Loading...
HomeMy WebLinkAbout1332-191517 U.S. HWY. /0 PROJECT SITE VICINITY MAP -0�0�� NO SCALE SCALE: I"= 100' BENCH MARK RR SPIKE ON PP# 674320E AT THE INTERSECTION OF JURUPA AVENUE AND MULBERRY AVENUE ELEV. 918.40' SEWER IMPROVEMENT PLANS TRACT N0. 12688 - I FONTANA, CALIFORNIA BASIS OF BEARING PRIVATE ENGINEERS NOTICE TO CONTRACTOR 1. ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS, AND THOSE SHOWN ON THE RECORDS EXAMINED ARE SHOWN WITH THEIR APPROXIMATE LOCATION AND EXTENT. 2. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE NATURE OF EXISTING GROUND AND/OR THE FINISHED GRADE IN THE VICINITY OF THE PROPOSED CONSTRUCTION AREA IMMEDIATELY PRIOR TO CONSTRUCTION. 3. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES FOUND AT THE SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK. 4. THE CONTRACTOR SHALL UNCOVER ALL UTILITIES THAT HE MAY BE JOINING, CROSSING OR PARALLELING PRIOR TO ANY CONSTRUCTION TO VERIFY BOTH HORIZONTAL AND VERTICAL LOCATIONS. ANY CONFLICT OR DISCREPANCY SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO CONSTRUCTION, OTHERWISE THE CONTRACTOR ACCEPTS FULL RESPONSIBILITY FOR ANY COSTS OF RELOCATION OR ADDITIONAL COSTS OF CONSTRUCTION. THE BEARINGS SHOWN HEREON AFtZ- BLED UPON THE CENTER LINE OF LIVE OAK AVE. AS SHOWN ON TRACT NO. 12064-2 M.B. 176/78-97 RECORBS OF SAN BERNARDINO COUNTY AS N. 13 1311311E. / "MAX/M16V S/ZO S,04E•C7,'6D NAr/YE ,¢EDD/NG co/r mcrev ro oo CONSTRUCTION NOTES AND QUANTITY ESTIMATES. NUMBER ITEM QUANTITY UN IT 1 INSTALL STANDARD MANHOLE PER CITY 8 EA. OF FONTANA STANDARD DETAIL 112 2 INSTALL STANDARD CLEAN—OUT PER CITY 2 EA. OF FONTANA STANDARD DETAIL 125 3 INSTALL 811 EXTRA STRENGTH VITRIFIED CLAY PIPE 11740 L.F. PER CITY OF FONTANA STANDARDS AND SPECIFICATIONS 4 INSTALL 411 SEWER LATERAL PER CITY OF FONTANA 22389 L.F. STANDARD DETAIL 125 THE BEARINGS SHOWN HEREON AFtZ- BLED UPON THE CENTER LINE OF LIVE OAK AVE. AS SHOWN ON TRACT NO. 12064-2 M.B. 176/78-97 RECORBS OF SAN BERNARDINO COUNTY AS N. 13 1311311E. / "MAX/M16V S/ZO S,04E•C7,'6D NAr/YE ,¢EDD/NG co/r mcrev ro oo TYPICAL BEDDING FOR 8" VCP LESS THAN 10' DEEP NO SCALE 13OIZ T " IWI536R ZrN6/NC,fRIA16 CON&& TSI N75 I INC. Co /27 /8,9 TR No• /2Ga& L� 0 2/6J.0 7 sEAvFR L,1 0 0 riDnl ,`0 1Z Z oTS _ .35.9VD JG REV. DATEI DESCRIPTION APP, GENERAL NOTE S 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC. WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 5. EXISTING UNDERGROUND UTILITIES ARE, AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 6. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF,THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. 8. ALL MANHOLE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 9. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES. 11. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, STREET CENTERLINE MONUMENTS, OR BENCH MARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT. 13. ALL 411 HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. INSTALL .SEWER CLEANOUT BOX FOR ALL HOUSE LATERALS PER STD. 125-A. 14. TERMINATE ALL 4" HOUSE SEWER LATERALS WITH A PLUG AT THE PROPERTY LINE UNLESS OTHERWISE NOTED. 