CONSTRUCTION NOTES 15 QUANTITIES:
DESCRIPTION CITY OF FONTANA QUANTITY
STD. DETAIL NO.
lO
CONST.
6" CURB Ilk 6UTTE R
101
ZSOG
LF
O
CONST.
RESIDENTIAL DRIVEWAY W = 16'
102
_-.�3f
SF
3O
CONST.
CONC. SIDEWALK
PER STD. SPE CI FICATIONS
PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
SF
O
CONS T.
a" A.C. OVER 12" COMPACTED NATIVE
"
_ I/S��f� p
SF
O
CONST.
CROSS GUTTER
IDS
Pd'Z'
SF
a6
CONST.
WHEELCHAIR RAMP
104A
4
EA
O7
CONST.
CONC. CURB ONLY (6" CF) ,1r CQ's
101
90�F
8Q
CONST. d
CURB E GUTTER
101
zV
LF
(714) 350-7640
TO , BE
LOCATED IN FIELD.
POWER: BOUThERN CALIFORNIA EDI SON COMPANY
COA46T.
TRAN13. CUR15 0 -- b* C.F.
��' 101
3 ; ��, 31
LF
LIABLE FOR,
0-0
SINGLE 5,800 MPS STREET LIGHT
300 N. PEPPER STREET
d
EA
APPROVED BY THE PREPARER OF
RIALTO, CA 02376
THESE PLANS AND B'Y
THE CITY ENGINEER.
MR. DAVE JONES
O
NOTE
ALL CA'T'CH BASMS AND LOCAL DEPRESSION'S SHOWN ON THESE PLANS
SHALL BE CONSTRUCTED AS PART OF THE STORM DRAIN PLANS.
IGLpMAL 'NOTES
1. ALL WORE BRALL BE DONE IN ACCORDANCE WITH THM PLA" An TRI CITY OF
FONTANA PUBLIC WORKS DEPARTMENT STANDARD SPECIFICATIONS DATED, 1973.
2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE FONTANA PUBLIC WORKS
DEPARTMENT PRIOR TO THE START OF ANY WORK WITHIN THE CITY LIMITS.
3. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTTRACT02
TO CONSTRUCT THE WORK TO THE PLAN GRADES.
4. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND AND ALL TELEPRONR OM
POLES, WATER METERS, VALVES, HYDRANTS, IRRIGATION STRUCTURES, ETI.
SHOWN OR NOT SHOWN ON THIS PLAN AND LOCATED WITHIN AREAS TO BE
IMPROVED AND INTERFERING WITH CONSTRUCTION, SHALL BE RELOCATED BY
OTHERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL
AGENCIES CONCERNED BEFORE CONSTRUCTION BEGINS.
S. WATER VALVE COVERS SHALL BE RAISED TO GRADE BY THE PAVING CONTRACTOR.
6. AS -BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.
7. ALL UTILITY COMPANIES SHALL BE GIVEN 418 HOURS LVOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
S. ALL BACKFILL TO. HE CERTIFIED BY SOILS ENGINEER.
9. ALL MATERIALS AILD METHODS TO BE St1BJECT TO THE APPROVAL OF "M CI T'
ENGINEER.
10. BACKFILL MATERIALS TO HAVE A S.E. OF 30 (MIN.) AND illi. COMPACTION OF
90%.
11. ALL NEW OR EXISTING VALVE CANS An VAN' MES SMALL BE ADJUSTED !`A
GRADE DURING PAVING.
12. CONTRACTOR TO INSTALL PAVEMENT MARKINGS AIM STRIPING AS REQDIR9D BY
THE CITY ENGINEER.
13. CONTRACTOR SHALL NOT OPERATE ANY MAIN LINE WATER VALVE.
14. IF EXISTING UTILITIES OR Alit OTHER FACILITIES CON`FL I CT AI'TN THS
PROPOSED IMPROVEMENTS, WORD SHALL STOP AND THE ENGINEER NOTIFIED
IMMEDIATELY.
15. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE
ENGINEER AFTER THE BASE COURSE HAS BEE! CONSTRUCTED AND BEFORE TWE
PAVING HAS BEEN INSTALLED SO THAT THE ENGINEER MAY INSTALL THE STREET
CENTERLINE MONUMENTS AS REQUIRED BY THE CITY CODE OF THE CITY OF
FONTANA.
PAVING NOTE
ACTUAL THICKNESS OF BASE MATERIAL TO BE DETERMINED BY BOIL TESD' ANIS
RECOMMENDED BY THE SOILS ENGINEER.R VALUES, SAND EQUIVALENTS AND
STRUCTURAL SECTION OF STREETS SHALL BE SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES AND SMALE8"FROW
UNDERMINING STREET IMPROVEMENTS.UPON INSPECTION OF THE SITE, THE CITY
ENGINEER MAY REQUIRE TEMPORARY GUNITE SWALES, ENTERING OR LEAVING
IMPROVEMENTS.
