HomeMy WebLinkAbout1756-1w
z
Q
SOUTHERN
VICINITY MAP
NOT TO SCALE
LEGEND
- - -. 71-fI4�raW�vo1Ry
' SEE SHEET
BASE UNE AVENUE
11111�� �,,,,►
F�sr
L18ERTY
I
FOOTHILL BOULEVARD
INDEX MAP
NOT TO SCALE
WWI
%-
!7 W
VILLAGE OF HERITAGE
SEWER PLANS
FOR
',TRACTS 13.1317,,13137- ="l & i393,7-2
EAST HERITAGE VILLAGE
IN THE
CITY OF FONTANA
1�` COUNTY OF SAN BERN R INO
'07
Nis CONSTRUCTION NOTES & QUANTITIES:
W
ROANOKE
ROAD
MEYER CANYON
DRIVE
�0 F E S,S'/�
0K1.
'•'-'No. M229
cc FXp 3/31/94
tr
OF C Nk_\� r
Underground "Service Alert
Call: TOLL FREE
1-800
422--4133
TWO WORKING DAYS
BEFORE YOU DIG
SANTA LUCIA STREET
TR, 13137 2
STANISLAUS COURT
RODGERS COURT TR. 13137-2
TR. 13137-Z 3
TOULUMNE COURT
TR. 13137-1
PLUMAS COURT
TR, 13137-I N.2
RECORD DRAWING — `
The information oo this drawing is obtained from others and
must bp ygrified In the field by anyono. poor to use or
con's 'lai i -Wo HALL & FOREMAM, INN. is not responsible for
tinder r e�facllity ioratiw nrdepictinns. All ahouegroond
fadlities ran he reAdily seen and verified lav the ONtios that
intend to use same
O
CONST. 8° EXTRA .STRENGTH VCP SEWER
STD.. DETAIL
N0.
.TR. 13137
TR. 13137-1
TR 13137-2
TOTAL
UNIT
566.
946
976
24F8
LF
02
CONST. 4" EXTRA STRENGTH VCP SEWER LATERAL W /PLUG
125
.769
1455
1190
3414
LF
3O
CONST. 48' PRECAST CONC. MANHOLE
109 , 112
3
3
3
9
EA
8 114
'.
� 3 �A
L` r} No. 47867 rn
Expires iwi
AURORA CONSULTING
460 SOUTH STOOOARD AVE, STE 4
SAN. BERNAROINO, CA 92401
(909) 388-4420 PHONE
(909) 884-8183 FAX URO�
C®NS�J1L..'-II,II NG
1
JO SNELL RCE No. 47867 DTE
UTILITY NOTES:
WATER: CUCAMONGA COUNTY WATER DISTRICT
9461 SAN BERNARDINO ROAD
CUCAMONGA, CA 91730
(714) 987-2591
SEWER: CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(714) 350-7640
POWER: SOUTHERN CALIFORNIA EDISON COMPANY
P.O. BOX 788
300 N. PEPPER STREET
RIALTO, CA 92376
MR. DAVE JONES
ZI/0" /ylxx
✓ELECTED
9,6VVI 1/G 4rO/k1fXe7,6-P O
TD 90
TYPICAL BEDDING FOR 8" VCP
LESS THAN 10' DEEP
N, T, S
S��ECTE� N�TivE
50/L I " /17�IX. 5/ZE
CO/YIPACTED TO 90 0/
/1•V ii V 9�� /r
IOC/< ,BEDD//
40 ""IVIAI
!O "�I,9X.
N
TYPICAL BEDDING FOR 8" VCP 10' OR DEEPER
No TI S I
GAS: SOUTHERN CALIFORNIA GAS COMPANY
16231 VALLEY BLVD.
FONTANA, CA 92335
MR. LOU WESTFALL
TELEPHONE: PACIFIC TELEPIIONE
9000 HELLMAN AVENUE
RANCHO CUCAMONGA, CA 91370
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND
THE CITY OF FONTANA PUBLIC WORKS DEPARTMENT STANDARD
SPECIFICATIONS DATED 1975.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA
PUBLIC WORKS,, DEPARTMENT PRIOR To THE START OF ANY WORK
WITHIN THE CITY LIMITS.