15. CHIS. X SHALL BE PLACED ON THE CURB OVER LOCATIONS OF SEWER LATERALS BY THE SEWER CONTRACTOR. 16. IT SHALL' BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE HORIZONTAL LOCATION AND VERTICAL ELEVATIONS OF ALL UTILITY CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWER. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO CONSTRUCTION. 17. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED T0, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY: CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CALIFORNIA 92335 TELEPHONE (714) 350-7610 SO. CALIF. GAS COMPANY - DISTRIBUTION FACILITIES 570 TH STREET, P.O. BOX 6226 SAN BERNARDINO, CALIFORNIA 92408 TELEPHONE (714) 884-9411 OR (800) 422-4133 SO. CALIF. GAS COMPANY - TRANSMISSION DEPARTMENT 2191 BIRCH STREET BREA, CALIFORNIA 92621 TELEPHONE (714) 529-2889 OR (800) 422-4133 SOUTHERN CALIFORNIA EDISON COMPANY 1351 E. FRANCIS AVENUE, P.O. BOX 513 ONTARIO, CALIFORNIA 91761 TELEPHONE (714) 947-2996 - UNDERGROUND POWER (714) 875-5100 - TRANSMISSION ( 213) 637-1233 — PIPELINES, OR (800) 422-4133 GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE POMONA, CALIFORNNA 91766 » TELEPHONE (213) 357-2257 OR (800) 422-4133 s` SAN BERN. COUNTY FLOOD CONTROL DISTRICT 825 EAST THIRD STREET i ;. SAN BERNARDINO, CALIFORNIA 92408.; TELEPHONE (714) 383-1665 1 .PACIFIC TELEPHONE E TELEGRAPH COMPANY. 3073 ADAMS STREETs'�r,: RIVERSIDE, CALIFORNIA 92504 Ox _uky TELEPHONE (714) 359-2585 OR (800) 422-4133 3.. MCCUTCHAN CO., INC. 265 N. SAN GABRIEL BLVD. (818) 795-5162 PASADENA, CALIFORNIA 91107 Approved GERALD E. TUTT R. C. E. 14375 Dote CITY OF FONTANA , CALIFORNIA PUBLIC WORKS DEPARTMENT Drown by : p B SOUTHRIDGE VILLAGE stole: TRACT 2688 &-� III= ioo' Designed by : A � ' n� `� O I I Date W R K SEWER IMPROVEMENT PLANS6jo��86 Checked by :— Dwg.� No. J •T. J. . C, Approved CITY ENGINEER R.C.E.18932 /3,32 3 + p TYPICAL BEDDING FOR 8" VCP LESS THAN 10' DEEP NO SCALE 13OIZ T " IWI536R ZrN6/NC,fRIA16 CON&& TSI N75 I INC. Co /27 /8,9 TR No• /2Ga& L� 0 2/6J.0 7 sEAvFR L,1 0 0 riDnl ,`0 1Z Z oTS _ .35.9VD JG REV. DATEI DESCRIPTION APP, GENERAL NOTE S 1. THE CONSTRUCTION OF ALL PUBLIC IMPROVEMENTS SHALL CONFORM TO THESE PLANS AND TO THE REQUIREMENTS OF THE CITY STANDARD SPECIFICATIONS, PUBLIC WORKS DEPARTMENT, CITY OF FONTANA. REFER TO DEFINITIONS AND TERMS IN CITY STANDARD SPECIFICATIONS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM FONTANA PUBLIC. WORKS DEPARTMENT PRIOR TO START OF ANY WORK WITHIN THE CITY LIMITS. 3. STATIONING REFERS TO THE CENTERLINES OF STREET EXCEPT WHERE OTHERWISE NOTED. 4. ALL UNDERGROUND WORK SHALL BE COMPLETED PRIOR TO PAVING OF STREETS. 5. EXISTING UNDERGROUND UTILITIES ARE, AS PER AVAILABLE RECORDS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATION AND ELEVATION IN THE FIELD. 6. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING SYSTEM, SLOPING OF,THE GROUND OR OTHER EQUIVALENT MEANS. TRENCHES LESS THAN FIVE (5) FEET IN DEPTH SHALL ALSO BE GUARDED WHEN EXAMINATION INDICATES HAZARDOUS GROUND MOVEMENT MAY BE EXPECTED. 