Loading...
HomeMy WebLinkAbout1335-191517 U.S. HWY. /0 PROJECT SITE VICINITY MAP NO SCALE li 10 N 0 N.T. S. wool— I i .000001,/ SEWER IMPROVEMENT PLANS TRACT N0. 12687 FONTANA, CALIFORNIA PJE� CONSTRUCTION NOTES AND QUANTITY ESTIMATES NUMBER ITEM QUANTITY OINSTALL STANDARD MANHOLE PER CITY 5 OF FONTANA STANDARD DETAIL 112 n2 INSTALL STANDARD CLEAN-OUT PER CITY 2 OF FONTANA STANDARD DETAIL 125 3O INSTALL 811EXTRA STRENGTH VITRIFIED CLAY PIPE 1,696 PER CITY OF FONTANA STANDARDS. AND SPECIFICATIONS PRIVATE ENGINEERS NOTICE TO CONTRACTOR OINSTALL 411SEWER LATERAL PER CITY OF FONTANA 1,702 STANDARD DETAIL 125 GENERAL NOTES 1. THE CONSTRUCTION OF ALL'PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 5. EXISTING UNDERGROUND UTILITIES ARE AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 6. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. 8. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 9. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES. 10. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, STREET CENTERLINE MONUMENTS, OR BENCH MARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT. 12. ALL MANHOLE AND CLEANOUT FRAMES AND COVERS SHALL BE CONSTRUCTED 611 BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 13. ALL 4" HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. INSTALL SEWER CLEANOUT BOX FOR ALL HOUSE LATERALS PER STD. 125-A. 14. TERMINATE ALL 411 HOUSE SEWER LATERALS AT THE PROPERTY LINE WITH A PLUG: 15. CHIS. X SHALL BE'PLACED ON THE CURB OVER LOCATIONS OF SEWER LATERALS BY 'THE SEWER CONTRACTOR. 16. IT SHALL BE THE CONRACTOR'S RESPONSIBILITY TO VERIFY THE HORIZONTAL LOCATION AND VERTICAL ELEVATIONS OF ALL UTILITY CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWER. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO CONSTRUCTION. 17. -CONTRACTOR SHALL NOTIFY CHINO BASIN MUNICIPAL WATER DISTRICT (CMBWD) TELEPHONE NO. (714) 987-17121 AT LEAST 24 HOURS PRIOR TO STARTING CONSTRUCTION. 18. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY: . CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CALIFORNIA 92335 TELEPHONE (714) 350-7610 SO. CALIF. GAS COMPANY - DISTRIBUTION FACILITIES PRIVATE ENGINEERS NOTICE TO CONTRACTOR 570 4TH STREET, P.O.'BOX 6226 SAN BERNARDINO3 CALIFORNIA 92408 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR TELEPHONE (7.14) 884-9411 OR (800) 422-4133 OTHERS, AND THOSE SHOWN ON THE RECORDS EXAMINED ARE SHOWN WITH SO. CALIF. GAS COMPANY - TRANSMISSION DEPARTMENT THEIR APPROXIMATE LOCATION AND EXTENT, 2191 BIRCH STREET BREA, CALIFORNIA 92621 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE TELEPHONE (714) 529-2889 OR (800) 422-4133 NATURE OF EXISTING GROUND AND/OR THE FINISHED GRADE IN THE SOUTHERN CALIFORNIA EDISON COMPANY VICINITY OF THE PROPOSED CONSTRUCTION AREA IMMEDIATELY PRIOR TO 1351 E. FRANCIS AVENUE, P.O. BOX 513 CONSTRUCTION. ONTARIO, CALIFORNIA 91761 TELEPHONE (714) 947-2996-- UNDERGROUND POWER 3. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO (714) 875-5100 - TRANSMISSION PROTECT THE UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL (213) 637-1233 - PIPELINES, OR BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE (800) 422-4133 UTILITIES.OR STRUCTURES CONCERNED BEFORE STARTING WORK. GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE 4. THE CONTRACTOR SHALL UNCOVER ALL UTILITIES THAT HE MAY BE JOINING, POMONA, CALIFORINA 91766 CROSSING OR PARALLELING PRIOR TO ANY CONSTRUCTION TO VERIFY BOTH TELEPHONE (213) 357-2257 OR (800) 422-4133 HORIZONTAL AND VERTICAL LOCATIONS. ANY CONFLICT OR DISCREPANCY SAN BERN. COUNTY FLOOD CONTROL DISTRICT SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO 825 EAST THIRD STREET CONSTRUCTION, OTHERWISE THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY SAN BERNARDINO, CALIFORNIA 92408 FOR ANY COSTS OF RELOCATION OR ADDITIONAL COSTS OF CONSTRUCTION. TELEPHONE C714) 383-1665 PACIFIC TELEPHONE 8 TELEGRAPH COMPANY Us a. 1.� ��+rSS!; 3073 ADAMS STREET y RIVERSIDE CALIFORNIA 92504 TELEPHONE (714) 359-2585 OR (800) 422-41331 No. 14375OF civi