ALL PIPES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR POWER POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC., SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY OTHERS; IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL OF THE AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS. 5. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR. 5. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 7. ALL BACKFILL TO BE CERTIFIED BY SOILS ENGINEER. 8. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 9. BACKFILL MATERIALS TO HAVE A.S.E. OF 30 (MIN.) AND MINIMUM COMPACTION OF 90%. 10. ALL NEW OR EXISTING VALVE CANS AND MANHOLES SHALL BE ADJUSTED TO GRADE DURING PAVING . BY THE PAVING CONTRACTOR. 11. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED BY THE CITY ENGINEER. 12. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE ON EXISTING WATER LINES. 13. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE, PROPOSED IMPROVEMENTS, WORK SHALL STOP AND THE ENGINEER NOTIFIED IMMEDIATEDLY. 14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER AFTER THE BASE COURSE HAS BEEN CONSTRUCTED AND BEFORE THE PAVING HAS BEEN INSTALLED SO THAT THE ENGINEER MAY INSTALL THE STREET CENTERLINE MONUMENTS AS REQUIRED BY THE CITY CODE OF THE CITY OF FONTANA. 15. PAVEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL. OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH GRADING. PAVING NOTE ACTUAL THICKNESS OF BASE MATERIAL TO BE DETERMINED BY SOIL TEST AND RECOMMENDED BY THE SOILS ENGINEER R. VALUES, SAND EQUIVALENTS AND STRUCTURAL SECTION OF STREETS SHALL BE SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OT THE SITE. THE CITY ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR LEAVING IMPROVEMENTS. PRIVATE ENGINEER'S NOTICE i0 CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPON- SIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACT SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR .THE ENGINEER. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. BENCH MARK FUE 1 USCGS "O" STATION 'PACEL' 1963.90'± ELY. OF RAILROAD TRACKS AND 281± SLY. OF CL BASELINE. 1.1 MI. ELY. OF EAST AVENUE. SAME AS CITY B.M. #364 ELEVATION 13 01 .54' STREET IMPROVEMENT PLANS FOR TRACT NOS. 13090 & 13 090- I I N THE CITY OF FONTANA COUNTY OF SAN BERNARD I NO CONSTRUCTION NOTES QUANTITIES DESCRIPTION: TRACT N0.13090 TRACT NO. 13090-1 UNIT QUANTITY QUANTITY (D_ CONSTRUCT " A.C. OVER A.B. PAVING. (ASSUME 4" A.C. OVER NATIVE FOR ESTIMATING PURPOSES ONLY. ACTUAL PAVING THICKNESS TO BE DETERMINED PER PAVING NOTE ON SHEET 1.) 2� CONSTRUCT 6" CURB & GUTTER PER CITY STD. 101. Q ---CONSTRUCT 6" CONC. CURB ONLY PER CITY STD. 101 [MONOLITHIC WITH CROSS GUTTER) CONSTRUCT 4" THICK P.C.C. SIDEWALK PER CITY STD. 105A. - 5. CONSTRUCT CROSS GUTTER PER CITY STD. 104. 6. CONSTRUCT RAMPED CURB RETURN (WHEELCHAIR RAMP) PER CITY STD. 104-A.- D.- CONSTRUCT RESIDENTIAL DRIVEWAY PER CITY STD. 102 (W=16' MAX ; X=3') EXACT LOCATION TO BE DETERMINED AT THE TIME OF GONSTR.UCTcON (,EXACT 8�I CURB & GUTTER PER CITY STD. 101. 