7. THE CONTRACTOR(S) SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK AS DESCRIBED IN NOTE 6 ABOVE FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. SEE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SECTION 306-1.1.6. 8. ALL MANHOLE FRAMES AND COVERS SHALL BE CONSTRUCTED 6" BELOW FINISHED GRADE BY SEWER CONTRACTOR AND SHALL BE RAISED TO GRADE BY PAVING CONTRACTOR AFTER COMPLETION OF PAVING. 9. REFER TO CITY OF FONTANA, UNDERGROUND UTILITY LOCATION STANDARD DETAIL 129. 10. ADEQUATE STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORKS TO THE PLAN GRADES. 11. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE CITY OF FONTANA. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RESETTING OF ANY SURVEY MONUMENTS, STREET CENTERLINE MONUMENTS, OR BENCH MARKS WHICH ARE DISTURBED DURING CONSTRUCTION WHETHER THEY ARE SHOWN ON THE PLANS OR NOT. 13. ALL 411 HOUSE SEWER LATERALS SHALL BE INSTALLED ON A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. INSTALL .SEWER CLEANOUT BOX FOR ALL HOUSE LATERALS PER STD. 125-A. 14. TERMINATE ALL 4" HOUSE SEWER LATERALS WITH A PLUG AT THE PROPERTY LINE UNLESS OTHERWISE NOTED. 15. CHIS. X SHALL BE PLACED ON THE CURB OVER LOCATIONS OF SEWER LATERALS BY THE SEWER CONTRACTOR. 16. IT SHALL' BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE HORIZONTAL LOCATION AND VERTICAL ELEVATIONS OF ALL UTILITY CROSSINGS FOR ALL UTILITIES CONSTRUCTED PRIOR TO THE SEWER. ANY DISCREPANCIES SHALL BE MADE IN WRITING TO THE OWNER PRIOR TO CONSTRUCTION. 17. CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITIES AND OTHER IMPROVEMENTS INCLUDING, BUT NOT LIMITED T0, GAS, TELEPHONE, ELECTRICAL, LIGHTING, TELEVISION CABLE, LANDSCAPING, LANDSCAPING IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAINAGE, FLOOD CONTROL SYSTEMS, ETC. 48 -HOURS PRIOR TO EXCAVATION NEAR THEIR FACILITIES, NOTIFY: CITY OF FONTANA 8353 SIERRA AVENUE FONTANA, CALIFORNIA 92335 TELEPHONE (714) 350-7610 SO. CALIF. GAS COMPANY - DISTRIBUTION FACILITIES 570 TH STREET, P.O. BOX 6226 SAN BERNARDINO, CALIFORNIA 92408 TELEPHONE (714) 884-9411 OR (800) 422-4133 SO. CALIF. GAS COMPANY - TRANSMISSION DEPARTMENT 2191 BIRCH STREET BREA, CALIFORNIA 92621 TELEPHONE (714) 529-2889 OR (800) 422-4133 SOUTHERN CALIFORNIA EDISON COMPANY 1351 E. FRANCIS AVENUE, P.O. BOX 513 ONTARIO, CALIFORNIA 91761 TELEPHONE (714) 947-2996 - UNDERGROUND POWER (714) 875-5100 - TRANSMISSION ( 213) 637-1233 — PIPELINES, OR (800) 422-4133 GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE POMONA, CALIFORNNA 91766 » TELEPHONE (213) 357-2257 OR (800) 422-4133 s` SAN BERN. COUNTY FLOOD CONTROL DISTRICT 825 EAST THIRD STREET i ;. SAN BERNARDINO, CALIFORNIA 92408.; TELEPHONE (714) 383-1665 1 .PACIFIC TELEPHONE E TELEGRAPH COMPANY. 3073 ADAMS STREETs'�r,: RIVERSIDE, CALIFORNIA 92504 Ox _uky TELEPHONE (714) 359-2585 OR (800) 422-4133 3.. MCCUTCHAN CO., INC. 265 N. SAN GABRIEL BLVD. (818) 795-5162 PASADENA, CALIFORNIA 91107 Approved GERALD E. TUTT R. C. E. 14375 Dote CITY OF FONTANA , CALIFORNIA PUBLIC WORKS DEPARTMENT Drown by : p B SOUTHRIDGE VILLAGE stole: TRACT 2688 &-� III= ioo' Designed by : A � ' n� `� O I I Date W R K SEWER IMPROVEMENT PLANS6jo��86 Checked by :— Dwg.� No. J •T. J. . C, Approved CITY ENGINEER R.C.E.18932 /3,32 3