Loading...
HomeMy WebLinkAbout1396-11517 w � I z 0 I z U Q Q s1 oVER Q ki WJZ/RMA QUANTITY � a Z CONSrR!/Cr 2 % "A. C. OMCR /2" COMPAC.TE,D /YA7''1Ve 50/L RE's TH/S 7,eA CT' 2.5' Q.5' RRA SNE /0, k/F /O' IMSRS/DE I AVE/YUE U S. HWy /0 AVEnUE AVE/YU.6 CA/YYO/Y CREST 0/?/VE LOCATION MAP. NOT TO SCALE PROc/ECT S1 TE INDEX MAP= STREET IMPROVEMENT PLANS TRACT NO,. 12695 FONTANA CALIFORNIA `tp 84,�aA, �s 4 V) a 6: No. 15857 '�©��1aae,���i��b e 510' R/W TYPICAL STREET SECTION N. {: T S. Rlw /S' 3S' QUANTITY UNIT / CONSrR!/Cr 2 % "A. C. OMCR /2" COMPAC.TE,D /YA7''1Ve 50/L RE's TH/S 7,eA CT' 2.5' Q.5' 8' /0, k/F /O' 25"' 2 310 1 � . 2110 ,c.F /O' 8' �4S' 2.5' 5, CON.57"e!/C7--1,0" 7771'/CAC C011Ch'E7,26 S/oQE A1X 1' 1,0771 QiY,O L0CA7'10N /:�R FLAN. LEVEL LI//E //4 0.10' '20 0./0 i PER J' 8 A,0-/US7- IVAN�OG,6�' COYE2S 7O CRAOff PFe ,DESA/L /09 0.071 0.20' o ao CIYSTieZIC r /?A/rIF'E,0 CellFO /6 67-aRN PSR ClTlf- o= FON7A/YX .5rA/Y/ 141eZ2 OE'T,1/1- A . 0.20' §10E 4° 4A, io ,P, tov� Ex/.5ri/Y(F c41R-0 ¢e Slope/_/ -----oo----- 260 ---_ — -- '' '' @ -$AW, cr.170'ANv A�/Yla;1,E ,,6-X157//ya SPANDRf L L /00 s/' CONS TR/CT CONMfRCIA L /9RIVZ'NAY PER C/TY Of A0N7ANA STD. OfT. /0?- o---- EA . SIMNA l , • S,DEWALX Z A•C. PAVEINEIYT ,,, 3 (o"Cf. CURB I GUTTER le" COMPACTED-6"C.f. CURB L cl/%rER TC. _ � -0,07'� NATIVE SOIL TC. = 0./0 ' ¢ --0.57 Ft. - ¢ - 0.57' TYPICAL STREET SECTION N. {: T S. Rlw /S' 3S' QUANTITY UNIT / CONSrR!/Cr 2 % "A. C. OMCR /2" COMPAC.TE,D /YA7''1Ve 50/L RE's TH/S 7,eA CT' Sp i CO ..57"2(/Cr CONCRE7",6 CllleO AND 6d7-7'eR CirY OF FON74f/A .57ANDAR,O DEiA/L /O/J. 4 440 k/F 25' 25"' 2 310 1 � . 2110 ,c.F /O' 8' �4S' 2.5' 5, CON.57"e!/C7--1,0" 7771'/CAC C011Ch'E7,26 S/oQE A1X 1' 1,0771 QiY,O L0CA7'10N /:�R FLAN. 28970 //4 0.10' '20 f/EAA�,e .20 0.10 PER J' 8 A,0-/US7- IVAN�OG,6�' COYE2S 7O CRAOff PFe ,DESA/L /09 I ,' ER I leA . 9 ' CIYSTieZIC r /?A/rIF'E,0 CellFO /6 67-aRN PSR ClTlf- o= FON7A/YX .5rA/Y/ 141eZ2 OE'T,1/1- A . 7 4A, io ,P, tov� Ex/.5ri/Y(F c41R-0 ¢e 32 ,t.F U 3 �i2"co/rrPAcrED r`�-s� �/YJ,�ievY ?'1�NT'S' LONG VIEW DRIVE ( 39+ 74.23 TO STA 40 + 90.40) TYPICAL STREET SECTION NOT TO SCALE CONSTRUCTION NOTES AND QUANTITY ESTIMATES NO -1 ITEM QUANTITY UNIT / CONSrR!/Cr 2 % "A. C. OMCR /2" COMPAC.TE,D /YA7''1Ve 50/L //9, 700 S.F. CO ..57"2(/Cr CONCRE7",6 CllleO AND 6d7-7'eR CirY OF FON74f/A .57ANDAR,O DEiA/L /O/J. 4 440 k/F 3 CO&VTiet/C r. CONCRC7-E C!/2,O 4N,O O!/T7'E2 ('8 "C. F. Pee crrr of =0NrA1YA SrANOAR,o 4E7,411- /o/..) 2 310 z. F 4 coNs7,1vz1cr coNc2F'7:6r cl2,a Allo oarrER lW "a= 7-iPANS/7'/0/Y rO 8 "C,F Oele C/Tf'0,=F01YX41YX 940 46T/0 2110 ,c.F C-0&97R41C7- srA/YO.A,ev Ceos5 Gur7-iFle A/YV SrAf/,2XY PSR C17 -Y OF --01V7,-41%1A .5 ,4110ARV 0=-7X-11- /04, 870 5, CON.57"e!