BENCH MARK FWE 1
USCGS "A" STATIO19 "PACEL" 1983.90'
ELY. OF RAILROAD TRACKS AND 28'+ SLY.
OF CL BASE LINE, 1.1 MI. ELY OF -EAST
AVENUE, SAME AS CITY B.M. #364
ELEVATION_ 1301.54'
LANDSCAPING 'RECORD D R A W I N G PRIVATE ENGINEER'S NOTICE TO CONTRACTOR
The information nn this t1rawinp ix ohtainoM frpm othprS and THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR
STREET TREES AND LANDSCAPING WITHIN PUBLIC RIGHT-OF-WAY SHALL BE PER � must he verified in the fieri h an �n� prior t
FONTANA HEST END SPECIFIC PLAN AND LANDSCAPE ARCHITECT'S PLAN. Y y P p use Or STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE
construction. HALL & FOREMAN, INC. is not responsible for AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE
underground facility locations or depictions. All above ground CONFIRMED BY THE CONTRACTOR SO THAT ANY NECESSARY ADJUSTMENTS CAN !(E
facilities can be reaft seen and verified by the parties that MADE IN ALIGNMENT AND/OR GRADE OF PROPOSED IMPROVEMENTS. THE
intend to use same. CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT
ANY UTILITY LINES SHOWN AND ANT OTHER LINES NOT ON RECORD OR NOT
UTILITY NOTES: �%' �.,....r% SHOWN ON THESE PLANS.
��QROIESS�p�F CONTRACTOR AGREES THAT HE SHALL ASSUME SOLI! AND COMPLETE
RESPONSI IT
WATER: CUCAMONGA COUNTY WATER DISTRICT
GAS; SOUTHERN CALIFORNIA GAS COIVIPAIIT
Z`�;o
BIL Y FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT,
9461 SAN BERNARDI73 ROAD
16231 VALLEY BLVD.
pQ�OFESS��N9�
��'
Ci
INCLUDING SAFETY OF ALL PERSONS AND
CUCAMONGA , CA 91730
FONTANA, CA 92335
�.C�RTh'p �`
��
GTy
�+ 262" =
PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
(714) 987-2591
MR. LOU WESTFALL.�
r., ��
No. 26229
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALT,
�
4<
DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM
SEVER: CITY OF FONTANA
TELFPHONE: PACIFIC TELEPHONE
Exp. 3/31/98*
s�
/Vii
ANT AND ALL LI�161 LITY, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE
8353 SIERRA AVENUE
9000, HELLMAN AVENUE
C ` �Q-
'9TF BVI 0��
��.
qjE pj CAl�FO��
NEGLIGENCE OF THE OWNER OR THE ENGINEER.
FONTANA, CA 92335
RANCHO CUCAMONGA, CA 9137-
OF CALOR
(714) 350-7640
POWER: BOUThERN CALIFORNIA EDI SON COMPANY
CAUTION: THE ENGINEER PREPARING THESE
PLANS WILL NOT BE RESPONS I BLE
P.O. BOX 788
LIABLE FOR,
UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALLx
300 N. PEPPER STREET
CHA-NGES MUST BE IN
WRITING AND MUST BE
APPROVED BY THE PREPARER OF
RIALTO, CA 02376
THESE PLANS AND B'Y
THE CITY ENGINEER.
MR. DAVE JONES
CITY OF' FONTANA CALIFORNIA
PUBLIC WORKS DEPARTMENT____,
DRAWN BY STREET IMPROVEMENT PLANS SCALE:
ER
A14ORIZ.: 1"0'40
3170 REDHILL AVENUE COSTA MESA, CA 92626-34M (714) 641-8777
DESIGNED GENERAL NOTES, CONST. NOTES VERT: I"=4'
KW
�• �� -1- CML ENGINEERING LAND PLANNING LAND SURVEYING CHECKED BY DATE:
AI L��ft�s 6W-0 �`f PREPARED UNDER THE SUPERVISION OF: CH TRACT [ 3091 ?//
9%8�
aoa' car. A , AXa, r,eM=f /Vr r 27 g JOB NO.
E R S. CITY 1.� " �'�- APPROVED �lVA_ DR. NQ SHT. N0.
NO. REVISIONS P R V DATE APPR DATE OHN C. MOGAN R.C.E. 2622! ATE 8M-091 C. /i64B . � OF 4