HomeMy WebLinkAbout1626-1Z)
z
W
Q
SOUTHERN
VICINITY MAP_
NOT TO SCALE
LEGEND
10 = SHEET NUMBER
&_)!!. LINCOLN LOOP RD.
(D -L.
INDEFENOENCE WAY
5� UTION WAY
_ - - FOOTHILL - - BOUEVARD
INDEX MAP
1 11 = 800 1
VILLAGE OF HERITAGE
STREET IMPROVEMENT PLANS
FOR
TRACT. 13000- 3
EAST VILLAGE 'BACKBONE
N IN THE
Q CITY OF FONTANA
CARYN CIRCLE 18
FRANKLIN ST,
LINCOLN LOOP R0. 15
MEYER CANVt
MlvE
SANTA MARIA DR, �,
COUNTY OF SAN BERN R INO
CONSTRUCTION NOTES & QUANTITIES.
DESCRIPTION
CITY OF FONTANA QUANTITY
STD. DETAIL No.
lO
CONST. 811 CURB a GUTTER
101
24325 L.F
OCONST.
611 TO 811 CURB & GUTTER
101
670 L. F.
OCONST.
CON C. SIDEWALK
PER STD. SPE CI FICATIONS
106,202 L. F.
OCONST.
611 TO 8'1 TRANSITIONAL CURB
1 0 1
37250 L. F.
OCONST.
411 A.iC.OVER 1211 COMPACTED NATI VE
11
540,117 L. F.
O6
CONST. WHEELCHAIR RAMP
104A
Q 150 EA..
7O
CONST CROSS GUTTER
105
22,920 S. F.
8
8" CURB ONLY
101_
34 L. F.
11
OP fTOAITANA PCTAIL- O�(/WALL � Olr
AV . 7- 6 � � =-D ,�l/Gy
258 L.F.
it
9500 H P S STREET LIGHTS ;
2
43 EA.
NOTE:
ALL CATCH BASINS AND LOCAL DEPRESSIONS SHOWN ON THESE PLANS
SHALL BE CONSTRUCTED AS PART OF THE STORM DRAIN PLANS.
LANDSCAPING
STREET TREES AND LANDSCAPING WITHIN PUBLIC RIGHT-OF-WAY SHALL BE PER
FONTANA WEST END SPECIFIC PLAN AND LANDSCAPE ARCHITECT'S PLAN.
UTILITY NOTES:
WATER:, CUCAMONGA COUNTY WATER DISTRICT GAS:
9461 SAN BERNARDINO ROAD
CUCAMONGA, CA 91730
(714) 987-2591
SEWER: CITY OF FONTANA TELEPHONE:
8353 SIERRA AVENUE
FONTANA, CA 92335
(714) 350-7640
POWER: SOUTHERN CALIFORNIA EDISON COMPANY
P.O. BOX 788
300 N. PEPPER STREET
RIALTO, CA 92376
MR. DAVE JONES
13\_ RE -CORD DRAWING
The information on this drawing is obtained from others and
must be verified in the field by anyone prior to use or
construction. HALL & FOREMAN, INC. is not responsible for
underground facility locations or depictions. All above ground
facilities can be readily seen and verified by the parties that
intend to use same,
4 PA V/NO 1101"E
/F /'A VItVG IS /�V .2 5,5P4R,4 TE LI CrS.
CONTlIA CJQ,R 54OZ L AL LON FOR ? PX I//NG ili10VF -/AIS .