/C7--1,0" 7771'/CAC C011Ch'E7,26 S/oQE A1X 1' 1,0771 QiY,O L0CA7'10N /:�R FLAN. 28970 51� % An -14/S7,- VA,L ve cOYEie.S 7'O /ze'YY OiEAae 8 A,0-/US7- IVAN�OG,6�' COYE2S 7O CRAOff PFe ,DESA/L /09 7 leA . 9 ' CIYSTieZIC r /?A/rIF'E,0 CellFO /6 67-aRN PSR ClTlf- o= FON7A/YX .5rA/Y/ 141eZ2 OE'T,1/1- A . 7 4A, io ,P, tov� Ex/.5ri/Y(F c41R-0 ¢e 32 ,t.F 260 ..F. @ -$AW, cr.170'ANv A�/Yla;1,E ,,6-X157//ya SPANDRf L L /00 s/' CONS TR/CT CONMfRCIA L /9RIVZ'NAY PER C/TY Of A0N7ANA STD. OfT. /0?- / EA . �K #07t: TRA115171011 00F5 //OT CfIANGE T VICAL STREET SECT/011 HEMA//YS PfR _-STA11DARD SHOWN A50VE ( FL, = -0.57') GRADE ORAJTE OCC(IRS 0/Y CUR/9 _ PROFILE 01YL Y . GENERAL CONSTRUCTION NOTES 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD -SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. CURB DATA REFERS TO THE FACE OF THE CURB. 5. ALL EXPOSED CONCRETE SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 6. PAVEMENT SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY AS REQUIRED BY SOILS TEST TAKEN AFTER COMPLETION OF ROUGH GRADING. 7. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 8. EXISTING UNDERGROUND UTILITIES ARE AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. CONTRACTOR SHALL CALL EACH UTILITY PRIOR TO ANY WORK. 9. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED 1'0 GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 10. ALL VALVE CANS AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY WATER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 11. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 12. THE CONTRACTOR(S) SHALL COORDINATE CONSTRUCTION WITH ALL.UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 13. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 14. TYPE, LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM WITH THE CITY OF FONTANA STANDARD DETAILS. 15. CONTRACTOR IS INSTRUCTED TO REFER TO THESE PLANS AND THE SPECIFICATIONS, AND WHERE THERE IS OR MAY BE A CONFLICT SHALL IMMEDIATELY REPORT SAID CONFLICT OR POSSIBLE CONFLICT TO THE OWNER'S REPRESENTATIVE. 1.6. STERILANT REQUIRED UNDER ALL A.C. PAVEMENT 17. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO ALL ADJOINING CURBS AND SIDEWALKS. 48. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAS BEEN PLACED, INSPECTED AND APPROVED. 19. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 20. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY'S INSPECTOR. 22. AS BUILT PLANS SHALL BE PROVIDED TO THE CITY BY THE CONTRACTOR.-