0--`_ CONCvTRUCT CURB TRANSITION FROM GIIC.F TO 51'C-F=- INSTALL 1'C.F.INSTALL SINGLE 5800 H.P.S. STREET LIGHT. IMPORTANT NOTICE Section 4216/4217 of the Government Code requires a DIG ALERT IDENTIFICATION NUMBER be issued before a 'Permit to Excavate' will be valid For your DIG ALERT I.D. NUMBER call Underground Service Alert TOLL FREE 1-800-422-4133 Two working days before you dig UTILITY NOTIFICATIONS SEWER CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CALIFORNIA 92335 TELEPHONE (7143350-7540 GAS: SO. CALIF. GAS COMPANY -DISTRIBUTION FACILITIES 16-231 VA LLY BLVD. FONTANA, CALIFORNIA 92335 MR. LOU WESTFALL SO. CALIF. GAS COMPANY -TRANSMISSION DEPARTMENT 2191 BIRCH STREET BREA, CALIFORNIA 92521 TELEPHONE C714)529-2889 OR C800)422-4133 POWER: SOUTHERN'CALIFORNIA EDISON COMPANY 300 N. -PEPPER tSTRTEET, PO.BOX 788 RIALTO, CALIFORNIA 92376 MR. DAVE JONES TELEPHONE= PACIFIC TELEPHONE ,9000 HELLMAN AVE. RANCHO CUCAMONGA, CALIFORNIA 91370 WATER CUCAMONGA COUNTY WATER DISTRICT 9461 SAN BERNARDINO ROAD CUCAMANGA, CALIFORNIA 91730 RECORD DRAWING THE INFORMATION ON THIS DRAWING IS OBTAINED FROM OTHERS AND MUST ,BE VERIFIED IN THE FIELD BY ANYONE PRIOR 1f0 USE OR CONSTRUCTION. ADAMS 3 STREETER CIVIL ENGINEERS INC. IS NOT RESPONIBLE FOR UNDERGROUND FACILITY LOCATION OR DEPICTIONS. ALL ABOVE GROUND FACITIES CAN BE READILY SEEN AND VERRIED BY THE PARTIES THAT INTEND TO USE SAME. NO. R/W 5' P. U.E. 1, S. F 5 S, 760 L -F .27870 12$ S. F. 'I'll 045 S.. F 11130 EA. 4 S.F 5,150 L. F. 400 L. F 38 EA. 6 REVISION APPROVAL DATE APPROVAL CITY DATE REV15ED ST. L/GA1T LOCAT/ONS PER S.C.E, /G/ ADDED ST. STA?/DN�J IG TD NEW LOCAT/ONS Roes 2-1-90 C-tG I,/�' _. Z -le* AD021�-D IV -5,C1012-0 /NV--0,V1WA T/ON : � . NOTE Fo/? 5 20 q/ 1-4 A Tg. /3090-i nNGy 5 5 570 3240 NOT REQUIRED 600 In ro 30 SCALE IN FEE" PA , NOT REQUIREDGEND 4 EXISTING IMPROVED S TOFFY S 5 15.0 PARK NOT REQUIRED NOT REQUIRED :. SARK PARK. R/ W ��ti��, l , S� S; rJ C -• T' P. U.E. No.25083 1 Exp. 12-31.93 * �I I F1, repared in the office of: Adams * Streeter CIVIL ENGINEERS INC. Adams* Streeter 15 Corporate Park CIVIL ENGINEERS INC. Irvine, CA 92714 0714) 474-2330 � q� � . c� G -2- 89 RANDAL L. STREETER R.C.E. # 25083 DATE MY REGISTRATION EXPIRES 12-31-89 i INDEX MAP NOT TO SCALE no O t4 R. N 0. no �--•TR.NO. 13090 90-I CITY OF FONTANA ,. CALIFORNIA PUBLIC WORKS DEPARTMENT Drawn by: STREET IMPROVEMENT PLANS scale:TORK SCALE Designed by: A TITLE SHEET l . Date: MEL TRACT NOS. 13090-1 & 13090'7--2.77-84 Checked by: G� -��G 70 % Dwg . No. S E S Approved: J jr_-:rC INTERIM CITY' ENGINEER R.C.E. 2.5126 1 % 7 2' 6 HIGHLAND Q�' ���`�p AVENUE jW II 15 W W z W W z Q , ` !�� SOUTHERN _PAS/0 W N� //6A:$E LINE AVENUE //SO W 115.SOU T R1T GE z u < Z Y MILLER AVENUE Ct, CL o \ agST FOOTHILL z Z BOULEVARD / cin a 0 (/ Q J W = W ARROW v HIGHWAY = PROJECT VICINITY MAP NOT TO SCALE 5 5 570 3240 NOT REQUIRED 600 In ro 30 SCALE IN FEE" PA , NOT REQUIREDGEND 4 EXISTING IMPROVED S TOFFY S 5 15.0 PARK NOT REQUIRED NOT REQUIRED :. SARK PARK. R/ W ��ti��, l , S� S; rJ C -• T' P. U.E. No.25083 1 Exp. 12-31.93 * �I I F1, repared in the office of: Adams * Streeter CIVIL ENGINEERS INC. Adams* Streeter 15 Corporate Park CIVIL ENGINEERS INC. Irvine, CA 92714 0714) 474-2330 � q� � . c� G -2- 89 RANDAL L. STREETER R.C.E. # 25083 DATE MY REGISTRATION EXPIRES 12-31-89 i INDEX MAP NOT TO SCALE no O t4 R. N 0. no �--•TR.NO. 13090 90-I CITY OF FONTANA ,. CALIFORNIA PUBLIC WORKS DEPARTMENT Drawn by: STREET IMPROVEMENT PLANS scale:TORK SCALE Designed by: A TITLE SHEET l . Date: MEL TRACT NOS. 13090-1 & 13090'7--2.77-84 Checked by: G� -��G 70 % Dwg . No. S E S Approved: J jr_-:rC INTERIM CITY' ENGINEER R.C.E. 2.5126 1 % 7 2' 6