F/QST �ROyza -/N FOR 3" ,6AS'5 P4 XC- � SECOND 'MOVE 1,V
70 INCLUDE CL&IVIA/G, TGC/C COAT ANO 041//N6 C.4P .
WVAl /f9EMT SECT1041S Sh'Dly,(/ ,q,QE
SUB✓E'CT TQ /RE!//S/O/t/ qND �f'f'ir0//�iL D� Tf1E C/Ty
4S lf'EQU/,QEp BY SO/[S TEST ` X!V*Zi1 A/--_7ZW CO/YIPLET/ON
6_177/4_1 Tfi'/C"_1'5- S OF BASF/1lATE,P/fJL TD BE U�TE/r'/YJ//YED BY SO/G
TEST A/YD BY TW,-- s0/LS EN6/WEER /P. !/4_1[/5.5',
5,4/ti0 EQC//!/fiLE/1/TS ,qlYD OF _577�PEETS
51%4 L A$- sUi9/Yl/JlEQ TO T/1G' C/TY OF FOii/T9i!/,Q FOiP Af'�,201/r¢G
(�POi(/ 50MPGE-T/o�ti OF .?oU4y �',Q,qp/�/G,
e f ,6- SHO ULD BE T,9KEN TO P/r'E!/E�t/ T Firf37O�S, D/TCh�ES A/YD
SG I&Z-S A;P i9lw !, lPVZ .Qili1411/y� ST/QEE T /�JiJP�QO!/EiY1E/YTS
64000/11 /iYSlll�reTi0i11 0.4 7_114-:7- .siTE; T.i',-d' ci77Y E/YFi//YEE,Q
/Ll.4Y ,QG�QU/f�E TE"i1/IPOT{,�,QY y Urt//TE' SIYALE'S� Ei/iT�.%/6
Olf:, LEAD/iyy� /iJ7f'�POI��/ylE/YTS .
SOUTHERN CALIFORNIA GAS COMPANY
16231. VALLEY BLVD.
FONTANA, CA 92335
MR. LOU WESTFALL
STREET LIGHT LEGEND
5O,0�� PS STREET LIGHT�Al
rtN�Y . � � a � t , �•
PACIFIC TELEPHONE �.
9000 HELLMAN AVENUE
RANCHO CUCAMONGA, CA 91370
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND THE CITY OF
FONTANA PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS DATED, 1975.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS
DEPARTMENT PRIOR TO THE START OF ANY WORK WITHIN THE CI'<'Y LIMITS.
3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE '.VHE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
4. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPHONE OR
POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETC.
SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE
IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY
- OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL
AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
5. WATER VALVE COVERS SHALL BE RAISED TO GRADE BY THE PAVING CONTRACTOR.
6. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
7. ALL UTILITY COMPANIES SHALL BE GIVEN 48 HOURS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
8. ALL BACKFILL TO -BE CERTIFIED BY SOILS ENGINEER.
9. ALL MATERIALS AND METHODS TO BE SUBJECT TO THE APPROVAL OF THE CITY
ENGINEER.
10. BACKFILL MATERIALS TO HAVE A S. E. OF 30 (MIN.) AND MIN. COMPACTION OF
90%.
11. ALL NEW OR EXISTING VALVE CANS AND MANHOLES SHALL BE ADJUSTED TO
GRADE DURING PAVING.
12. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AND STRIPING AS REQUIRED BY
THE CITY ENGINEER.
13. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE.
14. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE
PROPOSED IMPROVEMENTS, WORK SHALL STOP AND THE ENGINEER NOTIFIED
IMMEDIATELY.
15. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE
ENGINEER AFTER THE BASE COURSE HAS BEEN CONSTRUCTED AND BEFORE THE
PAVING HAS BEEN INSTALLED SO THAT THE ENGINEER MAY INSTALL THE STREET
CENTERLINE MONUMENTS AS REQUIRED BY THE CITY CODE OF THE CITY OF
FONTANA.
16. THE LANDSCAPE ARCHITECT MUST INSPECT ALL MEANDERING SIDEWALK LOCATIONS
PRIOR TO CONSTRUCTION,
------ moi' ,
CAUTION: THE ENGINEER PREPAR II4G----9fi� - PLANS WILL NOT BE RESPONSIBLE
Po,OR—LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL
CHANGES MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF
THESE PLANS.
BENCH MARK FWE 1
USCGS 11/,11 STATION "PACEL" 1963.901+
ELY. OF RAILROAD TRACTS AND 28'+ SLY.
OF CL BASE LINE, 1.1 MI. ELY OF EAST
AVENUE, SAME AS CITY B.M. ##364
ELEVATION 1301.54'
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
CONFIRMED BY THE CONTRACTOR SO THAT ANY NECESSARY ADJUSTMENTS CAN BE
MADE IN ALIGNMENT AND/OR GRADE OF PROPOSED IMPROVEMENTS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT
ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT
SHOWN ON THESE PLANS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM
ANY AND ALL PROJECTS, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF THE OWNER OR THE ENGINEER.