3. TERMINATE ALL 4" HOUSE SEWER LATERALS 8' INSIDE THE LOT WITH A PLUG.
SHOULD A PUBLIC UTILITIES EASEMENT LIE CONTIGUOUS TO THE STREET R -O -W,
THE LATERAL SHALL EXTENDACROSS THE EASEMENT AND TERMINATE 3' INSIDE
THE LOT AS MEASURED FROM THE UTILITY EASEMENT LINE.
4, ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES41,
5, ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL
TELEPHONE OR POLES, WATER METERS, VALVES, HYDRANTS,
IRRIGATION STRUCTURES, ETC. SHOWN OR NOT SHOWN ON THIS
PLAN AND LOCATED WITHIN AREAS TO BE IMPROVED AND
INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY
OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY ALL AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
6. "AS -BUILT" PLANS SHALL BE PROVIDED TO THE CITY BY THE
CONTRACTOR.
7, ALL 4" HOUSE SEWER LATERALS SMALL BE INSTALLED ON A 2%
MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY
ENGINEER.
8. SEWER CONTRACTOR SHALL CHISEL "X" IN THE CURB AT THE
LOCATION OF ALL LATERALS,
9. MANHOLE FRAMES AND COVERS TO BE CONSTRUCTED BY THE SEWER
CONTRACTOR 6" BELOW FINISHED SURFACE GRADE AND UPON
COMPLETION OF PAVING, THE PAVING CONTRACTOR SHALL RAISE
SAME TO FINISHED GRADE.
10. ALL STATIONING REFERS TO CENTERLINE OF SEWER.
1 1 . THE SEWER CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE
LOCATION AND PROTECTION OF ALL EXISTING UNDERGROUND UTILITIES
AND STRUCTURES WHETHER SHOWN ON THESE PLANS OR NOT.
12. NO LATERALS SHALL BE PLACED UNDER DRIVEWAYS.
13. ENGINEER SHALL CHECK OUT ORIGINAL SEWER IMPROVEMENT PLANS
AND TRANSFER ItASBUILT" INFORMATION PRIOR TO CITY ACCEPTANCE
OF THE SEWER SYSTEM.
/4 P,PE c,4sT To s TD. of TA/Z-
112 AND BE OES/6iS/ED FO,P ,9Shi TO h1/G1-1jvAY L DADS.
BENCH MARK FWE 1
USCGS " Q" STATION "PACEL" 1963.901+
ELY. OF RAILROAD TRACTS AND 28'+ SLY.
OF CL BASE LINE, 1.1 MI. ELY OF EAST
AVENUE, SAME AS CITY B.M. ##364
ELEVATION 1301.54'
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
CONFIRMED BY THE CONTRACTOR SO THAT ANY NECESSARY ADJUSTMENTS CAN BE
MADE IN ALIGNMENT AND/OR GRADE OF PROPOSED IMPROVEMENTS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT
ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT
SHOWN ON THESE PLANS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM
ANY AND ALL L/! B/L./Ty EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR THE ENGINEER.
rkin,UnLIABLoh FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL
CHANGES MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF K[�-60fzl)
THESE PLANS. 14,IVO BY 7-112 C/TY ENG/NEE-FF
C IY 0 F FO N I ANACALIF-0 RNIA
PUBLIC WORKS DEPARTMENT
E���QN
DRAWN BY
��� SEWER PLANS SCALE:
�•�o � ANS
+ o fVN ♦ R.W. INDEX HORIZ.:Its=40�
`�' 3170 REDHILL AVENUE - COSTA MESA, CA 92626-3428 • (714) 641-8777 DESIGNED BY G E N.E R A L NOTES, CONST N0TES VERT.: I"=4'
3_ -" CIVIL ENGINEERING LAND PLANNING - LAND SURVEYING
t��.CHECKED
UNDER THE SUPERVISION OF: BY TRACT 13137 N TR I3 137 -
JCH AND TRACT 1 1 7 2
NCA
RECORV Dr?AIiY//VG S%f�7!15Ce ft—�8 90 - 4^ Q J 0 B N 0. DR. NO. S H T. NO.
GR S. CITY � � APPROVED -� �/�6q
Oi C p1
N0. REVISIONS APPROVAL DATE APPRO A D TE J H C. HOGAN R.C.E. 26229 DATE 3825.137 1~zC INTERIM CITY ENGINEER R.C.E, 2612G 11 1 OF5